MINING & TUNNELING CABLES TEBAOFLEX

Fixed Mining Power Cable — PVC / HEPR, SWA / STA Options

Copper power cables for fixed mine distribution and equipment supply. Select the exact Polish, Czech or MGM 109 construction, with PVC or HEPR insulation and unarmoured, steel-wire or steel-tape options.

Product information
Brand
TEBAOFLEX
Product overview

Fixed mining power cable supplies installed mine distribution circuits, machines and electrical equipment. This family groups PVC- and HEPR-insulated copper constructions rated from 0.6/1 kV to 3.6/6 kV, with separate tables for Polish, Czech and MGM 109 model designations. Choose the exact model, voltage and armouring arrangement before selecting conductor size.

The Polish selections cover unarmoured YnKGY-żo and YKGYyn-żo, round steel-wire-armoured YKGYFoyn and steel-tape-armoured YKGYFtZnyn. Their installation scope includes specific mine-area conditions and, for the armoured constructions, different shaft or excavation inclination limits. The 0.6/1 kV and 3.6/6 kV versions of YKGYFoyn also differ in conductor arrangement, metallic screening and sheath colour.

The Czech selections include solid-conductor CYKYDY-J at 0.6/1 kV, HEPR-insulated CHKCYDY and PVC-insulated CYKCYDY at 3.6/6 kV. The two medium voltage designs have a concentric copper conductor and steel-wire armour, with separate thermal limits. MGM 109 Type 1012, 1013 and 1014 use single wire armour; Types 1023 and 1024 use two layers. At 1.9/3.3 kV, Type 3013 is single armoured, Type 3023 is double armoured and Type 3123 adds individual copper-backed tape screens.

Use the model-specific size, bend-radius and electrical tables to plan the cable route and terminations. Provide the supply voltage, complete conductor configuration, mine classification, armouring requirement, route length and required drum lengths with the enquiry. Check support spacing, pulling arrangements and cable-entry space together with the chosen cable diameter.

Explore the mining and tunneling cable range for related configurations.

For underground gallery distribution and vertical shaft drop routes requiring metallic armouring, compare these mining power cables: YnOGY / YnOGYek / YnOGYekm PVC Mining Cable 0.6/1 kV (for 0.6/1 kV Polish-standard PVC mining distribution cables with unarmoured, steel tape, or round steel wire armour options); Mine Borehole & Shaft Self-Supporting Armoured Drop Cable (0.6/1–15 kV) (for 0.6/1 kV to 15 kV self-supporting steel-wire-armoured borehole and vertical shaft feeders). Verify insulation thermal class (PVC vs HEPR), armour tensile rating, and gallery flame-retardant rules before ordering.

Construction

Construction

The representative image shows YKGYFoyn 3 × 35/16 mm² at 3.6/6 kV: three compacted copper phase conductors in a triangular arrangement, PVC insulation and bedding, a common copper-tape screen, a separating PVC layer, one layer of round steel-wire armour and a red PVC outer sheath.

Round YKGYFoyn cross-section with three compacted copper conductors in a triangle, PVC layers, common copper screen and steel-wire armour
Representative cable construction.
Fixed Mining Power Cable — PVC / HEPR, SWA / STA Options construction
ComponentMaterial and construction
Copper conductorsClass 1 or Class 2 according to the selected model. CHKCYDY, CYKCYDY and medium voltage MGM designs use Class 2; the listed CYKYDY-J designs use Class 1.
Insulation selectionPVC for the Polish, CYKYDY-J, CYKCYDY and MGM constructions; HEPR for CHKCYDY.
Unarmoured Polish constructionsYnKGY-żo has PVC insulation and outer sheath. YKGYyn-żo adds an inner PVC sheath. Both include a green-yellow protective core.
YKGYFoyn armour and screenOne layer of round galvanised steel wires. The 3.6/6 kV construction has a common copper-tape screen and PVC separating layer.
YKGYFtZnyn 3.6/6 kVCommon copper-tape screen, PVC separator and galvanised steel-tape armour.
Czech medium voltage concentric layerSemiconductive tape, round copper wires, copper tape and plastic tape outside the insulated core assembly, followed by the separation layer and single steel-wire armour.
MGM single and double wire armourTypes 1012/1013/1014 and 3013: single layer; Types 1023/1024, 3023 and 3123: two layers. PVC bedding and special PVC outer sheath; optional galvanised steel-tape separator.
MGM Type 3123 screeningSemiconducting separator layer and copper-backed tape screen around each insulated core, before the common bedding and two armour layers.
Outer-sheath identificationPolish 0.6/1 kV designs: yellow; Polish and Czech 3.6/6 kV designs: red; CYKYDY-J: black. State the required MGM sheath colour with the order.
Applications

Applications

Select these constructions for supported fixed power routes. The model tables preserve the differences in mine-area scope, insulation, armour and permissible installation conditions.

Red fixed armoured mining feeder cable clamped to a tunnel cable ladder and entering a closed distribution enclosure
Application illustration.
  • Fixed mine distribution and machinery supply routes with mechanically protected cable entries and suitable support.
  • YnKGY-żo and YKGYyn-żo: open-pit, strip and underground mine equipment in areas without an explosion hazard, including the specified class A coal-dust excavation scope.
  • YKGYFoyn: mine feeders and shafts or inclined excavations up to 90° within the selected voltage construction’s scope.
  • YKGYFtZnyn 3.6/6 kV: fixed mine power transmission in excavations with inclination up to 45°.
  • CYKYDY-J: fixed power networks requiring additional mechanical protection, including underground, outdoor, indoor and duct routes.
  • CHKCYDY and CYKCYDY: fixed medium voltage distribution in industrial areas, buildings and associated mine infrastructure.
  • MGM 109: fixed supply to machines and equipment on the surface and in deep mines; specify the site’s gas, dust and acceptance requirements.
  • Use a separately selected flexible mining cable for trailing, continuous reeling or repetitive machine movement.

For fixed underground mine power routing guidelines and British-standard roadway distribution cables, consult these references: Armoured and Static Mining Cable: Fixed Distribution Routes (covering SWA vs STA mechanical protection, earthing conductance, and roadway suspension spacing); Type 20 / Type 21 BS 6708 640/1100 V Armoured Mining Cable (for 640/1100 V BS 6708 Type 20 single-wire-armoured and Type 21 double-wire-armoured roadway and face distribution cables). Confirm fault-current armour conductance, coupler compatibility, and water-blocking needs.

Specifications

Specifications

Fixed Mining Power Cable — PVC / HEPR, SWA / STA Options technical data
ParameterValue
DutyFixed installation; model-specific armouring and mine-area selection.
Voltage familiesPolish/Czech low voltage: 0.6/1 kV; MGM low voltage: 600/1000 V; MGM medium voltage: 1900/3300 V; Polish/Czech medium voltage: 3.6/6 kV.
Insulation and temperaturePVC models generally have a 70°C conductor limit where specified. CHKCYDY HEPR has a 90°C conductor limit. Use the thermal table for each construction.
Armouring choicesUnarmoured, single round steel wire, double round steel wire or steel tape, according to the exact designation.
Screen selectionUnscreened, common copper-tape screen, concentric copper conductor or individual copper-backed tape screens, according to model.
Bend allowanceUse the model-specific multiple of D or the stated minimum bend radius in each MGM row.
Ordering identificationGive the model, U₀/U, full core configuration, insulation, armour and applicable mine-area requirements.
Fixed mining cable model, voltage and armour selection
ModelRated voltage U₀/UInsulationScreen / concentric layerArmourTest voltage
YnKGY-żo0.6/1 kVPVCNoneNone3.5 kV
YKGYyn-żo0.6/1 kVPVCNoneNone3.5 kV
YKGYFoyn0.6/1 kVPVCProtective components to configurationSingle round steel wire3.5 kV
YKGYFoyn3.6/6 kVPVCCommon copper tapeSingle round steel wire11 kV
YKGYFtZnyn3.6/6 kVPVCCommon copper tapeGalvanised steel tape11 kV
CYKYDY-J0.6/1 kVPVC DIV1NoneSingle round steel wireBy ordered specification
CHKCYDY3.6/6 kVHEPRConcentric copper conductorSingle round steel wireBy ordered specification
CYKCYDY3.6/6 kVPVC DIV6Concentric copper conductorSingle round steel wire11 kV AC, 5 min, 50 Hz
MGM 109 Type 1012 / 1013 / 1014600/1000 VPVCNoneSingle steel wire3 kV
MGM 109 Type 1023 / 1024600/1000 VPVCNoneDouble steel wire3 kV
MGM 109 Type 30131900/3300 VPVCNoneSingle steel wire10 kV
MGM 109 Type 30231900/3300 VPVCNoneDouble steel wire10 kV
MGM 109 Type 31231900/3300 VPVCIndividual copper-backed tapesDouble steel wire6 kV
Fixed mining cable thermal, installation and bend limits
ConstructionMaximum conductor temperatureMinimum fixed ambientMinimum laying temperatureShort-circuit temperatureMinimum bend radius
YnKGY-żo / YKGYyn-żo70°C−30°C−5°CBy ordered specification10 × D
YKGYFoyn 0.6/1 kV70°C−30°C−5°CBy ordered specification10 × D
YKGYFoyn / YKGYFtZnyn 3.6/6 kV70°C−30°CBy installation specificationBy ordered specification10 × D
CYKYDY-J70°C−20°C−5°C160°C15 × D
CHKCYDY90°C−30°C0°C250°C12 × D for circular conductors
CYKCYDY70°C−30°C0°C150°C12 × D for circular conductors
MGM 109 constructionsBy ordered specificationBy installation specificationBy installation specificationBy ordered specificationConfiguration-specific mm values below
YnKGY-żo 0.6/1 kV dimensions
Model and conductor configurationMax. overall diameter (mm)Calculated weight (kg/km)
YnKGY-żo 3 × 1.5 mm²10.2153
YnKGY-żo 4 × 1.5 mm²11.1180
YnKGY-żo 5 × 1.5 mm²11.8215
YnKGY-żo 3 × 2.5 mm²11.0195
YnKGY-żo 4 × 2.5 mm²12.0235
YnKGY-żo 5 × 2.5 mm²12.9280
YnKGY-żo 3 × 4 mm²12.9280
YnKGY-żo 4 × 4 mm²14.2345
YnKGY-żo 5 × 4 mm²15.2410
YnKGY-żo 3 × 6 mm²13.9355
YnKGY-żo 4 × 6 mm²15.4440
YnKGY-żo 5 × 6 mm²16.6525
YnKGY-żo 3 × 10 mm²16.4520
YnKGY-żo 4 × 10 mm²18.1655
YnKGY-żo 5 × 10 mm²19.6790
YKGYyn-żo 0.6/1 kV dimensions
Model and conductor configurationMax. overall diameter (mm)Calculated weight (kg/km)
YKGYyn-żo 3 × 1.5 mm²13.9260
YKGYyn-żo 4 × 1.5 mm²14.8300
YKGYyn-żo 5 × 1.5 mm²15.6350
YKGYyn-żo 3 × 2.5 mm²14.7310
YKGYyn-żo 4 × 2.5 mm²15.8355
YKGYyn-żo 5 × 2.5 mm²16.6425
YKGYyn-żo 3 × 4 mm²16.6410
YKGYyn-żo 4 × 4 mm²17.9480
YKGYyn-żo 5 × 4 mm²19.0580
YKGYyn-żo 3 × 6 mm²17.7490
YKGYyn-żo 4 × 6 mm²19.1590
YKGYyn-żo 5 × 6 mm²20.3720
YKGYyn-żo 3 × 10 mm²20.1560
YKGYyn-żo 4 × 10 mm²21.9660
YKGYyn-żo 5 × 10 mm²23.3820
YKGYFoyn 0.6/1 kV dimensions
Model and conductor configurationMax. overall diameter (mm)Calculated weight (kg/km)
YKGYFoyn 3 × 10/6 mm²25.91600
YKGYFoyn 3 × 16/16 mm²28.42040
YKGYFoyn 3 × 25/16 mm²32.62600
YKGYFoyn 3 × 35/16 mm²34.32990
YKGYFoyn 3 × 50/16 mm²37.93680
YKGYFoyn 3 × 70/25 mm²43.24780
YKGYFoyn 3 × 95/25 mm²48.65950
YKGYFoyn 3 × 120/35 mm²52.97140
YKGYFoyn 3.6/6 kV dimensions
Model and conductor configurationCalculated overall diameter (mm)Calculated weight (kg/km)
YKGYFoyn 3 × 10/10 mm²46.84715
YKGYFoyn 3 × 16/10 mm²49.65290
YKGYFoyn 3 × 25/14 mm²52.55963
YKGYFoyn 3 × 35/16 mm²53.96460
YKGYFoyn 3 × 50/18 mm²59.28315
YKGYFoyn 3 × 70/18 mm²64.59753
YKGYFoyn 3 × 95/20 mm²68.811178
YKGYFoyn 3 × 120/22 mm²71.312670
YKGYFoyn 3 × 150/24 mm²75.514455
YKGYFoyn 3 × 185/27 mm²84.518462
YKGYFtZnyn 3.6/6 kV dimensions
Model and conductor configurationCalculated overall diameter (mm)Calculated weight (kg/km)
YKGYFtZnyn 3 × 10/10 mm²38.72298
YKGYFtZnyn 3 × 16/10 mm²41.52711
YKGYFtZnyn 3 × 25/14 mm²44.53377
YKGYFtZnyn 3 × 35/16 mm²47.24241
YKGYFtZnyn 3 × 50/18 mm²51.05022
YKGYFtZnyn 3 × 70/18 mm²55.05989
YKGYFtZnyn 3 × 95/20 mm²60.07240
YKGYFtZnyn 3 × 120/22 mm²63.88272
YKGYFtZnyn 3 × 150/24 mm²69.39948
YKGYFtZnyn 3 × 185/27 mm²72.711978
YnKGY-żo and YKGYyn-żo 0.6/1 kV electrical data
Power conductor (mm²)Resistance (Ω/km)Inductance (mH/km)Reactance (Ω/km)Reference current (A)1 s short-circuit capacity (kA)
1.512.10.340.107190.17
2.57.410.320.099270.29
44.610.320.100370.46
63.080.300.095470.69
101.830.280.089621.15
YKGYFoyn 0.6/1 kV electrical data
Power conductor (mm²)Resistance (Ω/km)Inductance (mH/km)Reactance (Ω/km)Reference current (A)1 s short-circuit capacity (kA)
101.830.310.098641.15
161.150.300.092861.84
250.7270.300.0921132.88
350.5240.290.0901394.03
500.3870.280.0881735.75
700.2680.260.0852128.05
950.1930.260.08425710.93
1200.1530.260.08329413.80
YKGYFoyn 3.6/6 kV electrical data
Power conductor (mm²)Resistance (Ω/km)Inductance (mH/km)Reactance (Ω/km)Capacitance to earth (µF/km)To-earth current reference (A/km)1 s short-circuit capacity (kA)Reference continuous current (A)
101.830.4000.1260.110.351.1568
161.150.3720.1170.110.371.8487
250.7270.3490.1100.120.402.88113
350.5240.3380.1060.130.414.03137
500.3870.3170.1000.130.435.75164
700.2680.2990.0940.140.458.05202
950.1930.2860.0900.150.4710.93245
1200.1530.2780.0870.150.4913.8281
1500.1240.2680.0840.150.5017.25319
1850.09910.2620.0820.160.5121.28369
YKGYFtZnyn 3.6/6 kV electrical data
Power conductor (mm²)Resistance (Ω/km)Inductance (mH/km)Reactance (Ω/km)Capacitance to earth (µF/km)To-earth current reference (A/km)1 s short-circuit capacity (kA)Reference continuous current (A)
101.830.4000.1260.110.351.1566
161.150.3720.1170.110.371.8485
250.7270.3490.1100.120.402.88110
350.5240.3380.1060.130.414.03133
500.3870.3170.1000.130.435.75160
700.2680.2990.0940.140.458.05197
950.1930.2860.0900.150.4710.93240
1200.1530.2780.0870.150.4913.8276
1500.1240.2680.0840.150.5017.25314
1850.09910.2620.0820.160.5121.28360
CYKYDY-J dimensions and conductor resistance
Model and conductor configurationApprox. overall diameter (mm)Approx. weight (kg/km)Max. conductor resistance at 20°C (Ω/km)
CYKYDY-J 4 × 2.5RE mm²15.85347.41
CYKYDY-J 5 × 2.5RE mm²16.76107.41
CYKYDY-J 12 × 1.5RE mm²20.082312.1
CYKYDY-J 12 × 2.5RE mm²21.610037.41
CYKYDY-J 37 × 2.5RE mm²32.023277.41
CHKCYDY dimensions and conductor resistance
Model and conductor configurationApprox. overall diameter (mm)Approx. weight (kg/km)Max. conductor resistance at 20°C (Ω/km)
CHKCYDY 3 × 70/50 mm²51.859930.268/0.387
CHKCYDY 3 × 95/50 mm²55.470950.193/0.387
CHKCYDY 3 × 120/50 mm²58.981750.153/0.387
CHKCYDY 3 × 150/50 mm²6292330.124/0.387
CYKCYDY dimensions and conductor resistance
Model and conductor configurationApprox. overall diameter (mm)Approx. weight (kg/km)Max. conductor resistance at 20°C (Ω/km)
CYKCYDY 3 × 50SM/25 mm²48.952860.387/0.727
CYKCYDY 3 × 95SM/50 mm²56.875530.193/0.387
CYKCYDY 3 × 150SM/50 mm²63.5115100.124/0.387
MGM 109 Type 1012 dimensions
Model and conductor configurationInsulation (mm)Inner sheath (mm)Diameter over inner sheath (mm)Outer sheath (mm)Min. overall diameter (mm)Max. overall diameter (mm)Min. bend radius (mm)Approx. weight (kg/km)Copper weight (kg/km)
MGM 109 Type 1012 2 × 1.5 mm²0.80.87.01.39.713.712432030
MGM 109 Type 1012 2 × 2.5 mm²0.80.88.21.411.115.113639550
MGM 109 Type 1012 2 × 4 mm²0.80.810.21.413.117.115448080
MGM 109 Type 1012 2 × 6 mm²0.80.811.31.514.518.5167620120
MGM 109 Type 1012 2 × 10 mm²1.00.814.01.618.122.1199950220
MGM 109 Type 1012 2 × 16 mm²1.00.815.81.619.923.92161280380
MGM 109 Type 1012 electrical data
Model and conductor configurationContinuous current at 25°C ambient (A)Max. phase/earth conductor DC resistance at 20°C (Ω/km)Max. armour DC resistance at 20°C (Ω/km)
MGM 109 Type 1012 2 × 1.5 mm²1812.120.17
MGM 109 Type 1012 2 × 2.5 mm²267.4112.30
MGM 109 Type 1012 2 × 4 mm²344.617.68
MGM 109 Type 1012 2 × 6 mm²443.085.13
MGM 109 Type 1012 2 × 10 mm²611.833.05
MGM 109 Type 1012 2 × 16 mm²821.151.92
MGM 109 Type 1013 dimensions
Model and conductor configurationInsulation (mm)Inner sheath (mm)Diameter over inner sheath (mm)Outer sheath (mm)Min. overall diameter (mm)Max. overall diameter (mm)Min. bend radius (mm)Approx. weight (kg/km)Copper weight (kg/km)
MGM 109 Type 1013 3 × 1.5 mm²0.80.87.41.49.713.712435045
MGM 109 Type 1013 3 × 2.5 mm²0.80.88.81.411.115.113642075
MGM 109 Type 1013 3 × 4 mm²0.80.810.91.413.117.1154560120
MGM 109 Type 1013 3 × 6 mm²0.80.812.01.514.518.5167780190
MGM 109 Type 1013 3 × 10 mm²1.00.815.01.618.122.11991120310
MGM 109 Type 1013 3 × 16 mm²1.00.816.61.620.724.72231400530
MGM 109 Type 1013 3 × 25 mm²1.21.020.31.725.329.32642150810
MGM 109 Type 1013 3 × 35 mm²1.21.022.51.827.931.928824501160
MGM 109 Type 1013 3 × 50 mm²1.41.026.21.932.236.232634001720
MGM 109 Type 1013 3 × 70 mm²1.41.230.02.036.440.436444202340
MGM 109 Type 1013 3 × 95 mm²1.61.234.82.141.645.641158003200
MGM 109 Type 1013 electrical data
Model and conductor configurationContinuous current at 25°C ambient (A)Max. phase/earth conductor DC resistance at 20°C (Ω/km)Max. armour DC resistance at 20°C (Ω/km)
MGM 109 Type 1013 3 × 1.5 mm²1812.120.17
MGM 109 Type 1013 3 × 2.5 mm²267.4112.30
MGM 109 Type 1013 3 × 4 mm²344.617.68
MGM 109 Type 1013 3 × 6 mm²443.085.13
MGM 109 Type 1013 3 × 10 mm²611.833.05
MGM 109 Type 1013 3 × 16 mm²821.151.92
MGM 109 Type 1013 3 × 25 mm²1080.7271.21
MGM 109 Type 1013 3 × 35 mm²1350.5240.873
MGM 109 Type 1013 3 × 50 mm²1680.3870.645
MGM 109 Type 1013 3 × 70 mm²2070.2680.447
MGM 109 Type 1013 3 × 95 mm²2500.1930.322
MGM 109 Type 1014 dimensions
Model and conductor configurationInsulation (mm)Inner sheath (mm)Diameter over inner sheath (mm)Outer sheath (mm)Min. overall diameter (mm)Max. overall diameter (mm)Min. bend radius (mm)Approx. weight (kg/km)Copper weight (kg/km)
MGM 109 Type 1014 4 × 1.5 mm²0.80.88.11.411.015.013542060
MGM 109 Type 1014 4 × 2.5 mm²0.80.89.51.412.516.5149500100
MGM 109 Type 1014 4 × 4 mm²0.80.811.91.515.819.8179750160
MGM 109 Type 1014 4 × 6 mm²0.80.813.21.517.221.2191820240
MGM 109 Type 1014 4 × 10 mm²1.00.816.51.620.824.82241350400
MGM 109 Type 1014 4 × 16 mm²1.01.018.71.723.927.92521900660
MGM 109 Type 1014 4 × 25 mm²1.21.022.61.828.032.028826101050
MGM 109 Type 1014 4 × 35 mm²1.21.025.01.930.634.631231001460
MGM 109 Type 1014 4 × 50 mm²1.41.229.62.036.240.236243002090
MGM 109 Type 1014 4 × 70 mm²1.41.233.42.140.244.239854003010
MGM 109 Type 1014 4 × 95 mm²1.61.238.72.245.749.744870004100
MGM 109 Type 1014 electrical data
Model and conductor configurationContinuous current at 25°C ambient (A)Max. phase/earth conductor DC resistance at 20°C (Ω/km)Max. armour DC resistance at 20°C (Ω/km)
MGM 109 Type 1014 4 × 1.5 mm²1812.120.17
MGM 109 Type 1014 4 × 2.5 mm²267.4112.30
MGM 109 Type 1014 4 × 4 mm²344.617.68
MGM 109 Type 1014 4 × 6 mm²443.085.13
MGM 109 Type 1014 4 × 10 mm²611.833.05
MGM 109 Type 1014 4 × 16 mm²821.151.92
MGM 109 Type 1014 4 × 25 mm²1080.7271.21
MGM 109 Type 1014 4 × 35 mm²1350.5240.873
MGM 109 Type 1014 4 × 50 mm²1680.3870.645
MGM 109 Type 1014 4 × 70 mm²2070.2680.447
MGM 109 Type 1014 4 × 95 mm²2500.1930.322
MGM 109 Type 1023 dimensions
Model and conductor configurationInsulation (mm)Inner sheath (mm)Diameter over inner sheath (mm)Outer sheath (mm)Min. overall diameter (mm)Max. overall diameter (mm)Min. bend radius (mm)Approx. weight (kg/km)Copper weight (kg/km)
MGM 109 Type 1023 3 × 1.5 mm²0.80.87.41.49.713.712435045
MGM 109 Type 1023 3 × 2.5 mm²0.80.810.31.516.320.320375075
MGM 109 Type 1023 3 × 4 mm²0.80.812.41.618.622.6226910120
MGM 109 Type 1023 3 × 6 mm²0.80.813.61.621.425.42541300190
MGM 109 Type 1023 3 × 10 mm²1.00.816.51.726.530.53051700310
MGM 109 Type 1023 electrical data
Model and conductor configurationContinuous current at 25°C ambient (A)Max. phase/earth conductor DC resistance at 20°C (Ω/km)Max. armour DC resistance at 20°C (Ω/km)
MGM 109 Type 1023 3 × 1.5 mm²1812.120.17
MGM 109 Type 1023 3 × 2.5 mm²267.419.71
MGM 109 Type 1023 3 × 4 mm²344.616.15
MGM 109 Type 1023 3 × 6 mm²443.084.11
MGM 109 Type 1023 3 × 10 mm²611.832.44
MGM 109 Type 1024 dimensions
Model and conductor configurationInsulation (mm)Inner sheath (mm)Diameter over inner sheath (mm)Outer sheath (mm)Min. overall diameter (mm)Max. overall diameter (mm)Min. bend radius (mm)Approx. weight (kg/km)Copper weight (kg/km)
MGM 109 Type 1024 4 × 1.5 mm²0.80.89.61.515.519.519575060
MGM 109 Type 1024 4 × 2.5 mm²0.80.811.11.517.121.1211850100
MGM 109 Type 1024 4 × 4 mm²0.80.813.41.621.225.22521250160
MGM 109 Type 1024 4 × 6 mm²0.80.814.81.722.826.82681480240
MGM 109 Type 1024 4 × 10 mm²1.00.818.11.826.230.23021980385
MGM 109 Type 1024 electrical data
Model and conductor configurationContinuous current at 25°C ambient (A)Max. phase/earth conductor DC resistance at 20°C (Ω/km)Max. armour DC resistance at 20°C (Ω/km)
MGM 109 Type 1024 4 × 1.5 mm²1812.116.10
MGM 109 Type 1024 4 × 2.5 mm²267.419.71
MGM 109 Type 1024 4 × 4 mm²344.616.15
MGM 109 Type 1024 4 × 6 mm²443.084.11
MGM 109 Type 1024 4 × 10 mm²611.832.44
MGM 109 Type 3013 dimensions
Model and conductor configurationInsulation (mm)Inner sheath (mm)Diameter over inner sheath (mm)Outer sheath (mm)Min. overall diameter (mm)Max. overall diameter (mm)Min. bend radius (mm)Approx. weight (kg/km)Copper weight (kg/km)
MGM 109 Type 3013 3 × 50 mm²2.21.831.22.138.042.037841001600
MGM 109 Type 3013 3 × 70 mm²2.21.834.72.241.545.541051502300
MGM 109 Type 3013 3 × 95 mm²2.21.838.52.345.749.744861503200
MGM 109 Type 3013 3 × 120 mm²2.22.242.52.450.754.749377504000
MGM 109 Type 3013 3 × 150 mm²2.22.246.62.555.059.053190005000
MGM 109 Type 3013 3 × 185 mm²2.22.250.52.658.962.9567105006230
MGM 109 Type 3013 electrical data
Model and conductor configurationContinuous current at 25°C ambient (A)Max. phase/earth conductor DC resistance at 20°C (Ω/km)Max. armour DC resistance at 20°C (Ω/km)
MGM 109 Type 3013 3 × 50 mm²1680.3870.645
MGM 109 Type 3013 3 × 70 mm²2070.2680.447
MGM 109 Type 3013 3 × 95 mm²2500.1930.322
MGM 109 Type 3013 3 × 120 mm²2920.1530.255
MGM 109 Type 3013 3 × 150 mm²3350.1240.207
MGM 109 Type 3013 3 × 185 mm²3820.09910.165
MGM 109 Type 3023 dimensions
Model and conductor configurationInsulation (mm)Inner sheath (mm)Diameter over inner sheath (mm)Outer sheath (mm)Min. overall diameter (mm)Max. overall diameter (mm)Min. bend radius (mm)Approx. weight (kg/km)Copper weight (kg/km)
MGM 109 Type 3023 3 × 16 mm²2.21.622.82.031.935.93592500465
MGM 109 Type 3023 3 × 25 mm²2.21.625.42.034.538.53853000700
MGM 109 Type 3023 3 × 35 mm²2.21.627.62.136.940.940935001010
MGM 109 Type 3023 3 × 50 mm²2.21.831.22.242.346.346346001480
MGM 109 Type 3023 3 × 70 mm²2.21.834.62.345.949.949955502170
MGM 109 Type 3023 3 × 95 mm²2.21.838.52.450.054.054068003070
MGM 109 Type 3023 3 × 120 mm²2.22.242.52.656.460.460485503790
MGM 109 Type 3023 3 × 150 mm²2.22.246.62.760.764.764798004880
MGM 109 Type 3023 3 × 185 mm²2.22.250.52.864.868.8688113506120
MGM 109 Type 3023 3 × 240 mm²2.22.656.62.971.175.1751139508080
MGM 109 Type 3023 3 × 300 mm²2.42.662.43.177.381.38131670010290
MGM 109 Type 3023 3 × 400 mm²2.62.670.43.385.789.78972075013750
MGM 109 Type 3023 electrical data
Model and conductor configurationContinuous current at 25°C ambient (A)Max. phase/earth conductor DC resistance at 20°C (Ω/km)Max. armour DC resistance at 20°C (Ω/km)
MGM 109 Type 3023 3 × 16 mm²821.151.53
MGM 109 Type 3023 3 × 25 mm²1080.7270.97
MGM 109 Type 3023 3 × 35 mm²1350.5240.699
MGM 109 Type 3023 3 × 50 mm²1680.3870.516
MGM 109 Type 3023 3 × 70 mm²2070.2680.357
MGM 109 Type 3023 3 × 95 mm²2500.1930.257
MGM 109 Type 3023 3 × 120 mm²2920.1530.204
MGM 109 Type 3023 3 × 150 mm²3350.1240.165
MGM 109 Type 3023 3 × 185 mm²3820.09910.132
MGM 109 Type 3023 3 × 240 mm²4530.07540.101
MGM 109 Type 3023 3 × 300 mm²5230.06010.0801
MGM 109 Type 3023 3 × 400 mm²6200.04700.0627
MGM 109 Type 3123 dimensions
Model and conductor configurationInsulation (mm)Inner sheath (mm)Diameter over inner sheath (mm)Outer sheath (mm)Min. overall diameter (mm)Max. overall diameter (mm)Min. bend radius (mm)Approx. weight (kg/km)Copper weight (kg/km)
MGM 109 Type 3123 3 × 16 mm²2.21.624.82.033.937.93792500465
MGM 109 Type 3123 3 × 25 mm²2.21.627.42.036.540.54053000700
MGM 109 Type 3123 3 × 35 mm²2.21.629.62.138.942.942935001010
MGM 109 Type 3123 3 × 50 mm²2.21.833.22.244.348.348346001480
MGM 109 Type 3123 3 × 70 mm²2.21.836.62.347.951.951955502170
MGM 109 Type 3123 3 × 95 mm²2.21.840.52.452.056.056068003070
MGM 109 Type 3123 3 × 120 mm²2.22.244.52.658.462.462485503790
MGM 109 Type 3123 3 × 150 mm²2.22.248.62.762.766.766798004880
MGM 109 Type 3123 3 × 185 mm²2.22.252.52.866.870.8708113506120
MGM 109 Type 3123 3 × 240 mm²2.22.658.62.973.177.1771139508080
MGM 109 Type 3123 3 × 300 mm²2.42.664.43.179.383.38331670010290
MGM 109 Type 3123 3 × 400 mm²2.62.672.43.387.791.79172075013750
MGM 109 Type 3123 electrical data
Model and conductor configurationContinuous current at 25°C ambient (A)Max. phase/earth conductor DC resistance at 20°C (Ω/km)Max. armour DC resistance at 20°C (Ω/km)
MGM 109 Type 3123 3 × 16 mm²821.151.53
MGM 109 Type 3123 3 × 25 mm²1080.7270.97
MGM 109 Type 3123 3 × 35 mm²1350.5240.699
MGM 109 Type 3123 3 × 50 mm²1680.3870.516
MGM 109 Type 3123 3 × 70 mm²2070.2680.357
MGM 109 Type 3123 3 × 95 mm²2500.1930.257
MGM 109 Type 3123 3 × 120 mm²2920.1530.204
MGM 109 Type 3123 3 × 150 mm²3350.1240.165
MGM 109 Type 3123 3 × 185 mm²3820.09910.132
MGM 109 Type 3123 3 × 240 mm²4530.07540.101
MGM 109 Type 3123 3 × 300 mm²5230.06010.0801
MGM 109 Type 3123 3 × 400 mm²6200.04700.0627

Model families are separate constructions. A shared voltage or conductor size does not replace the insulation, screen, armour and mine-area selection.

D means the finished cable outside diameter. Check both the permissible bend and the available entry space; the MGM tables give configuration-specific minimum radii in millimetres.

RE denotes a solid round conductor; SM denotes a stranded sector-shaped conductor. In a screened or concentric designation, the value after the slash identifies the specified protective metallic section.

MGM current values use 25°C ambient and maximum DC resistances use 20°C. The Polish current values are route-selection references; apply the actual ambient, grouping and installation correction factors.

The Polish short-circuit values refer to 1 second with the conductor initially at its maximum continuous operating temperature. Coordinate protective-device clearing time with the selected conductor.

Mine-area scope is construction-specific. Include the methane, coal-dust, shaft-support and inspection requirements with the enquiry.

For CYKYDY-J water-exposed routes, provide the water conditions, duration and installation details for selection.

Standards

Standards

Fixed Mining Power Cable — PVC / HEPR, SWA / STA Options standards and test references
Standard or specificationApplication
PN-EN 60228 / EN 60228 / IEC 60228Copper-conductor class and resistance references; use the class specified for the selected construction.
PN-EN 60332-1 / PN-EN 60332-3-24 / IEC 60332-3Polish PVC construction single-cable and category C bunched-cable flame-test references.
ČSN 34 7656 / ČSN 34 7615CYKYDY-J design references.
HD 603.1CYKYDY-J PVC compound references DIV1 and DMV1; CYKCYDY PVC insulation reference DIV6.
VDE 0271 / IEC 60502-2CHKCYDY and CYKCYDY medium voltage design references.
IEC 60332-1-2Single-cable flame-test reference for CYKYDY-J and CHKCYDY.
MGM 109/1983Design reference for Types 1012, 1013, 1014, 1023, 1024, 3013, 3023 and 3123.

IEC 60228 conductor classes and resistance requirements

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.