Single-Conductor Type W 2000 V Mining Power Cable
Single-conductor Type W 2000 V cable with stranded bare copper, EPDM insulation and polyester reinforcement for portable power. Reference sizes: 8 AWG–500 kcmil. MOQ: 50 m; lead time: 7–45 working days.
TEBAOFLEX single-conductor Type W 2000 V cable provides an individual power lead for portable electrical systems around mines, processing plants and temporary work areas. Its single-core format lets the circuit designer select each power conductor separately and match the lead to the connection arrangement. This page covers the 2 kV Type W construction in sizes from 8 AWG to 500 kcmil, with dimensions for comparing cable entries, connectors and handling space.
A stranded bare copper conductor carries the current beneath EPDM insulation. An open polyester braid sits between the insulation and the black outer jacket, adding mechanical reinforcement without a metallic screen or armour. The construction supports portable power use, while the required conductor size still depends on load, circuit length, installation conditions and the temperature rating of the connected equipment. The listed conductor limits are 90°C in dry service and 75°C in wet service.
Specify the protective earth arrangement separately: this cable contains one insulated power conductor and no integrated ground-check core. Compare multiconductor Type W configurations when several power cores must share a jacket, or Type G-GC cable with grounding and ground-check conductors for circuits requiring that integrated arrangement. For cable reels or routes with repeated movement, include the reel geometry and duty cycle with the enquiry so the application can be assessed. TEBAOFLEX supplies quoted lengths from a 50 m minimum order, with a lead time of 7–45 working days. Send the conductor size, required length and termination details to receive a construction-specific quotation.
Explore the mining and tunneling cable range for related configurations.
Construction
A reinforced single-core construction combines stranded copper, EPDM insulation and a black outer jacket. The polyester braid is a non-metallic reinforcing layer. The main image is a representative construction illustration.
| Component | Material and construction |
|---|---|
| Conductor | One fully annealed, stranded bare copper conductor; 8 AWG–500 kcmil reference sizes. |
| Insulation | EPDM insulation; nominal thickness varies with conductor size as listed below. |
| Reinforcement | Open polyester braid between the insulation and outer jacket. |
| Outer jacket | Black heavy-duty jacket. |
| Circuit arrangement | Single insulated power conductor; protective earth and ground-check circuits are specified separately. |
Applications
For portable power connections where a separate single-core lead is appropriate to the equipment and circuit design.
- Portable power distribution for mine maintenance and temporary work areas.
- Individual power leads between portable equipment and its supply connection.
- Temporary power connections in mineral processing and industrial plant areas.
- Outdoor portable power routes with terminations selected for the exposure conditions.
For route and construction selection, see the Type W, G-GC and SHD-GC selection guide.
Specifications
| Parameter | Value |
|---|---|
| Cable designation | Type W, single conductor |
| Rated voltage | 2000 V |
| Conductor sizes | 8 AWG–500 kcmil; listed sizes only |
| Maximum conductor temperature | 90°C dry; 75°C wet |
| Core insulation | EPDM |
| Mechanical reinforcement | Open polyester braid |
| Outer jacket colour | Black |
| Metallic armour or screen | None |
| Minimum order quantity | 50 m |
| Lead time | 7–45 working days |
| Cable configuration | Copper strands | Nominal insulation (mm) | Nominal cable OD (mm) | Approx. net weight (lb/1000 ft) |
|---|---|---|---|---|
| Type W 1 × 8 AWG | 133 | 1.78 | 12.32 | 150 |
| Type W 1 × 6 AWG | 259 | 1.78 | 14.35 | 214 |
| Type W 1 × 4 AWG | 259 | 1.78 | 15.37 | 277 |
| Type W 1 × 2 AWG | 259 | 1.78 | 17.27 | 387 |
| Type W 1 × 1 AWG | 259 | 2.29 | 19.43 | 485 |
| Type W 1 × 1/0 AWG | 259 | 2.29 | 20.57 | 563 |
| Type W 1 × 2/0 AWG | 259 | 2.29 | 22.48 | 679 |
| Type W 1 × 3/0 AWG | 259 | 2.29 | 23.62 | 809 |
| Type W 1 × 4/0 AWG | 259 | 2.29 | 24.89 | 973 |
| Type W 1 × 250 kcmil | 627 | 2.67 | 26.54 | 1155 |
| Type W 1 × 350 kcmil | 855 | 2.67 | 29.08 | 1492 |
| Type W 1 × 500 kcmil | 1235 | 2.67 | 33.27 | 2048 |
Dimensions and weights are reference values for the listed construction. The quotation and agreed production drawing define the supplied cable.
Choose connector and gland dimensions from the finished cable diameter and the conductor size; these are separate measurements.
Determine permissible current from the complete circuit, installation arrangement, ambient conditions and terminal temperature limits.
Single-core cables require a separately designed protective earth arrangement. Include any ground-monitoring requirement in the enquiry.
For repeated movement or reel use, provide the bend radius, reel dimensions, travel and operating duty before selecting the cable.
Specify order length, conductor size, termination arrangement and delivery destination when requesting a quotation.
Standards
| Standard or specification | Application |
|---|---|
| ICEA S-75-381 / NEMA WC 58 | Design reference for portable and power-feeder cables used in mines and similar applications. |
Official standards and approval references
The current NEMA/ICEA publication is ANSI/NEMA WC 23058/ICEA S-75-381-2025; NEMA WC 58 is the historical designation used in the construction reference above.
- ANSI/NEMA WC 23058 / ICEA S-75-381 — Current standard publication for portable and power-feeder cables used in mines and similar applications.
- MSHA cable flame-resistance and approval-marking requirements — Official requirements for cable flame-resistance approval and the associated identification marking.
Certifications and document support
Review our company certificates and document scopes when identifying the documentation required for the quoted construction.
For an order specifying MSHA identification, provide the required cable type, rated voltage and conductor size so the approval record and marking scope can be checked for that construction. Standards and regulatory references explain the procurement requirements; the applicable certificate or acceptance record identifies the approved product scope.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type W Cable 2000V – Round 4/C, 3/C and Flat Options
A related cable option for a different application or duty profile.
View productDLO Cable | 2 kV Diesel Locomotive Cable, 14 AWG–1111.1 kcmil
A related cable option for a different application or duty profile.
View productType G-GC Cable 2000V Portable Mining Power Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.