High Temperature Cables TEBAOFLEX

N2GFAF & (N)2GFAF Silicone Single-Core Wire (DIN VDE 0250-502, 300/300 V)

N2GFAF and (N)2GFAF single-core silicone fixture wires (300/300 V, 2,000 V AC test) are constructed with reference to DIN VDE 0250-502 using IEC 60228 Class 5 tinned copper (-60 °C to +180 °C) or bare copper (-60 °C to +130 °C) conductors from 0.50 mm² to 2.50 mm² and Shore A 70 EI2 silicone rubber insulation.

Product information
SKU
TF-N2GFAF-VDE0250
Brand
TEBAOFLEX
Product overview

N2GFAF and (N)2GFAF single-core silicone wires provide compact 300/300 V internal harness, lamp-holder and appliance wiring built with reference to DIN VDE 0250 Part 502 across five standardized cross-sections (0.50, 0.75, 1.00, 1.50 and 2.50 mm²), holding maximum outside diameter between 2.2 mm and 3.6 mm while passing 2,000 V AC dielectric testing.

European luminaire, commercial catering and domestic heating OEMs specify (N)2GFAF over general-purpose 300/500 V silicone wires because its regulated 0.6 mm to 0.8 mm EI2 silicone wall and 70 +/- 2 Shore A durometer feed reliably through high-speed automated cut-strip-crimp lines and narrow lamp suspension tubes without insulation bunching. Critically, DIN VDE 0250-502 differentiates conductor metallurgy: tinned copper strands operate continuously from -60 °C to +180 °C, whereas bare copper strands must be derated to +130 °C to prevent copper-catalysed thermal oxidation.

Specify (N)2GFAF when German or Italian OEM drawings call for DIN VDE 0250-502 300/300 V luminaire and appliance harness leads; select H03S-K for harmonized EN 50525-2-41 cords, or step up to 300/500 V SiF / H05SJ-K for higher voltage or cross-sections above 2.50 mm² (standard 300 m / 500 m factory spools rather than 50 m cut lengths, 7 to 45 working days).

Explore the high-temperature wire and cable range for related configurations.

Construction

N2GFAF & (N)2GFAF VDE 0250-502 Silicone Wire Construction

TEBAOFLEX manufactures (N)2GFAF single-core wires to the dimensional, capillary stranding and Shore A hardness envelope of DIN VDE 0250-502 for automated European wire-harness production.

Clean 2D engineering cross-section of N2GFAF DIN VDE 0250-502 single-core silicone wire showing fine-stranded Class 5 tinned copper core and concentric Shore A 70 EI2 silicone insulation
N2GFAF cross-section: concentric 0.6 to 0.8 mm EI2 silicone wall over 0.21/0.26 mm Class 5 copper strands per DIN VDE 0250-502.
N2GFAF & (N)2GFAF Silicone Single-Core Wire (DIN VDE 0250-502, 300/300 V) construction
ComponentMaterial and construction
1. Fine-Stranded Copper Conductor (IEC 60228 Class 5)0.21 mm max strand diameter on 0.50 to 1.00 mm² and 0.26 mm max strand diameter on 1.50 to 2.50 mm²: annealed tinned copper (-60 °C to +180 °C, N2GFAF-STA), plain bare copper (-60 °C to +130 °C), or optional nickel-plated copper.
2. High-Durometer EI2 Silicone Rubber InsulationExtruded cross-linked silicone rubber Type EI2 (70 +/- 2 Shore A hardness, 0.6 mm nominal wall on 0.50–1.00 mm², 0.7 mm on 1.50 mm² and 0.8 mm on 2.50 mm²), ozone-, UV- and thermal-shock resistant and halogen-free per IEC 60754-1.
3. Harness Colour CodingAvailable in white, black, red-brown, blue, brown, red, yellow, grey and green-yellow for multi-circuit appliance and lighting loom assembly.

N2GFAF, (N)2GFAF & N2GFAF-STA Designation Breakdown

  • (N) / N: Constructed with reference to German national DIN VDE 0250-502 dimensional and electrical rules
  • 2G: Heat-resistant cross-linked silicone rubber core insulation compound Type EI2
  • FA: Fassungsader — slim-wall luminaire, lamp-holder and internal equipment harness wire (300/300 V)
  • F: Feindraehtig — flexible fine-stranded conductor per IEC 60228 Class 5 (0.50 to 2.50 mm²)
  • -STA / -BC: Tinned copper conductor rated -60 to +180 °C (-STA) versus plain bare copper rated -60 to +130 °C (-BC)
Applications

N2GFAF Luminaire, Catering Oven & Appliance Harness Applications

Use N2GFAF / (N)2GFAF 300/300 V silicone wires in high-volume lighting fixtures, commercial baking equipment and electro-thermal appliance wire harnesses.

Commercial baking oven and industrial luminaire wiring workstation installing N2GFAF 180 C single-core silicone harness leads onto ceramic lamp holders and thermostats
High-temperature luminaire and commercial oven harness assembly using slim-OD N2GFAF 300/300 V silicone leads.
  • Halogen, metal-halide, stage/studio and high-bay industrial luminaire internal leads, lamp holders and ballast compartments.
  • Commercial convection ovens, espresso/coffee boilers, pizza deck ovens, toasters and catering warmers wired with automated crimp harnesses.
  • Thermostats, cartridge heater tails, drying cabinets and HVAC electric duct-heater control looms operating up to +180 °C.
  • Electronic power supplies, UV curing lamps and laboratory instruments requiring slim 2.2 to 3.6 mm OD halogen-free leads.

N2GFAF vs H03S-K vs SiF 300/500 V vs H05SJ-K Silicone Wire

N2GFAF / (N)2GFAF vs H03S-K vs SiF 300/500 V vs H05SJ-K Braided Silicone Wire
Wire FamilyRated Voltage & StandardSize Range & Wall ProfileWhen to Specify
N2GFAF / (N)2GFAF (this page)300/300 V, DIN VDE 0250-502 reference0.50–2.50 mm², slim 0.6–0.8 mm Shore A 70 EI2 wallAutomated luminaire, lamp-holder & commercial appliance harnesses
H03S-K Silicone Wire300/300 V, EN 50525-2-41 harmonized0.50–2.50 mm², CENELEC HAR wall (2.1–3.6 mm OD)Appliances requiring EN 50525-2-41 harmonized cordage code
SiF Silicone Single-Core300/500 V, DIN VDE 0250 reference0.25–150 mm², standard 300/500 V insulation wall500 V control cabinets, motors & power leads above 2.50 mm²
H05SJ-K / SiF/GL Braided Wire300/500 V, EN 50525-2-83 / VDE 02500.50–150 mm², EI2 silicone + varnished fiberglass braidSharp sheet-metal pass-throughs & high-abrasion oven terminals

Select (N)2GFAF tinned copper (+180 °C) whenever European BOMs specify VDE 0250-502 slim-OD fixture wire for automated crimping.

N2GFAF & (N)2GFAF Silicone Harness Wire RFQ Checklist

  • Conductor metallurgy: tinned copper N2GFAF-STA (-60 to +180 °C, recommended), bare copper (-60 to +130 °C) or nickel-plated copper (+200 °C).
  • Cross-section (0.50, 0.75, 1.00, 1.50 or 2.50 mm²) and insulation colour breakdown.
  • Maximum outside diameter window if feeding automatic Komax/Schleuniger crimp applicator guides or narrow lamp tubes.
  • Packaging preference: 300 m / 500 m plastic spools, barrel packs or shrink-wrapped coils for automatic dereeling.
  • Spool count per colour (MOQ 300 m or 500 m standard spool per colour/gauge) and required delivery date (7 to 45 working days).

Related selection resources

N2GFAF & (N)2GFAF VDE 0250-502 Frequently Asked Questions

Why is bare-copper N2GFAF rated +130 °C while tinned-copper N2GFAF is rated +180 °C?

Above +130 °C in air, unprotected bare copper strands rapidly oxidize and form brittle cuprous oxide scales under oxygen-permeable silicone rubber, raising contact resistance; tin-plating the Class 5 strands (N2GFAF-STA) blocks copper oxidation up to +180 °C continuous (+200 °C short-time).

What does the (N) prefix in (N)2GFAF mean on German technical drawings?

In German DIN VDE notation, 2GFAF stands for silicone rubber insulation (2G), luminaire/fixture wire (FA) and fine-stranded Class 5 conductor (F), while placing (N) in parentheses indicates the wire is manufactured with reference to DIN VDE 0250-502 construction dimensions without claiming a VDE mark license.

Is N2GFAF suitable for automatic wire cutting, stripping and terminal crimping machines?

Yes. TEBAOFLEX formulates (N)2GFAF EI2 silicone insulation to a controlled 70 +/- 2 Shore A hardness with concentric 0.6 to 0.8 mm wall thickness so V-blades strip cleanly without gummy elongation or conductor strand nicking.

What is the minimum order quantity for N2GFAF / (N)2GFAF single-core wire?

Standard factory minimum order quantity is one 500 m spool per colour on 0.50, 0.75 and 1.00 mm² sizes and one 300 m or 500 m spool on 1.50 and 2.50 mm² sizes (rather than 50 m cut lengths used on heavy multicore cables), manufactured in 7 to 45 working days.

When should I upgrade from 300/300 V N2GFAF to 300/500 V SiF or H05SJ-K?

Step up from 300/300 V N2GFAF to 300/500 V SiF whenever the circuit phase-to-phase voltage exceeds 300 V or the conductor size exceeds 2.50 mm², and choose fiberglass-braided H05SJ-K if the wire passes through unbushed metal apertures.

Specifications

N2GFAF & (N)2GFAF Dimensional, Resistance & Spool Schedule

N2GFAF Key Voltage, Shore Hardness, Temperature & Spool Summary

  • DIN VDE 0250-502 geometry: Exact 0.6 mm to 0.8 mm EI2 silicone wall schedule keeping overall diameter slim (2.2 mm to 3.6 mm max) for luminaire stems and tight harnesses
  • Conductor finish vs temperature: Tinned copper N2GFAF-STA / (N)2GFAF rated -60 °C to +180 °C; bare copper variant rated -60 °C to +130 °C; nickel-plated copper available to +200 °C
  • High Shore A 70 tear resistance: 70 +/- 2 Shore A cross-linked EI2 silicone compound feeds smoothly through automatic wire-cutting, stripping and terminal-crimping machines
  • 2,000 V AC dielectric safety: 300/300 V working rating verified by 2,000 V AC 50 Hz spark and dielectric testing despite compact luminaire-grade outside diameters
  • Factory spool MOQ: Supplied on 500 m standard spools (0.50–1.00 mm²) or 300 m / 500 m spools (1.50–2.50 mm²) per colour in 7 to 45 working days
N2GFAF & (N)2GFAF Silicone Single-Core Wire (DIN VDE 0250-502, 300/300 V) technical data
ParameterValue
Rated voltage300/300 V AC (Uo/U) working voltage with 2000 V AC 50 Hz routine test voltage with reference to DIN VDE 0250-502
Cross-section and strand geometry1x0.50, 1x0.75, 1x1.00, 1x1.50 and 1x2.50 mm2 IEC 60228 Class 5 flexible strands (0.21 mm or 0.26 mm capillary wire)
Conductor finish and temperature-60 C to +180 C continuous with tinned copper conductor; -60 C to +130 C continuous with bare copper conductor
Insulation compound and hardnessCross-linked silicone rubber Type EI2 (0.6 to 0.8 mm nominal wall, 70 plus or minus 2 Shore A) for automated stripping
Standard spool MOQ and lead time500 m standard spools (0.50 to 1.00 mm2) or 300 m / 500 m spools (1.50 to 2.50 mm2) per colour in 7 to 45 working days
Minimum bending radius5x outer diameter for fixed internal luminaire/appliance routing and 10x outer diameter during harness flexing
Halogen-free and ageing stabilityHalogen-free per IEC 60754-1/2 with high resistance to UV, ozone, thermal shock and solder-iron pullback

N2GFAF & (N)2GFAF Tinned (+180 °C) vs Bare (+130 °C) Copper Dimensional Schedule

N2GFAF & (N)2GFAF Silicone Single-Core Wire — DIN VDE 0250-502 Dimensional, Resistance & Spool Schedule
Model & Conductor VariantMax Strand Ø (mm)Conductor Ø (mm)EI2 Wall (mm)Nominal – Max OD (mm)Max DC Res. at 20 °C (Ω/km)Cu Index (kg/km) | Put-UpNext step
N2GFAF 1x0.50 mm² Tinned Cu (+180 °C)0.210.900.62.10 – 2.2040.14.8 | 500 m spoolRequest this size
N2GFAF 1x0.75 mm² Tinned Cu (+180 °C)0.211.100.62.25 – 2.4026.77.2 | 500 m spoolRequest this size
N2GFAF 1x1.00 mm² Tinned Cu (+180 °C)0.211.200.62.40 – 2.5020.09.6 | 500 m spoolRequest this size
N2GFAF 1x1.50 mm² Tinned Cu (+180 °C)0.261.500.72.80 – 3.0013.714.4 | 500 m / 300 mRequest this size
N2GFAF 1x2.50 mm² Tinned Cu (+180 °C)0.261.900.83.40 – 3.608.2124.0 | 300 m / 500 mRequest this size
N2GFAF-BC 1x0.50 mm² Bare Cu (+130 °C)0.210.900.62.10 – 2.2039.04.8 | 500 m spoolRequest this size
N2GFAF-BC 1x0.75 mm² Bare Cu (+130 °C)0.211.100.62.25 – 2.4026.07.2 | 500 m spoolRequest this size
N2GFAF-BC 1x1.00 mm² Bare Cu (+130 °C)0.211.200.62.40 – 2.5019.59.6 | 500 m spoolRequest this size
N2GFAF-BC 1x1.50 mm² Bare Cu (+130 °C)0.261.500.72.80 – 3.0013.314.4 | 500 m / 300 mRequest this size
N2GFAF-BC 1x2.50 mm² Bare Cu (+130 °C)0.261.900.83.40 – 3.607.9824.0 | 300 m / 500 mRequest this size

In German cable nomenclature, the bracketed prefix (N)2GFAF denotes construction and dimensional geometry built with reference to DIN VDE 0250-502 (rather than a VDE mark license); final conductor stranding, OD tolerance and Shore hardness are confirmed on the quotation drawing.

Always specify tinned copper (N2GFAF-STA / tinned (N)2GFAF) when continuous conductor temperature exceeds +130 °C up to +180 °C; bare copper is intended for +130 °C max welding/brazing or specialized weld-tab terminations.

Because 0.50 to 2.50 mm² luminaire hook-up wires run on continuous high-speed extrusion lines, minimum order quantity is one standard 300 m or 500 m factory spool per colour/size (unlike heavy multicore silicone cables offered from 50 m cut lengths), with 7 to 45 working days lead time.

ASCII part references for BOM and ERP entry: TF-N2GFAF-STA-1X0.50; TF-N2GFAF-STA-1X0.75; TF-N2GFAF-STA-1X1.00; TF-N2GFAF-STA-1X1.50; TF-N2GFAF-STA-1X2.50; TF-N2GFAF-BC-1X0.75; TF-N2GFAF-BC-1X1.50; TF-N2GFAF-VDE0250.

Standards

N2GFAF DIN VDE 0250-502 & IEC Conductor Reference Standards

N2GFAF & (N)2GFAF Silicone Single-Core Wire (DIN VDE 0250-502, 300/300 V) standards and test references
Standard or specificationApplication
DIN VDE 0250-502 (Teil 502)Design reference for 300/300 V silicone-insulated single-core luminaire and equipment wires from 0.50 mm² to 2.50 mm².
IEC 60228 / EN 60228 Class 5Flexible bare, tinned or nickel-plated copper stranding and maximum linear DC resistance at 20 °C.
EN 50363-1 (Type EI2 Silicone Compound)Cross-linked silicone rubber insulation mechanical strength, thermal ageing at +200 °C and Shore hardness criteria.
IEC 60754-1, IEC 60754-2 & IEC 60332-1-2Halogen-free acid-gas emission verification and single-wire vertical flame retardance.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and DIN VDE 0250 conformity documentation

DIN VDE 0250-502 — Insulated power cables and wires: N2GFAF silicone rubber luminaire wires

IEC 60228 — Conductors of insulated cables (Class 5 flexible copper stranding)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.