MINING & TUNNELING CABLES TEBAOFLEX

PSKD (2–24 Fibres) Aramid-Reinforced Polyurethane Tactical & Emergency Mine Fibre Optic Cable

PSKD (also designated PSKD 2-24 Optical Fibre to TT1-1717/2/0) is an indoor-outdoor non-metallic tactical mine fibre optic cable combining 2 to 24 tight-buffered 0.9 mm optical fibres (soft acrylic inner layer and polyamide outer layer), double aramid yarn reinforcement and dual black zero-halogen flame-retardant polyurethane sheaths rated for 2500 N dynamic tension and -55 °C to +85 °C operation.

Product information
SKU
PL-PSKD-2-24F
Brand
TEBAOFLEX
Product overview

Advancing longwall faces, mobile drilling jumbos, geological exploration crews and underground mine rescue teams need an optical link that can be paid out from portable reels, stepped on by boots and equipment, and recovered for reuse without fibre breakage. PSKD, built to works specification TT1-1717/2/0, is the non-metallic tactical fibre optic cable engineered for that repeated winding and unwinding duty.

Each ITU-T G.652D single-mode (or specified multimode) fibre is protected by a two-layer 0.9 mm tight buffer consisting of a soft acrylic polymer inner coating and a tough polyamide outer jacket, colour-coded to IEC 60304 (with single or double stripes above 12 fibres). Double dielectric aramid yarn layers provide a 2500 N installation tensile rating and 1250 N operating rating while keeping total cable weight between 24 kg/km (2F, 5.8 mm O.D.) and 66 kg/km (24F, 9.5 mm O.D.). Both the inner sheath (0.5 mm min spot, 0.6 mm average) and outer sheath (0.5 mm min spot, 0.6 mm average) are extruded from black zero-halogen flame-retardant polyurethane that stays flexible down to -55 °C.

Under PN-EN 187000:2001 testing, PSKD withstands 3 kN crush for 15 minutes (Method 504), 100 impacts of 10 Nm (Method 505), 2000 repeat-bending cycles at 60 N (Method 507) and 20 full 360-degree torsion cycles (Method 508). Because PSKD is fully dielectric, it can be routed directly alongside power cables without induced voltage hazard. Choose ZW-(QG)GNOTKSdD when a heavier 18–19 mm machine-mounted cable with FRP rods (6000 N) is needed, or YOTKGtsDFoyn for fixed steel-wire-armoured shaft backbones.

Explore the mining and tunneling cable range for related configurations.

Construction

PSKD (2–24F) Tactical Mine Fibre Optic Cable Construction & Layer Structure

The representative horizontal sample shows PSKD 12F (7.1 mm O.D.): twelve 0.9 mm tight-buffered optical fibres colour-coded to IEC 60304, double dielectric aramid yarn reinforcement layers, a black extruded polyurethane inner sheath and an abrasion-resistant black zero-halogen polyurethane outer sheath.

Flat 2D cross-section diagram of PSKD tactical mine fibre optic cable showing 0.9 mm acrylic/polyamide tight-buffered fibres, double aramid yarn reinforcement, black polyurethane inner sheath and black zero-halogen polyurethane outer sheath
PSKD cross-section: 0.9 mm tight buffers, double aramid reinforcement and inner/outer polyurethane jackets.
PSKD (2–24 Fibres) Aramid-Reinforced Polyurethane Tactical & Emergency Mine Fibre Optic Cable construction
ComponentMaterial and construction
Optical Fibres2, 4, 6, 8, 12, 18 or 24 optical fibres to ITU-T G.652D (max. attenuation 0.5 dB/km at 1310 nm and 0.35 dB/km at 1550 nm) or customer-specified multimode/single-mode grade.
Dual-Layer 0.9 mm Tight BufferSoft acrylic polymer inner coating and polyamide outer jacket (0.9 mm diameter), colour-coded to IEC 60304 (red, green, blue, white, violet, orange, grey, yellow, brown, pink, black, turquoise; striped above 12F).
Double Aramid Yarn ReinforcementTwo dielectric aramid yarn layers providing 2500 N dynamic and 1250 N static tensile capacity with zero metallic elements.
Polyurethane Inner SheathBlack extruded polyurethane inner jacket (minimum spot thickness 0.5 mm, average thickness 0.6 mm).
Zero-Halogen Polyurethane Outer SheathBlack UV-, oil-, chemical- and abrasion-resistant flame-retardant zero-halogen polyurethane outer jacket (minimum spot 0.5 mm, average 0.6 mm).

PSKD Type Designation & Construction Breakdown

  • P: field / tactical deployable optical cable
  • S: optical fibre core (ITU-T G.652D or specified multimode)
  • K: tight-buffered 0.9 mm optical fibre construction (soft acrylic inner, polyamide outer)
  • D: double dielectric aramid yarn reinforcement under dual zero-halogen polyurethane sheaths
Applications

PSKD (2–24F) Tactical & Emergency Mine Fibre Optic Applications

Deploy PSKD wherever optical links are frequently wound, unwound, relocated or exposed to sub-zero surface and underground mining conditions.

PSKD tactical polyurethane fibre optic cable deployed from a portable field reel along an underground mine gallery for emergency and geological data transmission
PSKD tactical fibre optic cable paid out from a portable reel in an underground mine heading.
  • Tactical deployable reels for underground mine emergency rescue, post-blast inspection and temporary longwall face telemetry.
  • Geological, geophysical and archaeological field exploration links requiring ultralight 24 to 66 kg/km reels and -40 °C cold-weather deployment.
  • Mobile mining machinery, automation skids and temporary camera/LiDAR links exposed to vibration, oil, chemical splash and repeated flexing.
  • Direct installation alongside high-voltage mining power cables where a 100% dielectric, EMI-immune optical path is required.

PSKD vs ZW-(QG)GNOTKSdD and YOTKGtsDFoyn Selection Boundary

PSKD compared with related mining and reeling fibre optic cables
ModelFibre count & bufferReinforcement & jacketBest fit
PSKD (this page)2 to 24F, 0.9 mm tight bufferDouble aramid yarns, dual black zero-halogen PU sheaths (5.8-9.5 mm)Portable tactical reels, geological work and mine rescue (-55 to +85 °C)
ZW-(QG)GNOTKSdD4, 6 or 8F, 0.9 mm tight buffer + LSOH moduleFRP rods (1.0 mm) + aramid, TPR inner/outer + PU skin (max. 18-19 mm)Heavy-duty moving parts of mining machines (6000 N dynamic)
YOTKGtsDFoyn / Foyn4 to 144F, 2.4 mm gel-filled loose tubesFRP central rod + aramid, 1.54 mm galvanized steel wires, blue PVC-FRFixed horizontal roadways and vertical mine shafts (up to 12000 N)
MSHA Tight-Buffer Breakout2 to 24F, 2.0 mm sub-unitsAramid yarns, double CPE/TPU flame-retardant jacketMSHA-regulated North American underground mine backbones

PSKD is engineered for lightweight portable deployment (24 to 66 kg/km); use ZW-(QG)GNOTKSdD where heavier rubber-cushioned machine reeling is required.

Related selection resources

PSKD Tactical Mine Fibre Optic Cable Frequently Asked Questions

Why does PSKD use a dual-layer 0.9 mm tight buffer and dual polyurethane sheaths?

The 0.9 mm tight buffer combines a soft acrylic inner layer that isolates the glass fibre from micro-bending stress with a tough polyamide outer skin for direct termination. Around the aramid-reinforced core, two separate extruded zero-halogen polyurethane sheaths (each 0.6 mm average) provide cut, oil and abrasion resistance while keeping the cable flexible down to -55 °C.

How many bending and torsion cycles is PSKD rated to withstand?

Under PN-EN 187000:2001 qualification, PSKD is tested for 2000 repeat-bending cycles at 90 degrees under a 60 N load (Method 507) and 20 axial torsion cycles of 360 degrees (Method 508), plus 100 impacts of 10 Nm (Method 505) and a 3 kN crush load for 15 minutes (Method 504), with attenuation change not exceeding 0.5 dB at 1310 nm (SMF).

How are fibres identified in 18-fibre and 24-fibre PSKD cables?

Fibres 1 to 12 follow the standard IEC 60304 sequence (red, green, blue, white, violet, orange, grey, yellow, brown, pink, black, turquoise). In 18F and 24F builds, fibres above 12 use the same base colours marked with single or double black/contrast stripes.

Can PSKD be supplied with multimode fibres or pre-terminated tactical connectors?

Yes. While ITU-T G.652D single-mode fibre is the baseline reference, OM2/OM3/OM4 multimode fibres can be built into the same 0.9 mm tight-buffer geometry; state the fibre grade, fibre count (2, 4, 6, 8, 12, 18 or 24F) and reel length when requesting a quotation.

Specifications

PSKD Dimensions, Tensile Load, PN-EN 187000 Tests & Technical Specifications

PSKD Key Specifications

  • Fibre counts: 2, 4, 6, 8, 12, 18 and 24 tight-buffered 0.9 mm fibres (ITU-T G.652D or MMF)
  • Sheath system: Dual black zero-halogen flame-retardant polyurethane (inner 0.6 mm avg + outer 0.6 mm avg)
  • Tensile & crush: 2500 N dynamic / 1250 N static tensile load; 3 kN crush (15 min) and 100 x 10 Nm impacts
  • Flexing endurance: 2000 repeat-bending cycles (60 N, 90 deg) and 20 torsion cycles (360 deg) to PN-EN 187000:2001
  • Temperatures: Operating -55 °C to +85 °C; installation -40 °C to +70 °C
PSKD (2–24 Fibres) Aramid-Reinforced Polyurethane Tactical & Emergency Mine Fibre Optic Cable technical data
ParameterValue
Construction referenceTT1-1717/2/0; mechanical qualification to PN-EN 187000:2001 Methods 504, 505, 507 and 508
Fibre counts & buffer2, 4, 6, 8, 12, 18 and 24 fibres; 0.9 mm tight buffer (soft acrylic inner + polyamide outer)
Optical attenuation (G.652D)Max. 0.5 dB/km at 1310 nm; max. 0.35 dB/km at 1550 nm
Tensile & mechanical endurance2500 N dynamic / 1250 N static; 3 kN crush (15 min); 100 x 10 Nm impact; 2000 bending cycles
Temperatures & bending radiusInstallation -40 °C to +70 °C; operating -55 °C to +85 °C; min. bend 85 to 140 mm (dynamic) / 110 to 190 mm (static)
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7 to 45 working days; final values confirmed on the quotation drawing
Selection boundary vs ZW-(QG)GNOTKSdD and YOTKGtsDFoynChoose PSKD for ultralight (5.8-9.5 mm) portable tactical reeling from 2 to 24 fibres; choose ZW-(QG)GNOTKSdD for heavy-wall 4-8F machine-mounted reeling (6000 N) and YOTKGtsDFoyn for steel-wire-armoured fixed mine shaft backbones.

PSKD (TT1-1717/2/0) 2–24 Fibre Dimensional & Tensile Schedule

PSKD (TT1-1717/2/0) Non-Metallic Tactical Mine Fibre Optic Cable — Dimensional & Mechanical Schedule
Cable Designation (Fibres)Tight Buffer Diameter (mm)Outer Diameter (mm)Cable Weight (kg/km)Max. Dynamic Tensile Load (N)Max. Static Tensile Load (N)Min. Dynamic Bending Radius (mm)Min. Static Bending Radius (mm)Next step
PSKD 2F0.95.8242500125085110Request this size
PSKD 4F0.95.8252500125085110Request this size
PSKD 6F0.96.3292500125085110Request this size
PSKD 8F0.96.5322500125090120Request this size
PSKD 12F0.97.13825001250100130Request this size
PSKD 18F0.97.94925001250115155Request this size
PSKD 24F0.99.56625001250140190Request this size

PSKD Mechanical Endurance Qualification (PN-EN 187000:2001)

PSKD Mechanical Endurance Qualification Schedule (PN-EN 187000:2001)
TestStandard & MethodTest ConditionAcceptance Criteria
Crush resistancePN-EN 187000:2001 Method 5043 kN; t = 15 minMax. attenuation change 0.5 dB at 1310 nm (SMF) / 1.0 dB at 1300 nm (MMF); no damage
Impact resistancePN-EN 187000:2001 Method 50510 Nm, 100 impactsMax. attenuation change 0.5 dB at 1310 nm (SMF) / 1.0 dB at 1300 nm (MMF); no damage
Repeat bendingPN-EN 187000:2001 Method 50760 N load, 2000 cycles, 90 degMax. attenuation change 0.5 dB at 1310 nm (SMF) / 1.0 dB at 1300 nm (MMF); no damage
Axial torsionPN-EN 187000:2001 Method 50820 cycles, 360 degMax. attenuation change 0.5 dB at 1310 nm (SMF) / 1.0 dB at 1300 nm (MMF); no damage

Maximum attenuation values (0.5 dB/km at 1310 nm and 0.35 dB/km at 1550 nm) apply to cabled ITU-T G.652D single-mode fibres; multimode (50/125 or 62.5/125 um) or bend-insensitive single-mode fibres can be supplied to the project specification.

Polish and Central European designations and the TT1 / ZN works specifications are cited as construction references; TEBAOFLEX builds to the referenced construction and does not claim a Polish mining admission or third-party approval for it, so state the approval documents your mine requires when requesting a quotation.

ASCII part references for BOM and ERP entry: PSKD 2F, PSKD 4F, PSKD 6F, PSKD 8F, PSKD 12F, PSKD 18F, PSKD 24F.

Standards

PSKD Standards & Test References (TT1-1717/2/0, PN-EN 187000:2001)

PSKD (2–24 Fibres) Aramid-Reinforced Polyurethane Tactical & Emergency Mine Fibre Optic Cable standards and test references
Standard or specificationApplication
TT1-1717/2/0Works construction specification for PSKD 2 to 24 fibre non-metallic double-polyurethane tactical optical cable.
PN-EN 187000:2001Optical fibre cable test methods: Method 504 (3 kN crush), Method 505 (10 Nm impact), Method 507 (repeat bending) and Method 508 (torsion).
ITU-T G.652DStandard single-mode optical fibre attributes used as the baseline optical transmission reference.
IEC 60304Twelve-colour identification code for optical fibres and tight buffer tubes (with stripe coding above 12 fibres).

Certifications and document support

TEBAOFLEX company certificates and quality system documentation

IEC Webstore — IEC 60304 colour coding and IEC 60794 optical fibre cable test publications (international references)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.