High Temperature Cables TEBAOFLEX

GN500 & GN500-01 500 V Metric Mica-Tape & Fiberglass Braided High-Temperature Wire (350–500 °C)

GN500 and GN500-01 (TF-GN500-MICA-WIRE) are 500 V metric mica-tape and woven fiberglass braided high-temperature fire-resistant lead wires spanning 0.5 mm² to 50 mm². Supplied in +350 °C bare/tinned copper (GN500-01) and +500 °C continuous 27 % nickel-clad or pure nickel builds (GN500-Ni27 / GN500-Ni) for industrial furnaces, band heaters and steelworks.

Product information
SKU
TF-GN500-MICA-WIRE
Brand
TEBAOFLEX
Product overview

GN500 and GN500-01 500 V metric mica-tape and fiberglass-braided fire-resistant wires supply single-core heating-element, thermocouple-head and burner-igniter connections from 0.5 mm² up to 50 mm² where ambient temperatures exceed the +180 °C ceiling of SiF silicone wire and the +260 °C ceiling of PTFE/PFA fluoropolymer wire.

Many supplier datasheets market bare-copper GN500-01 as a 500 °C wire while burying a +350 °C limit in fine print—because bare copper oxidizes rapidly and sheds conductive scale above +300 to +350 °C even though phlogopite mica withstands +800 °C. TEBAOFLEX separates both grades explicitly: economical GN500-01 uses bare or tinned Class 5 copper for -60 °C to +350 °C drying ovens and platen heaters, whereas GN500-Ni27 uses ASTM B355 Class 27 (27 % by weight) nickel-clad copper (or pure Ni99 on GN500-Ni) to deliver genuine +500 °C continuous (+550 °C peak) service without conductor embrittlement.

Specify metric GN500-Ni27 or GN500-01 when equipment drawings call out DIN / IEC metric terminals (0.5–50 mm²) or Chinese/export codes GN500, GN500-01, YGZP or AGRP; specify North American MGT / UL 5107 / UL 5400 when BOMs require 24 AWG to 4/0 AWG 600 V UL-style gauges. MOQ 300 m per size/colour on 0.5–4.0 mm² and 50 m on 6.0–50 mm², shipped in 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

GN500 & GN500-01 Metric Mica-Glass Wire Construction

Constructed with concentric metric Class 5 conductors, 50 %+ overlapped phlogopite/synthetic mica barrier tapes and resin-locked alkali-free E-glass braiding.

Clean 2D concentric cross-section of GN500 metric mica-glass wire showing white woven fiberglass outer braid, golden-amber multi-turn mica-tape insulation ring and 19-strand nickel-clad copper center
500 V GN500 concentric cross-section: stranded CuNi27 (or bare Cu on GN500-01) core, multi-layer mica barrier and high-temperature treated fiberglass braid.
GN500 & GN500-01 500 V Metric Mica-Tape & Fiberglass Braided High-Temperature Wire (350–500 °C) construction
ComponentMaterial and construction
1. Metric Stranded Conductor (Bare Cu, 27 % Nickel-Clad Cu or Pure Ni)Fine-stranded bare copper on GN500-01 (up to +350 °C), 27 % nickel-clad copper CuNi27 on GN500-Ni27 (up to +500 °C continuous), or pure nickel Ni99 on GN500-Ni (up to +600 °C).
2. Multi-Turn Helical Phlogopite / Synthetic Mica Tape InsulationTwo or more overlapped calcination-stable mica tapes forming a 500 V AC (2,000 V AC test) dielectric barrier that will not melt, drip or carbonize.
3. Woven Alkali-Free E-Glass Reinforcing BraidTightly braided fiberglass jacket providing mechanical abrasion, cut-through and tight-bend support (minimum fixed bend radius 6× OD).
4. High-Temperature Silicone or PTFE Dispersion FinishCured inorganic-silicone or PTFE emulsion coating in white (with colour tracers) or solid colours (red, blue, black, brown, yellow) preventing glass fray.

GN500, GN500-01 & GN500-Ni27 Grade Breakdown

  • GN: High-temperature inorganic mica-tape & woven fiberglass insulated equipment lead wire
  • 500: 500 V AC rated voltage class (and +500 °C continuous rating when paired with CuNi27)
  • -01 (GN500-01): Bare annealed copper conductor economical grade rated -60 °C to +350 °C continuous
  • -Ni27 (GN500-Ni27): 27 % concentric nickel-clad copper conductor (ASTM B355 Class 27) rated +500 °C continuous
  • -Ni (GN500-Ni): Pure nickel Ni99 stranded conductor grade for extreme +550 °C to +600 °C heater terminals
Applications

GN500 Industrial Heaters, Annealing Furnaces & Kiln Duty

Built for fixed internal and furnace-adjacent high-temperature wiring in metallurgy, plastics machinery, glass, ceramics and industrial heating.

White fiberglass-braided GN500 high-temperature mica wires crimped with nickel ring lugs onto ceramic heater terminal studs inside an industrial electric annealing furnace
Ceramic terminal blocks and tubular heating elements in an annealing kiln wired with metric GN500 +500 °C mica-glass leads.
  • Extruder barrel ceramic band heaters, injection-moulding hot-runner manifolds, cartridge heaters and die-head heating rings.
  • Electric annealing, tempering, carburizing and vacuum heat-treatment furnace terminal boxes and heating-element bus jumpers.
  • Steelworks ladle preheaters, EAF / BOF lance junction boxes, glass-melting forehearth heaters and ceramic tunnel-kiln igniters.
  • Foundry core-baking ovens, power-plant air-preheater dampers, industrial catering ovens and high-intensity discharge lamp housings.

GN500 (Metric mm²) vs MGT (AWG) vs TGGT vs VDE 5Y PTFE

GN500 / GN500-01 (Metric mm²) vs MGT / UL 5107 (AWG) vs TGGT (250 °C) vs N2GFAF / SiF-GL (180–200 °C)
Lead Wire FamilySizing & VoltageContinuous Temp & InsulationWhen to Specify
GN500-Ni27 & GN500-01 (this page)Metric 0.5–50 mm²; 500 V+350 °C (bare Cu) / +500 °C (CuNi27); mica tape + E-glass braidMetric DIN/IEC heater & furnace BOMs from +300 °C to +500 °C
MGT / UL 5107 / UL 540024 AWG–4/0 AWG; 300/600 V+450 °C / +538–550 °C; CuNi27 + mica-glass + glass braidNorth American AWG-sized kilns, steel mills & UL-style OEM harnesses
TGGT / UL 5256 / UL 519624 AWG–4/0 AWG; 300/600 V+250 °C; 2% NPC + sintered PTFE tape + glass braidMoist commercial ovens & chemical heaters up to +250 °C requiring moisture seal
VDE 5Y PTFE / UL 11486Metric 0.14–16 mm²; 500/1000 V-190 to +260 °C; solid extruded virgin PTFEWet chemical immersion or tight-cabinet metric wiring up to +260 °C

Mica-glass braided wires (GN500 and MGT) breath in high humidity and are not designed for liquid immersion; below +250/+260 °C in wet washdown zones, specify TGGT or extruded PFA/PTFE wire.

GN500 & GN500-01 Mica-Glass Lead Wire RFQ Checklist

  • Grade selection: GN500-01 (+350 °C bare copper), GN500-Ni27 (+500 °C 27 % nickel-clad copper) or GN500-Ni (+600 °C pure nickel).
  • Metric cross-section (0.5 mm² to 50 mm²) and outer braid finish (silicone resin PFAS-free vs PTFE emulsion).
  • Outer braid colour (natural white with tracer, or solid red, blue, black, brown, yellow).
  • Order quantity per size/colour (MOQ 300 m coil on 0.5–4.0 mm², 50 m reel on 6.0–50 mm²; 7 to 45 working days).

Related selection resources

GN500 & GN500-01 Mica-Fiberglass High-Temp Wire FAQ

Why is GN500-01 rated +350 °C while GN500-Ni27 reaches +500 °C continuous?

The conductor sets the ceiling: phlogopite mica and E-glass withstand over +550 °C, but bare copper in GN500-01 oxidizes and flakes above +300 to +350 °C; upgrading to 27 % nickel-clad copper (GN500-Ni27) blocks oxygen diffusion up to +500 °C continuous.

What is the difference between metric GN500 wire and North American MGT wire?

Both use mica-tape insulation under a treated fiberglass braid, but GN500 is built to IEC metric cross-sections (0.5 mm² to 50 mm², 500 V) matching metric DIN crimp lugs, whereas MGT is built to UL 5107 / 5128 AWG gauges (24 AWG to 4/0 AWG, 300/600 V).

Can GN500-Ni27 or GN500-01 be terminated with standard tin solder?

No — tin-lead and lead-free solders melt between +183 °C and +227 °C, and 27 % nickel cladding resists rosin wetting; always terminate GN500 leads using high-temperature nickel-plated or stainless crimp lugs or spot welding.

Is GN500 mica-fiberglass wire waterproof for outdoor immersion or steam washdown?

No — lapped mica tape and woven fiberglass resist ambient furnace moisture via silicone/PTFE impregnation, but they are not hermetically waterproof; for wet washdown up to +260 °C, specify extruded PFA or VDE 5Y PTFE wire.

What is the minimum order quantity and lead time for GN500 and GN500-01?

300 m standard coils on 0.5 mm² through 4.0 mm² sizes and 50 m reels on 6.0 mm² through 50 mm² sizes, manufactured in 7 to 45 working days.

Specifications

GN500-Ni27 (+500 °C) & GN500-01 (+350 °C) Metric Schedule

GN500 500 V Voltage, Conductor Metallurgy & Spool Summary

  • True metric 0.5–50 mm² sizing: Purpose-built IEC 60228 Class 5 metric cross-sections (0.5 to 50 mm²) for European, CIS, Middle East and Asian furnace BOMs where AWG MGT wire mismatches lugs
  • Transparent +350 °C vs +500 °C metallurgy: GN500-01 bare copper serves -60 to +350 °C heating zones economically; GN500-Ni27 (27 % nickel-clad copper) prevents copper scaling up to +500 °C continuous
  • Multi-layer phlogopite / synthetic mica: Helically lapped high-dielectric mica tapes bonded beneath a silicone- or PTFE-impregnated E-glass outer braid maintain 500 V insulation under direct flame
  • Non-fraying clean-strip finish: High-temperature cured silicone/PTFE resin dispersion locks the fiberglass weave against pushback during high-speed cutting and nickel-lug crimping
  • 300 m coils & 50 m heavy reels: Supplied in 300 m standard coils/spools on 0.5–4.0 mm² lead sizes and 50 m reels on 6.0–50 mm² heavy bus leads in 7 to 45 working days
GN500 & GN500-01 500 V Metric Mica-Tape & Fiberglass Braided High-Temperature Wire (350–500 °C) technical data
ParameterValue
Rated voltage500 V AC nominal with 2000 V AC 1-minute routine dielectric withstand and spark test
Metric cross-section range0.5, 0.75, 1.0, 1.5, 2.5, 4.0, 6.0, 10, 16, 25, 35 and 50 mm2 fine-stranded conductors
Thermal and conductor gradesGN500-01 (-60 C to +350 C, bare copper), GN500-Ni27 (-60 C to +500 C continuous, 27% nickel-clad copper) and GN500-Ni (up to +600 C, pure nickel)
Minimum bend radius6x outer diameter for fixed furnace and heater harness installation (8x OD on 16 to 50 mm2 heavy leads)
Standard put-up and lead time300 m minimum order coils on 0.5 to 4.0 mm2 and 50 m reels on 6.0 to 50 mm2; 7 to 45 working days lead time
Fire and smoke behaviourNon-melting inorganic mica-glass barrier maintains circuit insulation during direct flame exposure; PFAS-free silicone-finish option available
Termination methodHigh-temperature nickel or stainless-steel crimp ring/spade lugs or resistance spot-welding (ordinary tin-lead solder melts above +183 C)

GN500-Ni27 (+500 °C Continuous, 27 % Nickel-Clad Copper) Metric Schedule

GN500-Ni27 (+500 °C Continuous, 27 % Nickel-Clad Copper) 500 V Metric Mica-Tape & Fiberglass Wire — Dimensional & Electrical Schedule
Model & Cross-SectionCuNi27 Stranding (No. × Ø mm)Conductor Ø (mm)Nom. OD (mm)Max. R at 20 °C (Ω/km)Ref. Current at +400 °C Air (A)Approx. Weight (kg/km)Standard MOQNext step
GN500-Ni27 0.5 mm²16 × 0.200.952.352.84.510.5300 m coilRequest this size
GN500-Ni27 0.75 mm²24 × 0.201.152.535.26.013.8300 m coilRequest this size
GN500-Ni27 1.0 mm²32 × 0.201.322.726.47.517.2300 m coilRequest this size
GN500-Ni27 1.5 mm²30 × 0.251.603.117.910.023.5300 m coilRequest this size
GN500-Ni27 2.5 mm²49 × 0.252.053.610.814.535.0300 m coilRequest this size
GN500-Ni27 4.0 mm²56 × 0.302.604.36.7520.052.5300 m coilRequest this size
GN500-Ni27 6.0 mm²84 × 0.303.205.04.5026.575.050 m reelRequest this size
GN500-Ni27 10 mm²80 × 0.404.256.42.6238.0124.050 m reelRequest this size
GN500-Ni27 16 mm²126 × 0.405.357.81.6552.0190.050 m reelRequest this size
GN500-Ni27 25 mm²196 × 0.406.709.51.0670.0292.050 m reelRequest this size
GN500-Ni27 35 mm²276 × 0.407.9511.00.75588.0402.050 m reelRequest this size
GN500-Ni27 50 mm²396 × 0.409.6013.00.528112.0568.050 m reelRequest this size

GN500-01 (+350 °C Bare Copper) Metric Mica Wire Schedule

GN500-01 (+350 °C Continuous, Bare Annealed Copper Economical Grade) 500 V Metric Fire-Resistant Mica Wire Schedule
Model & Cross-SectionBare Cu Stranding (No. × Ø mm)Nom. OD (mm)Max. R at 20 °C (Ω/km)Ref. Current at +250 °C Air (A)Approx. Weight (kg/km)Standard MOQNext step
GN500-01 0.75 mm²24 × 0.202.526.08.513.5300 m coilRequest this size
GN500-01 1.0 mm²32 × 0.202.719.510.516.8300 m coilRequest this size
GN500-01 1.5 mm²30 × 0.253.113.314.023.0300 m coilRequest this size
GN500-01 2.5 mm²49 × 0.253.67.9819.534.2300 m coilRequest this size
GN500-01 4.0 mm²56 × 0.304.34.9526.051.5300 m coilRequest this size
GN500-01 6.0 mm²84 × 0.305.03.3034.073.850 m reelRequest this size
GN500-01 10 mm²80 × 0.406.41.9148.0122.050 m reelRequest this size
GN500-01 16 mm²126 × 0.407.81.2166.0187.050 m reelRequest this size
GN500-01 25 mm²196 × 0.409.50.78088.0288.050 m reelRequest this size
GN500-01 35 mm²276 × 0.4011.00.554110.0396.050 m reelRequest this size

Note on DC resistance: 27 % nickel-clad copper (ASTM B355 Class 27) has approximately 72 % IACS conductivity compared with 100 % IACS bare copper, yielding slightly higher 20 °C resistance while preventing destructive oxide scaling between +350 °C and +500 °C. Final values are confirmed on the quotation drawing.

ASCII part references for BOM and ERP entry: TF-GN500-NI27-1.5, TF-GN500-NI27-2.5, TF-GN500-NI27-4.0, TF-GN500-NI27-6.0, TF-GN500-NI27-10, TF-GN500-NI27-16, TF-GN500-01-1.5, TF-GN500-01-2.5, TF-GN500-01-4.0, TF-GN500-01-6.0.

Standards

GN500 Reference Standards (IEC 60228, ASTM B355 & Fire Integrity)

GN500 & GN500-01 500 V Metric Mica-Tape & Fiberglass Braided High-Temperature Wire (350–500 °C) standards and test references
Standard or specificationApplication
IEC 60228 & ASTM B355 Class 27 ReferenceMetric flexible copper stranding geometry and 27 % concentric nickel cladding thickness for +500 °C oxidation immunity.
IEC 60331 & IEC 60332-1-2 Fire-Integrity PrinciplesCalcination-resistant mica-tape dielectric barrier and vertical flame propagation self-extinguishing performance.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and 2,000 V AC spark/dielectric verification

ASTM B355 — Standard Specification for Nickel-Coated Soft or Annealed Copper Wire

IEC 60228 — Conductors of insulated metric cables

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.