CSA TECK90 & HVTECK Vertical Mine Shaft Cable
Three-conductor self-supporting vertical mine shaft and borehole power cable designed to CSA C22.2 No. 131 / No. 174 (5 kV unshielded TECK90, 90 mils TRXLPE) and CSA C68.10 (15 kV shielded HVTECK, 175 mils 100% and 220 mils 133% TRXLPE). Features a longitudinally ribbed black PVC inner jacket that mechanically locks with Galvanized Steel Interlocked Armor (GSIA) to prevent core slippage in vertical drops up to 298 m.
Conventional interlocked-armor cables cannot support their own weight in deep vertical mine shafts, boreholes or steep decline raises because the insulated core assembly slips downward inside the smooth inner bedding when suspended from the top. This Three-Conductor Vertical Self-Supporting CSA TECK90 (5 kV) and CSA HVTECK (15 kV) Mine Shaft Cable solves core slippage without the excessive weight and rigidity of traditional double steel-wire armor (SWA).
At the heart of the self-supporting mechanism is a heavy-duty black PVC inner jacket extruded with raised longitudinal ribs. When the Galvanized Steel Interlocked Armor (GSIA) is helically formed over the inner bedding, the steel armor profile bites firmly into the raised ribs—creating a mechanically locked core-to-armor structure. When the cable weight is suspended from the compact Class B bare copper conductors (1/0 AWG to 500 kcmil at 5 kV; 2 AWG to 750 kcmil at 15 kV), the core cannot slip relative to the armor or outer sheath.
The 5 kV CSA TECK90 construction utilizes a 90 mil (2.29 mm) unshielded Tree-Retardant Cross-Linked Polyethylene (TRXLPE, Type RW90) insulation system and a high-visibility orange CSA FT4 / IEEE 1202 overall PVC jacket. The 15 kV CSA HVTECK constructions feature triple-extruded semi-conducting strand shield, 175 mil (100% insulation level) or 220 mil (133% insulation level) TRXLPE dielectric, semi-conducting insulation shield, helically applied gapped copper tape shield and a red CSA FT4 / HL overall PVC jacket rated down to −40 °C cold bend and impact.
Explore the mining and tunneling cable range for related configurations.
Construction
The representative cutaway illustrates the 3-conductor 15 kV CSA HVTECK vertical self-supporting mine shaft cable, highlighting the compact bare copper phase conductors, triple-extruded TRXLPE dielectric, gapped copper tape shields, uninsulated bare copper bonding conductor, longitudinally ribbed black PVC inner jacket, Galvanized Steel Interlocked Armor (GSIA) biting into the ribs and flame-retardant red PVC outer jacket.

| Component | Material and construction |
|---|---|
| Phase Conductors (3 × Compact Copper) | 1/0 AWG through 500 kcmil (5 kV TECK90) or 2 AWG through 750 kcmil (15 kV HVTECK) bare annealed copper, compact Class B stranding. |
| Strand Shield & TRXLPE Insulation | Extruded thermoset semi-conducting strand shield with 90 °C (105 °C optional on 15 kV) Tree-Retardant XLPE (TRXLPE): 90 mils / 2.29 mm unshielded on 5 kV; 175 mils / 4.45 mm (100% level) or 220 mils / 5.59 mm (133% level) on 15 kV. |
| Insulation Shield (15 kV HVTECK) | Triple-extruded thermosetting semi-conducting insulation screen, longitudinal black/red/blue phase marker tape and helically applied gapped copper tape shield (5 kV TECK90 is unshielded with printed number coding). |
| Bonding (Ground) Conductor | One uninsulated stranded bare copper bonding conductor (6 AWG to 2 AWG sized by phase cross-section). |
| Longitudinally Ribbed Inner Jacket | Lead-free, flame-retardant, moisture- and sunlight-resistant black PVC extruded with raised longitudinal locking ribs. |
| Self-Locking Interlocked Armor (GSIA) | Galvanized Steel Interlocked Armor (GSIA) applied under controlled tension so it bites into the longitudinal inner-jacket ribs to lock the core against vertical slippage. |
| Overall Outer Jacket | Lead-free, acid-, moisture-, sunlight- and flame-retardant PVC (CSA FT1 / FT4, IEEE 1202): orange on 5 kV TECK90 and red on 15 kV HVTECK. |
Applications
Specify CSA TECK90 (5 kV) and CSA HVTECK (15 kV) vertical self-supporting armored cable for vertical mine shafts, ventilation raises, inclined ramps, hazardous-location risers and high-rise industrial power drops.

- Vertical mine shaft power feeders, borehole drops and steep decline/ramp distribution where the cable weight is supported by the copper conductors without core slippage (self-supporting vertical drops up to 278 m at 5 kV and up to 298 m at 15 kV).
- Exposed and concealed wiring in dry, damp, wet or corrosive underground mine levels and surface processing plants per Canadian Electrical Code (CE Code Part 1, Rules 12-708 and 22-200).
- Ventilated, non-ventilated and ladder-type vertical and horizontal cable trays, direct earth burial and hazardous locations (HL rating when terminated with certified HL glands).
- Lightweight, flexible replacement for traditional double Steel Wire Armored (SWA) shaft cables—simplifying reel handling and using standard TECK90 cabinet terminations.
Specifications
| Parameter | Value |
|---|---|
| Standards compliance | CSA C22.2 No. 131 and No. 174 (5 kV TECK90) and CSA C68.10 MV68.10 (15 kV HVTECK); Hazardous Location (HL) rated; CE Code Part 1 compliant. |
| Voltage and insulation levels | 5 kV unshielded (90 mils / 2.29 mm TRXLPE); 15 kV shielded 100% level (175 mils / 4.45 mm TRXLPE) and 15 kV shielded 133% level (220 mils / 5.59 mm TRXLPE). |
| Self-supporting vertical lock | Raised longitudinal ribs on the black PVC inner bedding engage the Galvanized Steel Interlocked Armor (GSIA), preventing core-to-armor slip during vertical suspension. |
| Self-supporting length basis | 85 m to 298 m vertical self-supporting span calculated at a safety factor of 5 and 37,000 psi tensile strength for soft-drawn copper conductors. |
| Temperature and cold-impact ratings | 90 °C continuous wet or dry operation (105 °C TRXLPE option on 15 kV); passes −40 °C cold bend and cold impact testing. |
| Flame and environmental ratings | CSA FT1, CSA FT4, IEEE 1202 (70,000 BTU/hr), IEEE 383, UL 1581, ICEA T-30-520 and ICEA T-29-520 (210,000 BTU/hr); EPA 40 CFR Part 261 TCLP lead-free and RoHS compliant. |
| Shaft cable vs standard TECK90 & MP-GC | Choose Vertical TECK90/HVTECK (NA05) for self-supporting vertical shaft drops with locked GSIA armor; choose standard CSA TECK90 600V–5kV (Product 4902) for horizontal tray runs; choose Type MP-GC (NA08) for MSHA CPE-jacketed borehole/feeder service with ground-check monitoring. |
| No. of Cond. | Cond. Size | Ground Wire Size | Nom. Insulation Wall (in / mm) | Nom. Dia. Over Insulation (in / mm) | Nom. Dia. Over Armor (in / mm) | Nom. Overall Cable O.D. (in / mm) | Copper Weight (lbs/1000 ft / kg/km) | Net Weight w/ Steel Armor (lbs/1000 ft / kg/km) | Ampacity 30 °C Ambient (A)** | Max. Self-Supporting Length (m)*** |
|---|---|---|---|---|---|---|---|---|---|---|
| 3 | 1/0 AWG | 6 AWG | 0.090 / 2.29 | 0.56 / 14.2 | 1.77 / 45.0 | 1.87 / 47.5 | 1082 / 1610 | 2700 / 4020 | 170 | 200 |
| 3 | 2/0 AWG | 6 AWG | 0.090 / 2.29 | 0.60 / 15.3 | 1.97 / 50.0 | 2.09 / 53.1 | 1340 / 1994 | 3270 / 4865 | 195 | 221 |
| 3 | 3/0 AWG | 4 AWG | 0.090 / 2.29 | 0.65 / 16.4 | 1.97 / 50.0 | 2.07 / 52.6 | 1720 / 2560 | 3550 / 5280 | 225 | 240 |
| 3 | 4/0 AWG | 4 AWG | 0.090 / 2.29 | 0.70 / 17.8 | 2.08 / 52.9 | 2.18 / 55.4 | 2315 / 3445 | 4290 / 6380 | 260 | 249 |
| 3 | 250 kcmil | 4 AWG | 0.090 / 2.29 | 0.75 / 19.1 | 2.25 / 57.2 | 2.35 / 59.7 | 2469 / 3674 | 4990 / 7430 | 290 | 251 |
| 3 | 350 kcmil | 3 AWG | 0.090 / 2.29 | 0.85 / 21.8 | 2.46 / 62.5 | 2.59 / 65.8 | 3476 / 5173 | 6340 / 9430 | 350 | 278 |
| 3 | 500 kcmil | 2 AWG | 0.090 / 2.29 | 0.98 / 24.9 | 2.72 / 69.1 | 2.85 / 72.4 | 4837 / 7198 | 8130 / 12100 | 430 | 230 |
| No. of Cond. | Cond. Size | Ground Wire Size | Nom. Dia. Over Insulation (in / mm) | Nom. Dia. Over Ins. Shield (in / mm) | Nom. Dia. Over Armor (in / mm) | Nom. Overall Cable O.D. (in / mm) | Copper Weight (lbs/1000 ft / kg/km) | Net Weight w/ Steel Armor (lbs/1000 ft / kg/km) | Max. Self-Supporting Length (m)** |
|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 AWG | 6 AWG | 0.76 / 19.3 | 0.82 / 20.8 | 2.50 / 63.5 | 2.66 / 67.6 | 862 / 1283 | 4138 / 6157 | 85 |
| 3 | 1 AWG | 6 AWG | 0.79 / 20.1 | 0.85 / 21.6 | 2.57 / 65.3 | 2.73 / 69.3 | 1034 / 1539 | 4424 / 6583 | 100 |
| 3 | 1/0 AWG | 6 AWG | 0.83 / 21.1 | 0.89 / 22.6 | 2.65 / 67.3 | 2.81 / 71.4 | 1245 / 1853 | 4765 / 7090 | 118 |
| 3 | 2/0 AWG | 6 AWG | 0.87 / 22.1 | 0.93 / 23.6 | 2.74 / 69.6 | 2.90 / 73.7 | 1513 / 2251 | 5181 / 7709 | 137 |
| 3 | 3/0 AWG | 4 AWG | 0.91 / 23.0 | 0.97 / 24.5 | 2.81 / 71.3 | 2.94 / 74.7 | 1717 / 2554 | 4993 / 7430 | 155 |
| 3 | 4/0 AWG | 4 AWG | 0.96 / 24.3 | 1.02 / 25.8 | 2.92 / 74.1 | 3.05 / 77.5 | 2130 / 3169 | 5752 / 8558 | 176 |
| 3 | 250 kcmil | 4 AWG | 1.02 / 25.8 | 1.08 / 27.3 | 3.05 / 77.4 | 3.20 / 81.2 | 2494 / 3711 | 6410 / 9538 | 188 |
| 3 | 350 kcmil | 3 AWG | 1.12 / 28.4 | 1.18 / 30.0 | 3.36 / 85.3 | 3.54 / 89.9 | 3692 / 5494 | 8674 / 12907 | 215 |
| 3 | 500 kcmil | 3 AWG | 1.23 / 31.2 | 1.30 / 33.0 | 3.62 / 91.9 | 3.80 / 96.5 | 5218 / 7764 | 10646 / 15841 | 250 |
| 3 | 750 kcmil | 2 AWG | 1.42 / 36.0 | 1.49 / 37.9 | 3.89 / 98.8 | 4.05 / 102.9 | 7296 / 10857 | 13728 / 20427 | 277 |
| No. of Cond. | Cond. Size | Ground Wire Size | Nom. Dia. Over Insulation (in / mm) | Nom. Dia. Over Ins. Shield (in / mm) | Nom. Dia. Over Armor (in / mm) | Nom. Overall Cable O.D. (in / mm) | Copper Weight (lbs/1000 ft / kg/km) | Net Weight w/ Steel Armor (lbs/1000 ft / kg/km) | Max. Self-Supporting Length (m)** |
|---|---|---|---|---|---|---|---|---|---|
| 3 | 2 AWG | 6 AWG | 0.67 / 17.0 | 0.72 / 18.3 | 2.30 / 58.4 | 2.46 / 62.5 | 845 / 1257 | 3761 / 5596 | 94 |
| 3 | 1 AWG | 6 AWG | 0.70 / 17.8 | 0.76 / 19.3 | 2.37 / 60.2 | 2.53 / 64.3 | 1017 / 1513 | 4022 / 5985 | 110 |
| 3 | 1/0 AWG | 6 AWG | 0.74 / 18.8 | 0.80 / 20.3 | 2.46 / 62.5 | 2.61 / 66.3 | 1229 / 1829 | 4385 / 6525 | 128 |
| 3 | 2/0 AWG | 6 AWG | 0.78 / 19.8 | 0.84 / 21.3 | 2.55 / 64.8 | 2.71 / 68.8 | 1497 / 2228 | 4800 / 7142 | 147 |
| 3 | 3/0 AWG | 4 AWG | 0.83 / 21.1 | 0.89 / 22.6 | 2.67 / 67.8 | 2.83 / 71.9 | 1882 / 2800 | 5354 / 7967 | 166 |
| 3 | 4/0 AWG | 4 AWG | 0.88 / 22.4 | 0.94 / 23.9 | 2.79 / 70.9 | 2.95 / 74.9 | 2304 / 3428 | 5979 / 8897 | 188 |
| 3 | 250 kcmil | 4 AWG | 0.92 / 23.4 | 0.98 / 24.9 | 2.89 / 73.4 | 3.05 / 77.5 | 2677 / 3983 | 6518 / 9699 | 204 |
| 3 | 350 kcmil | 3 AWG | 1.02 / 25.9 | 1.09 / 27.7 | 3.15 / 80.0 | 3.33 / 84.6 | 3675 / 5468 | 8043 / 11968 | 231 |
| 3 | 500 kcmil | 3 AWG | 1.14 / 29.0 | 1.21 / 30.7 | 3.47 / 88.1 | 3.66 / 93.0 | 5111 / 7605 | 10132 / 15076 | 262 |
| 3 | 750 kcmil | 2 AWG | 1.32 / 33.5 | 1.39 / 35.3 | 3.86 / 98.0 | 4.04 / 102.6 | 7555 / 11242 | 13403 / 19944 | 298 |
All dimensions and weights are nominal and subject to standard manufacturing tolerances; lower voltages (600 V / 1000 V) and 105 °C TRXLPE insulation are available upon request.
**5 kV TECK90 ampacity is based on Canadian Electrical Code (CE Code Part 1), Table 2 (three conductors in raceway/conduit) and Rule 4-004 at 30 °C ambient.
***Maximum vertical self-supporting lengths (m) are based on a safety factor of 5 and a tensile strength of 37,000 psi for soft-drawn copper conductors when cable weight is supported by the copper conductors.
Standards
| Standard or specification | Application |
|---|---|
| CSA C22.2 No. 131 & No. 174 | TECK90 armored power cables and hazardous location (HL) cable construction (5 kV unshielded vertical shaft series). |
| CSA C68.10 (MV68.10) | Shielded medium-voltage power cable specification for 15 kV (100% 175 mil and 133% 220 mil) HVTECK vertical shaft cables. |
| CSA FT1 / FT4, IEEE 1202 & ICEA T-29-520 | Vertical tray flame test compliances (70,000 BTU/hr and 210,000 BTU/hr) plus −40 °C cold bend and impact qualification. |
CSA Group — C22.2 No. 131 TECK90 & C68.10 HVTECK armored cable standards
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type MP-GC 15kV Mine Power Feeder Cable
A related cable option for a different application or duty profile.
View productFixed Mining Power Cable — PVC / HEPR, SWA / STA Options
A related cable option for a different application or duty profile.
View productType MV-105 EPR Copper-Tape-Screened Distribution Cable, 15 kV and 35 kV
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.