Three-conductor self-supporting vertical mine shaft and borehole power cable designed to CSA C22.2 No. 131 / No. 174 (5 kV unshielded TECK90, 90 mils TRXLPE) and CSA C68.10 (15 kV shielded HVTECK, 175 mils 100% and 220 mils 133% TRXLPE). Features a longitudinally ribbed black PVC inner jacket that mechanically locks with Galvanized Steel Interlocked Armor (GSIA) to prevent core slippage in vertical drops up to 298 m.

Product information
Brand
TEBAOFLEX
Product overview

Conventional interlocked-armor cables cannot support their own weight in deep vertical mine shafts, boreholes or steep decline raises because the insulated core assembly slips downward inside the smooth inner bedding when suspended from the top. This Three-Conductor Vertical Self-Supporting CSA TECK90 (5 kV) and CSA HVTECK (15 kV) Mine Shaft Cable solves core slippage without the excessive weight and rigidity of traditional double steel-wire armor (SWA).

At the heart of the self-supporting mechanism is a heavy-duty black PVC inner jacket extruded with raised longitudinal ribs. When the Galvanized Steel Interlocked Armor (GSIA) is helically formed over the inner bedding, the steel armor profile bites firmly into the raised ribs—creating a mechanically locked core-to-armor structure. When the cable weight is suspended from the compact Class B bare copper conductors (1/0 AWG to 500 kcmil at 5 kV; 2 AWG to 750 kcmil at 15 kV), the core cannot slip relative to the armor or outer sheath.

The 5 kV CSA TECK90 construction utilizes a 90 mil (2.29 mm) unshielded Tree-Retardant Cross-Linked Polyethylene (TRXLPE, Type RW90) insulation system and a high-visibility orange CSA FT4 / IEEE 1202 overall PVC jacket. The 15 kV CSA HVTECK constructions feature triple-extruded semi-conducting strand shield, 175 mil (100% insulation level) or 220 mil (133% insulation level) TRXLPE dielectric, semi-conducting insulation shield, helically applied gapped copper tape shield and a red CSA FT4 / HL overall PVC jacket rated down to −40 °C cold bend and impact.

Explore the mining and tunneling cable range for related configurations.

Construction

Construction

The representative cutaway illustrates the 3-conductor 15 kV CSA HVTECK vertical self-supporting mine shaft cable, highlighting the compact bare copper phase conductors, triple-extruded TRXLPE dielectric, gapped copper tape shields, uninsulated bare copper bonding conductor, longitudinally ribbed black PVC inner jacket, Galvanized Steel Interlocked Armor (GSIA) biting into the ribs and flame-retardant red PVC outer jacket.

Axial cross-section of a 3-conductor CSA HVTECK 15kV vertical mine shaft cable showing three copper-tape-shielded TRXLPE phase cores, one bare copper ground conductor, black PVC inner bedding with raised longitudinal locking ribs, Galvanized Steel Interlocked Armor and red PVC outer sheath
Representative cable construction.
CSA TECK90 & HVTECK Vertical Mine Shaft Cable construction
ComponentMaterial and construction
Phase Conductors (3 × Compact Copper)1/0 AWG through 500 kcmil (5 kV TECK90) or 2 AWG through 750 kcmil (15 kV HVTECK) bare annealed copper, compact Class B stranding.
Strand Shield & TRXLPE InsulationExtruded thermoset semi-conducting strand shield with 90 °C (105 °C optional on 15 kV) Tree-Retardant XLPE (TRXLPE): 90 mils / 2.29 mm unshielded on 5 kV; 175 mils / 4.45 mm (100% level) or 220 mils / 5.59 mm (133% level) on 15 kV.
Insulation Shield (15 kV HVTECK)Triple-extruded thermosetting semi-conducting insulation screen, longitudinal black/red/blue phase marker tape and helically applied gapped copper tape shield (5 kV TECK90 is unshielded with printed number coding).
Bonding (Ground) ConductorOne uninsulated stranded bare copper bonding conductor (6 AWG to 2 AWG sized by phase cross-section).
Longitudinally Ribbed Inner JacketLead-free, flame-retardant, moisture- and sunlight-resistant black PVC extruded with raised longitudinal locking ribs.
Self-Locking Interlocked Armor (GSIA)Galvanized Steel Interlocked Armor (GSIA) applied under controlled tension so it bites into the longitudinal inner-jacket ribs to lock the core against vertical slippage.
Overall Outer JacketLead-free, acid-, moisture-, sunlight- and flame-retardant PVC (CSA FT1 / FT4, IEEE 1202): orange on 5 kV TECK90 and red on 15 kV HVTECK.
Applications

Applications

Specify CSA TECK90 (5 kV) and CSA HVTECK (15 kV) vertical self-supporting armored cable for vertical mine shafts, ventilation raises, inclined ramps, hazardous-location risers and high-rise industrial power drops.

Red-jacketed CSA HVTECK 15kV and orange-jacketed CSA TECK90 5kV vertical self-supporting armored cables suspended down a concrete-lined underground mine shaft collar with heavy-duty top suspension clamps
Application illustration.
  • Vertical mine shaft power feeders, borehole drops and steep decline/ramp distribution where the cable weight is supported by the copper conductors without core slippage (self-supporting vertical drops up to 278 m at 5 kV and up to 298 m at 15 kV).
  • Exposed and concealed wiring in dry, damp, wet or corrosive underground mine levels and surface processing plants per Canadian Electrical Code (CE Code Part 1, Rules 12-708 and 22-200).
  • Ventilated, non-ventilated and ladder-type vertical and horizontal cable trays, direct earth burial and hazardous locations (HL rating when terminated with certified HL glands).
  • Lightweight, flexible replacement for traditional double Steel Wire Armored (SWA) shaft cables—simplifying reel handling and using standard TECK90 cabinet terminations.
Specifications

Specifications

CSA TECK90 & HVTECK Vertical Mine Shaft Cable technical data
ParameterValue
Standards complianceCSA C22.2 No. 131 and No. 174 (5 kV TECK90) and CSA C68.10 MV68.10 (15 kV HVTECK); Hazardous Location (HL) rated; CE Code Part 1 compliant.
Voltage and insulation levels5 kV unshielded (90 mils / 2.29 mm TRXLPE); 15 kV shielded 100% level (175 mils / 4.45 mm TRXLPE) and 15 kV shielded 133% level (220 mils / 5.59 mm TRXLPE).
Self-supporting vertical lockRaised longitudinal ribs on the black PVC inner bedding engage the Galvanized Steel Interlocked Armor (GSIA), preventing core-to-armor slip during vertical suspension.
Self-supporting length basis85 m to 298 m vertical self-supporting span calculated at a safety factor of 5 and 37,000 psi tensile strength for soft-drawn copper conductors.
Temperature and cold-impact ratings90 °C continuous wet or dry operation (105 °C TRXLPE option on 15 kV); passes −40 °C cold bend and cold impact testing.
Flame and environmental ratingsCSA FT1, CSA FT4, IEEE 1202 (70,000 BTU/hr), IEEE 383, UL 1581, ICEA T-30-520 and ICEA T-29-520 (210,000 BTU/hr); EPA 40 CFR Part 261 TCLP lead-free and RoHS compliant.
Shaft cable vs standard TECK90 & MP-GCChoose Vertical TECK90/HVTECK (NA05) for self-supporting vertical shaft drops with locked GSIA armor; choose standard CSA TECK90 600V–5kV (Product 4902) for horizontal tray runs; choose Type MP-GC (NA08) for MSHA CPE-jacketed borehole/feeder service with ground-check monitoring.
5 kV CSA TECK90 3-Conductor Unshielded Vertical Self-Supporting Shaft Cable (90 mils / 2.29 mm TRXLPE, GSIA, Orange PVC) — 1/0 AWG to 500 kcmil
No. of Cond.Cond. SizeGround Wire SizeNom. Insulation Wall (in / mm)Nom. Dia. Over Insulation (in / mm)Nom. Dia. Over Armor (in / mm)Nom. Overall Cable O.D. (in / mm)Copper Weight (lbs/1000 ft / kg/km)Net Weight w/ Steel Armor (lbs/1000 ft / kg/km)Ampacity 30 °C Ambient (A)**Max. Self-Supporting Length (m)***
31/0 AWG6 AWG0.090 / 2.290.56 / 14.21.77 / 45.01.87 / 47.51082 / 16102700 / 4020170200
32/0 AWG6 AWG0.090 / 2.290.60 / 15.31.97 / 50.02.09 / 53.11340 / 19943270 / 4865195221
33/0 AWG4 AWG0.090 / 2.290.65 / 16.41.97 / 50.02.07 / 52.61720 / 25603550 / 5280225240
34/0 AWG4 AWG0.090 / 2.290.70 / 17.82.08 / 52.92.18 / 55.42315 / 34454290 / 6380260249
3250 kcmil4 AWG0.090 / 2.290.75 / 19.12.25 / 57.22.35 / 59.72469 / 36744990 / 7430290251
3350 kcmil3 AWG0.090 / 2.290.85 / 21.82.46 / 62.52.59 / 65.83476 / 51736340 / 9430350278
3500 kcmil2 AWG0.090 / 2.290.98 / 24.92.72 / 69.12.85 / 72.44837 / 71988130 / 12100430230
15 kV CSA HVTECK 3-Conductor Shielded Vertical Self-Supporting Shaft Cable (133% Ins. Level, 220 mils / 5.59 mm TRXLPE, Copper Tape Shield, GSIA, Red PVC) — 2 AWG to 750 kcmil
No. of Cond.Cond. SizeGround Wire SizeNom. Dia. Over Insulation (in / mm)Nom. Dia. Over Ins. Shield (in / mm)Nom. Dia. Over Armor (in / mm)Nom. Overall Cable O.D. (in / mm)Copper Weight (lbs/1000 ft / kg/km)Net Weight w/ Steel Armor (lbs/1000 ft / kg/km)Max. Self-Supporting Length (m)**
32 AWG6 AWG0.76 / 19.30.82 / 20.82.50 / 63.52.66 / 67.6862 / 12834138 / 615785
31 AWG6 AWG0.79 / 20.10.85 / 21.62.57 / 65.32.73 / 69.31034 / 15394424 / 6583100
31/0 AWG6 AWG0.83 / 21.10.89 / 22.62.65 / 67.32.81 / 71.41245 / 18534765 / 7090118
32/0 AWG6 AWG0.87 / 22.10.93 / 23.62.74 / 69.62.90 / 73.71513 / 22515181 / 7709137
33/0 AWG4 AWG0.91 / 23.00.97 / 24.52.81 / 71.32.94 / 74.71717 / 25544993 / 7430155
34/0 AWG4 AWG0.96 / 24.31.02 / 25.82.92 / 74.13.05 / 77.52130 / 31695752 / 8558176
3250 kcmil4 AWG1.02 / 25.81.08 / 27.33.05 / 77.43.20 / 81.22494 / 37116410 / 9538188
3350 kcmil3 AWG1.12 / 28.41.18 / 30.03.36 / 85.33.54 / 89.93692 / 54948674 / 12907215
3500 kcmil3 AWG1.23 / 31.21.30 / 33.03.62 / 91.93.80 / 96.55218 / 776410646 / 15841250
3750 kcmil2 AWG1.42 / 36.01.49 / 37.93.89 / 98.84.05 / 102.97296 / 1085713728 / 20427277
15 kV CSA HVTECK 3-Conductor Shielded Vertical Self-Supporting Shaft Cable (100% Ins. Level, 175 mils / 4.45 mm TRXLPE, Copper Tape Shield, GSIA, Red PVC) — 2 AWG to 750 kcmil
No. of Cond.Cond. SizeGround Wire SizeNom. Dia. Over Insulation (in / mm)Nom. Dia. Over Ins. Shield (in / mm)Nom. Dia. Over Armor (in / mm)Nom. Overall Cable O.D. (in / mm)Copper Weight (lbs/1000 ft / kg/km)Net Weight w/ Steel Armor (lbs/1000 ft / kg/km)Max. Self-Supporting Length (m)**
32 AWG6 AWG0.67 / 17.00.72 / 18.32.30 / 58.42.46 / 62.5845 / 12573761 / 559694
31 AWG6 AWG0.70 / 17.80.76 / 19.32.37 / 60.22.53 / 64.31017 / 15134022 / 5985110
31/0 AWG6 AWG0.74 / 18.80.80 / 20.32.46 / 62.52.61 / 66.31229 / 18294385 / 6525128
32/0 AWG6 AWG0.78 / 19.80.84 / 21.32.55 / 64.82.71 / 68.81497 / 22284800 / 7142147
33/0 AWG4 AWG0.83 / 21.10.89 / 22.62.67 / 67.82.83 / 71.91882 / 28005354 / 7967166
34/0 AWG4 AWG0.88 / 22.40.94 / 23.92.79 / 70.92.95 / 74.92304 / 34285979 / 8897188
3250 kcmil4 AWG0.92 / 23.40.98 / 24.92.89 / 73.43.05 / 77.52677 / 39836518 / 9699204
3350 kcmil3 AWG1.02 / 25.91.09 / 27.73.15 / 80.03.33 / 84.63675 / 54688043 / 11968231
3500 kcmil3 AWG1.14 / 29.01.21 / 30.73.47 / 88.13.66 / 93.05111 / 760510132 / 15076262
3750 kcmil2 AWG1.32 / 33.51.39 / 35.33.86 / 98.04.04 / 102.67555 / 1124213403 / 19944298

All dimensions and weights are nominal and subject to standard manufacturing tolerances; lower voltages (600 V / 1000 V) and 105 °C TRXLPE insulation are available upon request.

**5 kV TECK90 ampacity is based on Canadian Electrical Code (CE Code Part 1), Table 2 (three conductors in raceway/conduit) and Rule 4-004 at 30 °C ambient.

***Maximum vertical self-supporting lengths (m) are based on a safety factor of 5 and a tensile strength of 37,000 psi for soft-drawn copper conductors when cable weight is supported by the copper conductors.

Standards

Standards

CSA TECK90 & HVTECK Vertical Mine Shaft Cable standards and test references
Standard or specificationApplication
CSA C22.2 No. 131 & No. 174TECK90 armored power cables and hazardous location (HL) cable construction (5 kV unshielded vertical shaft series).
CSA C68.10 (MV68.10)Shielded medium-voltage power cable specification for 15 kV (100% 175 mil and 133% 220 mil) HVTECK vertical shaft cables.
CSA FT1 / FT4, IEEE 1202 & ICEA T-29-520Vertical tray flame test compliances (70,000 BTU/hr and 210,000 BTU/hr) plus −40 °C cold bend and impact qualification.

CSA Group — C22.2 No. 131 TECK90 & C68.10 HVTECK armored cable standards

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.