Flat Type G-GC 2000V Portable Mining Cable

Heavy-duty 2000 V three-conductor Flat Type G-GC portable mining trailing cable designed and manufactured to ICEA S-75-381 / NEMA WC 58 from 6 AWG through 4/0 AWG. Combines three shaped EPR-insulated tinned-copper phase conductors (black, white, red), one green elastomer-covered shaped grounding conductor and one yellow elastomer-insulated shaped ground-check conductor inside an extra-heavy-duty lead-cured CPE jacket.

Product information
Brand
TEBAOFLEX
Product overview

Underground AC shuttle cars, continuous miners, loading machines, roof bolters and mobile feeder-breakers frequently spool trailing cables onto narrow horizontal or vertical level-wind reels where round cables experience high contact pressure and jacket corkscrewing. Flat Type G-GC 2000 V portable mining cable arranges three power conductors, one equipment grounding conductor and one fail-safe ground-check (pilot) conductor in a single flat parallel plane to maximize crush resistance, lower minor-axis bending stress and pack smoothly on flat-spooling reels.

Manufactured in accordance with ICEA S-75-381 / NEMA WC 58 across 6 AWG through 4/0 AWG, each phase conductor uses rope-lay-stranded annealed tinned copper per ASTM B172 (133 to 532 strands) insulated with 90 °C Ethylene Propylene Rubber (EPR) in black, white and red core identification. Contoured D-shaped core profiles lock the conductors into the outer jacket web so individual cores cannot rotate, overlap or migrate during repeated tension peaks and roadway runovers.

Between the phase cores, a rope-lay-stranded tinned-copper grounding conductor (8 AWG to 1/0 AWG) covered in green elastomer and a shaped tinned-copper ground-check conductor (8 AWG to 5 AWG) insulated in yellow elastomer provide continuous earth fault path continuity and pilot loop monitoring on AC mining equipment where induced grounding-system voltages do not present a hazard.

An extra-heavy-duty lead-cured Chlorinated Polyethylene (CPE) outer jacket resists cutting, rock impact, abrasion, oil, moisture and sunlight from −40 °C to +90 °C, with optional high-visibility colored jackets, neoprene compounds or reflective stripes available for underground haulageways.

Explore the mining and tunneling cable range for related configurations.

Construction

Construction

The representative cutaway illustrates a 2000 V 3-conductor Flat Type G-GC mining trailing cable built to ICEA S-75-381, showing the three contoured EPR-insulated tinned-copper phase cores (black, white, red), shaped green elastomer-covered grounding core, shaped yellow elastomer-insulated ground-check core and extra-heavy-duty lead-cured black CPE outer jacket.

Axial cross-section of a Flat Type G-GC 2000V mining cable showing three large EPR phase cores and two shaped green ground and yellow ground-check cores aligned in a single flat parallel row inside a heavy black CPE sheath
Representative cable construction.
Flat Type G-GC 2000V Portable Mining Cable construction
ComponentMaterial and construction
Phase Conductors (3 × Power)6 AWG through 4/0 AWG annealed tinned copper, bunched wires, rope-lay-stranded per ASTM B172 (133 strands on 6 AWG; 259 strands on 4 AWG–1/0 AWG; 329 on 2/0 AWG; 413 on 3/0 AWG; 532 on 4/0 AWG).
Phase Core Insulation90 °C Ethylene Propylene Rubber (EPR), contoured/shaped to prevent conductor shifting under the flat jacket, color-coded black, white and red (0.060 in / 1.5 mm wall on 6–2 AWG; 0.080 in / 2.0 mm wall on 1–4/0 AWG).
Grounding Conductor (1 × Earth)Rope-lay-stranded annealed tinned copper (8 AWG to 1/0 AWG) with a shaped green elastomer covering engineered to lock the grounding core in position within the flat parallel assembly.
Ground-Check Conductor (1 × Pilot GC)Rope-lay-stranded annealed tinned copper (8 AWG on 6–4 AWG; 6 AWG on 3–1 AWG; 5 AWG on 1/0–4/0 AWG) with shaped yellow elastomer insulation for fail-safe ground-monitoring relays.
Outer JacketExtra-heavy-duty lead-cured Chlorinated Polyethylene (CPE) in black (optional high-visibility colors, polychloroprene/neoprene jacket or reflective safety stripe on request).
Applications

Applications

Specify Flat Type G-GC 2000 V cable for three-phase AC mobile mining equipment requiring pilot ground-check monitoring and flat-profile reel spooling or runover resistance.

Heavy-duty black Flat Type G-GC 2000V trailing cable paying out through a horizontal roller guide onto an underground mine roadway from a shuttle car cable reel
Application illustration.
  • Three-phase AC underground shuttle cars, coal loaders and bridge conveyors operating on horizontal or vertical flat-spooling cable reels.
  • Continuous miners, cutting machines and mobile feeder-breakers requiring fail-safe pilot ground-check loop monitoring up to 2000 V.
  • Underground roof bolters, face drills and mobile hydraulic power packs exposed to frequent tire/track runover and rib pinching.
  • Portable AC power drops and sectionalized mine load-center extensions where flat parallel geometry reduces minor-axis bend radius to 6 × minor height.
Specifications

Specifications

Flat Type G-GC 2000V Portable Mining Cable technical data
ParameterValue
Rated voltage and temperature2000 V phase-to-phase; 90 °C maximum continuous conductor operating temperature (−40 °C minimum cold bend).
Construction standardDesigned and manufactured in accordance with ICEA S-75-381 / NEMA WC 58 for portable mining cables; flame-retardant jacket formulated to MSHA 30 CFR Part 18 flame test profile.
Phase conductor range3 power conductors from 6 AWG (133 strands) through 4/0 AWG (532 strands) rope-lay tinned copper per ASTM B172.
Ground and ground-check cores1 green elastomer-covered tinned-copper ground (8 AWG to 1/0 AWG) plus 1 yellow elastomer-insulated tinned-copper ground-check core (8 AWG to 5 AWG).
Minimum bending radius6 × cable minor dimension (height) per ICEA S-75-381 and CSA C22.2 No. 96 for non-shielded flat portable mining cables.
Ampacity basis79 A (6 AWG) to 287 A (4/0 AWG) single cable in free air at 90 °C conductor temperature and 40 °C ambient per ICEA S-75-381; apply reel layer derating factors (0.85 for 1 layer, 0.65 for 2 layers, 0.45 for 3 layers, 0.35 for 4 layers) when spooled.
Flat vs Round Type G-GC boundarySelect Flat Type G-GC for flat-spooling shuttle car/loader reels and crush-prone roadway layouts; select Round Type G-GC or Type G-CGC for multi-directional torsion, round cable guides or balanced 3-ground wireless ground monitoring.
Flat Type G-GC 2000 V 3-Conductor Portable Mining Cable — Dimensions, Weights and 90 °C Ampacity (6 AWG – 4/0 AWG)
DesignationPhase SizePhase StrandNom. Insulation Wall (in / mm)Ground SizeGround-Check SizeNom. Dimensions H × WCopper Weight (lbs/kft / kg/km)Net Weight (lbs/kft / kg/km)Ampacity 90 °C / 40 °C (A)
3/C 6 AWG Flat Type G-GC6 AWG1330.060 / 1.58 AWG8 AWG0.67 × 1.69 in (17.0 × 42.9 mm)357 / 532970 / 144579
3/C 4 AWG Flat Type G-GC4 AWG2590.060 / 1.57 AWG8 AWG0.75 × 1.89 in (19.0 × 48.0 mm)507 / 7551245 / 1855104
3/C 3 AWG Flat Type G-GC3 AWG2590.060 / 1.56 AWG6 AWG0.78 × 2.08 in (19.8 × 52.8 mm)660 / 9821395 / 2080120
3/C 2 AWG Flat Type G-GC2 AWG2590.060 / 1.55 AWG6 AWG0.81 × 2.23 in (20.6 × 56.6 mm)807 / 12011750 / 2605138
3/C 1 AWG Flat Type G-GC1 AWG2590.080 / 2.04 AWG6 AWG0.96 × 2.50 in (24.4 × 63.5 mm)1000 / 14882090 / 3110161
3/C 1/0 AWG Flat Type G-GC1/0 AWG2590.080 / 2.03 AWG5 AWG1.01 × 2.67 in (25.6 × 67.8 mm)1258 / 18712470 / 3675186
3/C 2/0 AWG Flat Type G-GC2/0 AWG3290.080 / 2.02 AWG5 AWG1.09 × 2.86 in (27.7 × 68.1 mm)1567 / 23332940 / 4375215
3/C 3/0 AWG Flat Type G-GC3/0 AWG4130.080 / 2.01 AWG5 AWG1.18 × 3.12 in (30.0 × 79.2 mm)1939 / 28853515 / 5230249
3/C 4/0 AWG Flat Type G-GC4/0 AWG5320.080 / 2.01/0 AWG5 AWG1.24 × 3.30 in (31.5 × 83.8 mm)2485 / 36984200 / 6250287
Flat Type G-GC 2000 V — 60 Hz Phase-to-Phase Voltage Drop, Minimum Minor-Axis Bend Radius and Reel Layer Derating
Phase Size60 Hz V-Drop @ 80% PF (V/A/1000 ft)60 Hz V-Drop @ 90% PF (V/A/1000 ft)60 Hz V-Drop @ 100% PF (V/A/1000 ft)Min. Bend Radius (6 × Minor H)1-Layer Reel Ampacity (× 0.85)2-Layer Reel Ampacity (× 0.65)3-Layer Reel Ampacity (× 0.45)
6 AWG0.820.900.956 × minor dimension (4.0 in / 102 mm)67.2 A (1 layer × 0.85)51.4 A (2 layers × 0.65)35.6 A (3 layers × 0.45)
4 AWG0.540.580.606 × minor dimension (4.5 in / 114 mm)88.4 A (1 layer × 0.85)67.6 A (2 layers × 0.65)46.8 A (3 layers × 0.45)
3 AWG0.430.460.476 × minor dimension (4.7 in / 119 mm)102.0 A (1 layer × 0.85)78.0 A (2 layers × 0.65)54.0 A (3 layers × 0.45)
2 AWG0.350.380.386 × minor dimension (4.9 in / 124 mm)117.3 A (1 layer × 0.85)89.7 A (2 layers × 0.65)62.1 A (3 layers × 0.45)
1 AWG0.290.310.306 × minor dimension (5.8 in / 146 mm)136.9 A (1 layer × 0.85)104.7 A (2 layers × 0.65)72.5 A (3 layers × 0.45)
1/0 AWG0.240.250.246 × minor dimension (6.1 in / 154 mm)158.1 A (1 layer × 0.85)120.9 A (2 layers × 0.65)83.7 A (3 layers × 0.45)
2/0 AWG0.200.200.196 × minor dimension (6.5 in / 166 mm)182.8 A (1 layer × 0.85)139.8 A (2 layers × 0.65)96.8 A (3 layers × 0.45)
3/0 AWG0.160.170.156 × minor dimension (7.1 in / 180 mm)211.7 A (1 layer × 0.85)161.9 A (2 layers × 0.65)112.1 A (3 layers × 0.45)
4/0 AWG0.140.140.126 × minor dimension (7.4 in / 189 mm)244.0 A (1 layer × 0.85)186.6 A (2 layers × 0.65)129.2 A (3 layers × 0.45)

All dimensions and weights are nominal and subject to standard ICEA S-75-381 manufacturing tolerances; cut lengths carry a standard ±5% length tolerance.

Note on 2/0 AWG nominal width: the source specification table prints 1.09 × 2.86 in alongside 27.7 × 68.1 mm (2.86 in equals 72.6 mm mathematically); verify reel flange and roller-guide clearance against 2.86 in (72.6 mm) when sizing 2/0 AWG guides.

Ambient temperature correction factors for 90 °C EPR insulation (referenced to 40 °C ambient = 1.00): 10 °C = 1.26, 20 °C = 1.18, 30 °C = 1.10, 40 °C = 1.00, 50 °C = 0.90.

Maximum recommended working tension per conductor should not exceed 10% of rated copper tensile strength (approximately total power conductor cross-sectional area in sq. in. × 3000 lbs).

Standards

Standards

Flat Type G-GC 2000V Portable Mining Cable standards and test references
Standard or specificationApplication
ICEA S-75-381 / NEMA WC 58Standard for portable and power feeder cables for use in mines and similar applications (construction, dimensional and 90 °C ampacity basis).
ASTM B172 & ASTM B33Rope-lay-stranded annealed tinned copper conductors for flexible portable mining cables.
MSHA 30 CFR Part 18 & CAN/CSA C22.2 No. 96Flame-retardant jacket test criteria and portable power cable reference standards (confirm project-specific MSHA or CSA marking requirements at RFQ).

NEMA / ICEA S-75-381 (NEMA WC 58) portable and power feeder mining cable standards

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.