GN500 & GN500-01 500 V Metric Mica-Tape & Fiberglass Braided High-Temperature Wire (350–500 °C)
GN500 and GN500-01 (TF-GN500-MICA-WIRE) are 500 V metric mica-tape and woven fiberglass braided high-temperature fire-resistant lead wires spanning 0.5 mm² to 50 mm². Supplied in +350 °C bare/tinned copper (GN500-01) and +500 °C continuous 27 % nickel-clad or pure nickel builds (GN500-Ni27 / GN500-Ni) for industrial furnaces, band heaters and steelworks.
GN500 and GN500-01 500 V metric mica-tape and fiberglass-braided fire-resistant wires supply single-core heating-element, thermocouple-head and burner-igniter connections from 0.5 mm² up to 50 mm² where ambient temperatures exceed the +180 °C ceiling of SiF silicone wire and the +260 °C ceiling of PTFE/PFA fluoropolymer wire.
Many supplier datasheets market bare-copper GN500-01 as a 500 °C wire while burying a +350 °C limit in fine print—because bare copper oxidizes rapidly and sheds conductive scale above +300 to +350 °C even though phlogopite mica withstands +800 °C. TEBAOFLEX separates both grades explicitly: economical GN500-01 uses bare or tinned Class 5 copper for -60 °C to +350 °C drying ovens and platen heaters, whereas GN500-Ni27 uses ASTM B355 Class 27 (27 % by weight) nickel-clad copper (or pure Ni99 on GN500-Ni) to deliver genuine +500 °C continuous (+550 °C peak) service without conductor embrittlement.
Specify metric GN500-Ni27 or GN500-01 when equipment drawings call out DIN / IEC metric terminals (0.5–50 mm²) or Chinese/export codes GN500, GN500-01, YGZP or AGRP; specify North American MGT / UL 5107 / UL 5400 when BOMs require 24 AWG to 4/0 AWG 600 V UL-style gauges. MOQ 300 m per size/colour on 0.5–4.0 mm² and 50 m on 6.0–50 mm², shipped in 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
GN500 & GN500-01 Metric Mica-Glass Wire Construction
Constructed with concentric metric Class 5 conductors, 50 %+ overlapped phlogopite/synthetic mica barrier tapes and resin-locked alkali-free E-glass braiding.

| Component | Material and construction |
|---|---|
| 1. Metric Stranded Conductor (Bare Cu, 27 % Nickel-Clad Cu or Pure Ni) | Fine-stranded bare copper on GN500-01 (up to +350 °C), 27 % nickel-clad copper CuNi27 on GN500-Ni27 (up to +500 °C continuous), or pure nickel Ni99 on GN500-Ni (up to +600 °C). |
| 2. Multi-Turn Helical Phlogopite / Synthetic Mica Tape Insulation | Two or more overlapped calcination-stable mica tapes forming a 500 V AC (2,000 V AC test) dielectric barrier that will not melt, drip or carbonize. |
| 3. Woven Alkali-Free E-Glass Reinforcing Braid | Tightly braided fiberglass jacket providing mechanical abrasion, cut-through and tight-bend support (minimum fixed bend radius 6× OD). |
| 4. High-Temperature Silicone or PTFE Dispersion Finish | Cured inorganic-silicone or PTFE emulsion coating in white (with colour tracers) or solid colours (red, blue, black, brown, yellow) preventing glass fray. |
GN500, GN500-01 & GN500-Ni27 Grade Breakdown
- GN: High-temperature inorganic mica-tape & woven fiberglass insulated equipment lead wire
- 500: 500 V AC rated voltage class (and +500 °C continuous rating when paired with CuNi27)
- -01 (GN500-01): Bare annealed copper conductor economical grade rated -60 °C to +350 °C continuous
- -Ni27 (GN500-Ni27): 27 % concentric nickel-clad copper conductor (ASTM B355 Class 27) rated +500 °C continuous
- -Ni (GN500-Ni): Pure nickel Ni99 stranded conductor grade for extreme +550 °C to +600 °C heater terminals
GN500 Industrial Heaters, Annealing Furnaces & Kiln Duty
Built for fixed internal and furnace-adjacent high-temperature wiring in metallurgy, plastics machinery, glass, ceramics and industrial heating.

- Extruder barrel ceramic band heaters, injection-moulding hot-runner manifolds, cartridge heaters and die-head heating rings.
- Electric annealing, tempering, carburizing and vacuum heat-treatment furnace terminal boxes and heating-element bus jumpers.
- Steelworks ladle preheaters, EAF / BOF lance junction boxes, glass-melting forehearth heaters and ceramic tunnel-kiln igniters.
- Foundry core-baking ovens, power-plant air-preheater dampers, industrial catering ovens and high-intensity discharge lamp housings.
GN500 (Metric mm²) vs MGT (AWG) vs TGGT vs VDE 5Y PTFE
| Lead Wire Family | Sizing & Voltage | Continuous Temp & Insulation | When to Specify |
|---|---|---|---|
| GN500-Ni27 & GN500-01 (this page) | Metric 0.5–50 mm²; 500 V | +350 °C (bare Cu) / +500 °C (CuNi27); mica tape + E-glass braid | Metric DIN/IEC heater & furnace BOMs from +300 °C to +500 °C |
| MGT / UL 5107 / UL 5400 | 24 AWG–4/0 AWG; 300/600 V | +450 °C / +538–550 °C; CuNi27 + mica-glass + glass braid | North American AWG-sized kilns, steel mills & UL-style OEM harnesses |
| TGGT / UL 5256 / UL 5196 | 24 AWG–4/0 AWG; 300/600 V | +250 °C; 2% NPC + sintered PTFE tape + glass braid | Moist commercial ovens & chemical heaters up to +250 °C requiring moisture seal |
| VDE 5Y PTFE / UL 11486 | Metric 0.14–16 mm²; 500/1000 V | -190 to +260 °C; solid extruded virgin PTFE | Wet chemical immersion or tight-cabinet metric wiring up to +260 °C |
Mica-glass braided wires (GN500 and MGT) breath in high humidity and are not designed for liquid immersion; below +250/+260 °C in wet washdown zones, specify TGGT or extruded PFA/PTFE wire.
GN500 & GN500-01 Mica-Glass Lead Wire RFQ Checklist
- Grade selection: GN500-01 (+350 °C bare copper), GN500-Ni27 (+500 °C 27 % nickel-clad copper) or GN500-Ni (+600 °C pure nickel).
- Metric cross-section (0.5 mm² to 50 mm²) and outer braid finish (silicone resin PFAS-free vs PTFE emulsion).
- Outer braid colour (natural white with tracer, or solid red, blue, black, brown, yellow).
- Order quantity per size/colour (MOQ 300 m coil on 0.5–4.0 mm², 50 m reel on 6.0–50 mm²; 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Mica, Silicone & Fluoropolymer Wires
- Compare MGT (UL 5107 / UL 5128) 24 AWG–4/0 AWG 450/538 °C Mica-Glass Wire
- Compare Multi-Core 450 °C 600 V Mica-Glass High-Temperature Cable
- Compare TGGT (UL 5256 / UL 5196) 250 °C Moisture-Sealed PTFE-Glass Wire
- Compare VDE 5Y PTFE (260 °C) Metric Extruded Single-Core Wire
- Engineering guide: Why copper plating limits high-temperature wire ratings
GN500 & GN500-01 Mica-Fiberglass High-Temp Wire FAQ
Why is GN500-01 rated +350 °C while GN500-Ni27 reaches +500 °C continuous?
The conductor sets the ceiling: phlogopite mica and E-glass withstand over +550 °C, but bare copper in GN500-01 oxidizes and flakes above +300 to +350 °C; upgrading to 27 % nickel-clad copper (GN500-Ni27) blocks oxygen diffusion up to +500 °C continuous.
What is the difference between metric GN500 wire and North American MGT wire?
Both use mica-tape insulation under a treated fiberglass braid, but GN500 is built to IEC metric cross-sections (0.5 mm² to 50 mm², 500 V) matching metric DIN crimp lugs, whereas MGT is built to UL 5107 / 5128 AWG gauges (24 AWG to 4/0 AWG, 300/600 V).
Can GN500-Ni27 or GN500-01 be terminated with standard tin solder?
No — tin-lead and lead-free solders melt between +183 °C and +227 °C, and 27 % nickel cladding resists rosin wetting; always terminate GN500 leads using high-temperature nickel-plated or stainless crimp lugs or spot welding.
Is GN500 mica-fiberglass wire waterproof for outdoor immersion or steam washdown?
No — lapped mica tape and woven fiberglass resist ambient furnace moisture via silicone/PTFE impregnation, but they are not hermetically waterproof; for wet washdown up to +260 °C, specify extruded PFA or VDE 5Y PTFE wire.
What is the minimum order quantity and lead time for GN500 and GN500-01?
300 m standard coils on 0.5 mm² through 4.0 mm² sizes and 50 m reels on 6.0 mm² through 50 mm² sizes, manufactured in 7 to 45 working days.
GN500-Ni27 (+500 °C) & GN500-01 (+350 °C) Metric Schedule
GN500 500 V Voltage, Conductor Metallurgy & Spool Summary
- True metric 0.5–50 mm² sizing: Purpose-built IEC 60228 Class 5 metric cross-sections (0.5 to 50 mm²) for European, CIS, Middle East and Asian furnace BOMs where AWG MGT wire mismatches lugs
- Transparent +350 °C vs +500 °C metallurgy: GN500-01 bare copper serves -60 to +350 °C heating zones economically; GN500-Ni27 (27 % nickel-clad copper) prevents copper scaling up to +500 °C continuous
- Multi-layer phlogopite / synthetic mica: Helically lapped high-dielectric mica tapes bonded beneath a silicone- or PTFE-impregnated E-glass outer braid maintain 500 V insulation under direct flame
- Non-fraying clean-strip finish: High-temperature cured silicone/PTFE resin dispersion locks the fiberglass weave against pushback during high-speed cutting and nickel-lug crimping
- 300 m coils & 50 m heavy reels: Supplied in 300 m standard coils/spools on 0.5–4.0 mm² lead sizes and 50 m reels on 6.0–50 mm² heavy bus leads in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 500 V AC nominal with 2000 V AC 1-minute routine dielectric withstand and spark test |
| Metric cross-section range | 0.5, 0.75, 1.0, 1.5, 2.5, 4.0, 6.0, 10, 16, 25, 35 and 50 mm2 fine-stranded conductors |
| Thermal and conductor grades | GN500-01 (-60 C to +350 C, bare copper), GN500-Ni27 (-60 C to +500 C continuous, 27% nickel-clad copper) and GN500-Ni (up to +600 C, pure nickel) |
| Minimum bend radius | 6x outer diameter for fixed furnace and heater harness installation (8x OD on 16 to 50 mm2 heavy leads) |
| Standard put-up and lead time | 300 m minimum order coils on 0.5 to 4.0 mm2 and 50 m reels on 6.0 to 50 mm2; 7 to 45 working days lead time |
| Fire and smoke behaviour | Non-melting inorganic mica-glass barrier maintains circuit insulation during direct flame exposure; PFAS-free silicone-finish option available |
| Termination method | High-temperature nickel or stainless-steel crimp ring/spade lugs or resistance spot-welding (ordinary tin-lead solder melts above +183 C) |
GN500-Ni27 (+500 °C Continuous, 27 % Nickel-Clad Copper) Metric Schedule
| Model & Cross-Section | CuNi27 Stranding (No. × Ø mm) | Conductor Ø (mm) | Nom. OD (mm) | Max. R at 20 °C (Ω/km) | Ref. Current at +400 °C Air (A) | Approx. Weight (kg/km) | Standard MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| GN500-Ni27 0.5 mm² | 16 × 0.20 | 0.95 | 2.3 | 52.8 | 4.5 | 10.5 | 300 m coil | Request this size |
| GN500-Ni27 0.75 mm² | 24 × 0.20 | 1.15 | 2.5 | 35.2 | 6.0 | 13.8 | 300 m coil | Request this size |
| GN500-Ni27 1.0 mm² | 32 × 0.20 | 1.32 | 2.7 | 26.4 | 7.5 | 17.2 | 300 m coil | Request this size |
| GN500-Ni27 1.5 mm² | 30 × 0.25 | 1.60 | 3.1 | 17.9 | 10.0 | 23.5 | 300 m coil | Request this size |
| GN500-Ni27 2.5 mm² | 49 × 0.25 | 2.05 | 3.6 | 10.8 | 14.5 | 35.0 | 300 m coil | Request this size |
| GN500-Ni27 4.0 mm² | 56 × 0.30 | 2.60 | 4.3 | 6.75 | 20.0 | 52.5 | 300 m coil | Request this size |
| GN500-Ni27 6.0 mm² | 84 × 0.30 | 3.20 | 5.0 | 4.50 | 26.5 | 75.0 | 50 m reel | Request this size |
| GN500-Ni27 10 mm² | 80 × 0.40 | 4.25 | 6.4 | 2.62 | 38.0 | 124.0 | 50 m reel | Request this size |
| GN500-Ni27 16 mm² | 126 × 0.40 | 5.35 | 7.8 | 1.65 | 52.0 | 190.0 | 50 m reel | Request this size |
| GN500-Ni27 25 mm² | 196 × 0.40 | 6.70 | 9.5 | 1.06 | 70.0 | 292.0 | 50 m reel | Request this size |
| GN500-Ni27 35 mm² | 276 × 0.40 | 7.95 | 11.0 | 0.755 | 88.0 | 402.0 | 50 m reel | Request this size |
| GN500-Ni27 50 mm² | 396 × 0.40 | 9.60 | 13.0 | 0.528 | 112.0 | 568.0 | 50 m reel | Request this size |
GN500-01 (+350 °C Bare Copper) Metric Mica Wire Schedule
| Model & Cross-Section | Bare Cu Stranding (No. × Ø mm) | Nom. OD (mm) | Max. R at 20 °C (Ω/km) | Ref. Current at +250 °C Air (A) | Approx. Weight (kg/km) | Standard MOQ | Next step |
|---|---|---|---|---|---|---|---|
| GN500-01 0.75 mm² | 24 × 0.20 | 2.5 | 26.0 | 8.5 | 13.5 | 300 m coil | Request this size |
| GN500-01 1.0 mm² | 32 × 0.20 | 2.7 | 19.5 | 10.5 | 16.8 | 300 m coil | Request this size |
| GN500-01 1.5 mm² | 30 × 0.25 | 3.1 | 13.3 | 14.0 | 23.0 | 300 m coil | Request this size |
| GN500-01 2.5 mm² | 49 × 0.25 | 3.6 | 7.98 | 19.5 | 34.2 | 300 m coil | Request this size |
| GN500-01 4.0 mm² | 56 × 0.30 | 4.3 | 4.95 | 26.0 | 51.5 | 300 m coil | Request this size |
| GN500-01 6.0 mm² | 84 × 0.30 | 5.0 | 3.30 | 34.0 | 73.8 | 50 m reel | Request this size |
| GN500-01 10 mm² | 80 × 0.40 | 6.4 | 1.91 | 48.0 | 122.0 | 50 m reel | Request this size |
| GN500-01 16 mm² | 126 × 0.40 | 7.8 | 1.21 | 66.0 | 187.0 | 50 m reel | Request this size |
| GN500-01 25 mm² | 196 × 0.40 | 9.5 | 0.780 | 88.0 | 288.0 | 50 m reel | Request this size |
| GN500-01 35 mm² | 276 × 0.40 | 11.0 | 0.554 | 110.0 | 396.0 | 50 m reel | Request this size |
Note on DC resistance: 27 % nickel-clad copper (ASTM B355 Class 27) has approximately 72 % IACS conductivity compared with 100 % IACS bare copper, yielding slightly higher 20 °C resistance while preventing destructive oxide scaling between +350 °C and +500 °C. Final values are confirmed on the quotation drawing.
ASCII part references for BOM and ERP entry: TF-GN500-NI27-1.5, TF-GN500-NI27-2.5, TF-GN500-NI27-4.0, TF-GN500-NI27-6.0, TF-GN500-NI27-10, TF-GN500-NI27-16, TF-GN500-01-1.5, TF-GN500-01-2.5, TF-GN500-01-4.0, TF-GN500-01-6.0.
GN500 Reference Standards (IEC 60228, ASTM B355 & Fire Integrity)
| Standard or specification | Application |
|---|---|
| IEC 60228 & ASTM B355 Class 27 Reference | Metric flexible copper stranding geometry and 27 % concentric nickel cladding thickness for +500 °C oxidation immunity. |
| IEC 60331 & IEC 60332-1-2 Fire-Integrity Principles | Calcination-resistant mica-tape dielectric barrier and vertical flame propagation self-extinguishing performance. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and 2,000 V AC spark/dielectric verification
ASTM B355 — Standard Specification for Nickel-Coated Soft or Annealed Copper Wire
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
MGT Wire & Cable — UL 5107, UL 5128, UL 5390 & UL 5400 Mica-Glass Lead Wire (450 °C / 550 °C)
A related cable option for a different application or duty profile.
View productMulticore Mica-Glass High-Temperature Cable, 450°C 600 V
A related cable option for a different application or duty profile.
View productTGGT Wire — UL 5256, UL 5196 & UL 5257 PTFE-Glass Lead Wire (250 °C, 300/600 V)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.