PSKD (2–24 Fibres) Aramid-Reinforced Polyurethane Tactical & Emergency Mine Fibre Optic Cable
PSKD (also designated PSKD 2-24 Optical Fibre to TT1-1717/2/0) is an indoor-outdoor non-metallic tactical mine fibre optic cable combining 2 to 24 tight-buffered 0.9 mm optical fibres (soft acrylic inner layer and polyamide outer layer), double aramid yarn reinforcement and dual black zero-halogen flame-retardant polyurethane sheaths rated for 2500 N dynamic tension and -55 °C to +85 °C operation.
Advancing longwall faces, mobile drilling jumbos, geological exploration crews and underground mine rescue teams need an optical link that can be paid out from portable reels, stepped on by boots and equipment, and recovered for reuse without fibre breakage. PSKD, built to works specification TT1-1717/2/0, is the non-metallic tactical fibre optic cable engineered for that repeated winding and unwinding duty.
Each ITU-T G.652D single-mode (or specified multimode) fibre is protected by a two-layer 0.9 mm tight buffer consisting of a soft acrylic polymer inner coating and a tough polyamide outer jacket, colour-coded to IEC 60304 (with single or double stripes above 12 fibres). Double dielectric aramid yarn layers provide a 2500 N installation tensile rating and 1250 N operating rating while keeping total cable weight between 24 kg/km (2F, 5.8 mm O.D.) and 66 kg/km (24F, 9.5 mm O.D.). Both the inner sheath (0.5 mm min spot, 0.6 mm average) and outer sheath (0.5 mm min spot, 0.6 mm average) are extruded from black zero-halogen flame-retardant polyurethane that stays flexible down to -55 °C.
Under PN-EN 187000:2001 testing, PSKD withstands 3 kN crush for 15 minutes (Method 504), 100 impacts of 10 Nm (Method 505), 2000 repeat-bending cycles at 60 N (Method 507) and 20 full 360-degree torsion cycles (Method 508). Because PSKD is fully dielectric, it can be routed directly alongside power cables without induced voltage hazard. Choose ZW-(QG)GNOTKSdD when a heavier 18–19 mm machine-mounted cable with FRP rods (6000 N) is needed, or YOTKGtsDFoyn for fixed steel-wire-armoured shaft backbones.
Explore the mining and tunneling cable range for related configurations.
PSKD (2–24F) Tactical Mine Fibre Optic Cable Construction & Layer Structure
The representative horizontal sample shows PSKD 12F (7.1 mm O.D.): twelve 0.9 mm tight-buffered optical fibres colour-coded to IEC 60304, double dielectric aramid yarn reinforcement layers, a black extruded polyurethane inner sheath and an abrasion-resistant black zero-halogen polyurethane outer sheath.

| Component | Material and construction |
|---|---|
| Optical Fibres | 2, 4, 6, 8, 12, 18 or 24 optical fibres to ITU-T G.652D (max. attenuation 0.5 dB/km at 1310 nm and 0.35 dB/km at 1550 nm) or customer-specified multimode/single-mode grade. |
| Dual-Layer 0.9 mm Tight Buffer | Soft acrylic polymer inner coating and polyamide outer jacket (0.9 mm diameter), colour-coded to IEC 60304 (red, green, blue, white, violet, orange, grey, yellow, brown, pink, black, turquoise; striped above 12F). |
| Double Aramid Yarn Reinforcement | Two dielectric aramid yarn layers providing 2500 N dynamic and 1250 N static tensile capacity with zero metallic elements. |
| Polyurethane Inner Sheath | Black extruded polyurethane inner jacket (minimum spot thickness 0.5 mm, average thickness 0.6 mm). |
| Zero-Halogen Polyurethane Outer Sheath | Black UV-, oil-, chemical- and abrasion-resistant flame-retardant zero-halogen polyurethane outer jacket (minimum spot 0.5 mm, average 0.6 mm). |
PSKD Type Designation & Construction Breakdown
- P: field / tactical deployable optical cable
- S: optical fibre core (ITU-T G.652D or specified multimode)
- K: tight-buffered 0.9 mm optical fibre construction (soft acrylic inner, polyamide outer)
- D: double dielectric aramid yarn reinforcement under dual zero-halogen polyurethane sheaths
PSKD (2–24F) Tactical & Emergency Mine Fibre Optic Applications
Deploy PSKD wherever optical links are frequently wound, unwound, relocated or exposed to sub-zero surface and underground mining conditions.

- Tactical deployable reels for underground mine emergency rescue, post-blast inspection and temporary longwall face telemetry.
- Geological, geophysical and archaeological field exploration links requiring ultralight 24 to 66 kg/km reels and -40 °C cold-weather deployment.
- Mobile mining machinery, automation skids and temporary camera/LiDAR links exposed to vibration, oil, chemical splash and repeated flexing.
- Direct installation alongside high-voltage mining power cables where a 100% dielectric, EMI-immune optical path is required.
PSKD vs ZW-(QG)GNOTKSdD and YOTKGtsDFoyn Selection Boundary
| Model | Fibre count & buffer | Reinforcement & jacket | Best fit |
|---|---|---|---|
| PSKD (this page) | 2 to 24F, 0.9 mm tight buffer | Double aramid yarns, dual black zero-halogen PU sheaths (5.8-9.5 mm) | Portable tactical reels, geological work and mine rescue (-55 to +85 °C) |
| ZW-(QG)GNOTKSdD | 4, 6 or 8F, 0.9 mm tight buffer + LSOH module | FRP rods (1.0 mm) + aramid, TPR inner/outer + PU skin (max. 18-19 mm) | Heavy-duty moving parts of mining machines (6000 N dynamic) |
| YOTKGtsDFoyn / Foyn | 4 to 144F, 2.4 mm gel-filled loose tubes | FRP central rod + aramid, 1.54 mm galvanized steel wires, blue PVC-FR | Fixed horizontal roadways and vertical mine shafts (up to 12000 N) |
| MSHA Tight-Buffer Breakout | 2 to 24F, 2.0 mm sub-units | Aramid yarns, double CPE/TPU flame-retardant jacket | MSHA-regulated North American underground mine backbones |
PSKD is engineered for lightweight portable deployment (24 to 66 kg/km); use ZW-(QG)GNOTKSdD where heavier rubber-cushioned machine reeling is required.
Related selection resources
- Mining and tunneling cable engineering solutions
- Mining cable selection guide: 8 steps for mobile equipment
- Flexible Fibre Optic Cable for Crane Festoon, Reeling and Cable Chains
- MSHA Tight-Buffer Breakout and Electro-Optic Mining Fiber Cable
- MSHA Loose-Tube Mining Fiber Optic Cable (6-144F)
PSKD Tactical Mine Fibre Optic Cable Frequently Asked Questions
Why does PSKD use a dual-layer 0.9 mm tight buffer and dual polyurethane sheaths?
The 0.9 mm tight buffer combines a soft acrylic inner layer that isolates the glass fibre from micro-bending stress with a tough polyamide outer skin for direct termination. Around the aramid-reinforced core, two separate extruded zero-halogen polyurethane sheaths (each 0.6 mm average) provide cut, oil and abrasion resistance while keeping the cable flexible down to -55 °C.
How many bending and torsion cycles is PSKD rated to withstand?
Under PN-EN 187000:2001 qualification, PSKD is tested for 2000 repeat-bending cycles at 90 degrees under a 60 N load (Method 507) and 20 axial torsion cycles of 360 degrees (Method 508), plus 100 impacts of 10 Nm (Method 505) and a 3 kN crush load for 15 minutes (Method 504), with attenuation change not exceeding 0.5 dB at 1310 nm (SMF).
How are fibres identified in 18-fibre and 24-fibre PSKD cables?
Fibres 1 to 12 follow the standard IEC 60304 sequence (red, green, blue, white, violet, orange, grey, yellow, brown, pink, black, turquoise). In 18F and 24F builds, fibres above 12 use the same base colours marked with single or double black/contrast stripes.
Can PSKD be supplied with multimode fibres or pre-terminated tactical connectors?
Yes. While ITU-T G.652D single-mode fibre is the baseline reference, OM2/OM3/OM4 multimode fibres can be built into the same 0.9 mm tight-buffer geometry; state the fibre grade, fibre count (2, 4, 6, 8, 12, 18 or 24F) and reel length when requesting a quotation.
PSKD Dimensions, Tensile Load, PN-EN 187000 Tests & Technical Specifications
PSKD Key Specifications
- Fibre counts: 2, 4, 6, 8, 12, 18 and 24 tight-buffered 0.9 mm fibres (ITU-T G.652D or MMF)
- Sheath system: Dual black zero-halogen flame-retardant polyurethane (inner 0.6 mm avg + outer 0.6 mm avg)
- Tensile & crush: 2500 N dynamic / 1250 N static tensile load; 3 kN crush (15 min) and 100 x 10 Nm impacts
- Flexing endurance: 2000 repeat-bending cycles (60 N, 90 deg) and 20 torsion cycles (360 deg) to PN-EN 187000:2001
- Temperatures: Operating -55 °C to +85 °C; installation -40 °C to +70 °C
| Parameter | Value |
|---|---|
| Construction reference | TT1-1717/2/0; mechanical qualification to PN-EN 187000:2001 Methods 504, 505, 507 and 508 |
| Fibre counts & buffer | 2, 4, 6, 8, 12, 18 and 24 fibres; 0.9 mm tight buffer (soft acrylic inner + polyamide outer) |
| Optical attenuation (G.652D) | Max. 0.5 dB/km at 1310 nm; max. 0.35 dB/km at 1550 nm |
| Tensile & mechanical endurance | 2500 N dynamic / 1250 N static; 3 kN crush (15 min); 100 x 10 Nm impact; 2000 bending cycles |
| Temperatures & bending radius | Installation -40 °C to +70 °C; operating -55 °C to +85 °C; min. bend 85 to 140 mm (dynamic) / 110 to 190 mm (static) |
| Commercial supply terms | Minimum order quantity 50 m; manufacturing lead time 7 to 45 working days; final values confirmed on the quotation drawing |
| Selection boundary vs ZW-(QG)GNOTKSdD and YOTKGtsDFoyn | Choose PSKD for ultralight (5.8-9.5 mm) portable tactical reeling from 2 to 24 fibres; choose ZW-(QG)GNOTKSdD for heavy-wall 4-8F machine-mounted reeling (6000 N) and YOTKGtsDFoyn for steel-wire-armoured fixed mine shaft backbones. |
PSKD (TT1-1717/2/0) 2–24 Fibre Dimensional & Tensile Schedule
| Cable Designation (Fibres) | Tight Buffer Diameter (mm) | Outer Diameter (mm) | Cable Weight (kg/km) | Max. Dynamic Tensile Load (N) | Max. Static Tensile Load (N) | Min. Dynamic Bending Radius (mm) | Min. Static Bending Radius (mm) | Next step |
|---|---|---|---|---|---|---|---|---|
| PSKD 2F | 0.9 | 5.8 | 24 | 2500 | 1250 | 85 | 110 | Request this size |
| PSKD 4F | 0.9 | 5.8 | 25 | 2500 | 1250 | 85 | 110 | Request this size |
| PSKD 6F | 0.9 | 6.3 | 29 | 2500 | 1250 | 85 | 110 | Request this size |
| PSKD 8F | 0.9 | 6.5 | 32 | 2500 | 1250 | 90 | 120 | Request this size |
| PSKD 12F | 0.9 | 7.1 | 38 | 2500 | 1250 | 100 | 130 | Request this size |
| PSKD 18F | 0.9 | 7.9 | 49 | 2500 | 1250 | 115 | 155 | Request this size |
| PSKD 24F | 0.9 | 9.5 | 66 | 2500 | 1250 | 140 | 190 | Request this size |
PSKD Mechanical Endurance Qualification (PN-EN 187000:2001)
| Test | Standard & Method | Test Condition | Acceptance Criteria |
|---|---|---|---|
| Crush resistance | PN-EN 187000:2001 Method 504 | 3 kN; t = 15 min | Max. attenuation change 0.5 dB at 1310 nm (SMF) / 1.0 dB at 1300 nm (MMF); no damage |
| Impact resistance | PN-EN 187000:2001 Method 505 | 10 Nm, 100 impacts | Max. attenuation change 0.5 dB at 1310 nm (SMF) / 1.0 dB at 1300 nm (MMF); no damage |
| Repeat bending | PN-EN 187000:2001 Method 507 | 60 N load, 2000 cycles, 90 deg | Max. attenuation change 0.5 dB at 1310 nm (SMF) / 1.0 dB at 1300 nm (MMF); no damage |
| Axial torsion | PN-EN 187000:2001 Method 508 | 20 cycles, 360 deg | Max. attenuation change 0.5 dB at 1310 nm (SMF) / 1.0 dB at 1300 nm (MMF); no damage |
Maximum attenuation values (0.5 dB/km at 1310 nm and 0.35 dB/km at 1550 nm) apply to cabled ITU-T G.652D single-mode fibres; multimode (50/125 or 62.5/125 um) or bend-insensitive single-mode fibres can be supplied to the project specification.
Polish and Central European designations and the TT1 / ZN works specifications are cited as construction references; TEBAOFLEX builds to the referenced construction and does not claim a Polish mining admission or third-party approval for it, so state the approval documents your mine requires when requesting a quotation.
ASCII part references for BOM and ERP entry: PSKD 2F, PSKD 4F, PSKD 6F, PSKD 8F, PSKD 12F, PSKD 18F, PSKD 24F.
PSKD Standards & Test References (TT1-1717/2/0, PN-EN 187000:2001)
| Standard or specification | Application |
|---|---|
| TT1-1717/2/0 | Works construction specification for PSKD 2 to 24 fibre non-metallic double-polyurethane tactical optical cable. |
| PN-EN 187000:2001 | Optical fibre cable test methods: Method 504 (3 kN crush), Method 505 (10 Nm impact), Method 507 (repeat bending) and Method 508 (torsion). |
| ITU-T G.652D | Standard single-mode optical fibre attributes used as the baseline optical transmission reference. |
| IEC 60304 | Twelve-colour identification code for optical fibres and tight buffer tubes (with stripe coding above 12 fibres). |
Certifications and document support
TEBAOFLEX company certificates and quality system documentation
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-5GM5-MINING-FO Heavy-Duty 5GM5 Rubber Open-Pit Mining & Festoon Fibre Optic Cable
A related cable option for a different application or duty profile.
View productFlexible Fibre Optic Cable for Crane Festoon, Reeling and Cable Chains
A related cable option for a different application or duty profile.
View productMSHA Tight-Buffer Breakout and Electro-Optic Mining Fiber Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.