High Temperature Cables TEBAOFLEX

TF-IFL & TF-WCHC Induction Melting & Vacuum Furnace Water-Cooled Power Lead Cable (70–2,500 MCM / 35–2,000 mm²)

TF-IFL and TF-WCHC (TF-IFL-WCHC-LEAD) are custom-terminated water-cooled flexible copper power lead assemblies spanning 70 MCM to 2,500 MCM (35 mm² to 2,000 mm², 950 A to 20,000 A) for coreless induction melting furnaces, vacuum furnaces, polysilicon CVD reactors and glass melters. Built with rope-lay Cu-HCP/Cu-ETP conductors, solderless CNC-machined copper heads (JIC 37° swivel flare, NPT/BSP or flat palm) and 6–15 kV dielectric hoses.

Product information
SKU
TF-IFL-WCHC-LEAD
Brand
TEBAOFLEX
Product overview

TF-IFL (North American 70–2,500 MCM) and TF-WCHC (European metric 95–2,000 mm²) water-cooled flexible power lead assemblies carry 950 A to 20,000 A between stationary power-supply manifolds and tilting coreless induction melting coils, vacuum-induction feedthroughs, graphitizing furnaces and polysilicon reduction reactors.

Every furnace tilt cycle bends and twists the flexible power leads while 50/60 Hz to 3,000 Hz alternating currents concentrate toward the outer conductor perimeter through skin and proximity effects. Solid-core ropes soldered into cast lugs suffer tin recrystallization and water-passage choking; TEBAOFLEX lays fine Cu-ETP / Cu-HCP copper ropes around a resilient self-flushing central water-channel core (including Center-Channel 95–500 mm² builds) and cold-presses them into CNC-machined oxygen-free copper heads under circumferential hydraulic compression.

Specify TF-IFL with female SAE 37° JIC swivel nuts (#8C to #32C) or O-ring vacuum plugs for foundry tilting melters; specify TF-WCHC Type A (standard) or Type B (with vulcanized intermediate support collars that prevent saddle clamps from pinching coolant flow) for 50/60 Hz vacuum, glass and non-ferrous furnaces; above 2 kHz or where ultra-low inductive reactance is critical, switch to TF-HC10K hollow-core enameled-Litz or TF-WCCX two-conductor coaxial leads. MOQ 2 pieces (1 pair) or 1 set, 7 to 45 working days.

Explore the high-temperature wire and cable range for related configurations.

Construction

TF-IFL & TF-WCHC Water-Cooled Power Lead Construction

Custom-built to approved terminal drawings using DIN EN 13601 / ASTM B187 high-conductivity copper heads, AISI 304/316 non-magnetic bands and 10 bar hydro-tested hoses.

Clean 2D circular engineering cross-section of TF-IFL water-cooled furnace power lead showing black reinforced rubber coolant hose, annular water flow space and 6 multi-strand copper ropes around a central hollow support core
Self-flushing annular water-cooled cross-section: 6 rope-lay copper bundles around a resilient hollow core inside a 6 bar / 15 kV dielectric coolant hose.
TF-IFL & TF-WCHC Induction Melting & Vacuum Furnace Water-Cooled Power Lead Cable (70–2,500 MCM / 35–2,000 mm²) construction
ComponentMaterial and construction
1. Rope-Lay High-Conductivity Copper around Central Coolant Channel100 % IACS soft-annealed Cu-ETP / oxygen-free Cu-HCP stranded ropes concentrically laid over an open spiral or resilient rubber water core for uniform 360-degree heat removal.
2. Solderless Hydraulically Pressed CNC Copper Terminal HeadsMachined from forged Cu-HCP bar (optional silver- or tin-plated contact palms) in flat 1–8 hole flags, 45°/90° elbows, offset repairable heads, or #8C–#32C 37° JIC female swivel nuts.
3. Electrically Insulating Cord-Reinforced EPDM / CR Coolant HoseFlame-retardant, ozone- and heat-resistant multi-ply elastomer hose (5 kV to 15 kV dielectric withstand; 6 bar working / 10 bar test / 18 bar burst) clamped with non-magnetic 304/316 stainless bands.
4. Optional Slag-Splash Pyrojacket & Type B Intermediate Clamping CollarsOptional silicone-fiberglass thermal sleeve (-T) for foundry pouring-spout splash protection, plus internal solid copper clamping rings (Type B) for long-span routing.

TF-IFL & TF-WCHC Model & Terminal Code Breakdown

  • TF-IFL-<MCM>: North American induction furnace water-cooled power lead (70 MCM to 2,500 MCM, JIC 37° swivel or NPT flat head)
  • TF-WCHC-<mm²>A: European metric 50/60 Hz water-cooled high-current cable Type A (120–1,000 mm², standard pressed Cu-HCP heads)
  • TF-WCHC-<mm²>B: Metric Type B build with internal solid clamping rings for intermediate saddle-clamp support on long spans
  • TF-WCHC-<mm²>C / M: Center-Channel hollow-core (95–500 mm²) or Multi-Conductor heavy foundry build (1,200–2,000 mm², up to 20 kA)
  • -T Suffix: Optional vulcanized or slip-on +500 °C iron-oxide silicone-fiberglass molten-splash thermal sleeve
Applications

TF-IFL Induction Melting, Vacuum, CVD & Glass Furnace Duty

Engineered as OEM-compatible replacement and new-build power leads for foundry melting, vacuum metallurgy, crystal growing and chemical furnaces.

Heavy black TF-IFL water-cooled flexible power lead assemblies with silver-plated CNC-machined copper terminal palms, stainless hose bands and brass coolant fittings bolted to copper busbars beside an induction melting furnace
Coreless induction melting furnace secondary busbars connected via custom-terminated TF-IFL water-cooled flexible power leads.
  • Coreless iron, steel, brass and aluminum tilting induction melting furnaces (50 Hz to 3,000 Hz coil feed leads up to 8,000–20,000 A).
  • Vacuum induction melting (VIM), vacuum arc remelting (VAR), plasma-hearth and directional-solidification investment-casting furnaces.
  • Polysilicon Siemens CVD bell-jar reactors, monocrystalline silicon Czochralski heaters, Acheson graphitizing furnaces and optical-glass melters.
  • High-current rectifier-to-busbar flexible transitions, resistance-heating bus jumpers and mobile transformer load-bank test leads.

TF-IFL / TF-WCHC vs 10 kHz Hollow-Core vs EAF Water-Cooled

TF-IFL / TF-WCHC (70–2,500 MCM) vs TF-HC10K / TF-WCCX (MF 2–10 kHz) vs EAF Water-Cooled (1,000–7,000 mm²)
Water-Cooled SeriesSection & FrequencyConductor & Head DesignTarget Furnace Equipment
TF-IFL & TF-WCHC (this page)35–2,000 mm² (70–2,500 MCM); 50 Hz–3 kHzBare/tinned copper ropes; JIC swivel, NPT or flat pressed Cu headsCoreless tilting induction melters, vacuum, CVD & glass furnaces
TF-HC2K / TF-HC10K & TF-WCCX70–1,015 mm² / 300–6,000 MCM; up to 10 kHzDouble-enameled hollow-core Litz or 2-pole coaxial low-reactance1–10 kHz billet heaters, hardening coils & low-voltage-drop MF links
EAF / LF Water-Cooled Cable1,000–7,000 mm²; 50/60 Hz (5–45 kA)Multi-rope 400/500 mm² strands + rotating swivel & slag bumpersSteelmaking Electric Arc Furnaces (EAF) & Ladle Furnaces (LF)
SAF High-Current Furnace Cable750–7,000 mm²; 50/60 HzRing-nut & heavy pressed palms for secondary copper bus-tubesSubmerged-Arc Furnaces (ferroalloy, silicon, calcium carbide)

Above 1,500–2,000 Hz on cables >= 300 mm², bare-strand skin effect triples AC losses (R_AC/R_DC > 3.0); upgrade to TF-HC10K enameled-wire hollow-core leads to cut kW heat loss.

TF-IFL & TF-WCHC Water-Cooled Lead Drawing & RFQ Checklist

  • Conductor cross-section (MCM or mm²), operating current (A), system voltage (V) and inverter frequency (Hz or kHz).
  • Exact overall assembly length measured hole-center to hole-center (or JIC flare seat to seat) in mm or inches.
  • End A and End B terminal configuration (flat palm hole pattern & rotational offset angle, #8C–#32C 37° JIC swivel nut, or O-ring vacuum flange) — attach sketch or existing OEM part reference.
  • Coolant port thread (1/4" to 1" NPT or G/BSPP, axial end port Pe vs side port Ps) and optional +500 °C splash pyrojacket (-T).
  • Required quantity in matched pairs or sets (MOQ 2 pieces / 1 pair or 1 furnace set, 7 to 45 working days).

Related selection resources

TF-IFL & TF-WCHC Induction Furnace Water-Cooled Lead FAQ

How do I measure the assembly length when ordering TF-IFL or TF-WCHC water-cooled furnace leads?

Always specify pin-to-pin overall length from bolt-hole center to bolt-hole center on flat palms, or from flare-seat to flare-seat on 37° JIC swivel leads—never measure only the black rubber hose, which is shorter than the full copper assembly.

What is the difference between TF-WCHC Type A and Type B water-cooled cables?

2 structural mounting designs separate them: Type A is a continuous flexible hose assembly supported solely at its two copper end heads, whereas Type B integrates solid internal copper clamping collars along the span so intermediate saddle brackets grip securely without pinching the coolant hose.

At what frequency should I switch from TF-IFL bare-copper leads to TF-HC10K enameled hollow-core leads?

Switch above 1.5 kHz to 2 kHz on cross-sections >= 250 mm² (500 MCM): Table 1 shows R_AC/R_DC rises to 3.69–5.60 at 3 kHz in bare stranded copper, whereas double-enameled hollow-core Litz in TF-HC10K suppresses skin effect up to 10 kHz.

What cooling water pressure, temperature and conductivity do TF-IFL and TF-WCHC leads require?

Operate at 2.5 to 6.0 bar (35 to 87 PSI) inlet pressure with outlet water temperature kept strictly below +65 °C (+150 °F); on induction coils operating above 600 V AC, maintain water conductivity below 20–30 μS/cm to prevent electrolytic copper head erosion.

What is the minimum order quantity and lead time for custom TF-IFL and TF-WCHC assemblies?

2 pieces (1 matched pair) or 1 complete furnace set custom-machined to your terminal drawing, 100 % hydro-tested at 10 bar and shipped in 7 to 45 working days.

Specifications

TF-IFL (MCM) & TF-WCHC (mm²) Electrical & Flow Schedule

TF-IFL & TF-WCHC Current, Pressure, Port & Pair MOQ Summary

  • 70–2,500 MCM & 95–2,000 mm² span: Bridges the exact foundry/vacuum furnace range below 7,000 mm² steelmaking EAF cables, covering 950 A desktop/tilting melters up to 20 kA mains bus links
  • JIC 37° swivel, flange & flat heads: Precision-machined Cu-HCP 99.95 % copper terminals with #8C–#32C SAE 37° flare swivel nuts, O-ring vacuum flanges, offset palms or intermediate Type B clamps
  • Verified skin-effect R_AC/R_DC data: Published 60 Hz, 1 kHz and 3 kHz AC/DC resistance multipliers prevent overheating when sizing leads between solid-state inverters and tilting induction coils
  • 10 bar hydro-tested 15 kV hose: Cord-reinforced non-conductive EPDM / CR coolant hoses (working pressure 6 bar, 100 % factory hydro-tested at 10 bar) with optional +500 °C splash pyrojacket
  • 2 pieces (1 pair) assembly MOQ: Manufactured to exact pin-to-pin or flare-to-flare drawing length from a 2 pieces (1 pair) or 1 furnace set minimum order in 7 to 45 working days
TF-IFL & TF-WCHC Induction Melting & Vacuum Furnace Water-Cooled Power Lead Cable (70–2,500 MCM / 35–2,000 mm²) technical data
ParameterValue
Rated voltageUp to 1000 V to 3000 V AC coil operating voltage with 5 kV to 15 kV dielectric insulating coolant hose
Cross-section and current span70 MCM to 2500 MCM (North American TF-IFL) and 95 mm2 to 2000 mm2 (Metric TF-WCHC), rated 950 A to 20000 A at 50/60 Hz
Terminal and water port stylesFlat 1 to 8 hole palms, 45/90 deg flags, SAE 37 deg JIC swivel nuts (#8C to #32C), and 1/4 in to 1 in NPT or BSPP axial/side water ports
Coolant pressure and exhaust limit6 bar (87 PSI) maximum continuous water pressure, 10 bar (145 PSI) factory hydro-test, maximum continuous water outlet temperature +65 C (+150 F)
Minimum order and lead time2 pieces (1 matched pair) or 1 furnace set built to approved length and terminal drawing in 7 to 45 working days
Water quality requirementClean closed-loop cooling water with inlet temperature +15 C to +32 C (low-conductivity treated water below 20 uS/cm recommended above 600 V)
Optional thermal armourVulcanized or slip-on iron-oxide silicone-fiberglass heat shield (-T) and rubber anti-chafing rings for pouring-deck splash zones

TF-IFL (70–2,500 MCM) Foundry Induction Power Lead Schedule

TF-IFL North American Induction Furnace Water-Cooled Power Leads (70 MCM to 2,500 MCM) — Electrical, Skin-Effect & Flow Schedule
Model & MCM SizeMetric Equiv. (mm²)Hose Nom. OD (mm / in)R_DC at 20 °C (μΩ/ft)R_AC / R_DC (60 Hz / 1 kHz / 3 kHz)Min. Water Flow (GPM)Standard Fitting / PortAssembly MOQNext step
TF-IFL-100 (100 MCM)50 mm²29 / 1.16103.71.00 / 1.22 / 1.902.0#10C JIC or Flat + 1/4 NPT2 pcs (1 pair)Request this size
TF-IFL-133 (133 MCM)67 mm²31 / 1.2278.01.00 / 1.28 / 2.042.0#12C JIC or Flat + 3/8 NPT2 pcs (1 pair)Request this size
TF-IFL-216 (216 MCM)109 mm²31 / 1.2248.01.00 / 1.56 / 2.522.0Flat Palm + 3/8 NPT2 pcs (1 pair)Request this size
TF-IFL-266 (266 MCM)135 mm²39 / 1.5640.01.01 / 1.71 / 2.774.0#16C JIC or Flat + 1/2 NPT2 pcs (1 pair)Request this size
TF-IFL-350 (350 MCM)177 mm²39 / 1.5629.61.01 / 1.92 / 3.134.0Flat Palm + 1/2 NPT2 pcs (1 pair)Request this size
TF-IFL-400 (400 MCM)203 mm²39 / 1.5625.91.01 / 2.04 / 3.334.0Flat Palm + 1/2 NPT2 pcs (1 pair)Request this size
TF-IFL-500 (500 MCM)253 mm²47 / 1.8820.71.02 / 2.25 / 3.694.0#20C JIC or Flat + 1/2 NPT2 pcs (1 pair)Request this size
TF-IFL-600 (600 MCM)304 mm²47 / 1.8817.31.03 / 2.44 / 4.014.0Flat Palm + 1/2 NPT2 pcs (1 pair)Request this size
TF-IFL-750 (750 MCM)380 mm²52 / 2.0613.81.04 / 2.69 / 4.456.0#24C JIC or Flat + 1/2 NPT2 pcs (1 pair)Request this size
TF-IFL-1000 (1000 MCM)507 mm²59 / 2.3410.41.07 / 2.88 / 5.106.0#32C JIC or Flat + 1/2 NPT2 pcs (1 pair)Request this size
TF-IFL-1200 (1200 MCM)608 mm²67 / 2.628.641.10 / 3.35 / 5.608.02-Hole Flag + 1/2 NPT2 pcs (1 pair)Request this size
TF-IFL-1500 (1500 MCM)760 mm²80 / 3.166.911.15 / 3.80 / —8.02/4-Hole Flag + 3/4 NPT2 pcs (1 pair)Request this size
TF-IFL-2500 (2500 MCM)1,267 mm²95 / 3.754.151.26 / — / —8.04-Hole Flag + 3/4 NPT2 pcs (1 pair)Request this size

TF-WCHC (95–2,000 mm²) Metric Mains & Vacuum Furnace Schedule

TF-WCHC European Metric Water-Cooled High-Current Cables (95 mm² to 2,000 mm²) — Type A, Type B & Center-Channel 50/60 Hz Schedule
Model & Cross-SectionDesign Architecture50/60 Hz Ref. Current (A)Palm Width × Thickness (mm)Coolant Thread (BSPP / G)Operating / Test PressureAssembly MOQNext step
TF-WCHC-95C (95 mm²)Center-Channel Hollow1,10025 × 12G 1/4"6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCHC-120A/B (120 mm²)Single-Rope Type A / B1,60025 × 10G 1/4"6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCHC-150C (150 mm²)Center-Channel Hollow1,50030 × 12G 3/8"6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCHC-185A/B (185 mm²)Single-Rope Type A / B2,50030 × 12G 3/8"6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCHC-300A/B (300 mm²)Single-Rope Type A / B3,70035 × 15G 3/8"6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCHC-400A/B (400 mm²)Single-Rope Type A / B4,50042 × 20G 3/8"6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCHC-500A/B (500 mm²)Single-Rope Type A / B5,50055 × 20G 3/8" or 1/2"6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCHC-750A/B (750 mm²)Single/Multi-Rope7,50055–65 × 22G 3/8" or 3/4"6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCHC-1000A/B (1,000 mm²)Single/Multi-Rope10,00070 × 25–30G 1/2" or 1"6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCHC-1200M (1,200 mm²)Multi-Conductor12,00080 × 30G 1"6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCHC-1600M (1,600 mm²)Multi-Conductor16,00090 × 35G 1"6 bar / 10 bar2 pcs (1 pair)Request this size
TF-WCHC-2000M (2,000 mm²)Multi-Conductor20,000100 × 35G 1"6 bar / 10 bar2 pcs (1 pair)Request this size

Thermal & flow sizing equations: Power Loss P (W) = I² × R_AC × L; Minimum Coolant Flow (GPM) = P / (268 × ΔT_°C) or Flow (L/min) = 0.0143 × P / ΔT_°C, keeping coolant outlet temperature <= +65 °C (+150 °F). Final palm drilling and thread geometry follow the approved quotation drawing.

ASCII part references for BOM and ERP entry: TF-IFL-266, TF-IFL-350, TF-IFL-500, TF-IFL-750, TF-IFL-1000, TF-IFL-1500, TF-IFL-2500, TF-WCHC-300A, TF-WCHC-500A, TF-WCHC-750B, TF-WCHC-1000A, TF-WCHC-1600M, TF-WCHC-2000M.

Standards

TF-IFL & TF-WCHC Reference Standards (EN 13601 & SAE J514)

TF-IFL & TF-WCHC Induction Melting & Vacuum Furnace Water-Cooled Power Lead Cable (70–2,500 MCM / 35–2,000 mm²) standards and test references
Standard or specificationApplication
DIN EN 13601 & ASTM B187 / EN 13602High-conductivity oxygen-free Cu-HCP / ETP copper bar for machined terminal palms and fine-drawn annealed copper wire ropes.
SAE J514 (37° JIC Flare), ANSI/ASME B1.20.1 (NPT) & ISO 228-1 (G/BSPP)Leak-tight hydraulic/coolant swivel flare, tapered NPT and parallel BSPP water-port thread geometry; 100 % hydro-tested at 10 bar.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and 10 bar hydro-test / micro-ohm inspection

ASTM B187 — Standard Specification for Copper Bar, Bus Bar, Rod and Shapes

SAE J514 — 37-Degree Flared Hydraulic & Coolant Tube Fittings

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.