MINING & TUNNELING CABLES TEBAOFLEX

CHBU Single-Core Rubber Cable, 1, 3 and 6 kV

1-CHBU, 3-CHBU and 6-CHBU flexible single-core cable for electrical interconnections, with Class 5 annealed copper, EPR insulation and chloroprene-rubber sheath. Select the 1, 3 or 6 kV construction and its own dimensional row; listed sizes extend from 25 to 500 mm² across the family.

Product information
SKU
TF-MIN-P1B2-M007
Brand
TEBAOFLEX
Product overview

CHBU cable is a single-core rubber-insulated and sheathed power cable for electrical interconnections in mining and industrial installations. The family comprises 1-CHBU, 3-CHBU and 6-CHBU constructions for 1, 3 and 6 kV respectively. Each uses flexible Class 5 annealed copper, EPR insulation and a chloroprene-rubber outer sheath. Bare or tinned copper and the separator option are specified with the order.

Select the voltage-designated model before choosing conductor area. The listed 1-CHBU and 6-CHBU series cover discrete sizes from 25 to 300 mm², while 3-CHBU extends to 500 mm². Insulation and sheath thicknesses change between the series, so the same copper area can require a different cable entry. The separate specification tables give nominal layer thicknesses, approximate overall diameter and approximate cable mass for each listed configuration.

The single-core construction provides flexibility for routing and equipment connections without adding a separate earth core, metallic screen or armour. Plan the protective-conductor arrangement and mechanical support as part of the circuit. For installations specified as NSGAFÖU single-core rubber cable or single-conductor Type W cable, select the corresponding construction and voltage data. Where a machine connection requires continuous reeling or a screened multicore cable, specify that duty and cable construction separately.

Send the CHBU model, conductor area, bare or tinned copper requirement, circuit conditions, route, termination size and required length with the enquiry. TEBAOFLEX supplies CHBU cable from a 50 m minimum order quantity, with a manufacturing lead time of 7–45 working days. The quotation identifies the selected build and documentation required for the project.

Explore the mining and tunneling cable range for related configurations.

Construction

Construction

The three voltage-designated CHBU models use the same basic single-core material arrangement. Their insulation and sheath thicknesses must be selected from the table for the specified model. The main image represents 3-CHBU 1 × 95 mm² with tinned copper and a polyester separator.

CHBU Single-Core Rubber Cable, 1, 3 and 6 kV construction
ComponentMaterial and construction
ConductorOne Class 5 annealed copper conductor to IEC 60228; bare or tinned copper as specified.
SeparatorPolyester tape or semiconducting tape beneath the insulation, selected with the construction.
InsulationEPR, compound designation 3GI3/IEP; thickness depends on model and conductor area.
Outer sheathChloroprene rubber, compound designation EM2/ON5.
Sheath colourBlack; other colours can be specified.
Core arrangementOne insulated power conductor; no separate earth or pilot core in this construction.
Applications

Applications

Specify CHBU by its complete voltage-designated model, conductor area and installation duty when selecting a single-core electrical interconnection.

  • Single-core electrical interconnections within mining and industrial installations.
  • Connections between electrical equipment where flexible copper, EPR insulation and a chloroprene sheath are specified.
  • Fixed routes requiring the stated single-core construction and environmental properties.
  • Replacement of an identified 1-CHBU, 3-CHBU or 6-CHBU cable after matching voltage, copper area, sheath dimensions and terminations.

For route and construction selection, see the mining and tunneling cable application guide.

For a screened three-core mining connection with a specified trailing or reeling duty, review 6-CHCU mining trailing and reeling cable and its own construction requirements.

Specifications

Specifications

CHBU Single-Core Rubber Cable, 1, 3 and 6 kV technical data
ParameterValue
Model / voltage designation1-CHBU: 1 kV; 3-CHBU: 3 kV; 6-CHBU: 6 kV
Power-core countOne
ConductorClass 5 annealed copper; bare or tinned
Insulation / outer sheathEPR / chloroprene rubber
Listed 1-CHBU sizes25, 50, 70, 95, 120, 150, 185, 240 and 300 mm²
Listed 3-CHBU sizes25, 35, 50, 70, 95, 120, 150, 185, 240, 300 and 500 mm²
Listed 6-CHBU sizes25, 50, 70, 95, 120, 150, 185, 240 and 300 mm²
Temperature range−25°C to +90°C; lowest temperature for fixed installation: −40°C
Environmental characteristicsOil, weather, UV, sunlight, ozone and chemical resistance; state the exposure and required test conditions with the enquiry.
Flame behaviourFlame-retardant construction; specify any required test method and acceptance criteria.
Minimum order quantity50 m
Manufacturing lead time7–45 working days
CHBU voltage and construction selection
Model and configurationVoltage designationListed conductor rangeSelection requirement
1-CHBU single core1 kV25–300 mm²; discrete sizes belowUse the 1-CHBU insulation, sheath and diameter row.
3-CHBU single core3 kV25–500 mm²; discrete sizes belowUse the 3-CHBU insulation, sheath and diameter row.
6-CHBU single core6 kV25–300 mm²; discrete sizes belowUse the 6-CHBU insulation, sheath and diameter row.
1-CHBU — single-core reference dimensions and mass
Model and configurationEPR insulation (mm)Chloroprene sheath (mm)Approx. OD (mm)Approx. mass (kg/km)
1-CHBU 1 × 25 mm²1.41.214.0300
1-CHBU 1 × 50 mm²1.61.216.0600
1-CHBU 1 × 70 mm²1.61.217.0761
1-CHBU 1 × 95 mm²1.81.520.01006
1-CHBU 1 × 120 mm²1.81.521.01230
1-CHBU 1 × 150 mm²2.01.524.01576
1-CHBU 1 × 185 mm²2.21.526.01900
1-CHBU 1 × 240 mm²2.41.527.62376
1-CHBU 1 × 300 mm²2.42.532.02800
3-CHBU — single-core reference dimensions and mass
Model and configurationEPR insulation (mm)Chloroprene sheath (mm)Approx. OD (mm)Approx. mass (kg/km)
3-CHBU 1 × 25 mm²2.21.215.6400
3-CHBU 1 × 35 mm²2.22.416.6542
3-CHBU 1 × 50 mm²2.41.217.6650
3-CHBU 1 × 70 mm²2.41.218.6900
3-CHBU 1 × 95 mm²2.61.521.61200
3-CHBU 1 × 120 mm²2.61.522.61400
3-CHBU 1 × 150 mm²2.81.525.61700
3-CHBU 1 × 185 mm²3.01.527.62000
3-CHBU 1 × 240 mm²3.02.029.82570
3-CHBU 1 × 300 mm²3.42.533.02950
3-CHBU 1 × 500 mm²3.63.043.44990
6-CHBU — single-core reference dimensions and mass
Model and configurationEPR insulation (mm)Chloroprene sheath (mm)Approx. OD (mm)Approx. mass (kg/km)
6-CHBU 1 × 25 mm²3.01.217.2470
6-CHBU 1 × 50 mm²3.01.219.2750
6-CHBU 1 × 70 mm²3.01.220.21000
6-CHBU 1 × 95 mm²3.01.522.41300
6-CHBU 1 × 120 mm²3.01.523.41500
6-CHBU 1 × 150 mm²3.01.526.01800
6-CHBU 1 × 185 mm²3.21.528.02100
6-CHBU 1 × 240 mm²3.42.030.62800
6-CHBU 1 × 300 mm²4.02.535.23300

The 1, 3 and 6 kV values identify separate CHBU constructions. State the required conductor-to-earth and conductor-to-conductor ratings with the circuit specification; these values are not presented as a U₀/U pair.

Dimensions and masses are reference values for the listed model and size. Match the selected construction drawing to the termination, cable entry and route before ordering.

Conductor areas are discrete table entries. Do not interpolate a missing size or transfer a sheath thickness between voltage-designated models.

Choose bare or tinned copper and the polyester or semiconducting separator option with the order. A semiconducting separator is not a separate metallic screen.

Determine current-carrying capacity from the selected conductor, ambient conditions, grouping and installation method. No universal ampacity is assigned to these tables.

Flexibility alone does not define a continuous reeling, trailing, torsion or tensile-duty rating. Include movement, bend radius, tension and support details where these affect the connection.

Standards

Standards

CHBU Single-Core Rubber Cable, 1, 3 and 6 kV standards and test references
Standard or specificationApplication
WT-TF-007:2003Legacy CHBU construction specification associated with the listed 1-CHBU, 3-CHBU and 6-CHBU series.
DIN VDE 0250Construction reference for insulated power-installation cables; the required part and edition should be identified in the project specification.
IEC 60228Class 5 copper conductor reference.
DIN VDE 0207 Part 20EPR insulation compound reference for the listed 3GI3/IEP construction.
DIN VDE 0207 Part 21Rubber sheathing compound reference for the listed EM2/ON5 chloroprene sheath.

Official standards and approval references

These references identify conductor, compound and cable-construction requirements. Specify the applicable parts, editions and tests for the ordered CHBU build.

Certifications and document support

Review our company certificates and document scopes when identifying the documentation required for the quoted construction.

Include the voltage-designated CHBU model, conductor area, copper finish, installation duty and any product-specific approval or test-document requirements. Match acceptance documents to that exact construction and supply scope; a standard reference or company management-system certificate does not establish product approval.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.