TF-IFL & TF-WCHC Induction Melting & Vacuum Furnace Water-Cooled Power Lead Cable (70–2,500 MCM / 35–2,000 mm²)
TF-IFL and TF-WCHC (TF-IFL-WCHC-LEAD) are custom-terminated water-cooled flexible copper power lead assemblies spanning 70 MCM to 2,500 MCM (35 mm² to 2,000 mm², 950 A to 20,000 A) for coreless induction melting furnaces, vacuum furnaces, polysilicon CVD reactors and glass melters. Built with rope-lay Cu-HCP/Cu-ETP conductors, solderless CNC-machined copper heads (JIC 37° swivel flare, NPT/BSP or flat palm) and 6–15 kV dielectric hoses.
TF-IFL (North American 70–2,500 MCM) and TF-WCHC (European metric 95–2,000 mm²) water-cooled flexible power lead assemblies carry 950 A to 20,000 A between stationary power-supply manifolds and tilting coreless induction melting coils, vacuum-induction feedthroughs, graphitizing furnaces and polysilicon reduction reactors.
Every furnace tilt cycle bends and twists the flexible power leads while 50/60 Hz to 3,000 Hz alternating currents concentrate toward the outer conductor perimeter through skin and proximity effects. Solid-core ropes soldered into cast lugs suffer tin recrystallization and water-passage choking; TEBAOFLEX lays fine Cu-ETP / Cu-HCP copper ropes around a resilient self-flushing central water-channel core (including Center-Channel 95–500 mm² builds) and cold-presses them into CNC-machined oxygen-free copper heads under circumferential hydraulic compression.
Specify TF-IFL with female SAE 37° JIC swivel nuts (#8C to #32C) or O-ring vacuum plugs for foundry tilting melters; specify TF-WCHC Type A (standard) or Type B (with vulcanized intermediate support collars that prevent saddle clamps from pinching coolant flow) for 50/60 Hz vacuum, glass and non-ferrous furnaces; above 2 kHz or where ultra-low inductive reactance is critical, switch to TF-HC10K hollow-core enameled-Litz or TF-WCCX two-conductor coaxial leads. MOQ 2 pieces (1 pair) or 1 set, 7 to 45 working days.
Explore the high-temperature wire and cable range for related configurations.
TF-IFL & TF-WCHC Water-Cooled Power Lead Construction
Custom-built to approved terminal drawings using DIN EN 13601 / ASTM B187 high-conductivity copper heads, AISI 304/316 non-magnetic bands and 10 bar hydro-tested hoses.

| Component | Material and construction |
|---|---|
| 1. Rope-Lay High-Conductivity Copper around Central Coolant Channel | 100 % IACS soft-annealed Cu-ETP / oxygen-free Cu-HCP stranded ropes concentrically laid over an open spiral or resilient rubber water core for uniform 360-degree heat removal. |
| 2. Solderless Hydraulically Pressed CNC Copper Terminal Heads | Machined from forged Cu-HCP bar (optional silver- or tin-plated contact palms) in flat 1–8 hole flags, 45°/90° elbows, offset repairable heads, or #8C–#32C 37° JIC female swivel nuts. |
| 3. Electrically Insulating Cord-Reinforced EPDM / CR Coolant Hose | Flame-retardant, ozone- and heat-resistant multi-ply elastomer hose (5 kV to 15 kV dielectric withstand; 6 bar working / 10 bar test / 18 bar burst) clamped with non-magnetic 304/316 stainless bands. |
| 4. Optional Slag-Splash Pyrojacket & Type B Intermediate Clamping Collars | Optional silicone-fiberglass thermal sleeve (-T) for foundry pouring-spout splash protection, plus internal solid copper clamping rings (Type B) for long-span routing. |
TF-IFL & TF-WCHC Model & Terminal Code Breakdown
- TF-IFL-<MCM>: North American induction furnace water-cooled power lead (70 MCM to 2,500 MCM, JIC 37° swivel or NPT flat head)
- TF-WCHC-<mm²>A: European metric 50/60 Hz water-cooled high-current cable Type A (120–1,000 mm², standard pressed Cu-HCP heads)
- TF-WCHC-<mm²>B: Metric Type B build with internal solid clamping rings for intermediate saddle-clamp support on long spans
- TF-WCHC-<mm²>C / M: Center-Channel hollow-core (95–500 mm²) or Multi-Conductor heavy foundry build (1,200–2,000 mm², up to 20 kA)
- -T Suffix: Optional vulcanized or slip-on +500 °C iron-oxide silicone-fiberglass molten-splash thermal sleeve
TF-IFL Induction Melting, Vacuum, CVD & Glass Furnace Duty
Engineered as OEM-compatible replacement and new-build power leads for foundry melting, vacuum metallurgy, crystal growing and chemical furnaces.

- Coreless iron, steel, brass and aluminum tilting induction melting furnaces (50 Hz to 3,000 Hz coil feed leads up to 8,000–20,000 A).
- Vacuum induction melting (VIM), vacuum arc remelting (VAR), plasma-hearth and directional-solidification investment-casting furnaces.
- Polysilicon Siemens CVD bell-jar reactors, monocrystalline silicon Czochralski heaters, Acheson graphitizing furnaces and optical-glass melters.
- High-current rectifier-to-busbar flexible transitions, resistance-heating bus jumpers and mobile transformer load-bank test leads.
TF-IFL / TF-WCHC vs 10 kHz Hollow-Core vs EAF Water-Cooled
| Water-Cooled Series | Section & Frequency | Conductor & Head Design | Target Furnace Equipment |
|---|---|---|---|
| TF-IFL & TF-WCHC (this page) | 35–2,000 mm² (70–2,500 MCM); 50 Hz–3 kHz | Bare/tinned copper ropes; JIC swivel, NPT or flat pressed Cu heads | Coreless tilting induction melters, vacuum, CVD & glass furnaces |
| TF-HC2K / TF-HC10K & TF-WCCX | 70–1,015 mm² / 300–6,000 MCM; up to 10 kHz | Double-enameled hollow-core Litz or 2-pole coaxial low-reactance | 1–10 kHz billet heaters, hardening coils & low-voltage-drop MF links |
| EAF / LF Water-Cooled Cable | 1,000–7,000 mm²; 50/60 Hz (5–45 kA) | Multi-rope 400/500 mm² strands + rotating swivel & slag bumpers | Steelmaking Electric Arc Furnaces (EAF) & Ladle Furnaces (LF) |
| SAF High-Current Furnace Cable | 750–7,000 mm²; 50/60 Hz | Ring-nut & heavy pressed palms for secondary copper bus-tubes | Submerged-Arc Furnaces (ferroalloy, silicon, calcium carbide) |
Above 1,500–2,000 Hz on cables >= 300 mm², bare-strand skin effect triples AC losses (R_AC/R_DC > 3.0); upgrade to TF-HC10K enameled-wire hollow-core leads to cut kW heat loss.
TF-IFL & TF-WCHC Water-Cooled Lead Drawing & RFQ Checklist
- Conductor cross-section (MCM or mm²), operating current (A), system voltage (V) and inverter frequency (Hz or kHz).
- Exact overall assembly length measured hole-center to hole-center (or JIC flare seat to seat) in mm or inches.
- End A and End B terminal configuration (flat palm hole pattern & rotational offset angle, #8C–#32C 37° JIC swivel nut, or O-ring vacuum flange) — attach sketch or existing OEM part reference.
- Coolant port thread (1/4" to 1" NPT or G/BSPP, axial end port Pe vs side port Ps) and optional +500 °C splash pyrojacket (-T).
- Required quantity in matched pairs or sets (MOQ 2 pieces / 1 pair or 1 furnace set, 7 to 45 working days).
Related selection resources
- Browse all Furnace Water-Cooled & High-Temperature Speciality Cables
- Upgrade to 2 kHz & 10 kHz Hollow-Core Litz & Two-Conductor Coaxial Leads
- Compare Heavy 1,000–7,000 mm² Steelmaking EAF Water-Cooled Cable
- Compare SAF Submerged-Arc & Ferroalloy Furnace Water-Cooled Cable
- Pair with TF-PYRO-SM +1,090 °C Slag-Protected Furnace Control Cable
- Compare Dry Air-Cooled 1 kV High-Frequency Litz Power Cable
TF-IFL & TF-WCHC Induction Furnace Water-Cooled Lead FAQ
How do I measure the assembly length when ordering TF-IFL or TF-WCHC water-cooled furnace leads?
Always specify pin-to-pin overall length from bolt-hole center to bolt-hole center on flat palms, or from flare-seat to flare-seat on 37° JIC swivel leads—never measure only the black rubber hose, which is shorter than the full copper assembly.
What is the difference between TF-WCHC Type A and Type B water-cooled cables?
2 structural mounting designs separate them: Type A is a continuous flexible hose assembly supported solely at its two copper end heads, whereas Type B integrates solid internal copper clamping collars along the span so intermediate saddle brackets grip securely without pinching the coolant hose.
At what frequency should I switch from TF-IFL bare-copper leads to TF-HC10K enameled hollow-core leads?
Switch above 1.5 kHz to 2 kHz on cross-sections >= 250 mm² (500 MCM): Table 1 shows R_AC/R_DC rises to 3.69–5.60 at 3 kHz in bare stranded copper, whereas double-enameled hollow-core Litz in TF-HC10K suppresses skin effect up to 10 kHz.
What cooling water pressure, temperature and conductivity do TF-IFL and TF-WCHC leads require?
Operate at 2.5 to 6.0 bar (35 to 87 PSI) inlet pressure with outlet water temperature kept strictly below +65 °C (+150 °F); on induction coils operating above 600 V AC, maintain water conductivity below 20–30 μS/cm to prevent electrolytic copper head erosion.
What is the minimum order quantity and lead time for custom TF-IFL and TF-WCHC assemblies?
2 pieces (1 matched pair) or 1 complete furnace set custom-machined to your terminal drawing, 100 % hydro-tested at 10 bar and shipped in 7 to 45 working days.
TF-IFL (MCM) & TF-WCHC (mm²) Electrical & Flow Schedule
TF-IFL & TF-WCHC Current, Pressure, Port & Pair MOQ Summary
- 70–2,500 MCM & 95–2,000 mm² span: Bridges the exact foundry/vacuum furnace range below 7,000 mm² steelmaking EAF cables, covering 950 A desktop/tilting melters up to 20 kA mains bus links
- JIC 37° swivel, flange & flat heads: Precision-machined Cu-HCP 99.95 % copper terminals with #8C–#32C SAE 37° flare swivel nuts, O-ring vacuum flanges, offset palms or intermediate Type B clamps
- Verified skin-effect R_AC/R_DC data: Published 60 Hz, 1 kHz and 3 kHz AC/DC resistance multipliers prevent overheating when sizing leads between solid-state inverters and tilting induction coils
- 10 bar hydro-tested 15 kV hose: Cord-reinforced non-conductive EPDM / CR coolant hoses (working pressure 6 bar, 100 % factory hydro-tested at 10 bar) with optional +500 °C splash pyrojacket
- 2 pieces (1 pair) assembly MOQ: Manufactured to exact pin-to-pin or flare-to-flare drawing length from a 2 pieces (1 pair) or 1 furnace set minimum order in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | Up to 1000 V to 3000 V AC coil operating voltage with 5 kV to 15 kV dielectric insulating coolant hose |
| Cross-section and current span | 70 MCM to 2500 MCM (North American TF-IFL) and 95 mm2 to 2000 mm2 (Metric TF-WCHC), rated 950 A to 20000 A at 50/60 Hz |
| Terminal and water port styles | Flat 1 to 8 hole palms, 45/90 deg flags, SAE 37 deg JIC swivel nuts (#8C to #32C), and 1/4 in to 1 in NPT or BSPP axial/side water ports |
| Coolant pressure and exhaust limit | 6 bar (87 PSI) maximum continuous water pressure, 10 bar (145 PSI) factory hydro-test, maximum continuous water outlet temperature +65 C (+150 F) |
| Minimum order and lead time | 2 pieces (1 matched pair) or 1 furnace set built to approved length and terminal drawing in 7 to 45 working days |
| Water quality requirement | Clean closed-loop cooling water with inlet temperature +15 C to +32 C (low-conductivity treated water below 20 uS/cm recommended above 600 V) |
| Optional thermal armour | Vulcanized or slip-on iron-oxide silicone-fiberglass heat shield (-T) and rubber anti-chafing rings for pouring-deck splash zones |
TF-IFL (70–2,500 MCM) Foundry Induction Power Lead Schedule
| Model & MCM Size | Metric Equiv. (mm²) | Hose Nom. OD (mm / in) | R_DC at 20 °C (μΩ/ft) | R_AC / R_DC (60 Hz / 1 kHz / 3 kHz) | Min. Water Flow (GPM) | Standard Fitting / Port | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| TF-IFL-100 (100 MCM) | 50 mm² | 29 / 1.16 | 103.7 | 1.00 / 1.22 / 1.90 | 2.0 | #10C JIC or Flat + 1/4 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-133 (133 MCM) | 67 mm² | 31 / 1.22 | 78.0 | 1.00 / 1.28 / 2.04 | 2.0 | #12C JIC or Flat + 3/8 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-216 (216 MCM) | 109 mm² | 31 / 1.22 | 48.0 | 1.00 / 1.56 / 2.52 | 2.0 | Flat Palm + 3/8 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-266 (266 MCM) | 135 mm² | 39 / 1.56 | 40.0 | 1.01 / 1.71 / 2.77 | 4.0 | #16C JIC or Flat + 1/2 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-350 (350 MCM) | 177 mm² | 39 / 1.56 | 29.6 | 1.01 / 1.92 / 3.13 | 4.0 | Flat Palm + 1/2 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-400 (400 MCM) | 203 mm² | 39 / 1.56 | 25.9 | 1.01 / 2.04 / 3.33 | 4.0 | Flat Palm + 1/2 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-500 (500 MCM) | 253 mm² | 47 / 1.88 | 20.7 | 1.02 / 2.25 / 3.69 | 4.0 | #20C JIC or Flat + 1/2 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-600 (600 MCM) | 304 mm² | 47 / 1.88 | 17.3 | 1.03 / 2.44 / 4.01 | 4.0 | Flat Palm + 1/2 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-750 (750 MCM) | 380 mm² | 52 / 2.06 | 13.8 | 1.04 / 2.69 / 4.45 | 6.0 | #24C JIC or Flat + 1/2 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-1000 (1000 MCM) | 507 mm² | 59 / 2.34 | 10.4 | 1.07 / 2.88 / 5.10 | 6.0 | #32C JIC or Flat + 1/2 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-1200 (1200 MCM) | 608 mm² | 67 / 2.62 | 8.64 | 1.10 / 3.35 / 5.60 | 8.0 | 2-Hole Flag + 1/2 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-1500 (1500 MCM) | 760 mm² | 80 / 3.16 | 6.91 | 1.15 / 3.80 / — | 8.0 | 2/4-Hole Flag + 3/4 NPT | 2 pcs (1 pair) | Request this size |
| TF-IFL-2500 (2500 MCM) | 1,267 mm² | 95 / 3.75 | 4.15 | 1.26 / — / — | 8.0 | 4-Hole Flag + 3/4 NPT | 2 pcs (1 pair) | Request this size |
TF-WCHC (95–2,000 mm²) Metric Mains & Vacuum Furnace Schedule
| Model & Cross-Section | Design Architecture | 50/60 Hz Ref. Current (A) | Palm Width × Thickness (mm) | Coolant Thread (BSPP / G) | Operating / Test Pressure | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|
| TF-WCHC-95C (95 mm²) | Center-Channel Hollow | 1,100 | 25 × 12 | G 1/4" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCHC-120A/B (120 mm²) | Single-Rope Type A / B | 1,600 | 25 × 10 | G 1/4" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCHC-150C (150 mm²) | Center-Channel Hollow | 1,500 | 30 × 12 | G 3/8" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCHC-185A/B (185 mm²) | Single-Rope Type A / B | 2,500 | 30 × 12 | G 3/8" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCHC-300A/B (300 mm²) | Single-Rope Type A / B | 3,700 | 35 × 15 | G 3/8" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCHC-400A/B (400 mm²) | Single-Rope Type A / B | 4,500 | 42 × 20 | G 3/8" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCHC-500A/B (500 mm²) | Single-Rope Type A / B | 5,500 | 55 × 20 | G 3/8" or 1/2" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCHC-750A/B (750 mm²) | Single/Multi-Rope | 7,500 | 55–65 × 22 | G 3/8" or 3/4" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCHC-1000A/B (1,000 mm²) | Single/Multi-Rope | 10,000 | 70 × 25–30 | G 1/2" or 1" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCHC-1200M (1,200 mm²) | Multi-Conductor | 12,000 | 80 × 30 | G 1" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCHC-1600M (1,600 mm²) | Multi-Conductor | 16,000 | 90 × 35 | G 1" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
| TF-WCHC-2000M (2,000 mm²) | Multi-Conductor | 20,000 | 100 × 35 | G 1" | 6 bar / 10 bar | 2 pcs (1 pair) | Request this size |
Thermal & flow sizing equations: Power Loss P (W) = I² × R_AC × L; Minimum Coolant Flow (GPM) = P / (268 × ΔT_°C) or Flow (L/min) = 0.0143 × P / ΔT_°C, keeping coolant outlet temperature <= +65 °C (+150 °F). Final palm drilling and thread geometry follow the approved quotation drawing.
ASCII part references for BOM and ERP entry: TF-IFL-266, TF-IFL-350, TF-IFL-500, TF-IFL-750, TF-IFL-1000, TF-IFL-1500, TF-IFL-2500, TF-WCHC-300A, TF-WCHC-500A, TF-WCHC-750B, TF-WCHC-1000A, TF-WCHC-1600M, TF-WCHC-2000M.
TF-IFL & TF-WCHC Reference Standards (EN 13601 & SAE J514)
| Standard or specification | Application |
|---|---|
| DIN EN 13601 & ASTM B187 / EN 13602 | High-conductivity oxygen-free Cu-HCP / ETP copper bar for machined terminal palms and fine-drawn annealed copper wire ropes. |
| SAE J514 (37° JIC Flare), ANSI/ASME B1.20.1 (NPT) & ISO 228-1 (G/BSPP) | Leak-tight hydraulic/coolant swivel flare, tapered NPT and parallel BSPP water-port thread geometry; 100 % hydro-tested at 10 bar. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and 10 bar hydro-test / micro-ohm inspection
ASTM B187 — Standard Specification for Copper Bar, Bus Bar, Rod and Shapes
SAE J514 — 37-Degree Flared Hydraulic & Coolant Tube Fittings
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-HC10K, TF-HC2K & TF-WCCX 2 kHz / 10 kHz Hollow-Core Litz & Two-Conductor Coaxial Water-Cooled Cable
A related cable option for a different application or duty profile.
View productEAF & Ladle Furnace (LF) Water-Cooled Cable — 1,000–7,000 mm² Fluted-Core, Bumper & Swivel Secondary Leads
A related cable option for a different application or duty profile.
View productTF-SAF & TF-WCF Submerged-Arc (SAF), Ferroalloy & Smelting Water-Cooled Furnace Cable (750–7,000 mm²)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.