MINING & TUNNELING CABLES TEBAOFLEX

TF-XLPEPUR-JUMBO 0.6/1 kV Halogen-Free XLPE/PUR Aramid-Reinforced Mining Reeling Cable

TF-XLPEPUR-JUMBO (0.6/1 kV XLPE/PUR HF reeling cable) is a halogen-free, aramid-strain-relieved power and pilot cable for underground drill jumbos, bolters and mobile reels across 3×25+3G6+2x1x1 to 3×150+3G25+2x1x1.5 mm², combining Class 5 copper, 90 °C XLPE insulation, three split earths, two pilots and dual-sheath dull-yellow PUR rated to 20 N/mm² and 8 × OD reeling bend.

Product information
SKU
TF-XLPEPUR-JUMBO
Brand
TEBAOFLEX
Product overview

TF-XLPEPUR-JUMBO (0.6/1 kV XLPE/PUR halogen-free mining reeling cable) supplies electro-hydraulic face drill jumbos, roof bolters, scaling rigs and mobile tunnel reels from 3×25+3G6+2x1x1 to 3×150+3G25+2x1x1.5 mm², pairing EN 60228 Class 5 bare copper, 90 °C XLPE insulation, a central aramid strain-relief core (20 N/mm²), two pilot cores and a dull-yellow PUR double sheath.

Conventional rubber reeling cables (such as NSHTOEU or Type G-GC) carry thicker elastomer walls that limit how many metres fit onto compact underground drill-jumbo hydraulic drums, while chlorinated rubber compounds release corrosive acid gas if overheated in confined headings. TF-XLPEPUR-JUMBO solves both constraints: cross-linked polyethylene (XLPE) phase insulation trims overall diameter to 23.0–24.5 mm on 3×25 mm² and 48.5–52.0 mm on 3×150 mm², a central aramid tension member absorbs up to 20 N/mm² dynamic drum pull, and inner plus outer polyurethane (PUR) sheaths resist sharp blasted-rock cut-through and hydraulic drill oil.

Specify TF-XLPEPUR-JUMBO where 0.6/1 kV (Umax 0.7/1.2 kV AC, 0.9/1.8 kV DC; 2.5 kV AC test to DIN VDE 0250-813) underground reeling equipment demands halogen-free EN 60754 polymers, high visibility in dark headings and ≥ 8 × OD reeling bend radii. For individual phase screening choose (N)TMH3S TPU reeling cable, and for heavy rubber LHD scooptram drums see NSHTOEU.

Explore the mining and tunneling cable range for related configurations.

Construction

TF-XLPEPUR-JUMBO 0.6/1 kV XLPE/PUR Reeling Construction

TF-XLPEPUR-JUMBO combines low-profile 90 °C XLPE dielectrics with a dual-layer cut-resistant PUR elastomer system.

Clean 2D engineering cross-section of TF-XLPEPUR-JUMBO 0.6/1 kV cable showing central aramid strain-relief core, three XLPE power cores, three green-yellow earths, two white and blue interstitial pilots, PUR inner sheath and yellow PUR outer sheath
TF-XLPEPUR-JUMBO cross-section: symmetrical 3+3+2P layout around the central aramid strain-relief element.
TF-XLPEPUR-JUMBO 0.6/1 kV Halogen-Free XLPE/PUR Aramid-Reinforced Mining Reeling Cable construction
ComponentMaterial and construction
1. Phase, earth & pilot conductorsMulti-stranded annealed bare copper, class 5 to EN / IEC 60228 (phases 25 to 150 mm², 3 split earths 6 to 25 mm², 2 pilots 1.0 or 1.5 mm²).
2. Core insulation & colour codeCross-linked polyethylene (XLPE) to IEC 60502-1: main cores black, brown, grey; 3 × green-yellow protective earths; 2 × pilots white and blue.
3. Central strain-relief & lay-upThree main cores and three split earth cores laid up around a central aramid-reinforced strain-relief core, with the two pilots in the outer interstices.
4. Inner sheathSpecial halogen-free polyurethane (PUR) bedding compound locking core geometry under multi-layer drum coiling.
5. Outer sheathAbrasion-, tear-, UV- and oil-resistant dull safety-yellow polyurethane (PUR) outer sheath, halogen-free to EN 60754.

TF-XLPEPUR-JUMBO Core & Material Code Breakdown

  • TF-XLPEPUR-JUMBO: TEBAOFLEX 0.6/1 kV halogen-free XLPE/PUR aramid-reinforced mining reeling cable
  • 3x25 to 3x150: Three EN 60228 Class 5 bare copper XLPE-insulated phase cores (black, brown, grey)
  • +3G6 to +3G25: Three symmetrical green-yellow XLPE-insulated protective-earth conductors
  • +2x1x1 or +2x1x1.5: Two interstitial pilot/control cores (white and blue) for interlock and monitoring
  • Aramid + Dual PUR: Central aramid tension carrier (20 N/mm²) inside inner and dull-yellow outer PUR sheaths
Applications

TF-XLPEPUR-JUMBO Drill Jumbo and Tunnel Reeling Applications

TF-XLPEPUR-JUMBO is built for frequent reeling, unreeling and rock-floor dragging on low-voltage underground and surface mobile machinery.

Underground hard-rock drill jumbo in a mine tunnel drift paying out a yellow TF-XLPEPUR-JUMBO PUR reeling cable from its rear hydraulic cable drum
Typical duty: compact 0.6/1 kV halogen-free reeling feed on an underground electro-hydraulic face drill jumbo.
  • Underground hard-rock face drill jumbos, production long-hole drills, rock bolters and shotcrete robotic sprayers.
  • Tunneling gantry reels, mobile shaft-sinking winches, extendable belt-conveyor take-up loops and portable mine hoists.
  • Dry, humid and flooded headings plus outdoor quarries (-30 °C to +80 °C flexing, -40 °C to +80 °C fixed) exposed to drill oils and emulsions.

TF-XLPEPUR-JUMBO vs (N)TMH3S, NSHTOEU and Type G-GC

TF-XLPEPUR-JUMBO (XLPE/PUR HF) vs (N)TMH3S vs NSHTOEU vs Type G-GC
Cable familyInsulation / sheathHalogen-freePrimary underground duty
TF-XLPEPUR-JUMBO (this page)XLPE / dual PUR + central aramidYes (EN 60754)Compact 0.6/1 kV drill jumbo & bolter reels with 2 pilots
(N)TMH3S 0.6/1 kVEPR or HEPR / TPU outer sheathProject buildHeavy reeling with elastomeric core cushion
NSHTOEU LHD reeling3GI3 EPR / 5GM3 polychloroprene rubberNoHigh-temperature rubber drum reeling on LHD loaders
Type G-GC 2000 VEPR / heavy CPE or NBR-PVCNoNorth American ICEA 2 kV portable jumbos with GC check

Selection rule: choose TF-XLPEPUR-JUMBO whenever drum flange capacity requires a slimmer OD than EPR/rubber cables or tunnel ventilation rules require halogen-free PUR.

TF-XLPEPUR-JUMBO Mining Reeling Cable RFQ Checklist

  • Cross-section from 3x25+3G6+2x1x1 up to 3x150+3G25+2x1x1.5 mm² and drill jumbo motor kW rating.
  • Cable reel drum barrel diameter (check ≥ 8 × max OD) and maximum hydraulic reel tension (≤ 20 N/mm²).
  • Pilot circuit voltage and diode/relay termination scheme on the 2 × 1.0 or 2 × 1.5 mm² white/blue cores.
  • Heading ambient temperature, mine water pH, and drill-oil exposure.
  • Required drum cut lengths and delivery schedule (MOQ 50 m; 7 to 45 working days).

Related selection resources

TF-XLPEPUR-JUMBO 0.6/1 kV PUR Mining Cable FAQ

Why does TF-XLPEPUR-JUMBO pair XLPE insulation with a dual PUR sheath on drill jumbo reels?

90 °C XLPE cuts overall diameter by 12 to 18 % compared with EPR rubber while dual-sheath PUR provides superior rock cut-through resistance, oil resistance and EN 60754 halogen-free safety.

What maximum tensile load and minimum bending radius apply to TF-XLPEPUR-JUMBO?

20 N/mm² maximum conductor tensile stress (1,500 N on 3x25 mm² up to 9,000 N on 3x150 mm²) and a minimum bending radius of 8 × OD in reeling service (6 × OD fixed).

How are the earths and pilot cores arranged inside TF-XLPEPUR-JUMBO?

3 green-yellow protective-earth cores and 3 phase cores (black, brown, grey) are laid around a central aramid strain-relief member, with 2 pilot cores (white and blue) in the outer interstices.

What voltages is TF-XLPEPUR-JUMBO rated and tested for?

0.6/1 kV rated voltage (permissible operating maximum 0.7/1.2 kV AC and 0.9/1.8 kV DC), factory tested at 2.5 kV AC with reference to DIN VDE 0250-813.

What are the MOQ and manufacturing lead time for TF-XLPEPUR-JUMBO?

50 m minimum order quantity with a production lead time of 7 to 45 working days.

Specifications

TF-XLPEPUR-JUMBO Size, Bend Radius and Tensile Schedule

TF-XLPEPUR-JUMBO Key Electrical and Mechanical Ratings

  • Central aramid carrier: Three main XLPE phases and three split green-yellow earths laid around an aramid strain-relief element for 20 N/mm² pull
  • Slim XLPE/PUR diameter: IEC 60502-1 XLPE wall plus dual-extruded PUR inner and dull-yellow outer sheaths reduce reel diameter vs EPR rubber
  • Integrated 2x1x1.5 pilots: White and blue control/pilot cores in the outer interstices support earth-continuity and interlock monitoring
  • Halogen-free & oil-proof: Tested to EN 60754 halogen-free, IEC 60332-1-2 flame and IEC 60811-404 hydraulic oil immersion (-30 °C to +80 °C flex)
  • Factory supply: Custom drum lengths across 7 standard cross-sections from MOQ 50 m in 7 to 45 working days
TF-XLPEPUR-JUMBO 0.6/1 kV Halogen-Free XLPE/PUR Aramid-Reinforced Mining Reeling Cable technical data
ParameterValue
Rated voltage0.6/1 kV U0/U (max. 0.7/1.2 kV AC and 0.9/1.8 kV DC; 2.5 kV AC test to DIN VDE 0250-813)
Size and pilot range3x25+3G6+2x1x1 up to 3x150+3G25+2x1x1.5 mm² with 3 split earths and 2 white/blue pilots
Tensile and bend limitsMax. 20 N/mm² conductor tensile load (1,500 to 9,000 N); min. bend 8 x OD reeling and 6 x OD fixed
Insulation and sheath90 °C XLPE core insulation, special PUR inner sheath and dull-yellow halogen-free PUR outer sheath
Operating temperature-30 °C to +80 °C flexible reeling (-40 °C to +80 °C fixed); 90 °C conductor max (250 °C short-circuit)
Chemical & fire testsHalogen-free to EN 60754, flame-retardant to IEC 60332-1-2, oil-resistant to IEC 60811-404
Supply termsMOQ 50 m; manufacturing lead time 7 to 45 working days

TF-XLPEPUR-JUMBO 0.6/1 kV Size, Diameter, Bend Radius and Tensile Schedule

TF-XLPEPUR-JUMBO 0.6/1 kV halogen-free XLPE/PUR mining reeling cable — min–max outer diameter, minimum 8 × max OD reeling bend radius, 20 N/mm² max dynamic pull and approximate weight
Model and core configurationOuter diameter min–max (mm)Min. 8 × OD reeling bend (mm)Max. dynamic pull at 20 N/mm² (N)Approx. weight (kg/km)Next step
TF-XLPEPUR-JUMBO 3x25+3G6+2x1x123.0–24.51961,5001,200Request this size
TF-XLPEPUR-JUMBO 3x35+3G6+2x1x1.527.0–28.52282,1001,580Request this size
TF-XLPEPUR-JUMBO 3x50+3G10+2x1x1.531.5–33.02643,0002,250Request this size
TF-XLPEPUR-JUMBO 3x70+3G16+2x1x1.535.5–37.53004,2003,120Request this size
TF-XLPEPUR-JUMBO 3x95+3G16+2x1x1.540.0–42.53405,7003,900Request this size
TF-XLPEPUR-JUMBO 3x120+3G25+2x1x1.544.0–46.53727,2005,020Request this size
TF-XLPEPUR-JUMBO 3x150+3G25+2x1x1.548.5–52.04169,0005,980Request this size

Maximum tensile load is calculated at 20 N/mm² across the three main copper phase conductors; central aramid carrier assists axial load sharing.

Routine AC dielectric test voltage is 2.5 kV in accordance with DIN VDE 0250-813; custom core counts and pilot sizes are manufactured to project order.

ASCII part references: TF-XLPEPUR-JUMBO 3x35+3G6+2x1x1.5; TF-XLPEPUR-JUMBO 3x50+3G10+2x1x1.5; TF-XLPEPUR-JUMBO 3x70+3G16+2x1x1.5; TF-XLPEPUR-JUMBO 3x95+3G16+2x1x1.5.

Standards

TF-XLPEPUR-JUMBO Standards and Test References

TF-XLPEPUR-JUMBO 0.6/1 kV Halogen-Free XLPE/PUR Aramid-Reinforced Mining Reeling Cable standards and test references
Standard or specificationApplication
EN / IEC 60228Class 5 multi-stranded annealed bare copper conductors.
IEC 60502-1 & DIN VDE 0250-81390 °C XLPE insulation wall thickness and 2.5 kV AC factory voltage test reference.
EN / IEC 60754 & 60332-1-2Halogen-free acid-gas verification and single-cable vertical flame propagation test.
DIN EN / IEC 60811-404Mineral and hydraulic oil resistance of the dull-yellow PUR outer sheath.

Certifications and document support

TEBAOFLEX ISO quality assurance and routine factory test reports

DIN Media — DIN VDE 0250-813 and DIN VDE 0207-21 standards reference

IEC Webstore — IEC 60228, IEC 60502, IEC 60332 and IEC 60793 standards references

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.