Get a Quote
INDUSTRIAL CABLES TEBAOFLEX

NSGAFÖU 1.8/3kV Single-Core Rubber Cable

NSGAFÖU cable rated 1.8/3 kV for protected single-core wiring in switchgear, control cabinets, railway vehicles and buses, with flexible tinned-copper and rubber construction references.

  • Rated voltage Uo/U: 1.8/3 kV
  • Reference test voltage: 6 kV
  • Class 5 fine-stranded tinned copper reference
  • EPR rubber insulation and chlorinated-rubber sheath reference
  • Request size, bend radius, temperature and project standard with the RFQ
SKU: TF-NSGAFOU Category: Tags: Brand:
Product information
SKU
TF-NSGAFOU
Brand
TEBAOFLEX
Product overview

NSGAFÖU Cable for Switchgear and Railway Equipment

NSGAFÖU is a 1.8/3 kV single-core flexible rubber cable used for protected wiring in switchboards, electrical devices, railway vehicles and buses. The designation is also searched as NSGAFOU or NSGAFOEU, so this page keeps the correct NSGAFÖU spelling while covering the common ASCII variants.

Use this cable when the installation needs a flexible, insulated single conductor and the route is dry, enclosed or otherwise mechanically protected. The 1.8/3 kV rating is a cable designation; short-circuit-proof or earth-fault-proof use depends on the complete installation, protection and applicable local rules.

  • Best fit: control cabinets, switchgear, device wiring, rail vehicles and buses.
  • Confirm before ordering: conductor size, bend radius, temperature, oil exposure, marking and required VDE or project evidence.
  • Do not assume: outdoor, wet, direct-burial or unprotected routing approval from the model name alone.

Review the Industrial Cable category for related rubber cables. For a quotation, send the conductor size, route, installation voltage and documentation requirement.

Procurement note: identify the vehicle or switchgear family and the required marking so the supplier can align the quoted build and test file.

Construction

Construction

The NSGAFÖU reference construction is a single-core rubber-insulated cable with a protective outer sheath.

LayerReference construction
ConductorClass 5 fine-stranded tinned copper
InsulationEPR rubber compound, 3GI3 reference
Outer sheathChlorinated rubber compound, 5GM5 reference; black commonly supplied
FormSingle core for enclosed or protected routing

Final conductor cross-section, sheath thickness, outside diameter, marking and colour must be confirmed for the quoted size.

Applications

Applications

  • Switchboards, switchgear and power-distribution equipment
  • Control cabinets, machines and electrical devices
  • Railway vehicles and buses
  • Ducts, tubes, conduits and closed installation channels
  • Bundled or movable-part connections where the installation is protected

Type-reference literature describes short-circuit-proof use in selected switching and distribution arrangements up to 1,000 V. The complete installation, protection and local code must control that decision. For general flexible portable power, compare H07RN-F cable.

Specifications

Specifications

Rated voltage Uo/U1.8/3 kV
Reference test voltage6 kV
ConductorClass 5 fine-stranded tinned copper reference
Insulation / sheathEPR rubber / chlorinated rubber reference
Reference operating temperature-40 to +80 deg C in the cited type data; confirm the ordered compound
Installation temperatureDown to -25 deg C in the cited type data
ConfigurationSingle core; conductor size and diameter by quotation

Confirm current capacity, bend radius, short-circuit duty, cable support and environmental exposure with the project engineer.

Standards

Standards

  • VDE 0250 Part 602 reference for the NSGAFÖU cable type.
  • IEC 60332-1-2 / VDE 0482-332-1-2 flame-propagation test reference where specified.
  • Destination-market VDE, railway, vehicle or switchgear documentation must be stated in the RFQ.

Standards and test references are not a blanket certificate for every size. Request the exact declaration, test report or approval documentation required for the project.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    Optional: attach a cable specification, drawing, data sheet or product image (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG or PNG; maximum 10 MB).

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.