VDE 5Y PTFE (260 °C, UL 11486) & VDE 6Y / 6YI1 FEP (205 °C) Metric Single-Core Wire
VDE 5Y PTFE (-190 °C to +260 °C, dual-referenced to UL 11486) and VDE 6Y / 6YI1 FEP (-100 °C to +205 °C) metric single-core wires (300/500 V, 600 V and 1,000 V) pair fine-stranded Class 5 tinned, silver-plated or nickel-plated copper conductors (0.14 to 16 mm²) with DIN VDE 0207-6 fluoropolymer insulation.
VDE 5Y PTFE and VDE 6Y / 6YI1 FEP metric single-core high-temperature wires provide European-standard chemical, cryogenic and thermal protection from 0.14 mm² up to 16 mm², covering -190 °C to +260 °C continuous service (+300 °C short-term) on sintered 5Y PTFE and -100 °C to +205 °C continuous service (+230 °C short-term) on melt-extruded 6Y / 6YI1 FEP.
European furnace builders, plastics extruder OEMs, automotive paint-shop engineers and chemical analyser manufacturers routinely specify metric DIN VDE 0207-6 codes (5Y for PTFE, 6Y / 6YI1 for FEP) or dual-rated UL Style 11486 where silicone single-core wires (SiF) cannot be used due to hot acid/solvent attack or strict LABS/PWIS silicone-free paint-line rules. Both insulation compounds achieve > 1–2 GOhm*km insulation resistance, < 0.01 % water absorption and non-flammable self-extinguishing performance per IEC 60332-1-2.
Select VDE 5Y PTFE with nickel-plated copper for +250 °C to +260 °C continuous duty (or silver-plated copper up to +200 °C and high-frequency skin-effect wiring), or choose VDE 6Y / 6YI1 FEP with Class 5 tinned or silver-plated copper when 100 % continuous splice-free spools up to +205 °C are required (MOQ 300 m / 500 m spools, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
VDE 5Y PTFE & VDE 6Y / 6YI1 FEP Wire Construction
Manufactured in strict accordance with DIN VDE 0207-6, DIN VDE 0881 and IEC 60228 Class 5, matching conductor plating directly to the continuous thermal ceiling.

| Component | Material and construction |
|---|---|
| 1. Fine-Stranded Plated Copper Conductor (Class 5 / AWG-Stranded) | Tinned copper (CuSn, up to +180 °C) or silver-plated copper (CuAg, up to +200/+205 °C) on VDE 6Y / 6YI1 FEP; silver-plated copper (+200 °C, UL 11486) or nickel-plated copper (CuNi, +260 °C) on VDE 5Y PTFE. |
| 2. DIN VDE 0207-6 Fluoropolymer Core Insulation (5Y or 6Y / 6YI1) | Paste-extruded and sintered polytetrafluoroethylene Type 5Y (-190 °C to +260 °C) or melt-extruded stress-crack-resistant fluorinated ethylene propylene Type 6Y / 6YI1 (-100 °C to +205 °C). |
| 3. VDE Standard Core Colours | Black, red, blue, brown, white, natural translucent, grey, violet, yellow, orange, pink and green-yellow protective earth. |
VDE 5Y, 6Y, 6YI1 & UL 11486 Designation Breakdown
- 5Y: DIN VDE 0207-6 polytetrafluoroethylene (PTFE) fluoropolymer insulation (-190 °C to +260 °C)
- 6Y / 6YI1: DIN VDE 0207-6 stress-crack-resistant fluorinated ethylene propylene (FEP, -100 °C to +205 °C)
- Type E / EE: 600 V AC (3.4 kV test) and 1,000 V AC (5.0 kV test) PTFE wall thickness classes per VDE 0881
- UL 11486: Dual-referenced 300/500 V thin-wall PTFE single-core geometry across 28–12 AWG (0.09–4.0 mm²)
- CuSn / CuAg / CuNi: Tinned (+180 °C), silver-plated (+200 °C) or nickel-plated (+260 °C) Class 5 copper conductors
VDE 5Y & 6Y Paint-Shop, Chemical, Kiln & Cryogenic Duties
Designed for silicone-free high-temperature cabinets, chemical vapour zones, cryogenic apparatus and industrial heating elements.

- Automotive cathodic dip-coating and paint-curing ovens where PWIS / LABS rules strictly prohibit outgassing silicone cables.
- Plastics injection-moulder nozzle heater bands, hot-runner manifolds, ceramic kilns, brickworks and commercial catering ovens.
- Electroplating baths, acid pickling switchgear, pharmaceutical autoclaves and chemical dosing cabinets exposed to solvents and halogens.
- Cryogenic liquid-nitrogen (-190 °C) sensor leads and high-frequency instrumentation requiring ultra-low dielectric loss (tan delta < 0.0003).
VDE 5Y PTFE vs VDE 6Y FEP vs SiF Silicone vs PFA
| Metric Wire Type | Thermal Range | Chemical & LABS/PWIS Profile | Put-Up Continuity & Best Use |
|---|---|---|---|
| VDE 5Y PTFE / UL 11486 (this page) | -190 °C to +260 °C (+300 °C peak) | Immune to all acids/solvents; 100 % LABS/silicone-free | Paste-extruded sintered PTFE for 260 °C kilns, cryogenics & soldering zones |
| VDE 6Y / 6YI1 FEP (this page) | -100 °C to +205 °C (+230 °C peak) | Acid/alkali/oil immune; 100 % LABS/silicone-free | Melt-extruded 100 % splice-free 300–500 m spools for paint shops & cabinets |
| SiF Silicone Single-Core (ID 1447) | -60 °C to +180 °C | Halogen-free elastomer; swells in hot aromatics/acids; contains silicone | Soft, economical cabinet & luminaire hook-up in dry ventilated air |
| PFA Single-Core (ID 3772) | -80 °C to +250 / +260 °C | Matches PTFE chemical/260 °C rating with melt-extruded continuity | Specify when 260 °C rating AND zero-splice 500 m+ spools are both required |
Always match conductor plating (CuSn +180 °C, CuAg +200 °C, CuNi +260 °C) to the maximum operating temperature.
VDE 5Y PTFE & VDE 6Y FEP Metric Wire RFQ Checklist
- Insulation code and voltage class: VDE 5Y PTFE (300/500 V UL 11486, 600 V Type E or 1,000 V Type EE) or VDE 6Y / 6YI1 FEP (300/500 V or 600 V).
- Metric conductor cross-section (0.14 mm² to 16 mm²) and plating (tinned CuSn, silver-plated CuAg, or nickel-plated CuNi for +260 °C).
- Whether 100 % single-piece splice-free spool continuity is mandatory (select 6Y FEP up to +205 °C or melt-extruded PFA up to +260 °C).
- Insulation colour (BK, RD, BU, BN, WH, TR, GN-YE) and total spool quantity (MOQ 300 m / 500 m per colour, 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Fluoropolymer & Silicone Cables
- Engineering guide: How to decode DIN VDE cable designations
- Compare VDE SiF 180 °C Single-Core Silicone Wire (0.25–240 mm²)
- Compare North American AWG UL 1180, UL 1213 & UL 1815 PTFE Wire
- Compare PTFE, PFA, FEP, ETFE and silicone temperature limits
VDE 5Y PTFE & VDE 6Y / 6YI1 FEP Frequently Asked Questions
What do VDE 5Y and VDE 6Y / 6YI1 mean in German fluoropolymer cable codes?
2 fluoropolymer insulation families defined in DIN VDE 0207-6: 5Y designates polytetrafluoroethylene (PTFE, -190 °C to +260 °C), while 6Y and 6YI1 designate stress-crack-resistant fluorinated ethylene propylene (FEP, -100 °C to +205 °C).
Which conductor plating should I specify on VDE 5Y PTFE wire for +260 °C continuous operation?
Nickel-plated copper (CuNi) is mandatory for continuous +250 °C to +260 °C operation; silver-plated copper (CuAg) is rated up to +200 °C continuous, and tinned copper (CuSn) is rated up to +180 °C.
Why are VDE 5Y PTFE and VDE 6Y FEP wires mandatory in automotive paint-curing lines?
0 % silicone content makes VDE 5Y PTFE and VDE 6Y FEP completely free of paint-wetting impairment substances (LABS / PWIS-free), eliminating crater defects caused by outgassing silicone wires.
What is the difference between VDE 5Y PTFE and VDE 6Y FEP spool continuity?
300 m to 500 m VDE 6Y FEP spools are melt-extruded in 100 % continuous single lengths, whereas sintered VDE 5Y PTFE is ram/paste-extruded from billets and may contain spark-tested factory lengths per VDE 0881 unless melt-extruded PFA is specified.
What is the minimum order quantity and lead time for VDE 5Y and VDE 6Y single-core wire?
300 m or 500 m standard factory spools per cross-section and colour, manufactured in 7 to 45 working days depending on conductor plating.
VDE 5Y PTFE & VDE 6Y / 6YI1 FEP Metric Schedules (0.14–16 mm²)
VDE 5Y & 6Y Voltage, Temperature, Plating & Spool Summary
- European metric mm² schedules: True metric 0.14 to 16 mm² cross-sections per DIN VDE 0207-6, DIN VDE 0881 and IEC 60228 Class 5 for European machinery & furnace drawings
- VDE 5Y PTFE (-190 to +260 °C): Non-melting sintered PTFE wall in 300/500 V (UL 11486), 600 V Type E (3.4 kV test) and 1,000 V Type EE (5.0 kV test) up to +300 °C peak
- VDE 6Y / 6YI1 FEP (-100 to +205 °C): Continuous melt-extruded stress-crack-resistant FEP wall in 300/500 V and 600 V (2.5 kV test) for long splice-free cabinet harnesses
- Silicone-free & PWIS/LABS clean: 100 % free of silicone and lacquer-wetting-impairment substances for automotive paint-drying ovens, chemical plants and cleanrooms
- Standard factory spool supply: Delivered on 300 m or 500 m factory spools per colour (MOQ 300 m) with a 7 to 45 working days manufacturing lead time
| Parameter | Value |
|---|---|
| Rated voltage | 300/500 V (VDE 6YI1 and UL 11486), 600 V (VDE 6Y and VDE 5Y Type E, 2.5 to 3.4 kV test) and 1000 V (VDE 5Y Type EE, 5.0 kV AC test) |
| Metric cross-section range | 0.14 mm2 to 16 mm2 (approx. 26 AWG to 6 AWG) in fine-stranded Class 5 tinned, silver-plated or nickel-plated copper |
| Fluoropolymer insulation grades | DIN VDE 0207-6 Type 5Y sintered PTFE (-190 C to +260 C) and Type 6Y / 6YI1 melt-extruded FEP (-100 C to +205 C), 100% silicone-free |
| Bending radius and insulation resistance | 4x OD fixed installation and 10x OD occasional flexing, with at least 1 GOhm*km (5Y PTFE) to 2 GOhm*km (6Y FEP) insulation resistance |
| Standard put-up and lead time | 300 m or 500 m standard factory spools per colour (MOQ 300 m) manufactured in 7 to 45 working days |
| Standards compliance note | Engineered to DIN VDE 0207-6, DIN VDE 0881, IEC 60673 and UL 758 Style 11486 specifications (third-party VDE or UL mark is not claimed) |
| Chemical and moisture immunity | Less than 0.01% water absorption and complete resistance to concentrated acids, alkalis, fuels, hydraulic fluids, ozone and UV |
VDE 5Y PTFE (-190 to +260 °C, 600/1000 V & UL 11486) Metric Schedule
| Model & Cross-Section | Equiv. AWG / Strands | 600 V / UL 11486 OD (mm) | 1000 V Type EE OD (mm) | Copper Index (kg/km) | Approx. Weight 600V / 1000V (kg/km) | Standard Spool MOQ | Next step |
|---|---|---|---|---|---|---|---|
| VDE 5Y PTFE 1x0.14 mm² | 26 AWG (7 or 19w) | 0.99 | 1.24 | 1.4 | 2.1 / 2.8 | 300 m / 500 m | Request this size |
| VDE 5Y PTFE 1x0.25 mm² | 24 AWG (19w) | 1.12 | 1.37 | 2.4 | 3.2 / 4.1 | 300 m / 500 m | Request this size |
| VDE 5Y PTFE 1x0.38 mm² | 22 AWG (19w) | 1.27 | 1.52 | 3.6 | 4.6 / 5.7 | 300 m / 500 m | Request this size |
| VDE 5Y PTFE 1x0.50 mm² | 20 AWG (19w) | 1.47 | 1.72 | 5.6 | 6.8 / 8.1 | 300 m / 500 m | Request this size |
| VDE 5Y PTFE 1x0.75 mm² | 19 AWG (19w) | 1.65 | 1.90 | 7.2 | 9.1 / 10.6 | 300 m / 500 m | Request this size |
| VDE 5Y PTFE 1x1.0 mm² | 18 AWG (19w) | 1.74 | 2.00 | 9.6 | 11.5 / 13.7 | 300 m / 500 m | Request this size |
| VDE 5Y PTFE 1x1.5 mm² | 16 AWG (19w) | 2.04 | 2.26 | 14.4 | 17.2 / 21.4 | 300 m / 500 m | Request this size |
| VDE 5Y PTFE 1x2.5 mm² | 14 AWG (19w) | 2.40 | 2.76 | 24.0 | 27.8 / 34.0 | 300 m spool | Request this size |
| VDE 5Y PTFE 1x4.0 mm² | 12 AWG (37w) | 3.10 | 3.50 | 38.0 | 44.5 / 51.0 | 300 m spool | Request this size |
| VDE 5Y PTFE 1x6.0 mm² | 10 AWG (37w) | 4.20 | 4.65 | 58.0 | 68.0 / 76.5 | 300 m spool | Request this size |
| VDE 5Y PTFE 1x10 mm² | 8 AWG (133w) | 5.30 | 5.80 | 96.0 | 116.0 / 128.0 | 300 m spool | Request this size |
| VDE 5Y PTFE 1x16 mm² | 6 AWG (133w) | 7.80 | 8.30 | 154.0 | 178.0 / 194.0 | 300 m spool | Request this size |
VDE 6Y & 6YI1 FEP (-100 to +205 °C, 300/500 V & 600 V) Metric Schedule
| Model & Cross-Section | Conductor Class | Nom. Outer Ø (mm) | Copper Index (kg/km) | Approx. Weight (kg/km) | Continuous Temp. (TPC / SPC) | Standard Spool MOQ | Next step |
|---|---|---|---|---|---|---|---|
| VDE 6Y / 6YI1 FEP 1x0.14 mm² | IEC 60228 Cl. 5 | 1.00 | 1.35 | 2.6 | +180 °C / +205 °C | 300 m / 500 m | Request this size |
| VDE 6Y / 6YI1 FEP 1x0.25 mm² | IEC 60228 Cl. 5 | 1.16 | 2.40 | 4.1 | +180 °C / +205 °C | 300 m / 500 m | Request this size |
| VDE 6Y / 6YI1 FEP 1x0.50 mm² | IEC 60228 Cl. 5 | 1.42 | 4.80 | 8.0 | +180 °C / +205 °C | 300 m / 500 m | Request this size |
| VDE 6Y / 6YI1 FEP 1x0.75 mm² | IEC 60228 Cl. 5 | 1.62 | 7.20 | 9.7 | +180 °C / +205 °C | 300 m / 500 m | Request this size |
| VDE 6Y / 6YI1 FEP 1x1.0 mm² | IEC 60228 Cl. 5 | 1.90 | 9.60 | 12.7 | +180 °C / +205 °C | 300 m / 500 m | Request this size |
| VDE 6Y / 6YI1 FEP 1x1.5 mm² | IEC 60228 Cl. 5 | 2.20 | 14.40 | 17.9 | +180 °C / +205 °C | 300 m / 500 m | Request this size |
| VDE 6Y / 6YI1 FEP 1x2.5 mm² | IEC 60228 Cl. 5 | 2.65 | 24.00 | 26.4 | +180 °C / +205 °C | 300 m spool | Request this size |
| VDE 6Y / 6YI1 FEP 1x4.0 mm² | IEC 60228 Cl. 5 | 3.20 | 38.00 | 43.1 | +180 °C / +205 °C | 300 m spool | Request this size |
| VDE 6Y / 6YI1 FEP 1x6.0 mm² | IEC 60228 Cl. 5 | 4.40 | 58.00 | 65.9 | +180 °C / +205 °C | 300 m spool | Request this size |
| VDE 6Y / 6YI1 FEP 1x10 mm² | IEC 60228 Cl. 5 | 5.30 | 96.00 | 115.0 | +180 °C / +205 °C | 300 m spool | Request this size |
| VDE 6Y / 6YI1 FEP 1x16 mm² | IEC 60228 Cl. 5 | 8.00 | 154.00 | 175.0 | +180 °C / +205 °C | 300 m spool | Request this size |
ASCII part references for BOM and ERP entry: TF-PTFE5Y-1X0.5, TF-PTFE5Y-1X1.0, TF-PTFE5Y-1X1.5, TF-PTFE5Y-1X2.5, TF-FEP6Y-1X0.75, TF-FEP6Y-1X1.5, TF-FEP6Y-1X2.5, TF-FEP6Y-1X6.0.
Conductor plating ceiling: bare copper +130 °C, tinned copper (CuSn) +180 °C, silver-plated copper (CuAg) +200/+205 °C, nickel-plated copper (CuNi) +260 °C.
VDE 5Y & 6Y DIN VDE 0207-6, VDE 0881 & IEC Standards
| Standard or specification | Application |
|---|---|
| DIN VDE 0207-6 & DIN VDE 0881 / IEC 60673 | German and international fluoropolymer compound designations Type 5Y (PTFE, -190/+260 °C) and Type 6Y / 6YI1 (FEP, -100/+205 °C) for thin-wall equipment wires. |
| UL 758 Style 11486 (Engineered to Dimensional & Electrical Spec) | Dual-referenced 260 °C / 200 °C PTFE single-core geometry on 28–12 AWG (0.09–4.0 mm²) gauges (third-party UL/VDE mark is not claimed). |
| IEC 60228 Class 5 & IEC 60332-1-2 | Fine-stranded copper conductor resistance limits and non-propagating vertical flame test. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and routine HV dielectric test documentation
IEC 60228 — Conductors of insulated cables (Class 5 fine-stranded copper)
IEC 60332-1-2 — Flame-retardant test for single insulated conductors
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
PTFE Hook-Up Wire — UL 1180, UL 1199, UL 1213, UL 1815 & UL 1584 (200–260 °C)
A related cable option for a different application or duty profile.
View productFEP Hook-Up Wire — UL 1330, UL 1331, UL 1332 & UL 1333 Wire (150–200 °C, 300/600 V)
A related cable option for a different application or duty profile.
View productPFA Hook-Up Wire — UL 1726, UL 1727 & UL 10362 Extruded Wire (250 °C, 300/600 V)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.