TF-ACIH 35–40 kW Air-Cooled Induction Heating & Weld Preheat / PWHT Bulk Cable (1,000 V, 350–600 A, +450 °C)
TF-ACIH (TF-ACIH-BULK) is a 1,000 V AC high-frequency air-cooled induction heating, weld-preheat and post-weld heat-treatment (PWHT) bulk cable rated up to +450 °C continuous cable surface temperature (35–40 kW+ / 250–600 A without liquid coolant). Available with anodized-aluminum HF Litz (TF-ACIH-AL) or 27 % nickel-clad copper HF Litz (TF-ACIH-CU) under mica-fiberglass insulation and AISI 304 stainless-steel braid, supplied strictly in bulk 50 m+ reels.
TF-ACIH 1,000 V air-cooled high-frequency induction heating bulk cable enables heat-treatment service contractors, induction-blanket manufacturers and heavy fabricators to wind custom weld-preheating, hydrogen-bakeout and post-weld heat-treatment (PWHT) coils without circulating cooling liquid, supporting 250 A to 600 A (35 kW to 50 kW at 5–30 kHz) across +204 °C to +788 °C+ workpiece cycles.
In cross-country pipeline tie-ins, offshore wind foundation yards, pressure-vessel shops and sub-zero arctic construction sites, water-cooled induction hoses freeze, leak or suffer kW skin-effect overheating if ordinary welding cable is wrapped around a pipe. TF-ACIH combines individually oxide-insulated anodized-aluminum HF strands (TF-ACIH-AL16, weighing just 0.53 kg/m so one technician can wrap 15–24 m coils effortlessly) or 27 % nickel-clad copper HF Litz bundles (TF-ACIH-CU25 to CU95) beneath calcination-stable mica-fiberglass thermal barriers and a non-magnetic AISI 304 stainless-steel mechanical strain-relief braid.
Important supply boundary: TEBAOFLEX manufactures and supplies TF-ACIH strictly as unterminated bulk cable by the meter (minimum order quantity 50 m per specification on factory reels, or factory-cut into standard 9.1 m / 30 ft, 15.0–15.2 m / 50 ft and 24.4 m / 80 ft field coil lengths totaling at least 50 m; proprietary inverter twist-lock plugs are customer-fitted). For closed-loop > 50 kW forging/melting coils, switch to TF-HC10K water-cooled hollow-core Litz cable. Lead time 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
TF-ACIH +450 °C Air-Cooled HF Litz & 304 Braid Design
Engineered for 5 kHz to 30 kHz high-frequency skin-effect suppression, +450 °C thermal endurance and rugged field-wrapping abrasion survival.

| Component | Material and construction |
|---|---|
| 1. High-Frequency Insulated Litz Core (Anodized Al or CuNi27) | Anodized-oxide-insulated aluminum HF-stranded Litz on lightweight TF-ACIH-AL16 (350 A), or inorganic/high-temp insulated 27 % nickel-clad copper Litz on TF-ACIH-CU (250–600 A). |
| 2. 1,000 V Phlogopite/Synthetic Mica Dielectric Barrier | Multi-turn overlapped high-temperature mica tapes providing 1,000 V AC (3,000 V AC test) primary dielectric strength up to +450/+500 °C without melting. |
| 3. Thick Woven Alkali-Free Fiberglass / Silica Thermal Cushion | Braided high-bulk glass thermal insulation limiting heat soak from the hot pipe/vessel into the Litz core when laid over a ceramic preheat blanket. |
| 4. Non-Magnetic AISI 304 Stainless-Steel Braid (or Silicone-Glass Jacket) | Austenitic 304 stainless-steel wire braid mechanical strain relief (-SS) for severe jobsite abrasion, or high-temp silicone-impregnated fiberglass (-SG) for flexible blanket sewing. |
TF-ACIH Anodized-Al, CuNi27 & Cut-Length Breakdown
- TF-ACIH-AL16: 16 mm OD lightweight anodized-aluminum HF-stranded Litz induction cable (350 A / 35–40 kW, 0.53 kg/m)
- TF-ACIH-CU<mm²>: 27 % nickel-clad copper HF Litz induction cable in 25, 35, 50, 70 or 95 mm² (260 A to 600 A)
- -SS (Stainless Braid): Exterior non-magnetic AISI 304 stainless-steel wire braid for open jobsite pipe wrapping and tension relief
- -SG (Silicone-Glass): Flexible silicone-treated fiberglass outer braid for sewing inside flexible induction preheating blankets
- MOQ 50 m Bulk: Supplied as unterminated bulk reel or multi-coil factory cuts >= 50 m total (machine plugs customer-fitted)
TF-ACIH Pipeline Preheat, PWHT & Induction Blanket OEMs
Designed for induction-heating OEM blanket builders, PWHT field-service fleets, shipyards, pipeline spreads and pressure-vessel fabricators.

- Oil, gas, refinery and petrochemical Chrome-Moly (P11, P22, P91) process-piping and cross-country pipeline girth-weld preheating and PWHT.
- Offshore wind monopile, transition-piece, LNG tank and heavy structural-steel thick-plate preheating (20–150 mm wall) up to +204–350 °C.
- Power-plant steam drum, boiler header, hydrocracker pressure vessel, turbine casing shrink-fitting and weld hydrogen-diffusion bakeout.
- OEM fabrication of flexible air-cooled induction heating blankets, flat plate inductors and custom furnace coil harnesses from bulk reel stock.
TF-ACIH Air-Cooled Induction vs Water-Cooled Litz vs Dry Litz
| HF Induction Cable | Cooling & Temp Limit | Supply Format & MOQ | Where to Deploy |
|---|---|---|---|
| TF-ACIH-AL / -CU (this page) | Ambient air; +450 °C cable surface | Bulk reel / coil cuts (MOQ 50 m) | Pipe/vessel wrap preheat & PWHT coils over thermal blankets |
| Shielded 1 kV HF Litz (WC 5875) | Ambient air; +105 to +180 °C | Bulk reel (MOQ 50 m) | Cabinet-to-transformer feeder leads away from hot steel |
| TF-HC10K Hollow-Core Litz | 6 bar water; <= 10 kHz (up to 3,700 A) | Terminated assembly (MOQ 2 pcs) | 50–500 kW billet forging & induction hardening coils |
| CW-FEP Constant-Wattage Trace | 120–480 V AC mains resistance; +200 °C | Bulk reel (MOQ 300 m) | Process-pipe freeze protection & <= +200 °C temperature maintenance |
Do not wrap standard rubber welding cable (H01N2-D or 600 V EPDM) on 10–25 kHz induction preheaters: uninsulated copper strands suffer severe HF skin-effect heating while +90 °C rubber melts onto the blanket.
TF-ACIH Bulk Induction Heating Cable (50 m MOQ) RFQ Checklist
- Conductor series: lightweight anodized-aluminum HF Litz (TF-ACIH-AL16, 350 A) or 27 % nickel-clad copper HF Litz (TF-ACIH-CU25 to CU95).
- Outer protection: AISI 304 stainless-steel wire braid (-SS for open pipe wrapping) vs silicone-glass braid (-SG for sewn induction blankets).
- Inverter output frequency (kHz), maximum RMS current (A), voltage (up to 1,000 V) and target workpiece temperature (°C).
- Total meterage (>= 50 m MOQ per model) and whether delivered as continuous 50 m / 100 m reel or pre-cut unterminated lengths (7 to 45 working days).
Related selection resources
- Browse all High-Temperature Induction, Mica & Furnace Cables
- Pair with 1 kV Shielded High-Frequency Litz Inverter Feeder Cable
- Compare TF-HC10K 10 kHz Water-Cooled Hollow-Core Litz Induction Cable
- Compare GN500 +500 °C Metric Mica-Fiberglass Resistance Heater Wire
- Pair with Type K / N Thermocouple Wire for PWHT Temperature Control
- Engineering guide: High-temperature insulation & conductor limits above 260 °C
TF-ACIH Air-Cooled Induction Preheat & PWHT Cable FAQ
Does TEBAOFLEX supply TF-ACIH as single pre-plugged 9.1 m or 15.2 m cords, or as bulk cable?
Bulk cable only (MOQ 50 m): TEBAOFLEX manufactures and supplies TF-ACIH on 50 m to 200 m factory reels (or pre-cut into multiple unterminated 9.1 m, 15.2 m or 24.4 m lengths totaling >= 50 m) for PWHT contractors, service shops and blanket OEMs who crimp their own machine plugs.
Why choose anodized-aluminum HF Litz (TF-ACIH-AL16) over nickel-clad copper Litz (TF-ACIH-CU50)?
Weight and oxide insulation: aluminum's natural hard-anodized Al2O3 layer withstands +450 °C+ without organic enamel burnout while cutting cable weight to 8 kg per 15 m coil—roughly 35 % lighter than copper for overhead pipeline wrapping; choose CuNi27 when crimping standard copper/nickel lugs.
How can a +450 °C rated TF-ACIH cable heat a steel vessel to +650 °C or +788 °C during PWHT?
Induction eddy currents generate heat directly inside the steel wall—not inside the cable—while a 25–50 mm ceramic or silica thermal blanket placed between the steel and TF-ACIH keeps the outer cable surface safely below +450 °C.
Why is non-magnetic AISI 304 stainless steel used for the outer braid on TF-ACIH-SS?
Magnetic 400-series or galvanized carbon-steel wire braids would inductively self-heat inside the 5–30 kHz alternating field; austenitic AISI 304 stainless steel has low magnetic permeability, providing cut/pull strain relief without parasitic induction heating.
What is the minimum order quantity and delivery lead time for TF-ACIH induction heating cable?
50 m per model specification on export reels, 3,000 V AC dielectric-tested and delivered in 7 to 45 working days.
TF-ACIH Bulk Reel (50 m+) & Coil-Cut Reference Schedule
TF-ACIH 1,000 V, 350–600 A, +450 °C & 50 m Bulk MOQ Summary
- 35–40 kW+ without chiller water: Eliminates freezing glycol chillers, leaking water hoses and pump skids on remote pipeline, offshore wind monopile and refinery turnaround weld jobs
- Anodized-Al or Ni-Cu HF Litz: Lightweight Ø 16 mm anodized-aluminum HF-stranded Litz (350 A / 0.53 kg/m) for easy manual pipe wrapping, or 25–95 mm² CuNi27 Litz up to 600 A
- +450 °C cable / +788 °C+ workpiece: Multi-layer mica-fiberglass thermal core withstands +450 °C cable contact over ceramic/silica preheat blankets on workpieces heated to +204 °C through +788 °C+
- 304 stainless braid strain relief: Exterior AISI 304 austenitic stainless-steel wire overbraid absorbs pulling tension and protects insulation against rough pipe bevels and weld slag
- Bulk 50 m+ reel supply (unterminated): Supplied strictly as bulk continuous or pre-cut coil lengths (for example 9.1 m, 15.2 m, 24.4 m cuts totaling >= 50 m MOQ; twist-lock plugs not included)
| Parameter | Value |
|---|---|
| Rated voltage | 1000 V AC maximum high-frequency inverter output (5 kHz to 30 kHz) with 3000 V AC routine dielectric test |
| Current and power capacity | 250 A to 600 A continuous air-cooled HF duty supporting 35 kW to 50 kW 100% duty-cycle induction power sources |
| Temperature limits | +450 C maximum continuous cable surface temperature; supports workpiece temperatures up to +788 C to +1200 C over thermal insulation blankets |
| Conductor and armour options | Anodized aluminum HF Litz (TF-ACIH-AL16, 0.53 kg/m) or 27% nickel-clad copper HF Litz (TF-ACIH-CU25 to CU95) with 304 stainless braid (-SS) or silicone-glass (-SG) |
| Bulk supply MOQ and lead time | 50 m minimum order quantity supplied as bulk continuous reel or pre-cut coil lengths (unterminated, plugs not included) in 7 to 45 working days |
| Standard field coil cut lengths | Common contractor coil cuts of 9.1 m (30 ft), 15.0 m, 15.2 m (50 ft), 24.4 m (80 ft) and 30.5 m (100 ft) cut from 50 m to 200 m drums |
| Minimum pipe-wrap diameter | Minimum wrapping mandrel diameter 150 to 200 mm (6 to 8 in pipe OD) depending on cross-section |
TF-ACIH (Anodized-Al & CuNi27 HF Litz) Bulk Reel Schedule
| Model & Conductor Build | Outer Protection | Nom. OD (mm) | Max. HF Current (5–25 kHz) | System Power Class | Max. Cable Temp | Approx. Weight (kg/km) | Bulk Reel MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| TF-ACIH-AL16-SS (Anodized Al HF Litz) | 304 Stainless Steel Braid | 16.0 | 350 A | 35–40 kW Air-Cooled | +450 °C | 530 | 50 m reel | Request this size |
| TF-ACIH-AL16-SG (Anodized Al HF Litz) | Silicone-Glass Braid (Blanket) | 15.5 | 350 A | 35–40 kW Blanket Core | +350 °C | 440 | 50 m reel | Request this size |
| TF-ACIH-CU25-SS (25 mm² CuNi27 Litz) | 304 Stainless Steel Braid | 13.8 | 260 A | 20–30 kW Air-Cooled | +450 °C | 395 | 50 m reel | Request this size |
| TF-ACIH-CU35-SS (35 mm² CuNi27 Litz) | 304 Stainless Steel Braid | 15.8 | 330 A | 30–35 kW Air-Cooled | +450 °C | 520 | 50 m reel | Request this size |
| TF-ACIH-CU50-SS (50 mm² CuNi27 Litz) | 304 Stainless Steel Braid | 18.2 | 410 A | 35–45 kW Air-Cooled | +450 °C | 715 | 50 m reel | Request this size |
| TF-ACIH-CU50-SG (50 mm² CuNi27 Litz) | Silicone-Glass Braid (Blanket) | 17.6 | 410 A | 35–45 kW Blanket Core | +350 °C | 630 | 50 m reel | Request this size |
| TF-ACIH-CU70-SS (70 mm² CuNi27 Litz) | 304 Stainless Steel Braid | 21.0 | 500 A | 45–50 kW Air-Cooled | +450 °C | 965 | 50 m reel | Request this size |
| TF-ACIH-CU95-SS (95 mm² CuNi27 Litz) | 304 Stainless Steel Braid | 24.2 | 600 A | 50–60 kW Heavy PWHT | +450 °C | 1,280 | 50 m reel | Request this size |
TF-ACIH Field-Coil Cut Planning (9.1 m, 15.2 m & 24.4 m Cuts)
| Bulk Cut Reference | Cut Coil Length (m / ft) | Typical Pipe Diameter Span | Coil Weight in AL16-SS | Min. Pieces to Meet 50 m MOQ | Supply Condition | Next step |
|---|---|---|---|---|---|---|
| TF-ACIH-CUT-9M (30 ft Cut) | 9.1 m (30 ft) | DN 150–400 (6"–16" Pipe) | 4.8 kg / coil | 6 cuts (54.6 m) or 50 m reel | Unterminated bulk cable | Request this size |
| TF-ACIH-CUT-15M (15 m Cut) | 15.0 m (49.2 ft) | DN 300–750 (12"–30" Pipe) | 8.0 kg / coil | 4 cuts (60.0 m) or 50 m reel | Unterminated bulk cable | Request this size |
| TF-ACIH-CUT-15P2M (50 ft Cut) | 15.2 m (50 ft) | DN 300–800 (12"–32" Pipe) | 8.1 kg / coil | 4 cuts (60.8 m) or 50 m reel | Unterminated bulk cable | Request this size |
| TF-ACIH-CUT-24P4M (80 ft Cut) | 24.4 m (80 ft) | DN 600–1,500+ (24"–60" Vessel) | 12.9 kg / coil | 3 cuts (73.2 m) or 50 m reel | Unterminated bulk cable | Request this size |
| TF-ACIH-CUT-30P5M (100 ft Cut) | 30.5 m (100 ft) | Large Monopiles & Steam Drums | 16.2 kg / coil | 2 cuts (61.0 m) or 100 m reel | Unterminated bulk cable | Request this size |
Mandatory thermal blanket notice: TF-ACIH is rated +450 °C at the cable surface; when heating steel workpieces to +650 °C (PWHT) or up to +1,200 °C, always place a 25–50 mm ceramic/silica thermal insulation blanket between the glowing steel and the induction cable so cable surface temperature remains <= +450 °C.
Supply scope: supplied strictly as bulk continuous reel length or factory-cut unterminated lengths (MOQ 50 m total per model); inverter-brand-specific twist-lock plugs and quick couplings are fitted by the customer or OEM integrator.
ASCII part references for BOM and ERP entry: TF-ACIH-AL16-SS, TF-ACIH-AL16-SG, TF-ACIH-CU35-SS, TF-ACIH-CU50-SS, TF-ACIH-CU50-SG, TF-ACIH-CU70-SS, TF-ACIH-CU95-SS.
TF-ACIH Reference Standards (IEC 60519-3 & Weld PWHT Practice)
| Standard or specification | Application |
|---|---|
| IEC 60519-3 Safety in Induction & Electroheating Installations | 1,000 V AC primary dielectric barrier, non-magnetic austenitic 304 stainless armouring and thermal endurance criteria. |
| AWS D10.10 / ASME B31.3 Local Weld Preheat & PWHT Practice | Flexible wrap-coil geometry for uniform circumferential induction heating of alloy-steel piping and pressure vessels. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and 3,000 V AC routine dielectric inspection
IEC 60519-3 — Safety in installations for induction and dielectric heating
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Shielded High Frequency Litz Power Cable, 1 kV AC
A related cable option for a different application or duty profile.
View productTF-HC10K, TF-HC2K & TF-WCCX 2 kHz / 10 kHz Hollow-Core Litz & Two-Conductor Coaxial Water-Cooled Cable
A related cable option for a different application or duty profile.
View productFEP, PFA & PTFE Thermocouple Wire & Screened Multi-Pair Cable (K, J, T, E, N)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.