N2GFAF & (N)2GFAF Silicone Single-Core Wire (DIN VDE 0250-502, 300/300 V)
N2GFAF and (N)2GFAF single-core silicone fixture wires (300/300 V, 2,000 V AC test) are constructed with reference to DIN VDE 0250-502 using IEC 60228 Class 5 tinned copper (-60 °C to +180 °C) or bare copper (-60 °C to +130 °C) conductors from 0.50 mm² to 2.50 mm² and Shore A 70 EI2 silicone rubber insulation.
N2GFAF and (N)2GFAF single-core silicone wires provide compact 300/300 V internal harness, lamp-holder and appliance wiring built with reference to DIN VDE 0250 Part 502 across five standardized cross-sections (0.50, 0.75, 1.00, 1.50 and 2.50 mm²), holding maximum outside diameter between 2.2 mm and 3.6 mm while passing 2,000 V AC dielectric testing.
European luminaire, commercial catering and domestic heating OEMs specify (N)2GFAF over general-purpose 300/500 V silicone wires because its regulated 0.6 mm to 0.8 mm EI2 silicone wall and 70 +/- 2 Shore A durometer feed reliably through high-speed automated cut-strip-crimp lines and narrow lamp suspension tubes without insulation bunching. Critically, DIN VDE 0250-502 differentiates conductor metallurgy: tinned copper strands operate continuously from -60 °C to +180 °C, whereas bare copper strands must be derated to +130 °C to prevent copper-catalysed thermal oxidation.
Specify (N)2GFAF when German or Italian OEM drawings call for DIN VDE 0250-502 300/300 V luminaire and appliance harness leads; select H03S-K for harmonized EN 50525-2-41 cords, or step up to 300/500 V SiF / H05SJ-K for higher voltage or cross-sections above 2.50 mm² (standard 300 m / 500 m factory spools rather than 50 m cut lengths, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
N2GFAF & (N)2GFAF VDE 0250-502 Silicone Wire Construction
TEBAOFLEX manufactures (N)2GFAF single-core wires to the dimensional, capillary stranding and Shore A hardness envelope of DIN VDE 0250-502 for automated European wire-harness production.

| Component | Material and construction |
|---|---|
| 1. Fine-Stranded Copper Conductor (IEC 60228 Class 5) | 0.21 mm max strand diameter on 0.50 to 1.00 mm² and 0.26 mm max strand diameter on 1.50 to 2.50 mm²: annealed tinned copper (-60 °C to +180 °C, N2GFAF-STA), plain bare copper (-60 °C to +130 °C), or optional nickel-plated copper. |
| 2. High-Durometer EI2 Silicone Rubber Insulation | Extruded cross-linked silicone rubber Type EI2 (70 +/- 2 Shore A hardness, 0.6 mm nominal wall on 0.50–1.00 mm², 0.7 mm on 1.50 mm² and 0.8 mm on 2.50 mm²), ozone-, UV- and thermal-shock resistant and halogen-free per IEC 60754-1. |
| 3. Harness Colour Coding | Available in white, black, red-brown, blue, brown, red, yellow, grey and green-yellow for multi-circuit appliance and lighting loom assembly. |
N2GFAF, (N)2GFAF & N2GFAF-STA Designation Breakdown
- (N) / N: Constructed with reference to German national DIN VDE 0250-502 dimensional and electrical rules
- 2G: Heat-resistant cross-linked silicone rubber core insulation compound Type EI2
- FA: Fassungsader — slim-wall luminaire, lamp-holder and internal equipment harness wire (300/300 V)
- F: Feindraehtig — flexible fine-stranded conductor per IEC 60228 Class 5 (0.50 to 2.50 mm²)
- -STA / -BC: Tinned copper conductor rated -60 to +180 °C (-STA) versus plain bare copper rated -60 to +130 °C (-BC)
N2GFAF Luminaire, Catering Oven & Appliance Harness Applications
Use N2GFAF / (N)2GFAF 300/300 V silicone wires in high-volume lighting fixtures, commercial baking equipment and electro-thermal appliance wire harnesses.

- Halogen, metal-halide, stage/studio and high-bay industrial luminaire internal leads, lamp holders and ballast compartments.
- Commercial convection ovens, espresso/coffee boilers, pizza deck ovens, toasters and catering warmers wired with automated crimp harnesses.
- Thermostats, cartridge heater tails, drying cabinets and HVAC electric duct-heater control looms operating up to +180 °C.
- Electronic power supplies, UV curing lamps and laboratory instruments requiring slim 2.2 to 3.6 mm OD halogen-free leads.
N2GFAF vs H03S-K vs SiF 300/500 V vs H05SJ-K Silicone Wire
| Wire Family | Rated Voltage & Standard | Size Range & Wall Profile | When to Specify |
|---|---|---|---|
| N2GFAF / (N)2GFAF (this page) | 300/300 V, DIN VDE 0250-502 reference | 0.50–2.50 mm², slim 0.6–0.8 mm Shore A 70 EI2 wall | Automated luminaire, lamp-holder & commercial appliance harnesses |
| H03S-K Silicone Wire | 300/300 V, EN 50525-2-41 harmonized | 0.50–2.50 mm², CENELEC HAR wall (2.1–3.6 mm OD) | Appliances requiring EN 50525-2-41 harmonized cordage code |
| SiF Silicone Single-Core | 300/500 V, DIN VDE 0250 reference | 0.25–150 mm², standard 300/500 V insulation wall | 500 V control cabinets, motors & power leads above 2.50 mm² |
| H05SJ-K / SiF/GL Braided Wire | 300/500 V, EN 50525-2-83 / VDE 0250 | 0.50–150 mm², EI2 silicone + varnished fiberglass braid | Sharp sheet-metal pass-throughs & high-abrasion oven terminals |
Select (N)2GFAF tinned copper (+180 °C) whenever European BOMs specify VDE 0250-502 slim-OD fixture wire for automated crimping.
N2GFAF & (N)2GFAF Silicone Harness Wire RFQ Checklist
- Conductor metallurgy: tinned copper N2GFAF-STA (-60 to +180 °C, recommended), bare copper (-60 to +130 °C) or nickel-plated copper (+200 °C).
- Cross-section (0.50, 0.75, 1.00, 1.50 or 2.50 mm²) and insulation colour breakdown.
- Maximum outside diameter window if feeding automatic Komax/Schleuniger crimp applicator guides or narrow lamp tubes.
- Packaging preference: 300 m / 500 m plastic spools, barrel packs or shrink-wrapped coils for automatic dereeling.
- Spool count per colour (MOQ 300 m or 500 m standard spool per colour/gauge) and required delivery date (7 to 45 working days).
Related selection resources
- High-temperature silicone, fluoropolymer and mica-glass wire catalog
- OEM high-temperature harness and appliance wire manufacturing
- H03S-K 300/300 V EN 50525-2-41 Silicone Single-Core Wire
- SiF 300/500 V 180 °C Flexible Silicone Single-Core Wire
- Engineering guide: Tinned copper vs bare copper conductor temperature limits
- High-temperature wire insulation temperature ratings comparison
N2GFAF & (N)2GFAF VDE 0250-502 Frequently Asked Questions
Why is bare-copper N2GFAF rated +130 °C while tinned-copper N2GFAF is rated +180 °C?
Above +130 °C in air, unprotected bare copper strands rapidly oxidize and form brittle cuprous oxide scales under oxygen-permeable silicone rubber, raising contact resistance; tin-plating the Class 5 strands (N2GFAF-STA) blocks copper oxidation up to +180 °C continuous (+200 °C short-time).
What does the (N) prefix in (N)2GFAF mean on German technical drawings?
In German DIN VDE notation, 2GFAF stands for silicone rubber insulation (2G), luminaire/fixture wire (FA) and fine-stranded Class 5 conductor (F), while placing (N) in parentheses indicates the wire is manufactured with reference to DIN VDE 0250-502 construction dimensions without claiming a VDE mark license.
Is N2GFAF suitable for automatic wire cutting, stripping and terminal crimping machines?
Yes. TEBAOFLEX formulates (N)2GFAF EI2 silicone insulation to a controlled 70 +/- 2 Shore A hardness with concentric 0.6 to 0.8 mm wall thickness so V-blades strip cleanly without gummy elongation or conductor strand nicking.
What is the minimum order quantity for N2GFAF / (N)2GFAF single-core wire?
Standard factory minimum order quantity is one 500 m spool per colour on 0.50, 0.75 and 1.00 mm² sizes and one 300 m or 500 m spool on 1.50 and 2.50 mm² sizes (rather than 50 m cut lengths used on heavy multicore cables), manufactured in 7 to 45 working days.
When should I upgrade from 300/300 V N2GFAF to 300/500 V SiF or H05SJ-K?
Step up from 300/300 V N2GFAF to 300/500 V SiF whenever the circuit phase-to-phase voltage exceeds 300 V or the conductor size exceeds 2.50 mm², and choose fiberglass-braided H05SJ-K if the wire passes through unbushed metal apertures.
N2GFAF & (N)2GFAF Dimensional, Resistance & Spool Schedule
N2GFAF Key Voltage, Shore Hardness, Temperature & Spool Summary
- DIN VDE 0250-502 geometry: Exact 0.6 mm to 0.8 mm EI2 silicone wall schedule keeping overall diameter slim (2.2 mm to 3.6 mm max) for luminaire stems and tight harnesses
- Conductor finish vs temperature: Tinned copper N2GFAF-STA / (N)2GFAF rated -60 °C to +180 °C; bare copper variant rated -60 °C to +130 °C; nickel-plated copper available to +200 °C
- High Shore A 70 tear resistance: 70 +/- 2 Shore A cross-linked EI2 silicone compound feeds smoothly through automatic wire-cutting, stripping and terminal-crimping machines
- 2,000 V AC dielectric safety: 300/300 V working rating verified by 2,000 V AC 50 Hz spark and dielectric testing despite compact luminaire-grade outside diameters
- Factory spool MOQ: Supplied on 500 m standard spools (0.50–1.00 mm²) or 300 m / 500 m spools (1.50–2.50 mm²) per colour in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 300/300 V AC (Uo/U) working voltage with 2000 V AC 50 Hz routine test voltage with reference to DIN VDE 0250-502 |
| Cross-section and strand geometry | 1x0.50, 1x0.75, 1x1.00, 1x1.50 and 1x2.50 mm2 IEC 60228 Class 5 flexible strands (0.21 mm or 0.26 mm capillary wire) |
| Conductor finish and temperature | -60 C to +180 C continuous with tinned copper conductor; -60 C to +130 C continuous with bare copper conductor |
| Insulation compound and hardness | Cross-linked silicone rubber Type EI2 (0.6 to 0.8 mm nominal wall, 70 plus or minus 2 Shore A) for automated stripping |
| Standard spool MOQ and lead time | 500 m standard spools (0.50 to 1.00 mm2) or 300 m / 500 m spools (1.50 to 2.50 mm2) per colour in 7 to 45 working days |
| Minimum bending radius | 5x outer diameter for fixed internal luminaire/appliance routing and 10x outer diameter during harness flexing |
| Halogen-free and ageing stability | Halogen-free per IEC 60754-1/2 with high resistance to UV, ozone, thermal shock and solder-iron pullback |
N2GFAF & (N)2GFAF Tinned (+180 °C) vs Bare (+130 °C) Copper Dimensional Schedule
| Model & Conductor Variant | Max Strand Ø (mm) | Conductor Ø (mm) | EI2 Wall (mm) | Nominal – Max OD (mm) | Max DC Res. at 20 °C (Ω/km) | Cu Index (kg/km) | Put-Up | Next step |
|---|---|---|---|---|---|---|---|
| N2GFAF 1x0.50 mm² Tinned Cu (+180 °C) | 0.21 | 0.90 | 0.6 | 2.10 – 2.20 | 40.1 | 4.8 | 500 m spool | Request this size |
| N2GFAF 1x0.75 mm² Tinned Cu (+180 °C) | 0.21 | 1.10 | 0.6 | 2.25 – 2.40 | 26.7 | 7.2 | 500 m spool | Request this size |
| N2GFAF 1x1.00 mm² Tinned Cu (+180 °C) | 0.21 | 1.20 | 0.6 | 2.40 – 2.50 | 20.0 | 9.6 | 500 m spool | Request this size |
| N2GFAF 1x1.50 mm² Tinned Cu (+180 °C) | 0.26 | 1.50 | 0.7 | 2.80 – 3.00 | 13.7 | 14.4 | 500 m / 300 m | Request this size |
| N2GFAF 1x2.50 mm² Tinned Cu (+180 °C) | 0.26 | 1.90 | 0.8 | 3.40 – 3.60 | 8.21 | 24.0 | 300 m / 500 m | Request this size |
| N2GFAF-BC 1x0.50 mm² Bare Cu (+130 °C) | 0.21 | 0.90 | 0.6 | 2.10 – 2.20 | 39.0 | 4.8 | 500 m spool | Request this size |
| N2GFAF-BC 1x0.75 mm² Bare Cu (+130 °C) | 0.21 | 1.10 | 0.6 | 2.25 – 2.40 | 26.0 | 7.2 | 500 m spool | Request this size |
| N2GFAF-BC 1x1.00 mm² Bare Cu (+130 °C) | 0.21 | 1.20 | 0.6 | 2.40 – 2.50 | 19.5 | 9.6 | 500 m spool | Request this size |
| N2GFAF-BC 1x1.50 mm² Bare Cu (+130 °C) | 0.26 | 1.50 | 0.7 | 2.80 – 3.00 | 13.3 | 14.4 | 500 m / 300 m | Request this size |
| N2GFAF-BC 1x2.50 mm² Bare Cu (+130 °C) | 0.26 | 1.90 | 0.8 | 3.40 – 3.60 | 7.98 | 24.0 | 300 m / 500 m | Request this size |
In German cable nomenclature, the bracketed prefix (N)2GFAF denotes construction and dimensional geometry built with reference to DIN VDE 0250-502 (rather than a VDE mark license); final conductor stranding, OD tolerance and Shore hardness are confirmed on the quotation drawing.
Always specify tinned copper (N2GFAF-STA / tinned (N)2GFAF) when continuous conductor temperature exceeds +130 °C up to +180 °C; bare copper is intended for +130 °C max welding/brazing or specialized weld-tab terminations.
Because 0.50 to 2.50 mm² luminaire hook-up wires run on continuous high-speed extrusion lines, minimum order quantity is one standard 300 m or 500 m factory spool per colour/size (unlike heavy multicore silicone cables offered from 50 m cut lengths), with 7 to 45 working days lead time.
ASCII part references for BOM and ERP entry: TF-N2GFAF-STA-1X0.50; TF-N2GFAF-STA-1X0.75; TF-N2GFAF-STA-1X1.00; TF-N2GFAF-STA-1X1.50; TF-N2GFAF-STA-1X2.50; TF-N2GFAF-BC-1X0.75; TF-N2GFAF-BC-1X1.50; TF-N2GFAF-VDE0250.
N2GFAF DIN VDE 0250-502 & IEC Conductor Reference Standards
| Standard or specification | Application |
|---|---|
| DIN VDE 0250-502 (Teil 502) | Design reference for 300/300 V silicone-insulated single-core luminaire and equipment wires from 0.50 mm² to 2.50 mm². |
| IEC 60228 / EN 60228 Class 5 | Flexible bare, tinned or nickel-plated copper stranding and maximum linear DC resistance at 20 °C. |
| EN 50363-1 (Type EI2 Silicone Compound) | Cross-linked silicone rubber insulation mechanical strength, thermal ageing at +200 °C and Shore hardness criteria. |
| IEC 60754-1, IEC 60754-2 & IEC 60332-1-2 | Halogen-free acid-gas emission verification and single-wire vertical flame retardance. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and DIN VDE 0250 conformity documentation
DIN VDE 0250-502 — Insulated power cables and wires: N2GFAF silicone rubber luminaire wires
IEC 60228 — Conductors of insulated cables (Class 5 flexible copper stranding)
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
H03S-K Single Core Silicone Rubber High Temperature Cable
A related cable option for a different application or duty profile.
View productSiF Single-Core Flexible Silicone Wire & Power Lead (300/500 V, 180 °C)
A related cable option for a different application or duty profile.
View productHigh Temperature Silicone Rubber SIA / SIAF Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.