MIL-W-16878 / NEMA HP3 Type ET, E & EE Extruded PTFE Equipment Wire (250–1000 V)
Commercial/industrial sintered PTFE hook-up wires engineered to MIL-W-16878 and NEMA HP3 Type ET (250 V, 0.15 mm / 6 mil wall), Type E (600 V, 0.25 mm / 10 mil wall) and Type EE (1,000 V, 0.38 mm / 15 mil wall) specifications (TF-M16878-ET-E-EE) operate from -65 °C (-190 °C static) to +200 °C with silver-plated copper or +260 °C with nickel-plated copper (32–8 AWG, 305 m spools; U.S. DoD QPL listing not claimed).
Single-core sintered PTFE equipment wires engineered to MIL-W-16878 and NEMA HP3 Type ET (250 V), Type E (600 V) and Type EE (1,000 V) specifications deliver solder-iron-proof, outgassing-free chassis wiring from -65 °C (-190 °C fixed cryogenic) up to +260 °C, spanning 0.56 mm miniature 32 AWG Type ET sensor leads up to 5.46 mm 8 AWG Type EE high-voltage power leads.
In high-density power supplies, medical lasers, downhole oilfield tools, vacuum instrumentation and avionics ground-test racks, PVC, XLPE and even melt-extruded FEP/ETFE pull back from terminal pins when touched by a +370 °C soldering iron. Sintered paste-extruded PTFE has no true melt flow phase below +327 °C, maintaining exact strip-gap geometry, 2.1 dielectric constant and complete chemical/solvent immunity. Concentric 19- and 37-strand plated copper conductors resist flex fatigue and allow clean mechanical or thermal stripping for automated and hand-soldered terminations.
Select Type ET (6 mil wall, M16878/6) for miniature 250 V electronics, Type E (10 mil wall, M16878/4) for standard 600 V chassis harnesses, or Type EE (15 mil wall, M16878/5) for 1,000 V high-pot circuits in 10 MIL-STD-104 base colours plus stripes (non-QPL commercial supply, MOQ 305 m / 1,000 ft per colour, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
MIL-W-16878 / NEMA HP3 PTFE Wire Construction
Manufactured via cleanroom fine-powder PTFE billet paste extrusion, controlled drying and multi-zone high-temperature sintering with 100 % inline impulse/AC spark testing.

| Component | Material and construction |
|---|---|
| 1. Concentric Stranded Plated Copper Conductor (32 AWG to 8 AWG) | True concentric 7-, 19-, 37- or 133-strand silver-plated annealed copper (ASTM B298, >= 40 micro-inch silver for +200 °C) or nickel-plated copper (ASTM B355 for +260 °C). |
| 2. Paste-Extruded & Sintered Pure PTFE Insulation | Virgin polytetrafluoroethylene wall sintered to 0.15 mm (6 mil, Type ET), 0.25 mm (10 mil, Type E) or 0.38 mm (15 mil, Type EE) concentricity. |
| 3. MIL-STD-104 Colour & Helical Stripe Identification | 10 solid numerical colours (0 black through 9 white) plus optional 1 to 3 sintered fluoropolymer ink spiral tracer stripes. |
MIL-W-16878 & NEMA HP3 Slash Code Breakdown
- Type ET (M16878/6): 250 V AC ultra-thin 0.15 mm (6 mil) sintered PTFE wall (32–20 AWG)
- Type E (M16878/4): 600 V AC standard 0.25 mm (10 mil) sintered PTFE wall (30–10 AWG)
- Type EE (M16878/5): 1,000 V AC heavy 0.38 mm (15 mil) sintered PTFE wall (24–8 AWG)
- Grade A / B (SPC): Silver-plated copper (7-strand = A, 19-strand = B) rated -65 °C to +200 °C
- Grade C / F (NPC): Nickel-plated copper concentric stranding rated -65 °C to +260 °C
MIL-W-16878 RF, Medical, UHV Vacuum & MWD Applications
Engineered for commercial, industrial, medical, vacuum and energy OEM electronics demanding MIL-W-16878 / NEMA HP3 physical and dielectric precision without U.S. DoD QPL paperwork.

- High-density industrial RF amplifiers, HV switch-mode power supplies, medical imaging / surgical laser chassis and analytical mass spectrometers.
- High-vacuum / ultra-high-vacuum (UHV) deposition chambers, electron microscopes and cryogenic superconducting test leads.
- Downhole directional-drilling MWD/LWD electronics modules (+200 °C to +260 °C) and geothermal logging sonde internal harnesses.
- Industrial test benches, avionics ground-support racks and precision audio/instrumentation point-to-point turret wiring.
Type ET / E / EE vs UL 1180/1199 vs AS22759 vs VDE 5Y
| Wire Specification | Wall & Voltage Classes | Stranding & Put-Up Focus | Primary Buyer Segment |
|---|---|---|---|
| MIL-W-16878 / NEMA HP3 (this page) | ET (250 V), E (600 V), EE (1,000 V) | True concentric 7/19/37-strand AWG | Defense-style OEM electronics, UHV vacuum, medical & MWD tools |
| UL 1180 / 1213 / 1199 PTFE | UL 1213 (thin), UL 1180 (300 V), UL 1199 (600 V) | Appliance/AWM wall gauges | North American UL 758 commercial appliances & heaters |
| SAE AS22759 (/9–/12, /32–/46) | 600 V / 1,000 V aerospace airframe | PTFE, XL-ETFE & PTFE/polyimide | High-abrasion airframe, engine test cells & motorsport looms |
| VDE 5Y Metric PTFE (FLU02) | 300/500 V & 600/1,000 V | Metric 0.14–16 mm² Class 5 | European DIN/VDE machinery & furnace switchgear |
Type E (600 V, 10 mil) is dimensionally close to UL 1180 (300 V, 10 mil), whereas UL 1199 (600 V) uses a thicker 20 mil wall.
MIL-W-16878 / NEMA HP3 PTFE Wire RFQ Checklist
- Wall/voltage type: Type ET (250 V, 6 mil), Type E (600 V, 10 mil) or Type EE (1,000 V, 15 mil).
- AWG size (32 AWG to 8 AWG) and stranding count (solid, 7-strand or 19/37-strand concentric).
- Conductor plating: silver-plated copper (SPC, +200 °C, best solderability) or nickel-plated copper (NPC, +260 °C).
- MIL-STD-104 colour/stripe code, confirmation that commercial non-QPL supply is acceptable, and spool quantity (MOQ 305 m / 1,000 ft, 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Fluoropolymer & Equipment Wires
- Compare UL 1180, UL 1199, UL 1213 & UL 1815 Extruded PTFE Wire
- Compare Metric VDE 5Y PTFE & VDE 6Y FEP Single-Core Wire
- View UL 10086 & UL 1516 Abrasion-Resistant Extruded ETFE Wire
- Engineering guide: PTFE vs PFA vs FEP vs ETFE insulation limits
MIL-W-16878 Type ET, E & EE PTFE Wire FAQ
What is the difference between MIL-W-16878 Type ET, Type E and Type EE PTFE wire?
Insulation wall thickness and voltage rating: Type ET uses a 6 mil (0.15 mm) wall for 250 V miniature circuits, Type E uses a 10 mil (0.25 mm) wall for 600 V general chassis wiring, and Type EE uses a 15 mil (0.38 mm) wall for 1,000 V high-voltage duty.
Are TEBAOFLEX MIL-W-16878 / NEMA HP3 wires U.S. DoD QPL listed?
No — TEBAOFLEX manufactures commercial/industrial OEM wires engineered to MIL-W-16878 (/4, /5, /6) and NEMA HP3 dimensional, concentricity and dielectric test specifications; U.S. Department of Defense QPL listing is not claimed.
How does MIL-W-16878 Type E compare with UL 1180 and UL 1199 PTFE wire?
Both Type E and UL 1180 use a 10 mil (0.25 mm) sintered PTFE wall, so Type E achieves a 600 V rating in the same slim outer diameter where UL 758 assigns 300 V (UL 1180) and requires a 20 mil wall for 600 V (UL 1199).
Can sintered PTFE Type ET / E / EE wire be used in high-vacuum (UHV) chambers?
Yes — pure virgin sintered PTFE contains zero plasticisers, oils or curing agents, exhibiting ultra-low total mass loss (TML < 0.05 %) and near-zero collected volatile condensable material in UHV systems.
Are 305 m spools of MIL-W-16878 Type E / EE sintered PTFE wire supplied in single continuous lengths?
Because paste-extruded PTFE is ram-extruded from finite preformed billets rather than melt-extruded continuously, NEMA HP3 permits a limited number of spark-tested factory piece lengths per 305 m (1,000 ft) spool on larger gauges; specify melt-extruded PFA (UL 1726/1727) if zero-joint 500 m lengths are mandatory.
Type ET (250 V), Type E (600 V) & Type EE (1000 V) Schedules
MIL-W-16878 Wall Thickness, Dielectric Test & Spool Summary
- Three NEMA HP3 wall classes: Type ET (250 V, 6 mil / 0.15 mm ultra-thin), Type E (600 V, 10 mil / 0.25 mm standard) and Type EE (1,000 V, 15 mil / 0.38 mm heavy dielectric)
- Soldering-iron-proof PTFE: Paste-extruded sintered polytetrafluoroethylene will not melt, shrink back or char during dense hand soldering onto turret and multipin connectors
- SPC (+200 °C) & NPC (+260 °C): Concentric 7-, 19- or 37-strand silver-plated copper (NEMA HP3 Grade B/E, +200 °C) or nickel-plated copper (Grade C/F, +260 °C)
- Lowest fluoropolymer loss: 2.0–2.1 dielectric constant and < 0.0002 dissipation factor preserve pulse rise time and high-voltage corona margin at altitude
- Non-QPL industrial OEM supply: Engineered to MIL-W-16878 / NEMA HP3 dimensions and spark/dielectric tests (QPL listing not claimed); 305 m (1,000 ft) spools in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 250 V AC on Type ET (1500 V AC dielectric test), 600 V AC on Type E (2000 V AC test) and 1000 V AC on Type EE (3000 V AC test) |
| Gauge range and stranding | 32 AWG to 20 AWG on Type ET, 30 AWG to 10 AWG on Type E and 24 AWG to 8 AWG on Type EE in concentric 7, 19, 37 or 133 strands |
| Conductor plating and temperature | -65 C (-190 C static) to +200 C with silver-plated copper (SPC) or -65 C to +260 C continuous with nickel-plated copper (NPC) |
| Dielectric and flame properties | Pure sintered PTFE with 2.05 dielectric constant, under 0.0002 dissipation factor, zero solder shrinkback and non-flammable UL 94 V-0 / VW-1 rating |
| Standard put-up and lead time | 305 m (1000 ft) standard factory spools per colour and gauge (billet-matched put-ups) in 7 to 45 working days |
| Specification scope note | Commercial/industrial OEM wire engineered to MIL-W-16878 (slash /4, /5, /6) and NEMA HP3 Type ET, E and EE parameters; U.S. DoD QPL listing is not claimed |
| Vacuum outgassing and fluid immunity | Ultra-low TML/CVCM outgassing in high vacuum and complete resistance to fluxes, cleaning solvents, fuels, hydraulic oils and acids |
Type ET (250 V) & Type E (600 V) Extruded PTFE Wire Schedule
| Type & AWG Size | Slash / NEMA Ref. | Stranding (Wires/AWG) | Conductor Ø (mm) | Nom. Wall (mm / mil) | Nom. OD (mm / in) | Approx. Weight (kg/km) | Standard Spool MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| Type ET 30 AWG | M16878/6 (HP3-ET) | 7/38 SPC or NPC | 0.30 | 0.15 / 6 | 0.61 / 0.024 | 1.0 | 305 m spool | Request this size |
| Type ET 28 AWG | M16878/6 (HP3-ET) | 7/36 SPC or NPC | 0.38 | 0.15 / 6 | 0.69 / 0.027 | 1.4 | 305 m spool | Request this size |
| Type ET 26 AWG | M16878/6 (HP3-ET) | 7/34 or 19/38 | 0.48 | 0.15 / 6 | 0.79 / 0.031 | 2.1 | 305 m spool | Request this size |
| Type ET 24 AWG | M16878/6 (HP3-ET) | 7/32 or 19/36 | 0.61 | 0.15 / 6 | 0.91 / 0.036 | 3.0 | 305 m spool | Request this size |
| Type ET 22 AWG | M16878/6 (HP3-ET) | 7/30 or 19/34 | 0.76 | 0.15 / 6 | 1.07 / 0.042 | 4.3 | 305 m spool | Request this size |
| Type ET 20 AWG | M16878/6 (HP3-ET) | 7/28 or 19/32 | 0.97 | 0.15 / 6 | 1.27 / 0.050 | 6.4 | 305 m spool | Request this size |
| Type E 28 AWG | M16878/4 (HP3-E) | 7/36 SPC or NPC | 0.38 | 0.25 / 10 | 0.89 / 0.035 | 2.1 | 305 m spool | Request this size |
| Type E 26 AWG | M16878/4 (HP3-E) | 7/34 or 19/38 | 0.48 | 0.25 / 10 | 0.99 / 0.039 | 2.8 | 305 m spool | Request this size |
| Type E 24 AWG | M16878/4 (HP3-E) | 19/36 SPC or NPC | 0.61 | 0.25 / 10 | 1.12 / 0.044 | 3.9 | 305 m spool | Request this size |
| Type E 22 AWG | M16878/4 (HP3-E) | 19/34 SPC or NPC | 0.76 | 0.25 / 10 | 1.27 / 0.050 | 5.5 | 305 m spool | Request this size |
| Type E 20 AWG | M16878/4 (HP3-E) | 19/32 SPC or NPC | 0.97 | 0.25 / 10 | 1.47 / 0.058 | 8.2 | 305 m spool | Request this size |
| Type E 18 AWG | M16878/4 (HP3-E) | 19/30 SPC or NPC | 1.22 | 0.25 / 10 | 1.75 / 0.069 | 12.2 | 305 m spool | Request this size |
| Type E 16 AWG | M16878/4 (HP3-E) | 19/29 SPC or NPC | 1.45 | 0.28 / 11 | 2.03 / 0.080 | 16.8 | 305 m spool | Request this size |
| Type E 14 AWG | M16878/4 (HP3-E) | 19/27 SPC or NPC | 1.83 | 0.28 / 11 | 2.41 / 0.095 | 25.5 | 305 m spool | Request this size |
| Type E 12 AWG | M16878/4 (HP3-E) | 19/25 SPC or NPC | 2.31 | 0.30 / 12 | 2.92 / 0.115 | 39.0 | 305 m spool | Request this size |
| Type E 10 AWG | M16878/4 (HP3-E) | 37/26 SPC or NPC | 2.90 | 0.30 / 12 | 3.53 / 0.139 | 60.5 | 305 m spool | Request this size |
Type EE (1,000 V) Heavy-Wall Extruded PTFE Wire Schedule
| Type & AWG Size | Slash / NEMA Ref. | Stranding (Wires/AWG) | Nom. Wall (mm / mil) | Nom. OD (mm / in) | Dielectric Test (V AC) | Approx. Weight (kg/km) | Standard Spool MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| Type EE 24 AWG | M16878/5 (HP3-EE) | 19/36 SPC or NPC | 0.38 / 15 | 1.37 / 0.054 | 3,000 V | 5.4 | 305 m spool | Request this size |
| Type EE 22 AWG | M16878/5 (HP3-EE) | 19/34 SPC or NPC | 0.38 / 15 | 1.52 / 0.060 | 3,000 V | 7.1 | 305 m spool | Request this size |
| Type EE 20 AWG | M16878/5 (HP3-EE) | 19/32 SPC or NPC | 0.38 / 15 | 1.73 / 0.068 | 3,000 V | 10.0 | 305 m spool | Request this size |
| Type EE 18 AWG | M16878/5 (HP3-EE) | 19/30 SPC or NPC | 0.38 / 15 | 2.01 / 0.079 | 3,000 V | 14.4 | 305 m spool | Request this size |
| Type EE 16 AWG | M16878/5 (HP3-EE) | 19/29 SPC or NPC | 0.38 / 15 | 2.26 / 0.089 | 3,000 V | 19.2 | 305 m spool | Request this size |
| Type EE 14 AWG | M16878/5 (HP3-EE) | 19/27 SPC or NPC | 0.38 / 15 | 2.64 / 0.104 | 3,000 V | 28.4 | 305 m spool | Request this size |
| Type EE 12 AWG | M16878/5 (HP3-EE) | 19/25 SPC or NPC | 0.41 / 16 | 3.15 / 0.124 | 3,000 V | 42.5 | 305 m spool | Request this size |
| Type EE 10 AWG | M16878/5 (HP3-EE) | 37/26 SPC or NPC | 0.43 / 17 | 3.78 / 0.149 | 3,000 V | 65.2 | 305 m spool | Request this size |
| Type EE 8 AWG | M16878/5 (HP3-EE) | 133/29 SPC or NPC | 0.51 / 20 | 5.36 / 0.211 | 3,000 V | 108.0 | 305 m spool | Request this size |
ASCII part references for BOM entry: TF-HP3-ETB-26, TF-HP3-ETB-24, TF-HP3-EB-24, TF-HP3-EB-22, TF-HP3-EB-20, TF-HP3-EB-18, TF-HP3-EC-20 (NPC 260C), TF-HP3-EEB-18, TF-HP3-EEC-16.
NEMA HP3 letter code guide: first letter(s) ET / E / EE = voltage wall class (250 V / 600 V / 1,000 V); second letter B = 19-strand SPC (+200 °C), A = 7-strand SPC (+200 °C), C = 19-strand NPC (+260 °C).
MIL-W-16878, NEMA HP3, ASTM B298 & ASTM B355 Standards
| Standard or specification | Application |
|---|---|
| NEMA HP 3 (Superseding MIL-W-16878 /4, /5, /6 & /23, /25, /27) | Dimensional wall thickness, concentricity, 1,500–3,000 V AC dielectric test, spark test and thermal shock criteria for extruded PTFE hook-up wire (U.S. DoD QPL listing not claimed). |
| ASTM B298 & ASTM B355 | Silver-coated (>= 40 micro-inch) and nickel-coated soft copper wire conductor standards. |
| MIL-STD-104 | Standardised numerical insulation base colours (0–9) and helical tracer stripe colour limits. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and 100 % inline spark/dielectric verification
NEMA HP 3 — Electrical and Electronic PTFE Insulated High Temperature Hook-Up Wire
ASTM B298 — Standard Specification for Silver-Coated Soft or Annealed Copper Wire
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
PTFE Hook-Up Wire — UL 1180, UL 1199, UL 1213, UL 1815 & UL 1584 (200–260 °C)
A related cable option for a different application or duty profile.
View productVDE 5Y PTFE (260 °C, UL 11486) & VDE 6Y / 6YI1 FEP (205 °C) Metric Single-Core Wire
A related cable option for a different application or duty profile.
View productUL 10086, UL 1516 & UL 1523 Extruded ETFE Hook-Up Wire (150–200 °C, 300/600 V)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.