High Temperature Cables TEBAOFLEX

TF-HC10K, TF-HC2K & TF-WCCX 2 kHz / 10 kHz Hollow-Core Litz & Two-Conductor Coaxial Water-Cooled Cable

TF-HC2K (up to 2 kHz), TF-HC10K (up to 10 kHz double-enameled Litz hollow-core, 70–1,015 mm²) and TF-WCCX (300–6,000 MCM two-conductor low-reactance coaxial) are medium-frequency water-cooled induction power cables (TF-HC10K-WCCX). Engineered to minimize skin effect and inductive voltage drop (I × Z × L) in 500 Hz to 10 kHz induction forging, hardening, brazing and melting circuits.

Product information
SKU
TF-HC10K-WCCX
Brand
TEBAOFLEX
Product overview

TF-HC2K, TF-HC10K and TF-WCCX medium-frequency water-cooled induction cables solve the two electromagnetic bottlenecks that cripple ordinary stranded furnace leads above 500 Hz: radial skin-effect current crowding (which spikes AC resistance R_AC) and loop inductive reactance X_L = 2πfL (which starves the induction coil of terminal voltage).

In TF-HC2K (300–1,000 mm², 50–2,000 Hz) and TF-HC10K (70–1,015 mm², 50–10,000 Hz), thin annular conductor layers wrap around an unobstructed central coolant bore—maximizing wetted surface area while eliminating the dead electromagnetic center of solid ropes; above 2 kHz, TF-HC10K uses double-enameled copper Litz wires silver/tin-soldered into E-copper heads so every strand carries equal current. Where go-and-return bus spacing causes excessive kVA voltage drop, TF-WCCX (300–6,000 MCM) nests both polarities coaxially inside one 80 PSI (5.5 bar) coolant hose to cancel external magnetic flux.

Specify TF-HC2K (flat palm or Ø 28–70 mm pipe-union head) for 250 Hz to 2 kHz induction melters and bus-pipe transitions; specify TF-HC10K for 2 kHz to 10 kHz billet heaters, bar forges and shaft-hardening machines; or specify single-hose TF-WCCX coaxial leads when routing long low-reactance feeds from inverter cabinets to workhead transformers. MOQ 2 pieces (TF-HC2K / TF-HC10K) or 1 coaxial assembly set (TF-WCCX), 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

TF-HC10K, TF-HC2K & TF-WCCX Hollow & Coaxial Design

Engineered for medium-frequency skin-depth optimization, zero-magnetic-kick coaxial cancellation and 10 bar hydro-tested flame-retardant coolant containment.

Clean 2D circular engineering cross-section of TF-HC10K hollow-core medium-frequency water-cooled cable showing outer black rubber hose, concentric ring of 12 amber-enameled copper Litz bundles and wide open central coolant bore
Annular hollow-core Litz cross-section: 12 insulated copper Litz sub-bundles around a wide central water bore eliminating high-frequency skin-effect dead copper.
TF-HC10K, TF-HC2K & TF-WCCX 2 kHz / 10 kHz Hollow-Core Litz & Two-Conductor Coaxial Water-Cooled Cable construction
ComponentMaterial and construction
1. Annular Hollow-Core or Concentric Dual-Polarity Coaxial ConductorsBare/tinned copper tubular rope on TF-HC2K (<= 2 kHz); double-enamel-insulated Litz copper strands on TF-HC10K (<= 10 kHz); or concentric inner/outer go-and-return copper ropes separated by a high-dielectric elastomer tube on TF-WCCX.
2. High-Volume Central Coolant Bore & Annular Water PassagesOpen central channel delivers turbulent coolant directly behind the current-carrying skin layer (rated 6 bar working / 10 bar test on TF-HC; 80 PSI / 5.5 bar on TF-WCCX).
3. Flat Palms, Ø 28–70 mm Pipe Unions or Split Coaxial Bus HeadsSolderless crimped Cu-ETP heads on TF-HC2K, dip-brazed/soldered enameled-Litz heads on TF-HC10K, hex/octagon/groove-nut pipe couplings (Ø 28–70 mm), or CNC-milled dual-polarity coaxial bus flags.
4. Multi-Layer Self-Extinguishing Electrically Insulated Coolant HoseAbrasion-, heat- and ozone-resistant synthetic rubber outer hose clamped with non-magnetic AISI 304/316 stainless rings to prevent eddy-current ring heating.

TF-HC10K, TF-HC2K & TF-WCCX Series Breakdown

  • TF-HC2K-<mm²>: Water-cooled hollow-core bare/tinned copper cable for 50 Hz to 2,000 Hz (300–1,000 mm², crimped flat head)
  • TF-HC2K-P: Hollow-core cable fitted on one or both ends with Ø 28–70 mm watertight current-carrying copper pipe unions
  • TF-HC10K-<mm²>: Double-enamel-insulated copper Litz hollow-core cable for 2,000 Hz to 10,000 Hz (70–1,015 mm², soldered head)
  • TF-WCCX-<MCM>: Two-conductor concentric coaxial low-reactance water-cooled cable (300–6,000 MCM, 60 Hz to 3,000 Hz)
  • Pair-Foot (Z / R_AC): Combined impedance and AC resistance of 1 ft outward ('go') plus 1 ft concentric 'return' conductor
Applications

TF-HC10K & TF-WCCX Forging, Hardening & Melting Duty

Built for 500 Hz to 10,000 Hz solid-state induction heating, forging, heat-treating, brazing, crystal-growing and foundry power transmission.

Pair of heavy black TF-HC10K hollow-core water-cooled induction cables with hexagonal copper pipe-connection heads feeding a multi-turn copper induction coil heating a glowing orange steel shaft
Medium-frequency induction billet-forging and shaft-hardening coil powered through low-loss TF-HC10K hollow-core water-cooled leads.
  • Medium-frequency (1–10 kHz) steel billet, bar-end andslab induction forging heaters and seamless-pipe seam-annealing coils.
  • Automotive crankshaft, camshaft, axle, gear and bearing-raceway CNC induction scan-hardening and tempering stations.
  • High-power induction melting & holding furnaces requiring watertight Ø 28–70 mm flexible transitions between rigid water-cooled copper bus-pipes and coils.
  • Longinverter-to-heat-station runs where TF-WCCX two-conductor coaxial leads eliminate magnetic kick against steel enclosures and cut reactive kVA drop.

TF-HC10K (10 kHz) vs TF-HC2K vs TF-WCCX Coaxial vs Dry Litz

TF-HC10K (10 kHz Hollow Litz) vs TF-HC2K (2 kHz) vs TF-WCCX (Coaxial) vs Dry 1 kV HF Litz Cable
Induction Cable TypeMax Frequency & CoolingPrimary Electromagnetic AdvantageIdeal Induction System
TF-HC10K Hollow-Core Litz (this page)Up to 10,000 Hz; 6 bar waterDouble-enameled strands eliminate skin effect up to 10 kHzMF billet forging, bar heating & CNC induction hardening coils
TF-HC2K Hollow-Core (this page)Up to 2,000 Hz; 6 bar water500-ton solderless crimped flat heads or Ø 28–70 mm pipe unions250 Hz–2 kHz melting furnaces & water-cooled copper pipe joints
TF-WCCX Coaxial (this page)60 Hz–3,000 Hz; 5.5 bar waterGo + return in one hose cancels stray flux & cuts voltage drop I×Z×LLong low-reactance feeds from inverter cabinet to workhead
Dry Shielded 1 kV HF Litz10 kHz–100 kHz; ambient airZero cooling water plumbing; flexible tinned-Cu EMC braid<= 400 A air-cooled induction preheat, EV wireless charging & inverters

Above 10 kHz up to 400 kHz (tube welders and RF crystal pullers), specify finer 0.05–0.10 mm strand gauge on your RFQ so strand diameter stays smaller than copper skin depth δ.

TF-HC10K & TF-WCCX Medium-Frequency Cable RFQ Checklist

  • Series selection: TF-HC2K (<= 2 kHz), TF-HC10K (2–10 kHz enameled Litz) or TF-WCCX (two-conductor coaxial).
  • Operating current (A), inverter frequency (Hz / kHz), coil voltage (V) and duty cycle (%).
  • Overall center-to-center assembly length and terminal interface (flat palm dimensions, Ø 28–70 mm copper pipe OD, or coaxial positive-to-negative busbar ridge spacing).
  • Available cooling water inlet pressure (bar / PSI), inlet temperature (°C) and flow capacity (L/min or GPM).
  • Quantity required (MOQ 2 pieces / 1 pair on TF-HC, or 1–2 assemblies on TF-WCCX; 7 to 45 working days).

Related selection resources

TF-HC10K Hollow-Core & TF-WCCX Coaxial Water-Cooled FAQ

Why does TF-HC10K use soldered enameled wires while TF-HC2K uses cold-crimped bare copper?

Above 2,000 Hz, bare touching copper strands allow eddy currents to jump strand-to-strand, forcing all current into the outer skin; TF-HC10K insulates every strand with double enamel film and thermally strips/solders the bundle into the copper head so every wire shares 10 kHz current.

When should I specify a TF-WCCX two-conductor coaxial water-cooled cable instead of two single cables?

Specify TF-WCCX whenever go-and-return leads run more than 2–3 m or pass near steel structural frames: concentric polarity cancels external magnetic fields (preventing steel cabinet induction heating) and cuts loop impedance Z by 50–70 % compared with separated single leads.

Can TF-HC10K or TF-HC2K connect directly onto rigid water-cooled copper bus-pipes?

Yes — order TF-HC2K-P (or custom TF-HC10K pipe heads) with one-side or both-side watertight current-carrying pipe couplings sized for standard 28 mm through 70 mm OD copper tubes (hexagonal standard, octagon or groove-nut).

Why are non-magnetic stainless-steel hose bands mandatory on TF-HC10K and TF-WCCX cables?

Carbon-steel clamps act like shorted transformer turns inside a 2–10 kHz magnetic field, glowing red-hot from hysteresis and eddy-current losses and burning through the rubber coolant hose; TEBAOFLEX uses strictly non-magnetic AISI 304/316 bands.

What is the minimum order quantity and delivery time for TF-HC10K, TF-HC2K and TF-WCCX?

2 pieces (1 matched pair) for single-pole TF-HC2K / TF-HC10K leads or 1 complete dual-polarity assembly for TF-WCCX coaxial cables, hydro-tested at 10 bar and delivered in 7 to 45 working days.

Specifications

TF-HC10K / TF-HC2K (mm²) & TF-WCCX (MCM) kHz Schedule

TF-HC10K & TF-WCCX Frequency, Pressure & MOQ Summary

  • 10 kHz double-enameled hollow Litz: TF-HC10K winds individually double-enamel-insulated copper strands around a wide central water bore, sustaining up to 3,700 A at 10,000 Hz
  • 2 kHz pressed & pipe-head builds: TF-HC2K (300–1,000 mm²) offers 500-ton crimped flat copper heads or Ø 28–70 mm hexagonal/octagon pipe-union fittings for water-cooled bus-tubes
  • Two-conductor coaxial low-Z design: TF-WCCX (300–6,000 MCM) places go and return conductors concentrically inside one hose, slashing inductive reactance Z to 16–27 μΩ/pair-ft at 60 Hz
  • Multi-frequency kA rating tables: Explicit current schedules at 50/60 Hz, 1 kHz, 2 kHz, 3 kHz, 4 kHz and 10 kHz eliminate guesswork when matching solid-state IGBT/SCR inverters
  • 2 pieces / 1 set custom supply: Delivered hydro-tested at 10 bar from a 2 pieces (1 pair) or 1 coaxial assembly set minimum order in 7 to 45 working days
TF-HC10K, TF-HC2K & TF-WCCX 2 kHz / 10 kHz Hollow-Core Litz & Two-Conductor Coaxial Water-Cooled Cable technical data
ParameterValue
Rated voltageUp to 1000 V to 2000 V AC medium-frequency inverter output with 5 kV dielectric outer coolant hose
Frequency and section rangeTF-HC2K: 300 to 1000 mm2 (up to 2 kHz); TF-HC10K: 70 to 1015 mm2 enameled Litz (up to 10 kHz); TF-WCCX: 300 to 6000 MCM coaxial (60 Hz to 3 kHz)
Terminal and pipe couplingsFlat copper contact heads (G 1/4 in to G 3/8 in ports), watertight pipe connections for 28 to 70 mm OD copper pipes, or dual-lug coaxial terminals
Coolant pressure and temperature5.5 to 6.0 bar max working pressure (10 bar factory hydro-test); max water inlet +32 C (+90 F) and max outlet +65 C (+150 F)
Minimum order and lead time2 pieces (1 pair) on TF-HC2K and TF-HC10K or 1 set on TF-WCCX coaxial leads, delivered in 7 to 45 working days
Eddy-current protectionStrictly non-magnetic AISI 304/316 stainless-steel hose bands prevent induction stray-field heating at terminal necks
Minimum bend diameterApproximately 8x hose outer diameter on coaxial TF-WCCX (21 in to 60 in) and 6x to 8x OD on hollow-core TF-HC leads

TF-HC10K (10 kHz Litz) & TF-HC2K (2 kHz) Hollow-Core Schedule

TF-HC10K (Double-Enameled Litz up to 10 kHz) & TF-HC2K (Bare/Tinned Hollow-Core up to 2 kHz) — Multi-Frequency Current Schedule
Model & Cross-SectionConductor BuildCurrent at 50 Hz (A)Current at 1 kHz (A)Current at 2 kHz (A)Current at 4 / 10 kHz (A)Palm Width × PortAssembly MOQNext step
TF-HC10K-70 (70 mm²)Double-Enameled Litz950920900800 / 70025 mm × G 1/4"2 pcs (1 pair)Request this size
TF-HC10K-140 (140 mm²)Double-Enameled Litz1,9001,7001,6001,500 / 1,35035 mm × G 3/8"2 pcs (1 pair)Request this size
TF-HC10K-210 (210 mm²)Double-Enameled Litz2,7502,4002,2502,100 / 1,75042 mm × G 3/8"2 pcs (1 pair)Request this size
TF-HC10K-315 (315 mm²)Double-Enameled Litz4,6004,1003,8503,450 / 2,20050 mm × G 3/8"2 pcs (1 pair)Request this size
TF-HC10K-420 (420 mm²)Double-Enameled Litz5,6005,0004,8504,000 / 2,50055 mm × G 3/8"2 pcs (1 pair)Request this size
TF-HC10K-525 (525 mm²)Double-Enameled Litz6,7006,0005,7004,800 / 3,00060 mm × G 3/8"2 pcs (1 pair)Request this size
TF-HC10K-700 (700 mm²)Double-Enameled Litz7,5006,3005,9005,300 / 3,40060 mm × G 3/8"2 pcs (1 pair)Request this size
TF-HC10K-815 (815 mm²)Double-Enameled Litz8,5007,2006,4005,700 / 3,70070 mm × G 3/8"2 pcs (1 pair)Request this size
TF-HC10K / HC2K-300 (300 mm²)Bare/Tinned Hollow3,7003,1002,900— (<=2 kHz)42 mm or Pipe Ø28–422 pcs (1 pair)Request this size
TF-HC10K / HC2K-500 (500 mm²)Bare/Tinned Hollow5,5004,8004,600— (<=2 kHz)55 mm or Pipe Ø40–502 pcs (1 pair)Request this size
TF-HC10K / HC2K-800 (800 mm²)Bare/Tinned Hollow8,0006,2005,900— (<=2 kHz)70 mm or Pipe Ø50–702 pcs (1 pair)Request this size
TF-HC10K / HC2K-1000 (1,000 mm²)Bare/Tinned Hollow10,0006,8006,000— (<=2 kHz)70 mm or Pipe Ø60–702 pcs (1 pair)Request this size

TF-WCCX (300–6,000 MCM) Two-Conductor Coaxial Low-Z Schedule

TF-WCCX Two-Conductor Coaxial Low-Reactance Water-Cooled Cable (300 MCM to 6,000 MCM) — 60 Hz & 3,000 Hz Impedance Schedule
Model & MCM SizeHose OD / Min. Bend Ø (in)60 Hz Current / Z (A / μΩ·ft⁻¹)3,000 Hz Current / Z (A / μΩ·ft⁻¹)R_DC (μΩ / pair-ft)Dry / Wet Wt (lbs/ft)Assembly MOQNext step
TF-WCCX-300 (300 MCM)2.62 / 21"1,400 A / 76600 A / 1,035764.0 / 6.01–2 pcsRequest this size
TF-WCCX-1000 (1,000 MCM)3.62 / 29"4,700 A / 271,175 A / 7262210.2 / 13.01–2 pcsRequest this size
TF-WCCX-1500 (1,500 MCM)5.00 / 40"7,000 A / 231,290 A / 8281415.0 / 19.01–2 pcsRequest this size
TF-WCCX-2000 (2,000 MCM)5.50 / 44"9,400 A / 211,590 A / 8291020.0 / 24.01–2 pcsRequest this size
TF-WCCX-2500 (2,500 MCM)5.50 / 44"11,700 A / 192,020 A / 785923.0 / 26.01–2 pcsRequest this size
TF-WCCX-3000 (3,000 MCM)6.00 / 48"14,100 A / 182,540 A / 797727.0 / 31.01–2 pcsRequest this size
TF-WCCX-3500 (3,500 MCM)6.00 / 48"16,500 A / 172,750 A / 765630.0 / 33.01–2 pcsRequest this size
TF-WCCX-4000 (4,000 MCM)6.00 / 48"18,800 A / 162,800 A / 725533.0 / 36.01–2 pcsRequest this size
TF-WCCX-6000 (6,000 MCM)7.50 / 60"28,300 A / 184,350 A / 830449.0 / 52.01–2 pcsRequest this size

Coaxial sizing equations (per pair-foot of go + return conductor): Power Loss (W) = I² × R_AC × L; Voltage Drop (V) = I × Z × L; Min Water Flow (GPM) = I² × R_AC × L / 4,410 (for a 30 °F / 16.7 °C water rise; never design below 2.0 GPM). Final bus-spacing dimensions are confirmed on the quotation drawing.

Pipe-connection hollow-core builds (TF-HC2K-P) fit standard current-carrying copper pipe outer diameters of 28, 30, 35, 40, 42, 48, 50, 60 and 70 mm with hexagonal, octagon or groove-nut watertight unions.

ASCII part references for BOM and ERP entry: TF-HC10K-140, TF-HC10K-315, TF-HC10K-525, TF-HC10K-815, TF-HC2K-500, TF-HC2K-800, TF-HC2K-1000, TF-WCCX-1000, TF-WCCX-2000, TF-WCCX-3000, TF-WCCX-4000, TF-WCCX-6000.

Standards

TF-HC10K & TF-WCCX Reference Standards (IEC 60519-3 & MW 1000)

TF-HC10K, TF-HC2K & TF-WCCX 2 kHz / 10 kHz Hollow-Core Litz & Two-Conductor Coaxial Water-Cooled Cable standards and test references
Standard or specificationApplication
IEC 60317 & NEMA MW 1000 Double-Enamel Magnet-Wire InsulationThermal-class polyamide-imide / polyurethane-nylon double-film strand insulation on TF-HC10K 10 kHz hollow-core Litz bundles.
DIN EN 13601 & IEC 60519-3 Induction Heating Safety ReferenceHigh-conductivity ETP/OFHC copper head machining, non-magnetic stainless clamping and 10 bar hydro-test verification.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and 10 bar hydro-test inspection

IEC 60519-3 — Safety in installations for electroheating and electromagnetic processing (induction installations)

NEMA MW 1000 — Magnet Wire Enamel Film Insulation Standards

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.