Obtenir un devis
Câbles haute température

UL 3580 Silicone Motor Lead Wire, 150°C 1000V

UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.

  • tension: 1000 V AC
  • Température: 150°C
  • Isolation / revêtement : extruded silicone rubber
  • Sélection de la taille : 26 AWG–500 kcmil style range; table: 26–6 AWG
  • Certification : AWM certifié UL; UL 758
Informations sur le produit
Présentation du produit

UL 3580 wire selection

UL 3580 is a UL-certified silicone motor lead wire rated 150°C and 1000 V AC. It is intended for motor leads and internal appliance or electronic equipment wiring where the lead is protected from mechanical abuse.

The detailed size table covers 26–6 AWG. Nominal silicone thickness is 1.20 mm in the 26–10 AWG rows and 1.58 mm in the 8–6 AWG rows. Conductor stranding and finished diameter are listed with each model-size combination to help check motor terminal entries, connection boxes and protective sleeves. A separate insulation schedule explains the larger conductor groups within the style range.

For a motor connection, allow space for the finished wire rather than selecting the entry around the bare conductor size. The listed construction uses a bend radius of 10 times its finished diameter. Check the temperature near the winding exit and at the connection hardware, because the 150°C wire rating must be compatible with the rest of the assembly.

Consultez l’onglet Caractéristiques pour les tableaux de modèles et de calibres. Parcourez la gamme de câbles haute température for related constructions. Compare UL 3644 for a different 1 kV wall schedule and the gamme de fils de raccordement en silicone for lower-voltage options.

Construction

Construction

UL 1813 utilise le système conducteur et d'isolation suivant. Le schéma illustre la séquence des couches ; sélectionnez la construction du conducteur et le revêtement indiqués dans les spécifications de taille requises.

Illustrative UL 3580 single-core conductor and insulation construction cutaway
Illustrative UL 3580 construction; layer dimensions are not to scale.
UL 3580 construction layers
Composantdétail de construction
ConducteurSolid or stranded copper; dimensioned examples are stranded
IsolationCaoutchouc silicone extrudé
Applications

Applications

UL 3580 is used as motor lead wire and for internal appliance or electronic equipment wiring. Route and support the lead to prevent rubbing or mechanical damage at the winding exit and terminal enclosure.

Illustrative UL 3580 insulated lead routed inside industrial equipment
Illustrative UL 3580 equipment application; shown as an installation concept.

UL 3580 replacement selection

Pour une demande de remplacement, fournissez le marquage du fil existant et le schéma de raccordement de l’équipement afin de comparer le conducteur, l’isolation et la disposition des bornes.

Caractéristiques

Caractéristiques techniques

UL 3580 technical data
ParamètreSpécification
Style ULUL 3580
Tension assignée1000 V AC
Indice de température150°C
Isolation / revêtementextruded silicone rubber
Plage de calibres du conducteur26 AWG–500 kcmil style range; table: 26–6 AWG
Bending radius for listed construction10 × finished OD

Nominal dimensions follow the listed conductor constructions. Confirm the agreed finished-diameter drawing for tight-clearance assemblies.

UL 3580 size and dimension table
Modèle et calibre du conducteurBrins du conducteur (n°/mm)Nominal silicone wall (mm)Diamètre extérieur nominal / tolérance (mm)
UL 3580 6 AWG259/0.2541.587.89 ±0.10
UL 3580 8 AWG161/0.2541.586.88 ±0.10
UL 3580 10 AWG105/0.2541.205.41 ±0.10
UL 3580 12 AWG65/0.2541.204.77 ±0.10
UL 3580 14 AWG41/0.2541.204.28 ±0.10
UL 3580 16 AWG26/0.2541.203.90 ±0.10
UL 3580 18 AWG34/0.181.203.62 ±0.10
UL 3580 20 AWG21/0.181.203.36 ±0.10
UL 3580 22 AWG17/0.161.203.17 ±0.10
UL 3580 24 AWG11/0.161.203.02 ±0.10
UL 3580 26 AWG7/0.161.202.89 ±0.10

Style construction thicknesses are shown in mils; 1 mil = 0.0254 mm. Nominal finished dimensions are listed separately.

UL 3580 insulation thickness by conductor size
Model and conductor groupMinimum average silicone wall (mils)Minimum point wall (mils)
UL 3580 26–9 AWG4540
UL 3580 8–2 AWG6054
UL 3580 1–4/0 AWG8072
UL 3580 250–500 kcmil9586

Choix de la construction spécifiée

Specify UL 3580 with AWG or kcmil, stranding, required OD and connection temperature. For a size outside the dimension table, use the insulation schedule as a starting point and request the corresponding drawing.

Normes

Normes

TEBAOFLEX UL 3580 wire is UL-certified appliance wiring material.

UL 3580 certification and standards
ArticleExigence ou référence
CertificationAWM certifié UL
Désignation du styleUL 3580
Norme de constructionUL 758 — Matériaux de câblage pour appareils
Classement au feu du styleFlamme horizontale

Indiquez le style UL, le calibre du conducteur et les classes de tension et de température dans le cahier des charges. Joignez à la demande l’identification du produit et les documents de certification requis.

devis basé sur l'ingénierie

Demandez une recommandation et un devis pour un câble.

Veuillez nous indiquer les services requis, la longueur du câble, les contraintes mécaniques, l'environnement, le type de terminaison et la quantité. Notre équipe examinera votre demande avant de vous établir un devis.

  • Veuillez inclure le nom du produit ou son SKU, ainsi que la longueur et la quantité de câble requises.
  • Joignez une fiche technique, un dessin ou une fiche de spécifications si disponible.

    En soumettant ce formulaire, vous acceptez que TEBAOFLEX utilise vos coordonnées et les fichiers fournis pour examiner votre demande et y répondre. Les fichiers servent à établir le devis et aux échanges techniques liés à votre demande. Consultez notre politique de confidentialité pour obtenir des informations à jour sur le traitement et la conservation des données.

    * Champs obligatoires. Veuillez inclure les principaux détails du câble ou de l'application pour examen.