Flat Type G-GC 2000V Portable Mining Cable
Heavy-duty 2000 V three-conductor Flat Type G-GC portable mining trailing cable designed and manufactured to ICEA S-75-381 / NEMA WC 58 from 6 AWG through 4/0 AWG. Combines three shaped EPR-insulated tinned-copper phase conductors (black, white, red), one green elastomer-covered shaped grounding conductor and one yellow elastomer-insulated shaped ground-check conductor inside an extra-heavy-duty lead-cured CPE jacket.
Underground AC shuttle cars, continuous miners, loading machines, roof bolters and mobile feeder-breakers frequently spool trailing cables onto narrow horizontal or vertical level-wind reels where round cables experience high contact pressure and jacket corkscrewing. Flat Type G-GC 2000 V portable mining cable arranges three power conductors, one equipment grounding conductor and one fail-safe ground-check (pilot) conductor in a single flat parallel plane to maximize crush resistance, lower minor-axis bending stress and pack smoothly on flat-spooling reels.
Manufactured in accordance with ICEA S-75-381 / NEMA WC 58 across 6 AWG through 4/0 AWG, each phase conductor uses rope-lay-stranded annealed tinned copper per ASTM B172 (133 to 532 strands) insulated with 90 °C Ethylene Propylene Rubber (EPR) in black, white and red core identification. Contoured D-shaped core profiles lock the conductors into the outer jacket web so individual cores cannot rotate, overlap or migrate during repeated tension peaks and roadway runovers.
Between the phase cores, a rope-lay-stranded tinned-copper grounding conductor (8 AWG to 1/0 AWG) covered in green elastomer and a shaped tinned-copper ground-check conductor (8 AWG to 5 AWG) insulated in yellow elastomer provide continuous earth fault path continuity and pilot loop monitoring on AC mining equipment where induced grounding-system voltages do not present a hazard.
An extra-heavy-duty lead-cured Chlorinated Polyethylene (CPE) outer jacket resists cutting, rock impact, abrasion, oil, moisture and sunlight from −40 °C to +90 °C, with optional high-visibility colored jackets, neoprene compounds or reflective stripes available for underground haulageways.
Explore the mining and tunneling cable range for related configurations.
Construction
The representative cutaway illustrates a 2000 V 3-conductor Flat Type G-GC mining trailing cable built to ICEA S-75-381, showing the three contoured EPR-insulated tinned-copper phase cores (black, white, red), shaped green elastomer-covered grounding core, shaped yellow elastomer-insulated ground-check core and extra-heavy-duty lead-cured black CPE outer jacket.

| Component | Material and construction |
|---|---|
| Phase Conductors (3 × Power) | 6 AWG through 4/0 AWG annealed tinned copper, bunched wires, rope-lay-stranded per ASTM B172 (133 strands on 6 AWG; 259 strands on 4 AWG–1/0 AWG; 329 on 2/0 AWG; 413 on 3/0 AWG; 532 on 4/0 AWG). |
| Phase Core Insulation | 90 °C Ethylene Propylene Rubber (EPR), contoured/shaped to prevent conductor shifting under the flat jacket, color-coded black, white and red (0.060 in / 1.5 mm wall on 6–2 AWG; 0.080 in / 2.0 mm wall on 1–4/0 AWG). |
| Grounding Conductor (1 × Earth) | Rope-lay-stranded annealed tinned copper (8 AWG to 1/0 AWG) with a shaped green elastomer covering engineered to lock the grounding core in position within the flat parallel assembly. |
| Ground-Check Conductor (1 × Pilot GC) | Rope-lay-stranded annealed tinned copper (8 AWG on 6–4 AWG; 6 AWG on 3–1 AWG; 5 AWG on 1/0–4/0 AWG) with shaped yellow elastomer insulation for fail-safe ground-monitoring relays. |
| Outer Jacket | Extra-heavy-duty lead-cured Chlorinated Polyethylene (CPE) in black (optional high-visibility colors, polychloroprene/neoprene jacket or reflective safety stripe on request). |
Applications
Specify Flat Type G-GC 2000 V cable for three-phase AC mobile mining equipment requiring pilot ground-check monitoring and flat-profile reel spooling or runover resistance.

- Three-phase AC underground shuttle cars, coal loaders and bridge conveyors operating on horizontal or vertical flat-spooling cable reels.
- Continuous miners, cutting machines and mobile feeder-breakers requiring fail-safe pilot ground-check loop monitoring up to 2000 V.
- Underground roof bolters, face drills and mobile hydraulic power packs exposed to frequent tire/track runover and rib pinching.
- Portable AC power drops and sectionalized mine load-center extensions where flat parallel geometry reduces minor-axis bend radius to 6 × minor height.
Specifications
| Parameter | Value |
|---|---|
| Rated voltage and temperature | 2000 V phase-to-phase; 90 °C maximum continuous conductor operating temperature (−40 °C minimum cold bend). |
| Construction standard | Designed and manufactured in accordance with ICEA S-75-381 / NEMA WC 58 for portable mining cables; flame-retardant jacket formulated to MSHA 30 CFR Part 18 flame test profile. |
| Phase conductor range | 3 power conductors from 6 AWG (133 strands) through 4/0 AWG (532 strands) rope-lay tinned copper per ASTM B172. |
| Ground and ground-check cores | 1 green elastomer-covered tinned-copper ground (8 AWG to 1/0 AWG) plus 1 yellow elastomer-insulated tinned-copper ground-check core (8 AWG to 5 AWG). |
| Minimum bending radius | 6 × cable minor dimension (height) per ICEA S-75-381 and CSA C22.2 No. 96 for non-shielded flat portable mining cables. |
| Ampacity basis | 79 A (6 AWG) to 287 A (4/0 AWG) single cable in free air at 90 °C conductor temperature and 40 °C ambient per ICEA S-75-381; apply reel layer derating factors (0.85 for 1 layer, 0.65 for 2 layers, 0.45 for 3 layers, 0.35 for 4 layers) when spooled. |
| Flat vs Round Type G-GC boundary | Select Flat Type G-GC for flat-spooling shuttle car/loader reels and crush-prone roadway layouts; select Round Type G-GC or Type G-CGC for multi-directional torsion, round cable guides or balanced 3-ground wireless ground monitoring. |
| Designation | Phase Size | Phase Strand | Nom. Insulation Wall (in / mm) | Ground Size | Ground-Check Size | Nom. Dimensions H × W | Copper Weight (lbs/kft / kg/km) | Net Weight (lbs/kft / kg/km) | Ampacity 90 °C / 40 °C (A) |
|---|---|---|---|---|---|---|---|---|---|
| 3/C 6 AWG Flat Type G-GC | 6 AWG | 133 | 0.060 / 1.5 | 8 AWG | 8 AWG | 0.67 × 1.69 in (17.0 × 42.9 mm) | 357 / 532 | 970 / 1445 | 79 |
| 3/C 4 AWG Flat Type G-GC | 4 AWG | 259 | 0.060 / 1.5 | 7 AWG | 8 AWG | 0.75 × 1.89 in (19.0 × 48.0 mm) | 507 / 755 | 1245 / 1855 | 104 |
| 3/C 3 AWG Flat Type G-GC | 3 AWG | 259 | 0.060 / 1.5 | 6 AWG | 6 AWG | 0.78 × 2.08 in (19.8 × 52.8 mm) | 660 / 982 | 1395 / 2080 | 120 |
| 3/C 2 AWG Flat Type G-GC | 2 AWG | 259 | 0.060 / 1.5 | 5 AWG | 6 AWG | 0.81 × 2.23 in (20.6 × 56.6 mm) | 807 / 1201 | 1750 / 2605 | 138 |
| 3/C 1 AWG Flat Type G-GC | 1 AWG | 259 | 0.080 / 2.0 | 4 AWG | 6 AWG | 0.96 × 2.50 in (24.4 × 63.5 mm) | 1000 / 1488 | 2090 / 3110 | 161 |
| 3/C 1/0 AWG Flat Type G-GC | 1/0 AWG | 259 | 0.080 / 2.0 | 3 AWG | 5 AWG | 1.01 × 2.67 in (25.6 × 67.8 mm) | 1258 / 1871 | 2470 / 3675 | 186 |
| 3/C 2/0 AWG Flat Type G-GC | 2/0 AWG | 329 | 0.080 / 2.0 | 2 AWG | 5 AWG | 1.09 × 2.86 in (27.7 × 68.1 mm) | 1567 / 2333 | 2940 / 4375 | 215 |
| 3/C 3/0 AWG Flat Type G-GC | 3/0 AWG | 413 | 0.080 / 2.0 | 1 AWG | 5 AWG | 1.18 × 3.12 in (30.0 × 79.2 mm) | 1939 / 2885 | 3515 / 5230 | 249 |
| 3/C 4/0 AWG Flat Type G-GC | 4/0 AWG | 532 | 0.080 / 2.0 | 1/0 AWG | 5 AWG | 1.24 × 3.30 in (31.5 × 83.8 mm) | 2485 / 3698 | 4200 / 6250 | 287 |
| Phase Size | 60 Hz V-Drop @ 80% PF (V/A/1000 ft) | 60 Hz V-Drop @ 90% PF (V/A/1000 ft) | 60 Hz V-Drop @ 100% PF (V/A/1000 ft) | Min. Bend Radius (6 × Minor H) | 1-Layer Reel Ampacity (× 0.85) | 2-Layer Reel Ampacity (× 0.65) | 3-Layer Reel Ampacity (× 0.45) |
|---|---|---|---|---|---|---|---|
| 6 AWG | 0.82 | 0.90 | 0.95 | 6 × minor dimension (4.0 in / 102 mm) | 67.2 A (1 layer × 0.85) | 51.4 A (2 layers × 0.65) | 35.6 A (3 layers × 0.45) |
| 4 AWG | 0.54 | 0.58 | 0.60 | 6 × minor dimension (4.5 in / 114 mm) | 88.4 A (1 layer × 0.85) | 67.6 A (2 layers × 0.65) | 46.8 A (3 layers × 0.45) |
| 3 AWG | 0.43 | 0.46 | 0.47 | 6 × minor dimension (4.7 in / 119 mm) | 102.0 A (1 layer × 0.85) | 78.0 A (2 layers × 0.65) | 54.0 A (3 layers × 0.45) |
| 2 AWG | 0.35 | 0.38 | 0.38 | 6 × minor dimension (4.9 in / 124 mm) | 117.3 A (1 layer × 0.85) | 89.7 A (2 layers × 0.65) | 62.1 A (3 layers × 0.45) |
| 1 AWG | 0.29 | 0.31 | 0.30 | 6 × minor dimension (5.8 in / 146 mm) | 136.9 A (1 layer × 0.85) | 104.7 A (2 layers × 0.65) | 72.5 A (3 layers × 0.45) |
| 1/0 AWG | 0.24 | 0.25 | 0.24 | 6 × minor dimension (6.1 in / 154 mm) | 158.1 A (1 layer × 0.85) | 120.9 A (2 layers × 0.65) | 83.7 A (3 layers × 0.45) |
| 2/0 AWG | 0.20 | 0.20 | 0.19 | 6 × minor dimension (6.5 in / 166 mm) | 182.8 A (1 layer × 0.85) | 139.8 A (2 layers × 0.65) | 96.8 A (3 layers × 0.45) |
| 3/0 AWG | 0.16 | 0.17 | 0.15 | 6 × minor dimension (7.1 in / 180 mm) | 211.7 A (1 layer × 0.85) | 161.9 A (2 layers × 0.65) | 112.1 A (3 layers × 0.45) |
| 4/0 AWG | 0.14 | 0.14 | 0.12 | 6 × minor dimension (7.4 in / 189 mm) | 244.0 A (1 layer × 0.85) | 186.6 A (2 layers × 0.65) | 129.2 A (3 layers × 0.45) |
All dimensions and weights are nominal and subject to standard ICEA S-75-381 manufacturing tolerances; cut lengths carry a standard ±5% length tolerance.
Note on 2/0 AWG nominal width: the source specification table prints 1.09 × 2.86 in alongside 27.7 × 68.1 mm (2.86 in equals 72.6 mm mathematically); verify reel flange and roller-guide clearance against 2.86 in (72.6 mm) when sizing 2/0 AWG guides.
Ambient temperature correction factors for 90 °C EPR insulation (referenced to 40 °C ambient = 1.00): 10 °C = 1.26, 20 °C = 1.18, 30 °C = 1.10, 40 °C = 1.00, 50 °C = 0.90.
Maximum recommended working tension per conductor should not exceed 10% of rated copper tensile strength (approximately total power conductor cross-sectional area in sq. in. × 3000 lbs).
Standards
| Standard or specification | Application |
|---|---|
| ICEA S-75-381 / NEMA WC 58 | Standard for portable and power feeder cables for use in mines and similar applications (construction, dimensional and 90 °C ampacity basis). |
| ASTM B172 & ASTM B33 | Rope-lay-stranded annealed tinned copper conductors for flexible portable mining cables. |
| MSHA 30 CFR Part 18 & CAN/CSA C22.2 No. 96 | Flame-retardant jacket test criteria and portable power cable reference standards (confirm project-specific MSHA or CSA marking requirements at RFQ). |
NEMA / ICEA S-75-381 (NEMA WC 58) portable and power feeder mining cable standards
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type G-GC Cable 2000V Portable Mining Power Cable
A related cable option for a different application or duty profile.
View productFlat Type G 2/C 2000 V Twin Parallel Portable DC Mining & Shuttle-Car Reeling Cable (6 AWG–4/0 AWG)
A related cable option for a different application or duty profile.
View productType SHD Flat 3/C 2000 V Individually Shielded Portable Mining Reeling & Shuttle-Car Cable (6 AWG–4/0 AWG)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.