TF-SHUNT Press-Welded Laminated Copper Shunts & Heavy Flat Braided Busbar Expansion Connectors (100–4,500 mm²)
TF-SHUNT and TF-SHUNT-BR (TF-SHUNT-BUSBAR) are high-current flexible copper busbar expansion connectors and welding shunts spanning 100 mm² to 4,500 mm² (450 A to 6,500 A). Manufactured as solid-state polymer-diffusion press-welded 0.10–0.20 mm Cu-ETP / Cu-OF copper foil laminated shunts (zero filler metal) or multi-layer flat braided copper jumpers with seamless pressed palms.
TF-SHUNT diffusion-press-welded laminated copper foil shunts (100–3,200 mm²) and TF-SHUNT-BR multi-layer flat braided copper busbar expansion jumpers (120–4,500 mm²) carry 450 A to 6,500 A per connector across rigid copper/aluminum busbar joints that expand thermally, vibrate at 100/120 Hz or cycle linearly on resistance-welding platens.
Bolting rigid secondary copper bars directly onto transformer bushings, rectifier diodes or furnace bus-tubes transfers thousands of Newtons of thermal-expansion thrust that cracks insulators and loosens bolts, while riveted or tin-soldered foil packs overheat and delaminate under fault currents. TEBAOFLEX stacks dozens of 0.10 mm or 0.20 mm soft Cu-ETP / oxygen-free Cu-OF copper ribbons and fuses both contact palms under high electric current and hydraulic pressure without any foreign filler metal—creating a 100 % pure copper grain-boundary weld with the same conductivity as solid bar.
Specify press-welded laminated TF-SHUNT (with U-arch, Omega-loop or S-offset expansion bends) for ultra-compact linear expansion and hinge-axis spot-welding gun platens; specify flat braided TF-SHUNT-BR (Ø 0.15–0.20 mm braided copper tapes cold-pressed in seamless E-copper ferrules, up to 4,500 mm²) when multi-directional vibration or slight lateral misalignment occurs; for full 360-degree robotic torsion, switch to round TF-ACC or TF-ACHC ropes. MOQ 5 pcs per drawing, 7 to 45 working days.
Explore the heavy-duty industrial cable range for related configurations.
TF-SHUNT Diffusion Press-Welded & Flat Braid Construction
Engineered to DIN EN 13600 / 13601 high-conductivity copper standards using filler-free solid-state diffusion press welding and cold-forged seamless ferrules.

| Component | Material and construction |
|---|---|
| 1. Stacked 0.10–0.20 mm Cu-ETP / Cu-OF Foils or Flat Copper Braids | Soft-annealed 99.90 % Cu-ETP or 99.95 % oxygen-free Cu-OF foils (mandatory for high-heat diffusion welding without hydrogen embrittlement), or tubular/flat Ø 0.15–0.20 mm copper braids. |
| 2. Solid-State Press-Welded Ends or Cold-Pressed Seamless Ferrules | Homogeneous filler-free diffusion-welded contact blocks on TF-SHUNT, or high-tonnage solderless-crimped E-copper contact sleeves on TF-SHUNT-BR. |
| 3. CNC-Milled & Punched Bolt Patterns + Tin / Silver / Nickel Plating | Flat-milled contact faces drilled or slotted to NEMA (2-hole / 4-hole / 6-hole) or DIN busbar templates; optional tin, silver or nickel electroplating. |
| 4. Optional Mid-Span PVC, Silicone, Shrink or Mica Insulation | Dip-molded PVC (+105 °C), extruded silicone sleeve (+180 °C) or halogen-free polyolefin shrink insulation over the flexible expansion zone. |
TF-SHUNT Foil & TF-SHUNT-BR Flat Braid Breakdown
- TF-SHUNT-<mm²>: Solid-state polymer-diffusion press-welded flexible copper foil laminated shunt (100 mm² to 3,200 mm², zero filler)
- TF-SHUNT-BR-<mm²>: Multi-layer flat braided Cu-ETP copper expansion jumper with cold-pressed seamless E-copper palms (150–4,500 mm²)
- Cu-OF (CW008A): 99.95 % oxygen-free copper foil ensuring embrittlement-free molecular fusion in solid-state press-welded palms
- -SN / -AG / -NI: Electro-tinned (-SN), silver-plated (-AG) or nickel-plated (-NI) contact surfaces
- -PVC / -SI: Optional dip-molded PVC (+105 °C) or extruded silicone (+180 °C) mid-span protective insulation
TF-SHUNT Furnace Transformers, Weld Platens & Switchgear
Built for high-ampere busbar expansion, transformer decoupling, electrolysis cell rooms and stationary resistance-welding machines.

- Electric arc furnace (EAF), ladle furnace (LF) and submerged-arc furnace (SAF) LV transformer riser-to-bus-tube thermal expansion joints.
- Stationary spot, projection, seam and flash-butt welding machine secondary knees, lower platens and pneumatic cylinder electrode holders.
- Chlor-alkali, copper, zinc and aluminum smelter DC busbar expansion compensators and cell-bypass shorting switches.
- LV/MV switchgear, busduct building-expansion joints, generator phase-isolated bus links and EV battery pack high-current laminated busbars.
TF-SHUNT Press-Welded Foil vs Flat Braid vs Round Rope
| Busbar Connector Type | End Joint Metallurgy | Motion Envelope | Why Specify / Avoid |
|---|---|---|---|
| TF-SHUNT Press-Welded Foil (this page) | 100% pure Cu solid-state diffusion weld | Linear expansion & single-plane bend | Lowest contact mV drop & smallest envelope for rigid busbars |
| TF-SHUNT-BR Flat Braid (this page) | High-tonnage cold-pressed seamless ferrule | 3-axis vibration + lateral offset | Best where transformer hum & multi-axis misalignment coincide |
| Riveted / Tin-Soldered Foil Packs | Mechanical rivet or Sn/Pb solder | Linear expansion only | Avoid above 1,000 A: solder melts under fault & gaps oxidize |
| TF-ACHC / TF-ACC Round Rope | Cold-swaged tubular palm | Full 360° 3D bend + axial torsion | Mandatory when robotic arms or furnace doors twist out of plane |
Never twist a laminated foil shunt (TF-SHUNT) axially around its longitudinal axis—outer foil edges buckle and tear; if both ends do not lie in parallel planes, specify TF-SHUNT-BR flat braids or TF-ACHC round ropes.
TF-SHUNT Laminated Shunt & Busbar Jumper RFQ Checklist
- Connector type: press-welded laminated copper foil (TF-SHUNT) or multi-layer flat braided copper (TF-SHUNT-BR).
- Width × thickness (mm), total cross-section (mm²), continuous current (A) and required expansion travel (±mm).
- Overall length, contact palm lengths on both ends, central U-arch / Z-offset profile and bolt-hole pattern (attach drawing or PDF).
- Surface plating (uncoated, tin-plated, silver-plated or nickel-plated) and optional mid-span PVC/silicone/shrink insulation.
- Quantity per drawing (MOQ 5 pcs per specification, 7 to 45 working days).
Related selection resources
- Browse all Flexible Copper Busbar Connectors & Industrial Cables
- Compare TF-ACHC Ø 0.10 mm Round-Stranded High-Current Copper Connectors
- Compare TF-ACC Robotic Resistance-Welding Air-Cooled Jumper Cable
- Pair with EAF Water-Cooled Secondary Furnace Cable (1,000–7,000 mm²)
- Pair with SAF Submerged-Arc Furnace Water-Cooled Secondary Cable
- Engineering guide: Tin vs silver vs bare copper busbar interface selection
TF-SHUNT Press-Welded Laminated Copper Shunt FAQ
Why are solid-state press-welded TF-SHUNT connectors superior to soldered or brazed copper shunts?
Zero foreign filler metal: polymer-diffusion press welding fuses the 0.10–0.20 mm Cu-OF foils directly together under pressure and current without tin solder or silver-phosphorus braze—preventing solder melt-out during short-circuit faults and eliminating brittle braze-wicking zones.
When should I choose laminated foil TF-SHUNT versus flat braided TF-SHUNT-BR?
Choose laminated foil TF-SHUNT when maximum current must fit inside the tightest flat height and motion is strictly linear expansion or single-axis hinge flexing; choose flat braided TF-SHUNT-BR when 3-axis transformer vibration or lateral busbar misalignment is present.
Can TF-SHUNT connect copper transformer risers directly to aluminum busbars?
Yes — order TF-SHUNT or TF-SHUNT-BR with electro-tinned (or silver-plated) contact palms, which prevent bimetallic galvanic corrosion at bolted aluminum-to-copper busbar interfaces.
Why is it better to install two parallel 500 mm² TF-SHUNT shunts instead of one 1,000 mm² shunt?
35 % to 40 % higher ampacity for the same copper weight: Table 1 shows two parallel TF-SHUNT-500 shunts spaced 8–10 mm apart carry 2,280 A (versus ~1,650 A for a single 100×10 mm solid-equivalent pack) because cooling air rises freely between the inner faces.
What is the minimum order quantity and manufacturing lead time for custom TF-SHUNT drawings?
5 pcs per drawing specification, press-welded, CNC-milled/punched and shipped in 7 to 45 working days.
TF-SHUNT (100–3,200 mm²) & TF-SHUNT-BR (up to 4,500 mm²) Schedule
TF-SHUNT Foil Gauge, Plating, Ampacity & 5-Pc MOQ Summary
- Filler-free diffusion press-welded: Molecular solid-state press welding fuses 0.10–0.20 mm Cu-ETP or oxygen-free Cu-OF foils into monolithic solid ends with zero solder or brazing resistance
- Laminated foil + flat braid lines: Choose ultra-compact U/V/Z-formed laminated shunts (TF-SHUNT, 100–3,200 mm²) for linear travel, or flat braided copper straps (TF-SHUNT-BR, up to 4,500 mm²) for 3-axis vibration
- Furnace, switchgear & weld platens: Absorbs thermal growth on EAF/SAF furnace transformer bus-tubes, electrolysis cell shorting switches, MV/LV switchgear and stationary spot-welding platens
- Bare, tin, silver or mid-insulated: Available with uncoated, electro-tinned, silver-plated or nickel-plated palms and optional PVC, silicone or heat-shrink mid-span insulation
- 5 pcs per drawing MOQ: Custom-punched, CNC-milled and formed to exact customer busbar bolt patterns from 5 pcs MOQ in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | Uninsulated busbar system voltage up to 36 kV (with air clearance), or 1000 V AC / 1500 V DC on PVC/silicone mid-span insulated shunts |
| Cross-section and current span | Laminated foil TF-SHUNT: 100 mm2 to 3200 mm2 (450 A to 4600 A); Flat braided TF-SHUNT-BR: 120 mm2 to 4500 mm2 (450 A to 6500 A) |
| Foil and wire thickness | 0.10 mm ultra-flex (welding guns and switchgear), 0.15 to 0.20 mm standard expansion shunts, or 0.15 to 0.20 mm braided Cu-ETP wires |
| Contact palm metallurgy | 100% filler-free solid-state diffusion press-welded Cu-OF / Cu-ETP ends, or solderless cold-pressed seamless E-copper ferrules |
| Minimum order and lead time | 5 pcs per specification or customer drawing, CNC-machined and delivered in 7 to 45 working days |
| Surface finish options | Bright uncoated copper, electro-tinned (anti-corrosion / Al-bus transition), silver-plated (lowest mV drop) or nickel-plated (+250 C) |
| Expansion geometry | Straight flat, single central U-arch, double Omega expansion wave, 90-degree L-bend or Z-offset step |
TF-SHUNT (100–3,200 mm²) Press-Welded Laminated Shunt Schedule
| Model & Cross-Section | Width × Foil Stack Thickness (mm) | Foil Gauge × Leaves | Single Shunt Current ΔT 30 / 50 K (A) | 2-Shunt Pair Current ΔT 50 K (A) | Standard NEMA / DIN Holes | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|
| TF-SHUNT-100 (100 mm²) | 25 × 4.0 | 0.10 mm × 40 | 350 / 460 | 780 | 1 or 2 × Ø9 / Ø11 | 5 pcs | Request this size |
| TF-SHUNT-160 (160 mm²) | 32 × 5.0 | 0.10 mm × 50 | 480 / 630 | 1,070 | 1 or 2 × Ø11 / Ø13 | 5 pcs | Request this size |
| TF-SHUNT-250 (250 mm²) | 40 × 6.25 | 0.10 mm × 62 | 650 / 850 | 1,440 | 2 × Ø13 (M12) | 5 pcs | Request this size |
| TF-SHUNT-300 (300 mm²) | 50 × 6.0 | 0.10 mm × 60 | 760 / 1,000 | 1,700 | 2 × Ø13 / Ø14 | 5 pcs | Request this size |
| TF-SHUNT-400 (400 mm²) | 50 × 8.0 | 0.10 mm × 80 | 900 / 1,180 | 2,000 | 2 × Ø14 (M12) | 5 pcs | Request this size |
| TF-SHUNT-500 (500 mm²) | 50 × 10.0 | 0.10 mm × 100 | 1,020 / 1,340 | 2,280 | 2 or 4 × Ø14 | 5 pcs | Request this size |
| TF-SHUNT-600 (600 mm²) | 60 × 10.0 | 0.10 mm × 100 | 1,180 / 1,550 | 2,630 | 4 × Ø14 (M12) | 5 pcs | Request this size |
| TF-SHUNT-800 (800 mm²) | 80 × 10.0 | 0.10 mm × 100 | 1,490 / 1,960 | 3,330 | 4 × Ø14 (M12) | 5 pcs | Request this size |
| TF-SHUNT-1000 (1,000 mm²) | 100 × 10.0 | 0.10 mm × 100 | 1,800 / 2,360 | 4,010 | 4 × Ø14 or Ø18 | 5 pcs | Request this size |
| TF-SHUNT-1200 (1,200 mm²) | 100 × 12.0 | 0.15 mm × 80 | 2,010 / 2,640 | 4,480 | 4 × Ø14 or Ø18 | 5 pcs | Request this size |
| TF-SHUNT-2000 (2,000 mm²) | 120 × 16.7 | 0.20 mm × 83 | 2,750 / 3,600 | 6,100 | 6 × Ø18 (M16) | 5 pcs | Request this size |
| TF-SHUNT-3200 (3,200 mm²) | 160 × 20.0 | 0.20 mm × 100 | 3,550 / 4,650 | 7,850 | 8 × Ø18 (M16) | 5 pcs | Request this size |
TF-SHUNT-BR (150–4,500 mm²) Flat Braided Busbar Jumper Schedule
| Model & Cross-Section | Flat Braid Layers × Width (mm) | Pressed Palm Thickness (mm) | Single Jumper Current ΔT 50 K (A) | Flex Axes | Typical Busbar Duty | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|
| TF-SHUNT-BR-150 (150 mm²) | 2 × 30 mm braids | 9.5 | 610 | 3-Axis Vibration | Transformer LV stud decoupling | 5 pcs | Request this size |
| TF-SHUNT-BR-300 (300 mm²) | 3 × 40 mm braids | 13.0 | 980 | 3-Axis Vibration | Switchgear & busduct joint | 5 pcs | Request this size |
| TF-SHUNT-BR-500 (500 mm²) | 4 × 50 mm braids | 16.5 | 1,380 | 3-Axis Vibration | Rectifier & BESS DC bus link | 5 pcs | Request this size |
| TF-SHUNT-BR-800 (800 mm²) | 4 × 80 mm braids | 18.0 | 1,980 | 3-Axis Vibration | Electrolysis cell bus jumper | 5 pcs | Request this size |
| TF-SHUNT-BR-1200 (1,200 mm²) | 6 × 80 mm braids | 24.0 | 2,650 | 3-Axis Vibration | Furnace transformer delta link | 5 pcs | Request this size |
| TF-SHUNT-BR-2000 (2,000 mm²) | 8 × 100 mm braids | 30.0 | 3,650 | 3-Axis Vibration | EAF / SAF bus-tube compensator | 5 pcs | Request this size |
| TF-SHUNT-BR-3000 (3,000 mm²) | 10 × 120 mm braids | 36.0 | 4,850 | 3-Axis Vibration | Heavy smelter DC bus riser | 5 pcs | Request this size |
| TF-SHUNT-BR-4500 (4,500 mm²) | 12 × 150 mm braids | 44.0 | 6,500 | 3-Axis Vibration | Ultra-high-current furnace bus | 5 pcs | Request this size |
Spacing & air-gap advantage: mounting 2, 3 or 4 thinner TF-SHUNT connectors in parallel with a 6–10 mm air gap between shunts dissipates 35–50 % more heat via chimney convection than a single thick shunt of identical total copper area. Final U-arch height, palm length and hole pattern follow your approved drawing.
ASCII part references for BOM and ERP entry: TF-SHUNT-160, TF-SHUNT-250, TF-SHUNT-400, TF-SHUNT-600, TF-SHUNT-800, TF-SHUNT-1000, TF-SHUNT-2000, TF-SHUNT-3200, TF-SHUNT-BR-300, TF-SHUNT-BR-500, TF-SHUNT-BR-1200, TF-SHUNT-BR-3000, TF-SHUNT-BR-4500.
TF-SHUNT Reference Standards (DIN EN 13599, ASTM B152 & DIN 43671)
| Standard or specification | Application |
|---|---|
| DIN EN 13599 & ASTM B152 Oxygen-Free / ETP Copper Foil | High-purity Cu-OF (CW008A, >= 99.95 % Cu) and Cu-ETP (CW004A) copper strip enabling oxide-free molecular diffusion press welding. |
| DIN 43671 & IEC 61439-1 Busbar Thermal Rise & Short-Circuit Duty | ΔT 30 K / 50 K continuous current rating methodology and bolted contact-pressure geometry. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and micro-ohm diffusion-weld inspection
ASTM B152 — Standard Specification for Copper Sheet, Strip, Plate, and Rolled Bar
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-ACHC Air-Cooled High-Current Flexible Stranded Copper Connector Cable (70–1,000 mm², Bare, Insulated & +800 °C Pyrojacketed)
A related cable option for a different application or duty profile.
View productTF-ACC Air-Cooled Resistance Welding Jumper Cable — 150–850 mm² (ACC Series) & 400–2,000 MCM Secondary Leads
A related cable option for a different application or duty profile.
View productEAF & Ladle Furnace (LF) Water-Cooled Cable — 1,000–7,000 mm² Fluted-Core, Bumper & Swivel Secondary Leads
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.