NTSKCGWÖU KON 0.6/1 (1.2) kV Mining Loader Cable with Split Concentric Earth
Heavy-duty 0.6/1 (1.2) kV trailing and reeling cable based on DIN VDE 0250-813 for LHD loaders, shuttle cars and mobile haulage: three power cores plus three KON units, each a 1.5 mm2 EPR pilot core inside a concentric split tinned-copper earth screen, around a central aramid element, with an anti-torsion braid between 5GM5 polychloroprene sheaths. Three configurations from 3×16 to 3×50 mm2.
Underground LHD loaders, shuttle cars and mobile face haulage machines drag and reel their power cable thousands of times, and the earth and pilot circuits are what keep the protection system aware of cable damage. NTSKCGWÖU KON is a 0.6/1 kV (Um 1.2 kV) mining loader cable based on DIN VDE 0250-813 that rearranges those protective circuits: instead of a separate earth core and two pilot cores, it carries three concentric KON units in the interstices between the three power cores.
Each KON unit is a 1.5 mm2 EPR-insulated pilot core surrounded by a concentric screen of tinned copper wires that forms one third of the split earth conductor, 16/3 mm2 or 25/3 mm2. The power cores and KON units are laid around a central aramid tension-relief element, and an anti-torsion textile braid sits between the inner and outer heavy-duty polychloroprene sheaths of type 5GM5. Three configurations are offered: 3×16+3x(1.5 KON+16/3 KON), 3×25+3x(1.5 KON+25/3 KON) and 3×50+3x(1.5 KON+25/3 KON) mm2.
The reference catalogue for this construction contains two inconsistencies: its text gives a minimum bending radius of 2.3 x D while its mechanical table gives 4 x D, and its 50 mm2 resistance of 0.565 Ω/km matches a 35 mm2 conductor rather than the 0.393 Ω/km maximum for a tinned Class 5 50 mm2 conductor in IEC 60228. TEBAOFLEX builds to the IEC 60228 conductor values and confirms bending radius and all final data on the factory datasheet at order stage.
Explore the mining and tunneling cable range for related configurations.
NTSKCGWÖU KON (NTSKCGWOU KON) 0.6/1 kV Loader Cable Construction & KON Units
The representative horizontal sample shows NTSKCGWÖU KON 3x25+3x(1.5 KON+25/3 KON) mm2: three tinned Class 5 copper power cores with EPR insulation, three KON units with a 1.5 mm2 pilot core inside a concentric tinned-copper earth screen, a central aramid element, an inner 5GM5 sheath, an anti-torsion textile braid and an outer 5GM5 polychloroprene sheath.

| Component | Material and construction |
|---|---|
| Tinned Class 5 Copper Power Conductors | Three tinned annealed copper conductors to IEC 60228 Class 5, 16, 25 or 50 mm2. |
| EPR Insulation | Ethylene propylene rubber insulation on power cores and KON pilot cores, 90 C continuous. |
| KON Pilot and Split Earth Units | Three interstitial units, each a 1.5 mm2 EPR-insulated pilot core with a concentric screen of tinned copper wires forming one third of the earth conductor (16/3 or 25/3 mm2). |
| Central Aramid Element | Aramid tension-relief core in the centre of the lay-up to limit elongation under reeling and trailing load. |
| Inner Sheath and Anti-Torsion Braid | Inner polychloroprene sheath type 5GM5 with an embedded anti-torsion textile braid. |
| Outer 5GM5 Sheath | Heavy-duty polychloroprene outer sheath type 5GM5, resistant to abrasion, oil and weather. |
NTSKCGWÖU KON Type Designation Breakdown
- NTSKCGWÖU: heavy-duty mining trailing and reeling cable type based on DIN VDE 0250-813
- N: standard type to DIN VDE designations
- W: heat-resistant elastomer for 90 °C conductor temperature
- Ö: oil-resistant outer sheath
- U: flame-retardant sheath
- KON: three concentric pilot and split earth units in the interstices
NTSKCGWÖU KON LHD Loader & Shuttle Car Applications
Specify NTSKCGWÖU KON where the machine protection scheme uses concentric pilot and split earth units rather than separate cores.

- Underground LHD loaders (scooptrams) with cable reels on 0.6/1 kV supplies.
- Shuttle cars and mobile face haulage equipment where the cable is repeatedly reeled and dragged.
- Mobile machines whose pilot-monitoring relays are set up for three concentric KON pilot and earth units.
- Replacement of in-service KON-type loader cable in the three verified configurations, with final data confirmed on the factory datasheet.
NTSKCGWÖU KON vs NTSKCGWÖU, (N)TMH3S and Trackless Scoop Cable Selection Boundary
| Product | Core arrangement | Earth and pilot | Sheath | Best fit |
|---|---|---|---|---|
| NTSKCGWÖU KON (this page) | 3 power + 3 KON units | Concentric split earth around each 1.5 mm² pilot | 5GM5 double sheath with braid | Loaders using concentric KON protection |
| NTSKCGWÖU 0.6/1 (1.2) kV Mining Loader Cable | 3 power + 1 earth + 2 pilot | Separate earth core and two pilot cores | 5GM5 double sheath with braid | Standard NTSKCGWÖU loader duty |
| (N)TMH3S 0.6/1 kV TPU Mining Reeling Cable | Per (N)TMH3S construction | Per (N)TMH3S construction | TPU | Reeling duty needing a TPU sheath |
| Trackless Scoop 640/1100 V Mining Cable | Per 640/1100 V scoop construction | Per scoop construction | Heavy-duty elastomer | 640/1100 V trackless scoop machines |
KON and standard NTSKCGWÖU constructions are not interchangeable without checking the machine pilot-monitoring relay and gland arrangement.
Related selection resources
- Mining and tunneling cable engineering solutions
- Trackless mining cable selection guide: LHD scooptrams, drill jumbos and underground specs
- NTSKCGWÖU 0.6/1 (1.2) kV Mining Loader Cable
- (N)TMH3S 0.6/1 kV TPU Mining Reeling Cable
- Trackless Scoop 640/1100 V Mining Cable
NTSKCGWÖU KON (NTSKCGWOU KON) Frequently Asked Questions
What does KON mean on NTSKCGWÖU KON?
KON refers to the concentric units in the interstices: each is a 1.5 mm2 EPR-insulated pilot core surrounded by a concentric screen of tinned copper wires that forms one third of the split earth conductor.
Which configurations are available?
Three: 3x16+3x(1.5 KON+16/3 KON), 3x25+3x(1.5 KON+25/3 KON) and 3x50+3x(1.5 KON+25/3 KON) mm2.
Why does the page mention catalogue discrepancies?
The reference catalogue gives 2.3 x D and 4 x D for bending radius and prints a 50 mm2 resistance that matches 35 mm2. TEBAOFLEX applies IEC 60228 conductor values and confirms bending radius and final data on the factory datasheet.
What are the MOQ and lead time?
The minimum order quantity is 50 m and the manufacturing lead time is 7 to 45 working days, depending on configuration and quantity.
NTSKCGWÖU KON Configurations, Conductor Resistance & Technical Specifications
NTSKCGWÖU KON Key Specifications
- Voltage: 0.6/1 kV, Um 1.2 kV
- Configurations: 3x16, 3x25 and 3x50 mm² with three KON units
- KON unit: 1.5 mm² pilot inside a concentric split tinned copper earth
- Sheath: Double 5GM5 polychloroprene with anti-torsion braid
- Supply: MOQ 50 m; 7 to 45 working days
| Parameter | Value |
|---|---|
| Design standard reference | Based on DIN VDE 0250-813; conductors to IEC 60228 Class 5 (tinned) |
| Rated voltage | 0.6/1 kV, Um 1.2 kV |
| Verified configurations | 3x16+3x(1.5 KON+16/3 KON), 3x25+3x(1.5 KON+25/3 KON) and 3x50+3x(1.5 KON+25/3 KON) mm2 only |
| KON construction | 1.5 mm2 EPR pilot core inside a concentric split earth screen of tinned copper wires, three units per cable |
| Catalogue discrepancy note | Reference text 2.3 x D vs table 4 x D bending radius; reference 0.565 Ω/km for 50 mm2 matches 35 mm2; IEC 60228 values applied and confirmed on the factory datasheet |
| Commercial supply terms | Minimum order quantity 50 m; manufacturing lead time 7 to 45 working days; final dimensions confirmed on the factory datasheet |
| Selection boundary vs standard NTSKCGWÖU | Choose NTSKCGWÖU KON for three concentric pilot and split earth units; choose standard NTSKCGWÖU for 3 power cores, 1 earth core and 2 separate pilot cores. |
NTSKCGWÖU KON Verified Configurations
| Configuration (mm²) | Power Cores (mm²) | KON Pilot Cores (mm²) | Split Earth (mm²) | Max. Resistance Power Core at 20 °C (Ω/km) | Max. Resistance Pilot Core at 20 °C (Ω/km) | Nom. O.D. and Mass | Next step |
|---|---|---|---|---|---|---|---|
| 3x16 + 3x(1.5 KON + 16/3 KON) | 3x16 | 3x1.5 | 16 total (3 x 5.33) | 1.24 | 13.7 | Per factory datasheet | Request this size |
| 3x25 + 3x(1.5 KON + 25/3 KON) | 3x25 | 3x1.5 | 25 total (3 x 8.33) | 0.795 | 13.7 | Per factory datasheet | Request this size |
| 3x50 + 3x(1.5 KON + 25/3 KON) | 3x50 | 3x1.5 | 25 total (3 x 8.33) | 0.393 | 13.7 | Per factory datasheet | Request this size |
NTSKCGWÖU KON Construction and Rating Parameters
| Parameter | Value |
|---|---|
| Rated voltage U0/U (Um) | 0.6/1 kV (1.2 kV) |
| Reference standard | DIN VDE 0250-813 |
| Conductors | Tinned annealed copper, IEC 60228 Class 5 |
| Insulation | EPR on power cores and KON pilot cores |
| KON unit | 1.5 mm² EPR-insulated pilot core with a concentric split earth screen of tinned copper wires |
| Central element | Aramid tension-relief core |
| Reinforcement | Anti-torsion textile braid between inner and outer sheaths |
| Sheaths | Heavy-duty polychloroprene type 5GM5, inner and outer |
| Max conductor temperature | 90 °C continuous |
| Minimum bending radius | Reference catalogue gives 2.3 x D in text and 4 x D in its table; confirmed on the factory datasheet (plan with at least 4 x D) |
The reference catalogue prints 0.565 Ω/km for the 50 mm2 conductor; that is the IEC 60228 Class 5 tinned maximum for 35 mm2. TEBAOFLEX applies 0.393 Ω/km for 50 mm2 and confirms the conductor on the factory datasheet.
The reference catalogue gives a minimum bending radius of 2.3 x D in its text and 4 x D in its mechanical table; plan reels and guides with at least 4 x D until the factory datasheet confirms the value for the ordered configuration.
ASCII part references for BOM and ERP entry: NTSKCGWOU KON 3x16+3x(1.5+16/3), NTSKCGWOU KON 3x25+3x(1.5+25/3), NTSKCGWOU KON 3x50+3x(1.5+25/3).
NTSKCGWÖU KON Standards & Test References (DIN VDE 0250-813, IEC 60228)
| Standard or specification | Application |
|---|---|
| DIN VDE 0250-813 | Rubber-insulated flexible mining cables for underground use, the construction basis for NTSKCGWÖU types. |
| IEC 60228 | Conductors of insulated cables: Class 5 flexible tinned copper conductors and maximum DC resistance. |
| DIN VDE 0207 | Insulating and sheathing compounds for cables, including EPR insulation and 5GM5 polychloroprene sheath types. |
| IEC 60332-1-2 | Vertical flame propagation test for a single insulated wire or cable. |
Certifications and document support
TEBAOFLEX company certificates and quality system documentation
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
NTSKCGWÖU 0.6/1 (1.2) kV Mining Loader Cable
A related cable option for a different application or duty profile.
View product(N)TMH3S 0.6/1 kV TPU Mining Reeling Cable
A related cable option for a different application or duty profile.
View productTrackless Scoop 640/1100 V Mining Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.