Intemp 250 BS G210 High Temperature PFA Equipment Wire
Intemp 250 BS G210 High Temperature PFA Equipment Wire is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. For higher ambient temperatures, de-rating factors should be applied according to the project design. If cables are enclosed, a further de-rating factor of 0.8 should be considered. When multiple cables are grouped together and touching, grouping de-rating factors should also be applied before final cable selection. Send the exact size, length, installation duty and documentation requirements for a technical quotation.
Intemp 250 BS G210 High Temperature PFA Equipment Wire is a TEBAOFLEX cable for the application and operating conditions identified in the original product record. For higher ambient temperatures, de-rating factors should be applied according to the project design. If cables are enclosed, a further de-rating factor of 0.8 should be considered. When multiple cables are grouped together and touching, grouping de-rating factors should also be applied before final cable selection. BS G210 cable is a high performance 0.6/1kV equipment wire designed for arduous high temperature conditions, offering moisture resistance, flexibility, toughness and continuous conductor operation up to 250°C. The source record places this product in high temperature cables. Before ordering, confirm the exact product variant, conductor or core arrangement, system rating, route conditions, equipment connection and required documentation against the project specification. The requested Intemp 250 BS G210 High Temperature PFA Equipment Wire should be evaluated as a complete cable assembly: review its intended equipment, conductor arrangement, installation method, movement duty, environment, terminations, dimensions and required documentation together. The V2 layout keeps the source-listed construction, application, technical and standard information available for a controlled engineering and procurement review.
Intemp 250 BS G210 High Temperature PFA Equipment Wire construction
Cable Construction
- Conductor: Class 5 flexible nickel-plated copper conductor.
- Insulation: PFA, Perfluoroalkoxy, for high temperature electrical performance.
- Separator: Mica tape for added thermal separation.
- Sheath: Glass fibre braid with a heat resistant varnish.
- Sheath Colour: Natural.
Intemp 250 BS G210 High Temperature PFA Equipment Wire applications
Applications
- High temperature equipment wiring
- Industrial heating systems and thermal process equipment
- Electrical wiring in confined high heat environments
- Applications requiring moisture resistance, toughness and flexibility
- Fixed wiring where continuous conductor temperatures may reach 250°C
Installation Notes
For higher ambient temperatures, de-rating factors should be applied according to the project design. If cables are enclosed, a further de-rating factor of 0.8 should be considered. When multiple cables are grouped together and touching, grouping de-rating factors should also be applied before final cable selection.
Selection checks
Confirm the equipment interface, installation method, route length, movement or flexing duty, environmental exposure, conductor or core requirements and project documentation before final selection.
Intemp 250 BS G210 High Temperature PFA Equipment Wire specifications
The source-listed technical notes are retained below. Confirm the final size, tolerance, installation basis and ordered configuration before release.
BS G210 Cable for 250°C High Temperature Equipment Wiring
BS G210 cable is a high temperature equipment wire designed for fixed installations where standard PVC or silicone cables may not provide enough thermal endurance. This Intemp 250 cable uses a Class 5 flexible nickel-plated copper conductor, PFA insulation, mica tape separator and a glass fibre braided sheath with heat resistant varnish, supporting continuous conductor operation up to 250°C.
Source-listed technical tables
The tables below retain the original product data, including units, ranges and ordering examples.
| Product Name | Intemp 250 BS G210 High Temperature PFA Equipment Wire |
| Cable Type | High temperature single core equipment wire |
| Standard | Generally to BS G210 specification for PTFE insulated equipment wire |
| Voltage Rating | 0.6/1kV |
| Temperature Rating | Fixed installation: -75°C to +250°C |
| Conductor | Class 5 flexible nickel-plated copper conductor |
| Insulation | PFA, Perfluoroalkoxy |
| Separator | Mica tape |
| Sheath | Glass fibre braid with heat resistant varnish |
| Sheath Colour | Natural |
| Size Range | 1mm², 1.5mm², 2.5mm², 4mm², 6mm², 10mm² and 16mm² |
| Minimum Bending Radius | Fixed installation: 10 x overall diameter |
| 1mm² | Approx. 25A |
| 1.5mm² | Approx. 40A |
| 2.5mm² | Approx. 54A |
| 4mm² | Approx. 74A |
| 6mm² | Approx. 98A |
| 10mm² | Approx. 135A |
| 16mm² | Approx. 180A |
Intemp 250 BS G210 High Temperature PFA Equipment Wire standards and compliance
The following standard references are carried over from the original product record. They identify the source basis and do not replace project-specific certification or inspection requirements.
- BS G210 cable is a high temperature equipment wire designed for fixed installations where standard PVC or silicone cables may not provide enough thermal endurance. This Intemp 250 cable uses a Class 5 flexible nickel-plated copper conductor, PFA insulation, mica tape separator and a glass fibre braided sheath with heat resistant varnish, supporting continuous conductor operation up to 250°C.
- Product Name Intemp 250 BS G210 High Temperature PFA Equipment Wire
- Standard Generally to BS G210 specification for PTFE insulated equipment wire
Where a project requires a test report, certificate, marking record or inspection release, include that requirement in the quotation request.
Request a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.