High Temperature Cables TEBAOFLEX

VDE 5Y PTFE (260 °C, UL 11486) & VDE 6Y / 6YI1 FEP (205 °C) Metric Single-Core Wire

VDE 5Y PTFE (-190 °C to +260 °C, dual-referenced to UL 11486) and VDE 6Y / 6YI1 FEP (-100 °C to +205 °C) metric single-core wires (300/500 V, 600 V and 1,000 V) pair fine-stranded Class 5 tinned, silver-plated or nickel-plated copper conductors (0.14 to 16 mm²) with DIN VDE 0207-6 fluoropolymer insulation.

Product information
SKU
TF-VDE-5Y-PTFE-6Y-FEP
Brand
TEBAOFLEX
Product overview

VDE 5Y PTFE and VDE 6Y / 6YI1 FEP metric single-core high-temperature wires provide European-standard chemical, cryogenic and thermal protection from 0.14 mm² up to 16 mm², covering -190 °C to +260 °C continuous service (+300 °C short-term) on sintered 5Y PTFE and -100 °C to +205 °C continuous service (+230 °C short-term) on melt-extruded 6Y / 6YI1 FEP.

European furnace builders, plastics extruder OEMs, automotive paint-shop engineers and chemical analyser manufacturers routinely specify metric DIN VDE 0207-6 codes (5Y for PTFE, 6Y / 6YI1 for FEP) or dual-rated UL Style 11486 where silicone single-core wires (SiF) cannot be used due to hot acid/solvent attack or strict LABS/PWIS silicone-free paint-line rules. Both insulation compounds achieve > 1–2 GOhm*km insulation resistance, < 0.01 % water absorption and non-flammable self-extinguishing performance per IEC 60332-1-2.

Select VDE 5Y PTFE with nickel-plated copper for +250 °C to +260 °C continuous duty (or silver-plated copper up to +200 °C and high-frequency skin-effect wiring), or choose VDE 6Y / 6YI1 FEP with Class 5 tinned or silver-plated copper when 100 % continuous splice-free spools up to +205 °C are required (MOQ 300 m / 500 m spools, 7 to 45 working days).

Explore the high-temperature wire and cable range for related configurations.

Construction

VDE 5Y PTFE & VDE 6Y / 6YI1 FEP Wire Construction

Manufactured in strict accordance with DIN VDE 0207-6, DIN VDE 0881 and IEC 60228 Class 5, matching conductor plating directly to the continuous thermal ceiling.

Clean 2D engineering cross-section of VDE 5Y PTFE and VDE 6Y FEP single-core wire showing concentric fluoropolymer insulation around fine-stranded Class 5 copper
VDE 5Y / 6Y cross-section: thin concentric DIN VDE 0207-6 fluoropolymer wall and fine-stranded copper core.
VDE 5Y PTFE (260 °C, UL 11486) & VDE 6Y / 6YI1 FEP (205 °C) Metric Single-Core Wire construction
ComponentMaterial and construction
1. Fine-Stranded Plated Copper Conductor (Class 5 / AWG-Stranded)Tinned copper (CuSn, up to +180 °C) or silver-plated copper (CuAg, up to +200/+205 °C) on VDE 6Y / 6YI1 FEP; silver-plated copper (+200 °C, UL 11486) or nickel-plated copper (CuNi, +260 °C) on VDE 5Y PTFE.
2. DIN VDE 0207-6 Fluoropolymer Core Insulation (5Y or 6Y / 6YI1)Paste-extruded and sintered polytetrafluoroethylene Type 5Y (-190 °C to +260 °C) or melt-extruded stress-crack-resistant fluorinated ethylene propylene Type 6Y / 6YI1 (-100 °C to +205 °C).
3. VDE Standard Core ColoursBlack, red, blue, brown, white, natural translucent, grey, violet, yellow, orange, pink and green-yellow protective earth.

VDE 5Y, 6Y, 6YI1 & UL 11486 Designation Breakdown

  • 5Y: DIN VDE 0207-6 polytetrafluoroethylene (PTFE) fluoropolymer insulation (-190 °C to +260 °C)
  • 6Y / 6YI1: DIN VDE 0207-6 stress-crack-resistant fluorinated ethylene propylene (FEP, -100 °C to +205 °C)
  • Type E / EE: 600 V AC (3.4 kV test) and 1,000 V AC (5.0 kV test) PTFE wall thickness classes per VDE 0881
  • UL 11486: Dual-referenced 300/500 V thin-wall PTFE single-core geometry across 28–12 AWG (0.09–4.0 mm²)
  • CuSn / CuAg / CuNi: Tinned (+180 °C), silver-plated (+200 °C) or nickel-plated (+260 °C) Class 5 copper conductors
Applications

VDE 5Y & 6Y Paint-Shop, Chemical, Kiln & Cryogenic Duties

Designed for silicone-free high-temperature cabinets, chemical vapour zones, cryogenic apparatus and industrial heating elements.

Industrial plastics extruder heater bands and PWIS-free curing oven terminal box wired with VDE 5Y PTFE and VDE 6Y FEP fluoropolymer single-core leads
Plastics extruder barrel heaters and silicone-free curing cabinet wired with metric VDE 5Y and 6Y leads.
  • Automotive cathodic dip-coating and paint-curing ovens where PWIS / LABS rules strictly prohibit outgassing silicone cables.
  • Plastics injection-moulder nozzle heater bands, hot-runner manifolds, ceramic kilns, brickworks and commercial catering ovens.
  • Electroplating baths, acid pickling switchgear, pharmaceutical autoclaves and chemical dosing cabinets exposed to solvents and halogens.
  • Cryogenic liquid-nitrogen (-190 °C) sensor leads and high-frequency instrumentation requiring ultra-low dielectric loss (tan delta < 0.0003).

VDE 5Y PTFE vs VDE 6Y FEP vs SiF Silicone vs PFA

VDE 5Y PTFE (260 °C) vs VDE 6Y / 6YI1 FEP (205 °C) vs SiF Silicone (180 °C) vs N2GFAF (180 °C)
Metric Wire TypeThermal RangeChemical & LABS/PWIS ProfilePut-Up Continuity & Best Use
VDE 5Y PTFE / UL 11486 (this page)-190 °C to +260 °C (+300 °C peak)Immune to all acids/solvents; 100 % LABS/silicone-freePaste-extruded sintered PTFE for 260 °C kilns, cryogenics & soldering zones
VDE 6Y / 6YI1 FEP (this page)-100 °C to +205 °C (+230 °C peak)Acid/alkali/oil immune; 100 % LABS/silicone-freeMelt-extruded 100 % splice-free 300–500 m spools for paint shops & cabinets
SiF Silicone Single-Core (ID 1447)-60 °C to +180 °CHalogen-free elastomer; swells in hot aromatics/acids; contains siliconeSoft, economical cabinet & luminaire hook-up in dry ventilated air
PFA Single-Core (ID 3772)-80 °C to +250 / +260 °CMatches PTFE chemical/260 °C rating with melt-extruded continuitySpecify when 260 °C rating AND zero-splice 500 m+ spools are both required

Always match conductor plating (CuSn +180 °C, CuAg +200 °C, CuNi +260 °C) to the maximum operating temperature.

VDE 5Y PTFE & VDE 6Y FEP Metric Wire RFQ Checklist

  • Insulation code and voltage class: VDE 5Y PTFE (300/500 V UL 11486, 600 V Type E or 1,000 V Type EE) or VDE 6Y / 6YI1 FEP (300/500 V or 600 V).
  • Metric conductor cross-section (0.14 mm² to 16 mm²) and plating (tinned CuSn, silver-plated CuAg, or nickel-plated CuNi for +260 °C).
  • Whether 100 % single-piece splice-free spool continuity is mandatory (select 6Y FEP up to +205 °C or melt-extruded PFA up to +260 °C).
  • Insulation colour (BK, RD, BU, BN, WH, TR, GN-YE) and total spool quantity (MOQ 300 m / 500 m per colour, 7 to 45 working days).

Related selection resources

VDE 5Y PTFE & VDE 6Y / 6YI1 FEP Frequently Asked Questions

What do VDE 5Y and VDE 6Y / 6YI1 mean in German fluoropolymer cable codes?

2 fluoropolymer insulation families defined in DIN VDE 0207-6: 5Y designates polytetrafluoroethylene (PTFE, -190 °C to +260 °C), while 6Y and 6YI1 designate stress-crack-resistant fluorinated ethylene propylene (FEP, -100 °C to +205 °C).

Which conductor plating should I specify on VDE 5Y PTFE wire for +260 °C continuous operation?

Nickel-plated copper (CuNi) is mandatory for continuous +250 °C to +260 °C operation; silver-plated copper (CuAg) is rated up to +200 °C continuous, and tinned copper (CuSn) is rated up to +180 °C.

Why are VDE 5Y PTFE and VDE 6Y FEP wires mandatory in automotive paint-curing lines?

0 % silicone content makes VDE 5Y PTFE and VDE 6Y FEP completely free of paint-wetting impairment substances (LABS / PWIS-free), eliminating crater defects caused by outgassing silicone wires.

What is the difference between VDE 5Y PTFE and VDE 6Y FEP spool continuity?

300 m to 500 m VDE 6Y FEP spools are melt-extruded in 100 % continuous single lengths, whereas sintered VDE 5Y PTFE is ram/paste-extruded from billets and may contain spark-tested factory lengths per VDE 0881 unless melt-extruded PFA is specified.

What is the minimum order quantity and lead time for VDE 5Y and VDE 6Y single-core wire?

300 m or 500 m standard factory spools per cross-section and colour, manufactured in 7 to 45 working days depending on conductor plating.

Specifications

VDE 5Y PTFE & VDE 6Y / 6YI1 FEP Metric Schedules (0.14–16 mm²)

VDE 5Y & 6Y Voltage, Temperature, Plating & Spool Summary

  • European metric mm² schedules: True metric 0.14 to 16 mm² cross-sections per DIN VDE 0207-6, DIN VDE 0881 and IEC 60228 Class 5 for European machinery & furnace drawings
  • VDE 5Y PTFE (-190 to +260 °C): Non-melting sintered PTFE wall in 300/500 V (UL 11486), 600 V Type E (3.4 kV test) and 1,000 V Type EE (5.0 kV test) up to +300 °C peak
  • VDE 6Y / 6YI1 FEP (-100 to +205 °C): Continuous melt-extruded stress-crack-resistant FEP wall in 300/500 V and 600 V (2.5 kV test) for long splice-free cabinet harnesses
  • Silicone-free & PWIS/LABS clean: 100 % free of silicone and lacquer-wetting-impairment substances for automotive paint-drying ovens, chemical plants and cleanrooms
  • Standard factory spool supply: Delivered on 300 m or 500 m factory spools per colour (MOQ 300 m) with a 7 to 45 working days manufacturing lead time
VDE 5Y PTFE (260 °C, UL 11486) & VDE 6Y / 6YI1 FEP (205 °C) Metric Single-Core Wire technical data
ParameterValue
Rated voltage300/500 V (VDE 6YI1 and UL 11486), 600 V (VDE 6Y and VDE 5Y Type E, 2.5 to 3.4 kV test) and 1000 V (VDE 5Y Type EE, 5.0 kV AC test)
Metric cross-section range0.14 mm2 to 16 mm2 (approx. 26 AWG to 6 AWG) in fine-stranded Class 5 tinned, silver-plated or nickel-plated copper
Fluoropolymer insulation gradesDIN VDE 0207-6 Type 5Y sintered PTFE (-190 C to +260 C) and Type 6Y / 6YI1 melt-extruded FEP (-100 C to +205 C), 100% silicone-free
Bending radius and insulation resistance4x OD fixed installation and 10x OD occasional flexing, with at least 1 GOhm*km (5Y PTFE) to 2 GOhm*km (6Y FEP) insulation resistance
Standard put-up and lead time300 m or 500 m standard factory spools per colour (MOQ 300 m) manufactured in 7 to 45 working days
Standards compliance noteEngineered to DIN VDE 0207-6, DIN VDE 0881, IEC 60673 and UL 758 Style 11486 specifications (third-party VDE or UL mark is not claimed)
Chemical and moisture immunityLess than 0.01% water absorption and complete resistance to concentrated acids, alkalis, fuels, hydraulic fluids, ozone and UV

VDE 5Y PTFE (-190 to +260 °C, 600/1000 V & UL 11486) Metric Schedule

VDE 5Y PTFE Single-Core Wire (-190 °C to +260 °C, 600 V Type E / 1000 V Type EE & UL 11486 300/500 V) — Metric Dimensional Schedule
Model & Cross-SectionEquiv. AWG / Strands600 V / UL 11486 OD (mm)1000 V Type EE OD (mm)Copper Index (kg/km)Approx. Weight 600V / 1000V (kg/km)Standard Spool MOQNext step
VDE 5Y PTFE 1x0.14 mm²26 AWG (7 or 19w)0.991.241.42.1 / 2.8300 m / 500 mRequest this size
VDE 5Y PTFE 1x0.25 mm²24 AWG (19w)1.121.372.43.2 / 4.1300 m / 500 mRequest this size
VDE 5Y PTFE 1x0.38 mm²22 AWG (19w)1.271.523.64.6 / 5.7300 m / 500 mRequest this size
VDE 5Y PTFE 1x0.50 mm²20 AWG (19w)1.471.725.66.8 / 8.1300 m / 500 mRequest this size
VDE 5Y PTFE 1x0.75 mm²19 AWG (19w)1.651.907.29.1 / 10.6300 m / 500 mRequest this size
VDE 5Y PTFE 1x1.0 mm²18 AWG (19w)1.742.009.611.5 / 13.7300 m / 500 mRequest this size
VDE 5Y PTFE 1x1.5 mm²16 AWG (19w)2.042.2614.417.2 / 21.4300 m / 500 mRequest this size
VDE 5Y PTFE 1x2.5 mm²14 AWG (19w)2.402.7624.027.8 / 34.0300 m spoolRequest this size
VDE 5Y PTFE 1x4.0 mm²12 AWG (37w)3.103.5038.044.5 / 51.0300 m spoolRequest this size
VDE 5Y PTFE 1x6.0 mm²10 AWG (37w)4.204.6558.068.0 / 76.5300 m spoolRequest this size
VDE 5Y PTFE 1x10 mm²8 AWG (133w)5.305.8096.0116.0 / 128.0300 m spoolRequest this size
VDE 5Y PTFE 1x16 mm²6 AWG (133w)7.808.30154.0178.0 / 194.0300 m spoolRequest this size

VDE 6Y & 6YI1 FEP (-100 to +205 °C, 300/500 V & 600 V) Metric Schedule

VDE 6Y & 6YI1 FEP Single-Core Wire (-100 °C to +205 °C, 300/500 V & 600 V) — Metric Dimensional, Copper & Weight Schedule
Model & Cross-SectionConductor ClassNom. Outer Ø (mm)Copper Index (kg/km)Approx. Weight (kg/km)Continuous Temp. (TPC / SPC)Standard Spool MOQNext step
VDE 6Y / 6YI1 FEP 1x0.14 mm²IEC 60228 Cl. 51.001.352.6+180 °C / +205 °C300 m / 500 mRequest this size
VDE 6Y / 6YI1 FEP 1x0.25 mm²IEC 60228 Cl. 51.162.404.1+180 °C / +205 °C300 m / 500 mRequest this size
VDE 6Y / 6YI1 FEP 1x0.50 mm²IEC 60228 Cl. 51.424.808.0+180 °C / +205 °C300 m / 500 mRequest this size
VDE 6Y / 6YI1 FEP 1x0.75 mm²IEC 60228 Cl. 51.627.209.7+180 °C / +205 °C300 m / 500 mRequest this size
VDE 6Y / 6YI1 FEP 1x1.0 mm²IEC 60228 Cl. 51.909.6012.7+180 °C / +205 °C300 m / 500 mRequest this size
VDE 6Y / 6YI1 FEP 1x1.5 mm²IEC 60228 Cl. 52.2014.4017.9+180 °C / +205 °C300 m / 500 mRequest this size
VDE 6Y / 6YI1 FEP 1x2.5 mm²IEC 60228 Cl. 52.6524.0026.4+180 °C / +205 °C300 m spoolRequest this size
VDE 6Y / 6YI1 FEP 1x4.0 mm²IEC 60228 Cl. 53.2038.0043.1+180 °C / +205 °C300 m spoolRequest this size
VDE 6Y / 6YI1 FEP 1x6.0 mm²IEC 60228 Cl. 54.4058.0065.9+180 °C / +205 °C300 m spoolRequest this size
VDE 6Y / 6YI1 FEP 1x10 mm²IEC 60228 Cl. 55.3096.00115.0+180 °C / +205 °C300 m spoolRequest this size
VDE 6Y / 6YI1 FEP 1x16 mm²IEC 60228 Cl. 58.00154.00175.0+180 °C / +205 °C300 m spoolRequest this size

ASCII part references for BOM and ERP entry: TF-PTFE5Y-1X0.5, TF-PTFE5Y-1X1.0, TF-PTFE5Y-1X1.5, TF-PTFE5Y-1X2.5, TF-FEP6Y-1X0.75, TF-FEP6Y-1X1.5, TF-FEP6Y-1X2.5, TF-FEP6Y-1X6.0.

Conductor plating ceiling: bare copper +130 °C, tinned copper (CuSn) +180 °C, silver-plated copper (CuAg) +200/+205 °C, nickel-plated copper (CuNi) +260 °C.

Standards

VDE 5Y & 6Y DIN VDE 0207-6, VDE 0881 & IEC Standards

VDE 5Y PTFE (260 °C, UL 11486) & VDE 6Y / 6YI1 FEP (205 °C) Metric Single-Core Wire standards and test references
Standard or specificationApplication
DIN VDE 0207-6 & DIN VDE 0881 / IEC 60673German and international fluoropolymer compound designations Type 5Y (PTFE, -190/+260 °C) and Type 6Y / 6YI1 (FEP, -100/+205 °C) for thin-wall equipment wires.
UL 758 Style 11486 (Engineered to Dimensional & Electrical Spec)Dual-referenced 260 °C / 200 °C PTFE single-core geometry on 28–12 AWG (0.09–4.0 mm²) gauges (third-party UL/VDE mark is not claimed).
IEC 60228 Class 5 & IEC 60332-1-2Fine-stranded copper conductor resistance limits and non-propagating vertical flame test.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and routine HV dielectric test documentation

IEC 60228 — Conductors of insulated cables (Class 5 fine-stranded copper)

IEC 60332-1-2 — Flame-retardant test for single insulated conductors

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.