VBbShvng(A)-LS GOST 31996 Steel-Tape Armoured Underground Mine Power Cable

Fixed-installation power cable for underground mine roadways, substations, pump chambers and inclined drifts, designed to GOST 31996: VBbShvng(A)-LS (ВБбШвнг(А)-LS) with copper conductors, PVC insulation, two galvanized steel armour tapes and a low-smoke, reduced-flammability PVC sheath in the нг(А)-LS fire class of GOST 31565. 0.66 kV and 1 kV in 3, 4 and 5-core and 3+1 / 3+2 reduced-neutral layouts.

Product information
SKU
VBBSHVNG-A-LS
Brand
TEBAOFLEX
Product overview

Underground mine substations, pump chambers, conveyor drive houses, workshops and roadway distribution boards need fixed power cable that resists rock fall, crushing and fire spread for years after installation. Mines and plants in Russia, Kazakhstan, Central Asia and other GOST-standard projects specify this duty as VBbShvng(A)-LS (ВБбШвнг(А)-LS), the copper, PVC-insulated, steel-tape armoured cable of GOST 31996 at 0.66 kV and 1 kV.

The designation describes the construction: PVC insulation (V), armour of two galvanized steel tapes (Bb), an extruded PVC hose sheath (Shv) and a low-smoke, reduced-flammability compound in the нг(А)-LS class of GOST 31565, which limits flame spread along bunched cable runs and reduces smoke in confined workings. TEBAOFLEX builds it in equal-core 3, 4 and 5-core versions for 0.66 kV circuits and in 3+1 and 3+2 reduced-neutral layouts up to 3×185+1×95 mm2 for 1 kV distribution.

Steel tape armour gives crush and impact protection but carries no useful tensile load. VBbShvng(A)-LS is therefore laid on cable trays, brackets or hangers and clamped at the intervals required by the mine installation rules; it is not a suspended vertical-shaft cable. For vertical borehole or shaft drops that must carry their own weight, use our self-supporting steel wire armoured borehole cable. Admission for use in gassy coal mines follows the destination mine rules and is confirmed per project.

Explore the mining and tunneling cable range for related configurations.

Construction

VBbShvng(A)-LS 0.66 kV and 1 kV Cable Construction & Armour Structure

The representative horizontal sample shows a VBbShvng(A)-LS 1 kV 3x95+1x50 mm2 cable: three copper phase conductors and one reduced neutral conductor with coloured PVC insulation, an extruded PVC inner bedding, two helically applied galvanized steel tapes and a black low-smoke, reduced-flammability PVC outer hose sheath.

Flat 2D cross-section diagram of VBbShvng(A)-LS armoured mine power cable showing three phase and one reduced neutral PVC-insulated copper conductors, inner PVC bedding, two steel armour tapes and low-smoke PVC outer sheath
VBbShvng(A)-LS cross-section: three phase and one reduced neutral PVC-insulated copper conductors, extruded PVC inner bedding, two galvanized steel armour tapes and low-smoke PVC outer hose.
VBbShvng(A)-LS GOST 31996 Steel-Tape Armoured Underground Mine Power Cable construction
ComponentMaterial and construction
Copper ConductorsClass 1 or Class 2 round or sector-shaped copper conductors to GOST 22483 (IEC 60228), 10 mm2 to 185 mm2 phase cores in the layouts shown, with reduced neutral or protective cores on 3+1 and 3+2 designs.
PVC InsulationReduced-flammability PVC compound insulation with colour identification of phase, neutral and protective cores.
Core Lay-Up and FillersCores laid up with non-hygroscopic fillers where needed to give a round core assembly.
Extruded PVC Inner BeddingLow-smoke, reduced-flammability PVC inner covering forming a round bed for the armour tapes.
Galvanized Steel Tape ArmourTwo helically applied galvanized steel tapes with gap overlap for crush and impact protection; the tapes are not designed to carry suspension load.
нг(А)-LS PVC Outer Hose SheathBlack low-smoke, reduced-flammability PVC hose sheath in the нг(А)-LS class of GOST 31565, with surface marking of designation and size.

VBbShvng(A)-LS Type Designation Breakdown

  • V (first В): PVC core insulation (absence of a leading A indicates copper conductors)
  • Bb (Бб): armour of two helically applied galvanized steel tapes over an extruded PVC inner bedding
  • Shv (Шв): extruded PVC outer hose sheath (выпрессованный ПВХ шланг)
  • ng (нг): reduced flame spread in bunched cable runs
  • (A) ((А)): Category A bunched vertical flame test to IEC 60332-3-22 / GOST 31565-2012
  • -LS: low smoke and gas emission under fire conditions in the нг(А)-LS class of GOST 31565-2012
Applications

VBbShvng(A)-LS Fixed Mine Roadway & Substation Feeder Applications

Specify VBbShvng(A)-LS for fixed routes where the cable is laid on trays or brackets and clamped along its length, not hung free.

VBbShvng(A)-LS steel-tape armoured power cables clamped on cable trays along an underground mine roadway leading to a substation chamber
VBbShvng(A)-LS steel-tape armoured power cables clamped on cable trays along an underground mine roadway to a substation chamber.
  • Underground substations, distribution chambers and main pump chambers at 0.66 kV and 1 kV where bunched cables must meet the нг(А)-LS fire class.
  • Fixed distribution along horizontal roadways and inclined drifts on cable trays, brackets or hangers, clamped at the spacing set by the mine installation rules.
  • Conveyor drive houses, underground workshops and surface plant buildings at GOST-standard metal, potash and coal mines.
  • Feeders between surface substations and portal or adit distribution where a steel-armoured, low-smoke fixed cable is specified.

VBbShvng(A)-LS vs Borehole & Shaft Armoured Drop Cable Selection Boundary

VBbShvng(A)-LS compared with related fixed and shaft-drop armoured mining cables
ModelVoltage & InsulationArmour & Tensile CapabilityBest Fit
VBbShvng(A)-LS (this page)0.66 kV (3–5 core) & 1 kV (3+1 / 3+2), PVCDouble steel tape (Bb), no suspension loadFixed, clamped mine roadways, chambers, substations and drifts
Borehole & Shaft Armoured Cable0.6/1 kV to MV, XLPE or EPRGalvanized steel wire armour (SWA / DWA)Self-supporting vertical borehole and mine shaft drops
CSA TECK90 / HVTECK600 V to 5 kV+, XLPE (CSA C22.2 No. 131)Interlocked aluminium or steel armourCanadian-code mine roadways and vertical shaft feeders
Fixed PVC / HEPR Armoured Cable0.6/1 kV to 3.6/6 kV, PVC or HEPRSWA or STA optionsGeneral IEC / EN fixed underground distribution routes

Two galvanized steel tapes (Bb) protect against radial crushing and impact on clamped horizontal trays and drifts; for vertical shaft or borehole drops, specify steel-wire-armoured self-supporting cable.

Related selection resources

VBbShvng(A)-LS (ВБбШвнг(А)-LS) Frequently Asked Questions

What does the designation VBbShvng(A)-LS (ВБбШвнг(А)-LS) stand for?

V indicates PVC core insulation (with copper conductors, as there is no leading A); Bb indicates armour of two helically applied galvanized steel tapes; Shv indicates an extruded PVC outer hose sheath; and нг(А)-LS denotes Category A reduced flame spread in bunched runs with low smoke and gas emission to GOST 31565-2012.

Which voltage ratings and core layouts are covered on this page?

We supply 0.66 kV equal-core 3, 4 and 5-core constructions (10 mm² to 25 mm²) and 1 kV 3+1 and 3+2 reduced-neutral constructions (35 mm² to 185 mm², such as 3x95+1x50 mm², 3x185+1x95 mm² and 3x150+2x70 mm²) designed to GOST 31996-2012.

Can VBbShvng(A)-LS be hung free in a vertical mine shaft or borehole?

No. Galvanized steel tape armour (Bb) provides radial crush and impact protection on trays, brackets and hangers clamped along roadways, chambers and inclined drifts, but it carries no suspension load. For vertical borehole or shaft drops that must support their own weight, specify our self-supporting steel-wire-armoured (SWA / DWA) borehole and shaft drop cable.

What are the minimum order quantity and manufacturing lead time?

The minimum order quantity (MOQ) is 50 m and the manufacturing lead time is 7 to 45 working days, supplied in drum lengths cut to the route.

Specifications

VBbShvng(A)-LS Dimensions, Current Rating & Technical Specifications

VBbShvng(A)-LS Key Specifications

  • Model designation: VBbShvng(A)-LS / ВБбШвнг(А)-LS (0.66 kV and 1 kV fixed steel-tape armoured power cable)
  • Core configurations: 0.66 kV equal-core 3, 4 and 5-core (10–25 mm²); 1 kV 3+1 and 3+2 reduced-neutral (35–185 mm²)
  • Insulation & bedding: Class 1 or Class 2 copper conductors with reduced-flammability PVC insulation and extruded PVC inner bedding
  • Armour & outer sheath: Two helically applied galvanized steel tapes (Bb) under a black нг(А)-LS low-smoke PVC hose sheath
  • Design references: GOST 31996-2012, GOST 31565-2012 (нг(А)-LS), GOST 22483-2012 / IEC 60228, IEC 60332-3-22
VBbShvng(A)-LS GOST 31996 Steel-Tape Armoured Underground Mine Power Cable technical data
ParameterValue
Design standard referenceDesigned to GOST 31996-2012 with the нг(А)-LS fire class of GOST 31565-2012; conductors to GOST 22483 / IEC 60228
Rated voltages and layouts0.66 kV equal-core 3, 4 and 5-core; 1 kV 3+1 and 3+2 reduced-neutral layouts, AC 50 Hz
Fire performanceReduced flame spread in bunched installation (category A) with low smoke and gas emission, per the нг(А)-LS class
Conductor temperature70 C continuous; 160 C short-circuit for max 4 s
Minimum bending radiusAt least 10 x overall diameter; install at ambient temperature not below -15 C without preheating
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7 to 45 working days; drum lengths cut to the route
Selection boundary vs Borehole & Shaft Drop CableChoose VBbShvng(A)-LS for fixed, clamped roadway, chamber and drift routes; choose the self-supporting steel wire armoured borehole cable for vertical borehole or shaft drops that must carry their own weight.

VBbShvng(A)-LS 0.66 kV Equal-Core (3, 4 and 5-Core) Armoured Cable Schedule

GOST 31996 VBbShvng(A)-LS 0.66 kV Equal-Core (3, 4 and 5-Core) Steel-Tape Armoured Cable — Nominal Dimensions and Current Rating
Designation & Core Layout (mm²)Rated VoltageNumber of CoresNom. PVC Insulation (mm)Steel Tape ArmourNom. Overall O.D. (mm)Approx. Mass (kg/km)Current Rating in Air at 25 °C (A)Next step
VBbShvng(A)-LS 3x100.66 kV30.92 x 0.3 mm19.269063Request this size
VBbShvng(A)-LS 3x160.66 kV31.02 x 0.3 mm21.492084Request this size
VBbShvng(A)-LS 3x250.66 kV31.22 x 0.3 mm25.01300112Request this size
VBbShvng(A)-LS 4x100.66 kV40.92 x 0.3 mm20.682063Request this size
VBbShvng(A)-LS 4x160.66 kV41.02 x 0.3 mm23.0111084Request this size
VBbShvng(A)-LS 4x250.66 kV41.22 x 0.3 mm27.21600112Request this size
VBbShvng(A)-LS 5x100.66 kV50.92 x 0.3 mm22.296063Request this size
VBbShvng(A)-LS 5x160.66 kV51.02 x 0.3 mm24.8131084Request this size
VBbShvng(A)-LS 5x250.66 kV51.22 x 0.3 mm29.41900112Request this size

VBbShvng(A)-LS 1 kV 3+1 and 3+2 Reduced-Neutral Armoured Cable Schedule

GOST 31996 VBbShvng(A)-LS 1 kV 3+1 and 3+2 Reduced-Neutral Steel-Tape Armoured Cable — Nominal Dimensions and Current Rating
Designation & Core Layout (mm²)Rated VoltagePhase Conductor (mm²)Reduced Neutral / PE (mm²)Nom. PVC Insulation (mm)Steel Tape ArmourNom. Overall O.D. (mm)Approx. Mass (kg/km)Current Rating in Air at 25 °C (A)Next step
VBbShvng(A)-LS 3x35+1x161 kV351x161.22 x 0.3 mm31.22050137Request this size
VBbShvng(A)-LS 3x50+1x251 kV501x251.42 x 0.5 mm35.42750167Request this size
VBbShvng(A)-LS 3x70+1x351 kV701x351.42 x 0.5 mm39.43600211Request this size
VBbShvng(A)-LS 3x95+1x501 kV951x501.62 x 0.5 mm44.24750257Request this size
VBbShvng(A)-LS 3x120+1x701 kV1201x701.62 x 0.5 mm48.05900300Request this size
VBbShvng(A)-LS 3x150+1x701 kV1501x701.82 x 0.5 mm52.47050346Request this size
VBbShvng(A)-LS 3x185+1x951 kV1851x952.02 x 0.5 mm57.28650397Request this size
VBbShvng(A)-LS 3x95+2x501 kV952x501.62 x 0.5 mm46.85300257Request this size
VBbShvng(A)-LS 3x150+2x701 kV1502x701.82 x 0.5 mm55.67900346Request this size

Dimensions, masses and current ratings are nominal reference values for a single cable in air at 25 C; order values are confirmed on the quotation drawing.

Steel tape armour is not a tensile member: clamp the cable along trays, brackets or hangers at the spacing required by the mine installation rules, and state route gradient and any vertical sections when requesting a quotation.

ASCII part references for BOM and ERP entry: VBbShvng(A)-LS 3x10, VBbShvng(A)-LS 3x16, VBbShvng(A)-LS 3x25, VBbShvng(A)-LS 4x10, VBbShvng(A)-LS 4x16, VBbShvng(A)-LS 4x25, VBbShvng(A)-LS 5x10, VBbShvng(A)-LS 5x16, VBbShvng(A)-LS 5x25, VBbShvng(A)-LS 3x35+1x16, VBbShvng(A)-LS 3x50+1x25, VBbShvng(A)-LS 3x70+1x35, VBbShvng(A)-LS 3x95+1x50, VBbShvng(A)-LS 3x120+1x70, VBbShvng(A)-LS 3x150+1x70, VBbShvng(A)-LS 3x185+1x95, VBbShvng(A)-LS 3x95+2x50, VBbShvng(A)-LS 3x150+2x70.

Standards

VBbShvng(A)-LS Standards & Test References (GOST 31996-2012, GOST 31565-2012)

VBbShvng(A)-LS GOST 31996 Steel-Tape Armoured Underground Mine Power Cable standards and test references
Standard or specificationApplication
GOST 31996-2012Power cables with plastic insulation for rated voltages 0.66, 1 and 3 kV (VBbShvng(A)-LS construction and tests).
GOST 31565-2012Fire hazard classification of cable products, including the нг(А)-LS reduced flame spread and low smoke class.
GOST 22483-2012 / IEC 60228Conductors of insulated cables: conductor classes and maximum DC resistance.
IEC 60332-3-22Vertical flame spread test of bunched cables, category A, the bunched-cable reference behind the (A) category.

Certifications and document support

TEBAOFLEX company certificates and quality system documentation

IEC Webstore — IEC 60228 conductor and IEC 60332-3-22 bunched-cable flame test publications (international references)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.