INDUSTRIAL CABLES TEBAOFLEX

TF-ACHC Air-Cooled High-Current Flexible Stranded Copper Connector Cable (70–1,000 mm², Bare, Insulated & +800 °C Pyrojacketed)

TF-ACHC (TF-ACHC-CONN) is a solderless-pressed air-cooled high-current flexible round-stranded copper connector assembly spanning 70 mm² to 1,000 mm² (300 A to 1,800 A continuous). Manufactured from ultra-fine Ø 0.10 mm soft-annealed Cu-ETP1 wires with seamless E-copper contact palms in bare, PVC/silicone-insulated, or +800 °C calcium-silicate + +300 °C silicone fire-protected furnace builds.

Product information
SKU
TF-ACHC-CONN
Brand
TEBAOFLEX
Product overview

TF-ACHC air-cooled high-current flexible copper connector cables decouple mechanical vibration, structural settling and thermal busbar expansion across 70 mm² to 1,000 mm² (300 A to 1,800 A per lead; up to 3,600 A in back-to-back busbar pairs) in industrial furnaces, rectifiers, switchgear, wind-turbine nacelles and electrolysis cell rooms.

Standard IEC Class 5 power cables (Ø 0.40–0.50 mm strands) are too stiff for short 200–1,500 mm busbar transitions and transmit destructive bending moments onto transformer studs and load cells, while flat foil shunts cannot twist out of plane. TF-ACHC ropes ultra-fine Ø 0.10 mm DIN EN 13602 ETP1 copper filaments (Ø 0.30 mm optional for heavy outdoor stiffness) and cold-presses seamless E-copper tubes into precision flat contact palms without solder.

Specify uninsulated TF-ACHC-U for maximum convective ampacity inside ventilated busbar ducts; specify PVC- or silicone-insulated TF-ACHC-I for touch/phase clearance (apply a 15–20 % enclosure thermal derating); specify fire-protected TF-ACHC-FP (inner +800 °C / +1,100 °C peak calcium-silicate yarn hose + outer +300 °C / +500 °C peak silicone cover) beside melting furnaces and ladle cars; above 2,000 A in compact furnace delta closures, switch to TF-WCHC water-cooled cables. MOQ 5 pcs per specification, 7 to 45 working days.

Explore the heavy-duty industrial cable range for related configurations.

Construction

TF-ACHC Ø 0.10 mm Stranded Copper & Fire-Hose Design

Manufactured from DIN EN 13602 soft-annealed ETP1 round-stranded copper ropes and seamless cold-pressed E-copper tubular contact palms.

Clean 2D concentric circular engineering cross-section of TF-ACHC-FP fire-protected copper connector showing red silicone outer cover, thick white calcium-silicate thermal sleeve and multi-rope Ø 0.10 mm bright copper core
Dual-wall thermal protection cross-section isolating ultra-fine Ø 0.10 mm copper strands from open flame and molten metal splash.
TF-ACHC Air-Cooled High-Current Flexible Stranded Copper Connector Cable (70–1,000 mm², Bare, Insulated & +800 °C Pyrojacketed) construction
ComponentMaterial and construction
1. Ultra-Flexible Round-Stranded Cu-ETP1 Conductor (Ø 0.10 mm)Uncoated or tinned Ø 0.10 mm soft-annealed electrolytic copper wires (optional Ø 0.30 mm wire build) delivering multi-directional vibration isolation.
2. Solderless Cold-Pressed Seamless E-Copper Contact PalmsUncoated, tin-plated, silver-plated or nickel-plated rectangular contact areas (with standard neck bend-relief) in Type A (2-hole / 4-hole) or Type C (1-hole lug) profiles.
3. Bare, PVC (+70 °C), Silicone (+180 °C) or Polyolefin InsulationOptional flexible insulating sleeve over the mid-span rope for phase-to-phase and earth clearance inside compact LV/MV cabinets.
4. Optional +800 °C Calcium-Silicate / +300 °C Silicone Fire Hose (-FP)Non-flammable inner calcium-silicate yarn tube (+800 °C continuous, +1,100 °C short-term) jacketed in self-extinguishing silicone (+300 °C continuous, +500 °C splash).

TF-ACHC Uninsulated, Insulated & -FP Code Breakdown

  • TF-ACHC-<mm²>: Air-cooled high-current flexible round-stranded copper connector (70 mm² through 1,000 mm², Ø 0.10 mm wire)
  • -U / -PVC / -SI: Uninsulated bare copper (-U), flexible PVC hose (-PVC, +70 °C) or extruded silicone sleeve (-SI, +180 °C)
  • -FP (Fire-Protected): +800 °C inner calcium-silicate yarn hose + +300 °C (+500 °C splash) outer silicone fire-protection sleeve
  • Type A vs Type C: Extended 2/4-hole rectangular contact palm with bend-relief (Type A) vs compact 1-hole lug palm (Type C)
  • -SN / -AG / -NI: Tin-plated (-SN), silver-plated (-AG) or nickel-plated (-NI) seamless pressed E-copper contact palms
Applications

TF-ACHC Furnace Busbars, Rectifiers, Electrolyzers & BESS

Engineered for high-current flexible electrical connections in furnaces, transformers, rectifiers, switchgear, rail traction and renewable energy.

Air-cooled flexible round-stranded TF-ACHC copper connector cables in red fire-sleeve and bare builds with solderless-pressed rectangular copper lugs bolted across industrial rectifier and furnace busbars
High-current rectifier and furnace secondary busbars interconnected via vibration-isolating TF-ACHC pressed-palm copper jumpers.
  • Electric melting, holding, heat-treatment and glass-furnace dry secondary busbar and heating-electrode flexible jumpers (TF-ACHC-FP).
  • Chlor-alkali, copper/zinc electrowinning, aluminum and green-hydrogen electrolyzer rectifier-to-busbar expansion connectors.
  • Low- and medium-voltage transformer bushings, generator circuit breakers, busduct seismic joints and load-cell weighed hopper/furnace leads.
  • Wind-turbine converter cabinets, grid battery-storage (BESS) DC bus links and high-current test-bench interconnects.

TF-ACHC Round Rope vs Laminated Shunt vs Water-Cooled

TF-ACHC (Round-Stranded Ø 0.10 mm) vs TF-SHUNT (Laminated / Flat Braid) vs TF-ACC (Welding Jumper) vs TF-WCHC (Water-Cooled)
High-Current ConnectorGeometry & FilamentFlex Freedom & Thermal LimitPrimary Application
TF-ACHC / TF-ACHC-FP (this page)Round rope; Ø 0.10 mm Cu-ETP1360° 3D flex + optional +800/+300 °C fire hoseFurnace electrodes, weighed hoppers, switchgear & rectifiers
TF-SHUNT Laminated / BraidFlat stack (0.1 mm foil) or flat braidMinimal height between parallel rigid busbarsTransformer LV riser expansion joints & electrolysis cells
TF-ACC Welding JumperRound rope; Ø 0.15–0.20 mm + PWIS hoseHigh-cycle torsional flex for spot-welding gunsAutomotive BIW servo spot-welding gun secondary shunts
TF-WCHC Water-Cooled CableHollow/annular rope + 6 bar waterUp to 20,000 A in 1/4 the copper cross-sectionInduction, vacuum & reduction furnaces above 1,800–3,000 A

Connecting onto precision load-cell weighed furnaces or hoppers? Specify Ø 0.10 mm uninsulated or thin-silicone TF-ACHC so cable spring stiffness does not distort weighing accuracy.

TF-ACHC High-Current Copper Connector RFQ Checklist

  • Cross-section (70 mm² to 1,000 mm²) and continuous / peak current load (A).
  • Mid-span covering: uninsulated (-U), PVC (-PVC), extruded silicone (-SI), or +800/+300 °C calcium-silicate fire sleeve (-FP).
  • Overall center-to-center or end-to-end length (mm) and palm drilling (2-hole / 4-hole Type A, 1-hole Type C, or custom drawing).
  • Contact palm surface finish: uncoated bright copper, tin-plated, silver-plated or nickel-plated (+250 °C+ furnace studs).
  • Order quantity per configuration (MOQ 5 pcs per specification, 7 to 45 working days).

Related selection resources

TF-ACHC Air-Cooled High-Current Copper Connector FAQ

Why does TF-ACHC use Ø 0.10 mm copper wires instead of standard IEC Class 5 (Ø 0.40–0.50 mm) stranding?

0.10 mm filaments have 16× to 25× lower individual bending stiffness than 0.40–0.50 mm wires, allowing short 200–800 mm high-current jumpers to flex effortlessly in all three axes without transferring vibration or thermal-expansion forces onto fragile ceramic bushings.

How much current derating applies when adding PVC, silicone or a +800 °C fire sleeve to TF-ACHC?

15 % to 20 % current reduction applies compared with bare uninsulated copper in +35 °C free air (for example TF-ACHC-500 drops from 1,100 A bare to 925 A fire-protected) because the thermal sleeve slows convective heat dissipation.

What temperatures can the TF-ACHC-FP fire-protection hose withstand near melting furnaces?

+300 °C continuous (+500 °C short-term molten splash) on the outer self-extinguishing silicone skin, backed by a non-flammable inner calcium-silicate yarn sleeve rated up to +800 °C continuous and +1,100 °C brief flame exposure.

Should I order tin-, silver- or nickel-plated contact palms on TF-ACHC connectors?

Choose tin plating for humid/chemical switchgear and aluminum-to-copper busbar joints; choose silver plating for lowest contact resistance above 1,000 A; and choose nickel plating whenever furnace busbar stud temperatures exceed +180 to +200 °C.

What is the minimum order quantity and lead time for custom TF-ACHC copper connectors?

5 pcs per specification (cross-section, length, sleeve type and palm drilling), cold-pressed and delivered in 7 to 45 working days.

Specifications

TF-ACHC (70–1,000 mm²) & TF-ACHC-FP (+800 °C) Schedule

TF-ACHC Current, Thermal Sleeve, Palm & 5-Pc MOQ Summary

  • Ultra-fine Ø 0.10 mm Cu-ETP1 wire: Thousands of Ø 0.10 mm soft-annealed copper filaments absorb transformer hum, breaker shock and multi-axis thermal expansion without transmitting force to porcelain bushings
  • Bare, insulated or +800 °C fire hose: Supplied uninsulated for maximum air convection, PVC/silicone-sleeved for switchgear, or dual-wall +800 °C calcium-silicate / +300 °C silicone pyrojacketed (-FP)
  • Solderless pressed E-copper palms: Seamless Cu-ETP tubular contact ends cold-forged without solder in rectangular busbar palms (Type A) or opposing-mount lug palms (Type C)
  • 300 A to 1,800 A per single lead: Verified single-lead free-air current ratings (and parallel pair mounting on one busbar) across 70 mm² through 1,000 mm² cross-sections
  • 5 pcs per specification MOQ: Custom-fabricated to exact customer length, bolt drilling and tin/silver/nickel contact plating from 5 pcs MOQ in 7 to 45 working days
TF-ACHC Air-Cooled High-Current Flexible Stranded Copper Connector Cable (70–1,000 mm², Bare, Insulated & +800 °C Pyrojacketed) technical data
ParameterValue
Rated voltageUp to 1000 V AC / 1500 V DC on PVC or silicone insulated builds (uninsulated builds follow busbar clearance)
Cross-section and current span70, 95, 120, 150, 185, 240, 300, 400, 500, 600, 700, 750, 850 and 1000 mm2; 300 A to 1800 A single free-air rating
Insulation and thermal tiersUninsulated bare copper, PVC (+70 C), extruded silicone (+180 C), or Fire-Protection hose (+800 C inner calcium-silicate / +300 C outer silicone)
Contact palm and platingSolderless pressed E-copper palms (Type A rectangular or Type C lug-shaped for dual-side bar mounting); bare, tin-, silver- or nickel-plated
Minimum order and lead time5 pcs per specification (cross-section, hole-to-hole length, insulation and palm drilling), delivered in 7 to 45 working days
Reference thermal basisSingle free-air laying at +35 C ambient and +70 C conductor temperature (apply 15% to 20% reduction on PVC/silicone/fire-hose insulated builds)
Single-wire filament gauge0.10 mm ultra-flexible standard (0.07 mm instrument or 0.30 mm heavy-duty filament diameter available to order)

TF-ACHC (70–1,000 mm²) Bare & Insulated Copper Connector Schedule

TF-ACHC Uninsulated & PVC/Silicone-Insulated High-Current Flexible Copper Connectors (70–1,000 mm²) — Type A & Type C Schedule
Model & Cross-SectionUninsulated Current +35/+70 °C (A)Insulated Ref. Current (A)Type A Palm Length A × Width B (mm)Bolt Hole ØD (mm)Rope Nom. Ø (mm)Assembly MOQNext step
TF-ACHC-70 (70 mm²)30025030 × 157.0 (M6)12.55 pcsRequest this size
TF-ACHC-95 (95 mm²)36030040 × 209.0 (M8)14.55 pcsRequest this size
TF-ACHC-120 (120 mm²)42035040 × 209.0 (M8)16.55 pcsRequest this size
TF-ACHC-150 (150 mm²)48040050 × 2511.0 (M10)18.55 pcsRequest this size
TF-ACHC-185 (185 mm²)57047550 × 2511.0 (M10)20.55 pcsRequest this size
TF-ACHC-240 (240 mm²)67057060 × 3211.0 (M10)23.55 pcsRequest this size
TF-ACHC-300 (300 mm²)78065080 × 4014.0 (M12)26.55 pcsRequest this size
TF-ACHC-400 (400 mm²)95080080 × 4014.0 (M12)30.55 pcsRequest this size
TF-ACHC-500 (500 mm²)1,10092580 × 4014.0 (M12)34.55 pcsRequest this size
TF-ACHC-600 (600 mm²)1,2501,05080 × 5514.0 (M12)38.55 pcsRequest this size
TF-ACHC-750 (750 mm²)1,4501,22580 × 5514.0 (M12)43.05 pcsRequest this size
TF-ACHC-850 (850 mm²)1,5501,31080 × 5514.0 (M12)46.05 pcsRequest this size
TF-ACHC-1000 (1,000 mm²)1,8001,52080 × 55–6014.0 (M12/M16)50.05 pcsRequest this size

TF-ACHC-FP (+800 °C / +300 °C) Fire-Protected Furnace Schedule

TF-ACHC-FP Furnace Fire-Protected High-Current Copper Connectors (70–750 mm² — +800 °C Calcium-Silicate / +300 °C Silicone Hose)
Model & Cross-SectionFire-Sleeve Current Load (A)Inner / Outer Thermal LimitLug-Shaped Palm A1 × B (mm)Standard DrillingSplash & Flame DutyAssembly MOQNext step
TF-ACHC-FP-70 (70 mm²)250+800 °C / +300 °C (+1,100 °C peak)50 × 15Type A or C (Ø7)Open flame & metal splash5 pcsRequest this size
TF-ACHC-FP-95 (95 mm²)300+800 °C / +300 °C (+1,100 °C peak)70 × 20Type A or C (Ø9)Open flame & metal splash5 pcsRequest this size
TF-ACHC-FP-120 (120 mm²)350+800 °C / +300 °C (+1,100 °C peak)70 × 20Type A or C (Ø9)Open flame & metal splash5 pcsRequest this size
TF-ACHC-FP-150 (150 mm²)400+800 °C / +300 °C (+1,100 °C peak)80 × 25Type A or C (Ø11)Open flame & metal splash5 pcsRequest this size
TF-ACHC-FP-185 (185 mm²)475+800 °C / +300 °C (+1,100 °C peak)80 × 25Type A or C (Ø11)Open flame & metal splash5 pcsRequest this size
TF-ACHC-FP-240 (240 mm²)570+800 °C / +300 °C (+1,100 °C peak)90 × 32Type A or C (Ø11)Open flame & metal splash5 pcsRequest this size
TF-ACHC-FP-300 (300 mm²)650+800 °C / +300 °C (+1,100 °C peak)135 × 40Type A or C (Ø14)Open flame & metal splash5 pcsRequest this size
TF-ACHC-FP-400 (400 mm²)800+800 °C / +300 °C (+1,100 °C peak)135 × 40Type A or C (Ø14)Open flame & metal splash5 pcsRequest this size
TF-ACHC-FP-500 (500 mm²)925+800 °C / +300 °C (+1,100 °C peak)135 × 40Type A or C (Ø14)Open flame & metal splash5 pcsRequest this size
TF-ACHC-FP-600 (600 mm²)1,050+800 °C / +300 °C (+1,100 °C peak)135 × 55Type A or C (Ø14)Open flame & metal splash5 pcsRequest this size
TF-ACHC-FP-750 (750 mm²)1,225+800 °C / +300 °C (+1,100 °C peak)135 × 55Type A or C (Ø14)Open flame & metal splash5 pcsRequest this size

Back-to-back parallel mounting: lug-offset contact palms allow two TF-ACHC connectors to bolt onto opposite faces of a single copper busbar, doubling circuit ampacity up to 3,600 A (uninsulated) or 2,450 A (fire-protected). Final hole spacing and overall length follow the approved quotation drawing.

ASCII part references for BOM and ERP entry: TF-ACHC-120, TF-ACHC-240, TF-ACHC-300, TF-ACHC-500, TF-ACHC-750, TF-ACHC-1000, TF-ACHC-FP-150, TF-ACHC-FP-300, TF-ACHC-FP-500, TF-ACHC-FP-750.

Standards

TF-ACHC Reference Standards (DIN EN 13602 & DIN 43671)

TF-ACHC Air-Cooled High-Current Flexible Stranded Copper Connector Cable (70–1,000 mm², Bare, Insulated & +800 °C Pyrojacketed) standards and test references
Standard or specificationApplication
DIN EN 13602 & DIN EN 13600 Seamless Copper Tube TerminalsSoft-annealed Cu-ETP1 Ø 0.10 mm fine wire drawing and high-conductivity seamless E-copper pressed contact sleeves.
DIN 43671 Busbar Ampacity & SAE AS1072 Fire-Sleeve Principles+35 °C / +70 °C busbar thermal rise convention and molten-splash silicone-over-mineral-yarn thermal protection.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and solderless press-crimp resistance verification

ASTM B187 — High-conductivity copper busbar and terminal material specification

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.