MINING & TUNNELING CABLES TEBAOFLEX

Type G-CGC 2000V Round Portable Mining Cable

Heavy-duty 2000 V three-conductor Type G-CGC round portable mining power cable designed and manufactured to ICEA S-75-381 and CAN/CSA C22.2 No. 96 from 1 AWG through 500 kcmil. Features three 90 °C EPR-insulated phase conductors, three symmetrical rope-lay tinned-copper grounding conductors in the outer interstices and a centrally positioned 16 AWG extensible ground-check conductor inside a two-layer reinforced lead-cured CPE jacket.

Product information
Brand
TEBAOFLEX
Product overview

In conventional Round Type G-GC portable mining cables, two grounding conductors occupy two outer valleys while the insulated ground-check (pilot) wire occupies the third outer valley. Under high current and repeated reeling or bending around sheaves, that asymmetrical geometry induces unbalanced voltages onto the grounding system and subjects the outer ground-check wire to tensile elongation and premature fatigue breakage.

Type G-CGC 2000 V Round Portable Mining Cable solves both engineering problems simultaneously. First, the 16 AWG tinned-copper ground-check conductor is specially stranded for high extensibility, insulated with high-strength polypropylene and placed along the neutral axis in the center interstice between the three phase cores—shedding tensile load and dramatically extending pilot-circuit flex life.

Second, three equal-sized rope-lay-stranded tinned-copper grounding conductors (7 AWG to 2/0 AWG) are positioned symmetrically in the three outer interstices. In a balanced three-phase AC system, this 120-degree symmetrical grounding geometry cancels magnetic coupling so zero induced voltage is produced on the grounding system—making Type G-CGC compatible with both pilot-wire ground relays and wireless (impedance/audio-frequency) ground monitoring systems, as well as a direct drop-in replacement for standard Type G or Type G-GC cables.

Manufactured to ICEA S-75-381 and CAN/CSA C22.2 No. 96 from 1 AWG through 500 kcmil, Type G-CGC combines 90 °C EPR phase insulation (black, white, red) with a reinforced, two-layer, extra-heavy-duty lead-cured Chlorinated Polyethylene (CPE) jacket engineered to resist severe rock cutting, crushing, abrasion, oil and flame.

Explore the mining and tunneling cable range for related configurations.

Construction

Construction

The representative cutaway illustrates a 2000 V 3-conductor Type G-CGC round portable mining cable built to ICEA S-75-381 and CSA C22.2 No. 96, showing the three EPR phase conductors (black, white, red), the central yellow polypropylene-insulated 16 AWG extensible ground-check conductor, three symmetrical green grounding conductors in the outer interstices and the two-layer cord-reinforced lead-cured black CPE jacket.

Axial cross-section of a round Type G-CGC 2000V mining cable showing three large EPR phase cores in trefoil, one yellow extensible ground-check core in the center interstice and three symmetrical green ground cores in the outer valleys inside a two-layer reinforced black CPE jacket
Representative cable construction.
Type G-CGC 2000V Round Portable Mining Cable construction
ComponentMaterial and construction
Phase Conductors (3 × Power)1 AWG through 500 kcmil annealed tinned copper, bunched wires, rope-lay-stranded per ASTM B172 (259 strands on 1–1/0 AWG; 329 on 2/0 AWG; 413 on 3/0 AWG; 532 on 4/0 AWG; 608 on 250 kcmil; 851 on 350 kcmil; 1221 on 500 kcmil).
Phase Core Insulation90 °C Ethylene Propylene Rubber (EPR), color-coded black, white and red (0.080 in / 2.0 mm wall on 1 AWG–4/0 AWG; 0.095 in / 2.4 mm wall on 250–500 kcmil).
Center Extensible Ground-Check Conductor (CGC)16 AWG coated copper specially stranded to provide axial extensibility without sustaining tensile load, insulated with high-strength polypropylene and placed in the geometric center interstice for maximum flex-fatigue resistance.
Symmetrical Grounding Conductors (3 × Earth)Three equal rope-lay-stranded tinned-copper grounding conductors per ASTM B172 (3 × 7 AWG on 1 AWG up to 3 × 2/0 AWG on 500 kcmil) placed symmetrically in the three outer interstices to eliminate induced ground voltages.
Reinforced Two-Layer Outer JacketReinforced, two-layer, extra-heavy-duty lead-cured Chlorinated Polyethylene (CPE) in black (optional high-visibility colors, neoprene jacket or reflective stripe).
Applications

Applications

Specify Type G-CGC 2000 V cable for heavy AC mining trailing and feeder duty where pilot-wire breakage or induced ground voltages affect standard Type G-GC cables.

Heavy-duty black round Type G-CGC 2000V portable mining power cable terminated through a stainless-steel strain-relief gland into a mobile mine load-center switchgear skid
Application illustration.
  • Heavy AC mining trailing cables on continuous miners, loaders, shuttle cars and mobile feeder-breakers requiring fail-safe ground-check monitoring.
  • Mine power systems equipped with wireless ground monitoring relays that require a symmetrical 3-ground geometry with zero induced ground-loop voltage.
  • High-current 2000 V portable distribution drops (1 AWG to 500 kcmil, 161 A to 487 A) feeding underground load centers, ventilation fans, crushers and dewatering pumps.
  • Direct upgrade replacement for both standard Round Type G-GC (pilot-monitored) and Round Type G (unmonitored 3- or 4-ground) portable cables.
Specifications

Specifications

Type G-CGC 2000V Round Portable Mining Cable technical data
ParameterValue
Rated voltage and temperature2000 V phase-to-phase; 90 °C maximum continuous conductor operating temperature (−40 °C minimum cold bend).
Construction standardsDesigned and manufactured to ICEA S-75-381 / NEMA WC 58 and CAN/CSA C22.2 No. 96 Portable Power Cables; FT1 / FT5 and MSHA 30 CFR Part 18 flame-retardant jacket profile.
Conductor size range1 AWG (259 strands, 161 A) through 500 kcmil (1221 strands, 487 A) in 3-conductor round configuration.
Center extensible ground-check16 AWG specially stranded extensible coated copper with high-strength polypropylene insulation located on the neutral center axis to prevent pilot core snapping under flex and tension.
Symmetrical 3-ground systemThree equal rope-lay tinned-copper grounding conductors arranged at 120 degrees in the outer valleys, producing zero induced ground voltage in balanced 3-phase operation.
Minimum bending radius6 × overall cable diameter per ICEA S-75-381 and CSA C22.2 No. 96 for non-shielded round portable cables (9.9 in / 251 mm on 1 AWG to 18.2 in / 462 mm on 500 kcmil).
Type G-CGC vs Type G-GC & SHD-CGC boundaryChoose Type G-CGC (NA03) for unshielded 2000 V high-flex trailing service with center GC and 3 symmetrical grounds; choose standard Type G-GC (Product 1391) for 8–2 AWG smaller branch feeds; choose Type SHD-CGC (Product 3650) when individual metallic phase shields are required at 2 kV or 5 kV.
Type G-CGC 2000 V 3-Conductor Round Portable Mining Cable with Extensible Center Ground-Check — Dimensions, Weights and Ampacity (1 AWG – 500 kcmil)
DesignationPhase SizePhase StrandNom. Insulation Wall (in / mm)Symmetrical Grounds (3 ×)Center Ground-CheckNom. Cable O.D.Copper Weight (lbs/kft / kg/km)Net Weight (lbs/kft / kg/km)Ampacity 90 °C / 40 °C (A)
3/C 1 AWG Type G-CGC1 AWG2590.080 / 2.03 × 7 AWG16 AWG (Center)1.65 in / 41.9 mm1030 / 15332060 / 2798161
3/C 1/0 AWG Type G-CGC1/0 AWG2590.080 / 2.03 × 6 AWG16 AWG (Center)1.72 in / 43.7 mm1294 / 19262350 / 3408186
3/C 2/0 AWG Type G-CGC2/0 AWG3290.080 / 2.03 × 5 AWG16 AWG (Center)1.89 in / 48.0 mm1637 / 24362760 / 4018215
3/C 3/0 AWG Type G-CGC3/0 AWG4130.080 / 2.03 × 4 AWG16 AWG (Center)2.03 in / 51.6 mm2042 / 30383300 / 4837249
3/C 4/0 AWG Type G-CGC4/0 AWG5320.080 / 2.03 × 3 AWG16 AWG (Center)2.16 in / 54.9 mm2638 / 39263965 / 5901287
3/C 250 kcmil Type G-CGC250 kcmil6080.095 / 2.43 × 2 AWG16 AWG (Center)2.39 in / 60.7 mm3070 / 45695015 / 7463320
3/C 350 kcmil Type G-CGC350 kcmil8510.095 / 2.43 × 1 AWG16 AWG (Center)2.68 in / 68.1 mm4224 / 62866595 / 9814394
3/C 500 kcmil Type G-CGC500 kcmil12210.095 / 2.43 × 2/0 AWG16 AWG (Center)3.03 in / 77.0 mm6188 / 92088795 / 13090487
Type G-CGC 2000 V — 60 Hz Voltage Drop, Minimum Bending Radius (6 × O.D.), Reel Derated Ampacity and Working Tension Limit
Phase Size60 Hz V-Drop @ 80% PF (V/A/1000 ft)60 Hz V-Drop @ 90% PF (V/A/1000 ft)60 Hz V-Drop @ 100% PF (V/A/1000 ft)Min. Bend Radius (6 × O.D.)1-Layer Reel Ampacity (× 0.85)2-Layer Reel Ampacity (× 0.65)Approx. Max. Working Tension (10% Copper Rating)
1 AWG0.290.310.309.9 in / 251 mm136.9 A104.7 A1990 lbs (3 × 0.0663 sq.in. × 10% × 30000 psi)
1/0 AWG0.240.250.2410.3 in / 262 mm158.1 A120.9 A2490 lbs (3 × 0.0829 sq.in. × 10% × 30000 psi)
2/0 AWG0.200.200.1911.3 in / 288 mm182.8 A139.8 A3140 lbs (3 × 0.1045 sq.in. × 10% × 30000 psi)
3/0 AWG0.160.170.1512.2 in / 310 mm211.7 A161.9 A3960 lbs (3 × 0.1318 sq.in. × 10% × 30000 psi)
4/0 AWG0.140.140.1213.0 in / 329 mm244.0 A186.6 A4990 lbs (3 × 0.1662 sq.in. × 10% × 30000 psi)
250 kcmil0.120.120.1014.3 in / 364 mm272.0 A208.0 A5890 lbs (3 × 0.1963 sq.in. × 10% × 30000 psi)
350 kcmil0.100.090.0716.1 in / 409 mm334.9 A256.1 A8250 lbs (3 × 0.2749 sq.in. × 10% × 30000 psi)
500 kcmil0.080.070.0518.2 in / 462 mm414.0 A316.6 A11780 lbs (3 × 0.3927 sq.in. × 10% × 30000 psi)

All dimensions and weights are nominal and subject to standard industry tolerances; ampacities are based on 90 °C conductor temperature and 40 °C ambient air per ICEA S-75-381 / NEMA WC 58.

Because the three grounding conductors are symmetrical and the extensible 16 AWG ground-check is centered, Type G-CGC can also be connected as a standard 3-conductor Type G cable when pilot monitoring is not used.

For 2000 V variable-frequency drive (PWM inverter) trailing applications requiring an overall aluminum tape + tinned-copper braid EMC shield over a symmetrical 3-ground + center GC core, see Mining VFD Cable 2000 V (Product 5916).

Standards

Standards

Type G-CGC 2000V Round Portable Mining Cable standards and test references
Standard or specificationApplication
ICEA S-75-381 / NEMA WC 58Portable and power feeder cables for use in mines and similar applications (2000 V round portable cable construction and ampacity).
CAN/CSA C22.2 No. 96Canadian standard for portable power cables including FT1 / FT5 flame test profiles.
ASTM B172 & MSHA 30 CFR Part 18Rope-lay-stranded coated copper conductors and MSHA flame-resistance requirements (confirm specific listing/marking requirements during RFQ).

CSA Group — CAN/CSA C22.2 No. 96 Portable Power Cables standard reference

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.