TF-ACHC Air-Cooled High-Current Flexible Stranded Copper Connector Cable (70–1,000 mm², Bare, Insulated & +800 °C Pyrojacketed)
TF-ACHC (TF-ACHC-CONN) is a solderless-pressed air-cooled high-current flexible round-stranded copper connector assembly spanning 70 mm² to 1,000 mm² (300 A to 1,800 A continuous). Manufactured from ultra-fine Ø 0.10 mm soft-annealed Cu-ETP1 wires with seamless E-copper contact palms in bare, PVC/silicone-insulated, or +800 °C calcium-silicate + +300 °C silicone fire-protected furnace builds.
TF-ACHC air-cooled high-current flexible copper connector cables decouple mechanical vibration, structural settling and thermal busbar expansion across 70 mm² to 1,000 mm² (300 A to 1,800 A per lead; up to 3,600 A in back-to-back busbar pairs) in industrial furnaces, rectifiers, switchgear, wind-turbine nacelles and electrolysis cell rooms.
Standard IEC Class 5 power cables (Ø 0.40–0.50 mm strands) are too stiff for short 200–1,500 mm busbar transitions and transmit destructive bending moments onto transformer studs and load cells, while flat foil shunts cannot twist out of plane. TF-ACHC ropes ultra-fine Ø 0.10 mm DIN EN 13602 ETP1 copper filaments (Ø 0.30 mm optional for heavy outdoor stiffness) and cold-presses seamless E-copper tubes into precision flat contact palms without solder.
Specify uninsulated TF-ACHC-U for maximum convective ampacity inside ventilated busbar ducts; specify PVC- or silicone-insulated TF-ACHC-I for touch/phase clearance (apply a 15–20 % enclosure thermal derating); specify fire-protected TF-ACHC-FP (inner +800 °C / +1,100 °C peak calcium-silicate yarn hose + outer +300 °C / +500 °C peak silicone cover) beside melting furnaces and ladle cars; above 2,000 A in compact furnace delta closures, switch to TF-WCHC water-cooled cables. MOQ 5 pcs per specification, 7 to 45 working days.
Explore the heavy-duty industrial cable range for related configurations.
TF-ACHC Ø 0.10 mm Stranded Copper & Fire-Hose Design
Manufactured from DIN EN 13602 soft-annealed ETP1 round-stranded copper ropes and seamless cold-pressed E-copper tubular contact palms.

| Component | Material and construction |
|---|---|
| 1. Ultra-Flexible Round-Stranded Cu-ETP1 Conductor (Ø 0.10 mm) | Uncoated or tinned Ø 0.10 mm soft-annealed electrolytic copper wires (optional Ø 0.30 mm wire build) delivering multi-directional vibration isolation. |
| 2. Solderless Cold-Pressed Seamless E-Copper Contact Palms | Uncoated, tin-plated, silver-plated or nickel-plated rectangular contact areas (with standard neck bend-relief) in Type A (2-hole / 4-hole) or Type C (1-hole lug) profiles. |
| 3. Bare, PVC (+70 °C), Silicone (+180 °C) or Polyolefin Insulation | Optional flexible insulating sleeve over the mid-span rope for phase-to-phase and earth clearance inside compact LV/MV cabinets. |
| 4. Optional +800 °C Calcium-Silicate / +300 °C Silicone Fire Hose (-FP) | Non-flammable inner calcium-silicate yarn tube (+800 °C continuous, +1,100 °C short-term) jacketed in self-extinguishing silicone (+300 °C continuous, +500 °C splash). |
TF-ACHC Uninsulated, Insulated & -FP Code Breakdown
- TF-ACHC-<mm²>: Air-cooled high-current flexible round-stranded copper connector (70 mm² through 1,000 mm², Ø 0.10 mm wire)
- -U / -PVC / -SI: Uninsulated bare copper (-U), flexible PVC hose (-PVC, +70 °C) or extruded silicone sleeve (-SI, +180 °C)
- -FP (Fire-Protected): +800 °C inner calcium-silicate yarn hose + +300 °C (+500 °C splash) outer silicone fire-protection sleeve
- Type A vs Type C: Extended 2/4-hole rectangular contact palm with bend-relief (Type A) vs compact 1-hole lug palm (Type C)
- -SN / -AG / -NI: Tin-plated (-SN), silver-plated (-AG) or nickel-plated (-NI) seamless pressed E-copper contact palms
TF-ACHC Furnace Busbars, Rectifiers, Electrolyzers & BESS
Engineered for high-current flexible electrical connections in furnaces, transformers, rectifiers, switchgear, rail traction and renewable energy.

- Electric melting, holding, heat-treatment and glass-furnace dry secondary busbar and heating-electrode flexible jumpers (TF-ACHC-FP).
- Chlor-alkali, copper/zinc electrowinning, aluminum and green-hydrogen electrolyzer rectifier-to-busbar expansion connectors.
- Low- and medium-voltage transformer bushings, generator circuit breakers, busduct seismic joints and load-cell weighed hopper/furnace leads.
- Wind-turbine converter cabinets, grid battery-storage (BESS) DC bus links and high-current test-bench interconnects.
TF-ACHC Round Rope vs Laminated Shunt vs Water-Cooled
| High-Current Connector | Geometry & Filament | Flex Freedom & Thermal Limit | Primary Application |
|---|---|---|---|
| TF-ACHC / TF-ACHC-FP (this page) | Round rope; Ø 0.10 mm Cu-ETP1 | 360° 3D flex + optional +800/+300 °C fire hose | Furnace electrodes, weighed hoppers, switchgear & rectifiers |
| TF-SHUNT Laminated / Braid | Flat stack (0.1 mm foil) or flat braid | Minimal height between parallel rigid busbars | Transformer LV riser expansion joints & electrolysis cells |
| TF-ACC Welding Jumper | Round rope; Ø 0.15–0.20 mm + PWIS hose | High-cycle torsional flex for spot-welding guns | Automotive BIW servo spot-welding gun secondary shunts |
| TF-WCHC Water-Cooled Cable | Hollow/annular rope + 6 bar water | Up to 20,000 A in 1/4 the copper cross-section | Induction, vacuum & reduction furnaces above 1,800–3,000 A |
Connecting onto precision load-cell weighed furnaces or hoppers? Specify Ø 0.10 mm uninsulated or thin-silicone TF-ACHC so cable spring stiffness does not distort weighing accuracy.
TF-ACHC High-Current Copper Connector RFQ Checklist
- Cross-section (70 mm² to 1,000 mm²) and continuous / peak current load (A).
- Mid-span covering: uninsulated (-U), PVC (-PVC), extruded silicone (-SI), or +800/+300 °C calcium-silicate fire sleeve (-FP).
- Overall center-to-center or end-to-end length (mm) and palm drilling (2-hole / 4-hole Type A, 1-hole Type C, or custom drawing).
- Contact palm surface finish: uncoated bright copper, tin-plated, silver-plated or nickel-plated (+250 °C+ furnace studs).
- Order quantity per configuration (MOQ 5 pcs per specification, 7 to 45 working days).
Related selection resources
- Browse all High-Current Copper Connectors & Heavy Industrial Cables
- Compare TF-SHUNT Press-Welded Laminated Copper Shunts & Flat Braids
- Compare TF-ACC Robotic Resistance-Welding Air-Cooled Jumper Cable
- Upgrade to TF-IFL & TF-WCHC Water-Cooled High-Current Cables (up to 20 kA)
- Pair with TF-PYRO-SM Multi-Core Slag-Resistant Furnace Control Cable
- Engineering guide: Bare vs tinned vs plated copper corrosion & contact physics
TF-ACHC Air-Cooled High-Current Copper Connector FAQ
Why does TF-ACHC use Ø 0.10 mm copper wires instead of standard IEC Class 5 (Ø 0.40–0.50 mm) stranding?
0.10 mm filaments have 16× to 25× lower individual bending stiffness than 0.40–0.50 mm wires, allowing short 200–800 mm high-current jumpers to flex effortlessly in all three axes without transferring vibration or thermal-expansion forces onto fragile ceramic bushings.
How much current derating applies when adding PVC, silicone or a +800 °C fire sleeve to TF-ACHC?
15 % to 20 % current reduction applies compared with bare uninsulated copper in +35 °C free air (for example TF-ACHC-500 drops from 1,100 A bare to 925 A fire-protected) because the thermal sleeve slows convective heat dissipation.
What temperatures can the TF-ACHC-FP fire-protection hose withstand near melting furnaces?
+300 °C continuous (+500 °C short-term molten splash) on the outer self-extinguishing silicone skin, backed by a non-flammable inner calcium-silicate yarn sleeve rated up to +800 °C continuous and +1,100 °C brief flame exposure.
Should I order tin-, silver- or nickel-plated contact palms on TF-ACHC connectors?
Choose tin plating for humid/chemical switchgear and aluminum-to-copper busbar joints; choose silver plating for lowest contact resistance above 1,000 A; and choose nickel plating whenever furnace busbar stud temperatures exceed +180 to +200 °C.
What is the minimum order quantity and lead time for custom TF-ACHC copper connectors?
5 pcs per specification (cross-section, length, sleeve type and palm drilling), cold-pressed and delivered in 7 to 45 working days.
TF-ACHC (70–1,000 mm²) & TF-ACHC-FP (+800 °C) Schedule
TF-ACHC Current, Thermal Sleeve, Palm & 5-Pc MOQ Summary
- Ultra-fine Ø 0.10 mm Cu-ETP1 wire: Thousands of Ø 0.10 mm soft-annealed copper filaments absorb transformer hum, breaker shock and multi-axis thermal expansion without transmitting force to porcelain bushings
- Bare, insulated or +800 °C fire hose: Supplied uninsulated for maximum air convection, PVC/silicone-sleeved for switchgear, or dual-wall +800 °C calcium-silicate / +300 °C silicone pyrojacketed (-FP)
- Solderless pressed E-copper palms: Seamless Cu-ETP tubular contact ends cold-forged without solder in rectangular busbar palms (Type A) or opposing-mount lug palms (Type C)
- 300 A to 1,800 A per single lead: Verified single-lead free-air current ratings (and parallel pair mounting on one busbar) across 70 mm² through 1,000 mm² cross-sections
- 5 pcs per specification MOQ: Custom-fabricated to exact customer length, bolt drilling and tin/silver/nickel contact plating from 5 pcs MOQ in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | Up to 1000 V AC / 1500 V DC on PVC or silicone insulated builds (uninsulated builds follow busbar clearance) |
| Cross-section and current span | 70, 95, 120, 150, 185, 240, 300, 400, 500, 600, 700, 750, 850 and 1000 mm2; 300 A to 1800 A single free-air rating |
| Insulation and thermal tiers | Uninsulated bare copper, PVC (+70 C), extruded silicone (+180 C), or Fire-Protection hose (+800 C inner calcium-silicate / +300 C outer silicone) |
| Contact palm and plating | Solderless pressed E-copper palms (Type A rectangular or Type C lug-shaped for dual-side bar mounting); bare, tin-, silver- or nickel-plated |
| Minimum order and lead time | 5 pcs per specification (cross-section, hole-to-hole length, insulation and palm drilling), delivered in 7 to 45 working days |
| Reference thermal basis | Single free-air laying at +35 C ambient and +70 C conductor temperature (apply 15% to 20% reduction on PVC/silicone/fire-hose insulated builds) |
| Single-wire filament gauge | 0.10 mm ultra-flexible standard (0.07 mm instrument or 0.30 mm heavy-duty filament diameter available to order) |
TF-ACHC (70–1,000 mm²) Bare & Insulated Copper Connector Schedule
| Model & Cross-Section | Uninsulated Current +35/+70 °C (A) | Insulated Ref. Current (A) | Type A Palm Length A × Width B (mm) | Bolt Hole ØD (mm) | Rope Nom. Ø (mm) | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|
| TF-ACHC-70 (70 mm²) | 300 | 250 | 30 × 15 | 7.0 (M6) | 12.5 | 5 pcs | Request this size |
| TF-ACHC-95 (95 mm²) | 360 | 300 | 40 × 20 | 9.0 (M8) | 14.5 | 5 pcs | Request this size |
| TF-ACHC-120 (120 mm²) | 420 | 350 | 40 × 20 | 9.0 (M8) | 16.5 | 5 pcs | Request this size |
| TF-ACHC-150 (150 mm²) | 480 | 400 | 50 × 25 | 11.0 (M10) | 18.5 | 5 pcs | Request this size |
| TF-ACHC-185 (185 mm²) | 570 | 475 | 50 × 25 | 11.0 (M10) | 20.5 | 5 pcs | Request this size |
| TF-ACHC-240 (240 mm²) | 670 | 570 | 60 × 32 | 11.0 (M10) | 23.5 | 5 pcs | Request this size |
| TF-ACHC-300 (300 mm²) | 780 | 650 | 80 × 40 | 14.0 (M12) | 26.5 | 5 pcs | Request this size |
| TF-ACHC-400 (400 mm²) | 950 | 800 | 80 × 40 | 14.0 (M12) | 30.5 | 5 pcs | Request this size |
| TF-ACHC-500 (500 mm²) | 1,100 | 925 | 80 × 40 | 14.0 (M12) | 34.5 | 5 pcs | Request this size |
| TF-ACHC-600 (600 mm²) | 1,250 | 1,050 | 80 × 55 | 14.0 (M12) | 38.5 | 5 pcs | Request this size |
| TF-ACHC-750 (750 mm²) | 1,450 | 1,225 | 80 × 55 | 14.0 (M12) | 43.0 | 5 pcs | Request this size |
| TF-ACHC-850 (850 mm²) | 1,550 | 1,310 | 80 × 55 | 14.0 (M12) | 46.0 | 5 pcs | Request this size |
| TF-ACHC-1000 (1,000 mm²) | 1,800 | 1,520 | 80 × 55–60 | 14.0 (M12/M16) | 50.0 | 5 pcs | Request this size |
TF-ACHC-FP (+800 °C / +300 °C) Fire-Protected Furnace Schedule
| Model & Cross-Section | Fire-Sleeve Current Load (A) | Inner / Outer Thermal Limit | Lug-Shaped Palm A1 × B (mm) | Standard Drilling | Splash & Flame Duty | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|
| TF-ACHC-FP-70 (70 mm²) | 250 | +800 °C / +300 °C (+1,100 °C peak) | 50 × 15 | Type A or C (Ø7) | Open flame & metal splash | 5 pcs | Request this size |
| TF-ACHC-FP-95 (95 mm²) | 300 | +800 °C / +300 °C (+1,100 °C peak) | 70 × 20 | Type A or C (Ø9) | Open flame & metal splash | 5 pcs | Request this size |
| TF-ACHC-FP-120 (120 mm²) | 350 | +800 °C / +300 °C (+1,100 °C peak) | 70 × 20 | Type A or C (Ø9) | Open flame & metal splash | 5 pcs | Request this size |
| TF-ACHC-FP-150 (150 mm²) | 400 | +800 °C / +300 °C (+1,100 °C peak) | 80 × 25 | Type A or C (Ø11) | Open flame & metal splash | 5 pcs | Request this size |
| TF-ACHC-FP-185 (185 mm²) | 475 | +800 °C / +300 °C (+1,100 °C peak) | 80 × 25 | Type A or C (Ø11) | Open flame & metal splash | 5 pcs | Request this size |
| TF-ACHC-FP-240 (240 mm²) | 570 | +800 °C / +300 °C (+1,100 °C peak) | 90 × 32 | Type A or C (Ø11) | Open flame & metal splash | 5 pcs | Request this size |
| TF-ACHC-FP-300 (300 mm²) | 650 | +800 °C / +300 °C (+1,100 °C peak) | 135 × 40 | Type A or C (Ø14) | Open flame & metal splash | 5 pcs | Request this size |
| TF-ACHC-FP-400 (400 mm²) | 800 | +800 °C / +300 °C (+1,100 °C peak) | 135 × 40 | Type A or C (Ø14) | Open flame & metal splash | 5 pcs | Request this size |
| TF-ACHC-FP-500 (500 mm²) | 925 | +800 °C / +300 °C (+1,100 °C peak) | 135 × 40 | Type A or C (Ø14) | Open flame & metal splash | 5 pcs | Request this size |
| TF-ACHC-FP-600 (600 mm²) | 1,050 | +800 °C / +300 °C (+1,100 °C peak) | 135 × 55 | Type A or C (Ø14) | Open flame & metal splash | 5 pcs | Request this size |
| TF-ACHC-FP-750 (750 mm²) | 1,225 | +800 °C / +300 °C (+1,100 °C peak) | 135 × 55 | Type A or C (Ø14) | Open flame & metal splash | 5 pcs | Request this size |
Back-to-back parallel mounting: lug-offset contact palms allow two TF-ACHC connectors to bolt onto opposite faces of a single copper busbar, doubling circuit ampacity up to 3,600 A (uninsulated) or 2,450 A (fire-protected). Final hole spacing and overall length follow the approved quotation drawing.
ASCII part references for BOM and ERP entry: TF-ACHC-120, TF-ACHC-240, TF-ACHC-300, TF-ACHC-500, TF-ACHC-750, TF-ACHC-1000, TF-ACHC-FP-150, TF-ACHC-FP-300, TF-ACHC-FP-500, TF-ACHC-FP-750.
TF-ACHC Reference Standards (DIN EN 13602 & DIN 43671)
| Standard or specification | Application |
|---|---|
| DIN EN 13602 & DIN EN 13600 Seamless Copper Tube Terminals | Soft-annealed Cu-ETP1 Ø 0.10 mm fine wire drawing and high-conductivity seamless E-copper pressed contact sleeves. |
| DIN 43671 Busbar Ampacity & SAE AS1072 Fire-Sleeve Principles | +35 °C / +70 °C busbar thermal rise convention and molten-splash silicone-over-mineral-yarn thermal protection. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and solderless press-crimp resistance verification
ASTM B187 — High-conductivity copper busbar and terminal material specification
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-SHUNT Press-Welded Laminated Copper Shunts & Heavy Flat Braided Busbar Expansion Connectors (100–4,500 mm²)
A related cable option for a different application or duty profile.
View productTF-ACC Air-Cooled Resistance Welding Jumper Cable — 150–850 mm² (ACC Series) & 400–2,000 MCM Secondary Leads
A related cable option for a different application or duty profile.
View productTF-IFL & TF-WCHC Induction Melting & Vacuum Furnace Water-Cooled Power Lead Cable (70–2,500 MCM / 35–2,000 mm²)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.