TF-HC10K, TF-HC2K & TF-WCCX 2 kHz / 10 kHz Hollow-Core Litz & Two-Conductor Coaxial Water-Cooled Cable
TF-HC2K (up to 2 kHz), TF-HC10K (up to 10 kHz double-enameled Litz hollow-core, 70–1,015 mm²) and TF-WCCX (300–6,000 MCM two-conductor low-reactance coaxial) are medium-frequency water-cooled induction power cables (TF-HC10K-WCCX). Engineered to minimize skin effect and inductive voltage drop (I × Z × L) in 500 Hz to 10 kHz induction forging, hardening, brazing and melting circuits.
TF-HC2K, TF-HC10K and TF-WCCX medium-frequency water-cooled induction cables solve the two electromagnetic bottlenecks that cripple ordinary stranded furnace leads above 500 Hz: radial skin-effect current crowding (which spikes AC resistance R_AC) and loop inductive reactance X_L = 2πfL (which starves the induction coil of terminal voltage).
In TF-HC2K (300–1,000 mm², 50–2,000 Hz) and TF-HC10K (70–1,015 mm², 50–10,000 Hz), thin annular conductor layers wrap around an unobstructed central coolant bore—maximizing wetted surface area while eliminating the dead electromagnetic center of solid ropes; above 2 kHz, TF-HC10K uses double-enameled copper Litz wires silver/tin-soldered into E-copper heads so every strand carries equal current. Where go-and-return bus spacing causes excessive kVA voltage drop, TF-WCCX (300–6,000 MCM) nests both polarities coaxially inside one 80 PSI (5.5 bar) coolant hose to cancel external magnetic flux.
Specify TF-HC2K (flat palm or Ø 28–70 mm pipe-union head) for 250 Hz to 2 kHz induction melters and bus-pipe transitions; specify TF-HC10K for 2 kHz to 10 kHz billet heaters, bar forges and shaft-hardening machines; or specify single-hose TF-WCCX coaxial leads when routing long low-reactance feeds from inverter cabinets to workhead transformers. MOQ 2 pieces (TF-HC2K / TF-HC10K) or 1 coaxial assembly set (TF-WCCX), 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
TF-HC10K, TF-HC2K & TF-WCCX Hollow & Coaxial Design
Engineered for medium-frequency skin-depth optimization, zero-magnetic-kick coaxial cancellation and 10 bar hydro-tested flame-retardant coolant containment.

| Component | Material and construction |
|---|---|
| 1. Annular Hollow-Core or Concentric Dual-Polarity Coaxial Conductors | Bare/tinned copper tubular rope on TF-HC2K (<= 2 kHz); double-enamel-insulated Litz copper strands on TF-HC10K (<= 10 kHz); or concentric inner/outer go-and-return copper ropes separated by a high-dielectric elastomer tube on TF-WCCX. |
| 2. High-Volume Central Coolant Bore & Annular Water Passages | Open central channel delivers turbulent coolant directly behind the current-carrying skin layer (rated 6 bar working / 10 bar test on TF-HC; 80 PSI / 5.5 bar on TF-WCCX). |
| 3. Flat Palms, Ø 28–70 mm Pipe Unions or Split Coaxial Bus Heads | Solderless crimped Cu-ETP heads on TF-HC2K, dip-brazed/soldered enameled-Litz heads on TF-HC10K, hex/octagon/groove-nut pipe couplings (Ø 28–70 mm), or CNC-milled dual-polarity coaxial bus flags. |
| 4. Multi-Layer Self-Extinguishing Electrically Insulated Coolant Hose | Abrasion-, heat- and ozone-resistant synthetic rubber outer hose clamped with non-magnetic AISI 304/316 stainless rings to prevent eddy-current ring heating. |
TF-HC10K, TF-HC2K & TF-WCCX Series Breakdown
- TF-HC2K-<mm²>: Water-cooled hollow-core bare/tinned copper cable for 50 Hz to 2,000 Hz (300–1,000 mm², crimped flat head)
- TF-HC2K-P: Hollow-core cable fitted on one or both ends with Ø 28–70 mm watertight current-carrying copper pipe unions
- TF-HC10K-<mm²>: Double-enamel-insulated copper Litz hollow-core cable for 2,000 Hz to 10,000 Hz (70–1,015 mm², soldered head)
- TF-WCCX-<MCM>: Two-conductor concentric coaxial low-reactance water-cooled cable (300–6,000 MCM, 60 Hz to 3,000 Hz)
- Pair-Foot (Z / R_AC): Combined impedance and AC resistance of 1 ft outward ('go') plus 1 ft concentric 'return' conductor
TF-HC10K & TF-WCCX Forging, Hardening & Melting Duty
Built for 500 Hz to 10,000 Hz solid-state induction heating, forging, heat-treating, brazing, crystal-growing and foundry power transmission.

- Medium-frequency (1–10 kHz) steel billet, bar-end andslab induction forging heaters and seamless-pipe seam-annealing coils.
- Automotive crankshaft, camshaft, axle, gear and bearing-raceway CNC induction scan-hardening and tempering stations.
- High-power induction melting & holding furnaces requiring watertight Ø 28–70 mm flexible transitions between rigid water-cooled copper bus-pipes and coils.
- Longinverter-to-heat-station runs where TF-WCCX two-conductor coaxial leads eliminate magnetic kick against steel enclosures and cut reactive kVA drop.
TF-HC10K (10 kHz) vs TF-HC2K vs TF-WCCX Coaxial vs Dry Litz
| Induction Cable Type | Max Frequency & Cooling | Primary Electromagnetic Advantage | Ideal Induction System |
|---|---|---|---|
| TF-HC10K Hollow-Core Litz (this page) | Up to 10,000 Hz; 6 bar water | Double-enameled strands eliminate skin effect up to 10 kHz | MF billet forging, bar heating & CNC induction hardening coils |
| TF-HC2K Hollow-Core (this page) | Up to 2,000 Hz; 6 bar water | 500-ton solderless crimped flat heads or Ø 28–70 mm pipe unions | 250 Hz–2 kHz melting furnaces & water-cooled copper pipe joints |
| TF-WCCX Coaxial (this page) | 60 Hz–3,000 Hz; 5.5 bar water | Go + return in one hose cancels stray flux & cuts voltage drop I×Z×L | Long low-reactance feeds from inverter cabinet to workhead |
| Dry Shielded 1 kV HF Litz | 10 kHz–100 kHz; ambient air | Zero cooling water plumbing; flexible tinned-Cu EMC braid | <= 400 A air-cooled induction preheat, EV wireless charging & inverters |
Above 10 kHz up to 400 kHz (tube welders and RF crystal pullers), specify finer 0.05–0.10 mm strand gauge on your RFQ so strand diameter stays smaller than copper skin depth δ.
TF-HC10K & TF-WCCX Medium-Frequency Cable RFQ Checklist
- Series selection: TF-HC2K (<= 2 kHz), TF-HC10K (2–10 kHz enameled Litz) or TF-WCCX (two-conductor coaxial).
- Operating current (A), inverter frequency (Hz / kHz), coil voltage (V) and duty cycle (%).
- Overall center-to-center assembly length and terminal interface (flat palm dimensions, Ø 28–70 mm copper pipe OD, or coaxial positive-to-negative busbar ridge spacing).
- Available cooling water inlet pressure (bar / PSI), inlet temperature (°C) and flow capacity (L/min or GPM).
- Quantity required (MOQ 2 pieces / 1 pair on TF-HC, or 1–2 assemblies on TF-WCCX; 7 to 45 working days).
Related selection resources
- Browse all Induction, Furnace Water-Cooled & High-Temp Cables
- Compare TF-IFL & TF-WCHC 50/60 Hz–3 kHz Foundry Power Leads
- Compare Dry Air-Cooled 1 kV Shielded High-Frequency Litz Cable
- Compare 6-Rope Alternate-Polarity Water-Cooled Kickless Welding Cable
- Compare Heavy 1,000–7,000 mm² Steelmaking EAF Water-Cooled Cable
- Engineering guide: Conductor stranding & high-frequency skin depth
TF-HC10K Hollow-Core & TF-WCCX Coaxial Water-Cooled FAQ
Why does TF-HC10K use soldered enameled wires while TF-HC2K uses cold-crimped bare copper?
Above 2,000 Hz, bare touching copper strands allow eddy currents to jump strand-to-strand, forcing all current into the outer skin; TF-HC10K insulates every strand with double enamel film and thermally strips/solders the bundle into the copper head so every wire shares 10 kHz current.
When should I specify a TF-WCCX two-conductor coaxial water-cooled cable instead of two single cables?
Specify TF-WCCX whenever go-and-return leads run more than 2–3 m or pass near steel structural frames: concentric polarity cancels external magnetic fields (preventing steel cabinet induction heating) and cuts loop impedance Z by 50–70 % compared with separated single leads.
Can TF-HC10K or TF-HC2K connect directly onto rigid water-cooled copper bus-pipes?
Yes — order TF-HC2K-P (or custom TF-HC10K pipe heads) with one-side or both-side watertight current-carrying pipe couplings sized for standard 28 mm through 70 mm OD copper tubes (hexagonal standard, octagon or groove-nut).
Why are non-magnetic stainless-steel hose bands mandatory on TF-HC10K and TF-WCCX cables?
Carbon-steel clamps act like shorted transformer turns inside a 2–10 kHz magnetic field, glowing red-hot from hysteresis and eddy-current losses and burning through the rubber coolant hose; TEBAOFLEX uses strictly non-magnetic AISI 304/316 bands.
What is the minimum order quantity and delivery time for TF-HC10K, TF-HC2K and TF-WCCX?
2 pieces (1 matched pair) for single-pole TF-HC2K / TF-HC10K leads or 1 complete dual-polarity assembly for TF-WCCX coaxial cables, hydro-tested at 10 bar and delivered in 7 to 45 working days.
TF-HC10K / TF-HC2K (mm²) & TF-WCCX (MCM) kHz Schedule
TF-HC10K & TF-WCCX Frequency, Pressure & MOQ Summary
- 10 kHz double-enameled hollow Litz: TF-HC10K winds individually double-enamel-insulated copper strands around a wide central water bore, sustaining up to 3,700 A at 10,000 Hz
- 2 kHz pressed & pipe-head builds: TF-HC2K (300–1,000 mm²) offers 500-ton crimped flat copper heads or Ø 28–70 mm hexagonal/octagon pipe-union fittings for water-cooled bus-tubes
- Two-conductor coaxial low-Z design: TF-WCCX (300–6,000 MCM) places go and return conductors concentrically inside one hose, slashing inductive reactance Z to 16–27 μΩ/pair-ft at 60 Hz
- Multi-frequency kA rating tables: Explicit current schedules at 50/60 Hz, 1 kHz, 2 kHz, 3 kHz, 4 kHz and 10 kHz eliminate guesswork when matching solid-state IGBT/SCR inverters
- 2 pieces / 1 set custom supply: Delivered hydro-tested at 10 bar from a 2 pieces (1 pair) or 1 coaxial assembly set minimum order in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | Up to 1000 V to 2000 V AC medium-frequency inverter output with 5 kV dielectric outer coolant hose |
| Frequency and section range | TF-HC2K: 300 to 1000 mm2 (up to 2 kHz); TF-HC10K: 70 to 1015 mm2 enameled Litz (up to 10 kHz); TF-WCCX: 300 to 6000 MCM coaxial (60 Hz to 3 kHz) |
| Terminal and pipe couplings | Flat copper contact heads (G 1/4 in to G 3/8 in ports), watertight pipe connections for 28 to 70 mm OD copper pipes, or dual-lug coaxial terminals |
| Coolant pressure and temperature | 5.5 to 6.0 bar max working pressure (10 bar factory hydro-test); max water inlet +32 C (+90 F) and max outlet +65 C (+150 F) |
| Minimum order and lead time | 2 pieces (1 pair) on TF-HC2K and TF-HC10K or 1 set on TF-WCCX coaxial leads, delivered in 7 to 45 working days |
| Eddy-current protection | Strictly non-magnetic AISI 304/316 stainless-steel hose bands prevent induction stray-field heating at terminal necks |
| Minimum bend diameter | Approximately 8x hose outer diameter on coaxial TF-WCCX (21 in to 60 in) and 6x to 8x OD on hollow-core TF-HC leads |
TF-HC10K (10 kHz Litz) & TF-HC2K (2 kHz) Hollow-Core Schedule
| Model & Cross-Section | Conductor Build | Current at 50 Hz (A) | Current at 1 kHz (A) | Current at 2 kHz (A) | Current at 4 / 10 kHz (A) | Palm Width × Port | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| TF-HC10K-70 (70 mm²) | Double-Enameled Litz | 950 | 920 | 900 | 800 / 700 | 25 mm × G 1/4" | 2 pcs (1 pair) | Request this size |
| TF-HC10K-140 (140 mm²) | Double-Enameled Litz | 1,900 | 1,700 | 1,600 | 1,500 / 1,350 | 35 mm × G 3/8" | 2 pcs (1 pair) | Request this size |
| TF-HC10K-210 (210 mm²) | Double-Enameled Litz | 2,750 | 2,400 | 2,250 | 2,100 / 1,750 | 42 mm × G 3/8" | 2 pcs (1 pair) | Request this size |
| TF-HC10K-315 (315 mm²) | Double-Enameled Litz | 4,600 | 4,100 | 3,850 | 3,450 / 2,200 | 50 mm × G 3/8" | 2 pcs (1 pair) | Request this size |
| TF-HC10K-420 (420 mm²) | Double-Enameled Litz | 5,600 | 5,000 | 4,850 | 4,000 / 2,500 | 55 mm × G 3/8" | 2 pcs (1 pair) | Request this size |
| TF-HC10K-525 (525 mm²) | Double-Enameled Litz | 6,700 | 6,000 | 5,700 | 4,800 / 3,000 | 60 mm × G 3/8" | 2 pcs (1 pair) | Request this size |
| TF-HC10K-700 (700 mm²) | Double-Enameled Litz | 7,500 | 6,300 | 5,900 | 5,300 / 3,400 | 60 mm × G 3/8" | 2 pcs (1 pair) | Request this size |
| TF-HC10K-815 (815 mm²) | Double-Enameled Litz | 8,500 | 7,200 | 6,400 | 5,700 / 3,700 | 70 mm × G 3/8" | 2 pcs (1 pair) | Request this size |
| TF-HC10K / HC2K-300 (300 mm²) | Bare/Tinned Hollow | 3,700 | 3,100 | 2,900 | — (<=2 kHz) | 42 mm or Pipe Ø28–42 | 2 pcs (1 pair) | Request this size |
| TF-HC10K / HC2K-500 (500 mm²) | Bare/Tinned Hollow | 5,500 | 4,800 | 4,600 | — (<=2 kHz) | 55 mm or Pipe Ø40–50 | 2 pcs (1 pair) | Request this size |
| TF-HC10K / HC2K-800 (800 mm²) | Bare/Tinned Hollow | 8,000 | 6,200 | 5,900 | — (<=2 kHz) | 70 mm or Pipe Ø50–70 | 2 pcs (1 pair) | Request this size |
| TF-HC10K / HC2K-1000 (1,000 mm²) | Bare/Tinned Hollow | 10,000 | 6,800 | 6,000 | — (<=2 kHz) | 70 mm or Pipe Ø60–70 | 2 pcs (1 pair) | Request this size |
TF-WCCX (300–6,000 MCM) Two-Conductor Coaxial Low-Z Schedule
| Model & MCM Size | Hose OD / Min. Bend Ø (in) | 60 Hz Current / Z (A / μΩ·ft⁻¹) | 3,000 Hz Current / Z (A / μΩ·ft⁻¹) | R_DC (μΩ / pair-ft) | Dry / Wet Wt (lbs/ft) | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|
| TF-WCCX-300 (300 MCM) | 2.62 / 21" | 1,400 A / 76 | 600 A / 1,035 | 76 | 4.0 / 6.0 | 1–2 pcs | Request this size |
| TF-WCCX-1000 (1,000 MCM) | 3.62 / 29" | 4,700 A / 27 | 1,175 A / 726 | 22 | 10.2 / 13.0 | 1–2 pcs | Request this size |
| TF-WCCX-1500 (1,500 MCM) | 5.00 / 40" | 7,000 A / 23 | 1,290 A / 828 | 14 | 15.0 / 19.0 | 1–2 pcs | Request this size |
| TF-WCCX-2000 (2,000 MCM) | 5.50 / 44" | 9,400 A / 21 | 1,590 A / 829 | 10 | 20.0 / 24.0 | 1–2 pcs | Request this size |
| TF-WCCX-2500 (2,500 MCM) | 5.50 / 44" | 11,700 A / 19 | 2,020 A / 785 | 9 | 23.0 / 26.0 | 1–2 pcs | Request this size |
| TF-WCCX-3000 (3,000 MCM) | 6.00 / 48" | 14,100 A / 18 | 2,540 A / 797 | 7 | 27.0 / 31.0 | 1–2 pcs | Request this size |
| TF-WCCX-3500 (3,500 MCM) | 6.00 / 48" | 16,500 A / 17 | 2,750 A / 765 | 6 | 30.0 / 33.0 | 1–2 pcs | Request this size |
| TF-WCCX-4000 (4,000 MCM) | 6.00 / 48" | 18,800 A / 16 | 2,800 A / 725 | 5 | 33.0 / 36.0 | 1–2 pcs | Request this size |
| TF-WCCX-6000 (6,000 MCM) | 7.50 / 60" | 28,300 A / 18 | 4,350 A / 830 | 4 | 49.0 / 52.0 | 1–2 pcs | Request this size |
Coaxial sizing equations (per pair-foot of go + return conductor): Power Loss (W) = I² × R_AC × L; Voltage Drop (V) = I × Z × L; Min Water Flow (GPM) = I² × R_AC × L / 4,410 (for a 30 °F / 16.7 °C water rise; never design below 2.0 GPM). Final bus-spacing dimensions are confirmed on the quotation drawing.
Pipe-connection hollow-core builds (TF-HC2K-P) fit standard current-carrying copper pipe outer diameters of 28, 30, 35, 40, 42, 48, 50, 60 and 70 mm with hexagonal, octagon or groove-nut watertight unions.
ASCII part references for BOM and ERP entry: TF-HC10K-140, TF-HC10K-315, TF-HC10K-525, TF-HC10K-815, TF-HC2K-500, TF-HC2K-800, TF-HC2K-1000, TF-WCCX-1000, TF-WCCX-2000, TF-WCCX-3000, TF-WCCX-4000, TF-WCCX-6000.
TF-HC10K & TF-WCCX Reference Standards (IEC 60519-3 & MW 1000)
| Standard or specification | Application |
|---|---|
| IEC 60317 & NEMA MW 1000 Double-Enamel Magnet-Wire Insulation | Thermal-class polyamide-imide / polyurethane-nylon double-film strand insulation on TF-HC10K 10 kHz hollow-core Litz bundles. |
| DIN EN 13601 & IEC 60519-3 Induction Heating Safety Reference | High-conductivity ETP/OFHC copper head machining, non-magnetic stainless clamping and 10 bar hydro-test verification. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and 10 bar hydro-test inspection
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-IFL & TF-WCHC Induction Melting & Vacuum Furnace Water-Cooled Power Lead Cable (70–2,500 MCM / 35–2,000 mm²)
A related cable option for a different application or duty profile.
View productShielded High Frequency Litz Power Cable, 1 kV AC
A related cable option for a different application or duty profile.
View productTF-KICKLESS Water-Cooled Kickless Welding Cable — 6-Rope Alternate-Polarity Spot-Welding Leads (300–800 MCM & 2×150–2×450 mm²)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.