Welding Cables TEBAOFLEX

TF-ACC Air-Cooled Resistance Welding Jumper Cable — 150–850 mm² (ACC Series) & 400–2,000 MCM Secondary Leads

TF-ACC (TF-ACC-JUMPER) is a custom-length air-cooled secondary resistance-welding jumper cable spanning European metric 150 mm² to 850 mm² (ACC 150 to ACC 850) and North American 400 MCM to 2,000 MCM. Built with Ø 0.15–0.25 mm Cu-ETP rope-lay copper, high-tonnage cold-swaged silver- or tin-plated copper palms and PWIS-free solid, perforated or individually wrapped sleeves.

Product information
SKU
TF-ACC-JUMPER
Brand
TEBAOFLEX
Product overview

TF-ACC air-cooled resistance-welding jumper cables form the ultra-flexible dry secondary current bridge between integrated MFDC weld-gun transformers and moving C-gun or X-gun electrode arms, multi-spot welding fixtures and electrolytic busbars across 150–850 mm² (520–1,614 A continuous; up to 30 kA pulsed) and 400–2,000 MCM.

In modern automotive body-in-white (BIW) plants, weld-gun designers frequently eliminate secondary water-cooled jumpers over the workpiece so a ruptured hose can never spray cooling water onto hot galvanneal sheet or servo-gun electronics. Because ambient air removes far less heat than water, dry jumpers suffer rapid internal wire-on-wire fretting and collar breakage unless rope pitch, ventilation and swaging are engineered together: TF-ACC offers relaxed-pitch extra-flexible stranding, breathable perforated neoprene/EPDM covers (-P) that boost convective cooling by 15–20 %, and individually polymer-wrapped internal ropes (-IW) that eliminate inter-rope friction.

Specify metric TF-ACC 300 / 315 / 400 / 500 / 630 / 800 mm² (straight D or 90° bent C palms, Ø 13 mm bolt hole) for European robotic servo guns; specify TF-ACC 600 / 750 / 1,000 / 1,200 / 1,500 MCM (17/32" or 21/32" holes, silver-plated palms) for North American weld tooling; where weld duty cycle overheats dry jumpers, upgrade to TF-WCRW unipolar water-cooled cable. MOQ 5 pcs per specification, 7 to 45 working days.

Explore the welding cable range for related configurations.

Construction

TF-ACC Air-Cooled Resistance Welding Jumper Construction

Constructed with DIN EN 13602 soft-annealed Cu-ETP fine ropes, solderless cold-swaged copper palms and silicone-free abrasion-resistant elastomer sleeves.

Clean 2D circular engineering cross-section of TF-ACC air-cooled jumper cable showing outer black perforated rubber sleeve ring, convective air-cooling gap and 19-rope (1+6+12) bare multi-strand bright copper bundle
Perforated air-cooled cross-section: radial ventilation openings around a 1+6+12 (19-rope) bare copper bundle for dry secondary spot-welding duty.
TF-ACC Air-Cooled Resistance Welding Jumper Cable — 150–850 mm² (ACC Series) & 400–2,000 MCM Secondary Leads construction
ComponentMaterial and construction
1. Extra-Flexible Rope-Lay Cu-ETP Copper (Ø 0.15–0.25 mm / 30 AWG)99.9 %+ pure electrolytic copper ropes laid with torsional relaxation spacing for multi-axis robotic curling and bending without birdcaging.
2. Optional Individual Rope Polymer Wrapping (-IW Isolated Build)High-lubricity carbon-polymer coating around each internal copper sub-rope stops strand-to-strand galling and rear-of-terminal fatigue.
3. Cold-Swaged Silver- or Tin-Plated Seamless Copper TerminalsHigh-tonnage die-swaged Cu-HCP palms (straight F/D, 45°, 90° bent C/FR90, or offset VO/LO) with optional extended stabilizer collars (-E) to relieve neck stress.
4. PWIS-Free Solid or Perforated Neoprene / EPDM Protective SleeveLoose-fitting flame-retardant polychloroprene or textile-reinforced EPDM cover (solid for spatter exclusion, or perforated -P for convective air cooling).

TF-ACC Metric, MCM & Sleeve Code Breakdown

  • TF-ACC <mm²>: European metric air-cooled copper jumper cable (150 mm² through 850 mm², straight D or 90° bent C palms)
  • TF-ACC <MCM>: North American circular-mil air-cooled jumper cable (400 MCM through 2,000 MCM, 17/32" or 21/32" bolt holes)
  • -P (Perforated): Breathable perforated neoprene/EPDM protective cover boosting convective air cooling on robotic weld guns
  • -IW (Isolated Rope): Each internal copper sub-rope individually coated in high-carbon polymer to eliminate strand-on-strand wear
  • -S / -E Suffix: Silver-plated swaged copper contact palms (-S) and extended terminal neck stabilizer collar (-E)
Applications

TF-ACC Robotic Servo Guns, Multi-Spot Presses & Fixtures

Engineered for dry secondary current transfer on robotic trans-gun spot welders, multi-spot fixture presses, nut welders and busbar links.

Short heavy black TF-ACC air-cooled secondary jumper cable with cold-swaged silver-plated flat copper contact palms bolted between an integrated robotic weld-gun transformer and moving C-gun electrode arm
Automotive robotic trans-gun servo spot welder equipped with dry TF-ACC swaged silver-plated copper jumper leads.
  • 6-axis automotive BIW servo C-guns and X-guns (short dry secondary jumper from 1,000 Hz MFDC gun transformer to moving electrode arm).
  • Multi-spot resistance projection welding presses, cross-wire mesh welders, appliance cabinet fixtures and fastener/nut welding machines.
  • Dry ground-return jumpers, rotary welding positioner earth shunts and portable pincer gun secondary connections.
  • Flexible air-cooled busbar transitions in electroplating rectifiers, induction-heater cabinets and low-voltage high-current test benches.

TF-ACC Air-Cooled vs Water-Cooled Jumper vs Copper Shunt

TF-ACC Air-Cooled Jumper vs TF-WCRW Water-Cooled Jumper vs TF-SHUNT Laminated Shunt vs TF-ACHC Connector
Flexible Copper LinkMotion & CoolingKey Mechanical AdvantageBest Engineering Fit
TF-ACC Jumper (this page)Dynamic 3D twist/bend; dry airZero coolant water risk + perforated or IW anti-fretting ropesRobotic C-gun / X-gun moving arms & multi-spot weld fixtures
TF-WCRW Unipolar Water-CooledDynamic 3D bend; 4–6 L/min water50 % smaller copper cross-section & lighter gun weightHigh-spot-rate servo guns, projection & roller seam welders
TF-SHUNT Laminated Copper ShuntSingle-plane linear flex; dry airUltra-compact flat stack of press-welded 0.1 mm Cu foilsTight linear hinge/platen travel & furnace busbar expansion
TF-ACHC High-Current ConnectorVibration / static flex; dry airØ 0.10 mm wires + optional +800 °C fire-protection sleeveSwitchgear, rectifiers & radiant-heat furnace bus connections

Does your jumper twist as well as bend? Laminated foil shunts (TF-SHUNT) bend cleanly in one plane only—always use round rope-lay TF-ACC jumpers whenever multi-axis torsion occurs.

TF-ACC Air-Cooled Jumper Terminal & Length RFQ Checklist

  • Cross-section in mm² (150–850 mm²) or MCM (400–2,000 MCM) and hole-center to hole-center length (mm or inches).
  • End 1 and End 2 palm geometry (straight, 45°, 90° bent, or offset; rotational twist angle between palms; hole diameter & count).
  • Internal build and sleeve: standard solid rubber, breathable perforated cover (-P), or individually polymer-wrapped ropes (-IW).
  • Palm surface finish: silver-plated (lowest contact resistance), tin-plated, or bright uncoated copper.
  • Quantity per specification (MOQ 5 pcs per part configuration, 7 to 45 working days).

Related selection resources

TF-ACC Air-Cooled Resistance Welding Jumper Cable FAQ

When should I specify a perforated sleeve (-P) versus a solid sleeve on TF-ACC air-cooled jumper cables?

Specify the perforated sleeve (-P) on high-cycle robotic weld guns in clean BIW cells where air circulation through the holes lowers copper operating temperature by 10–15 °C; specify the solid non-perforated sleeve where heavy molten weld spatter or grinding dust could enter perforations.

What problem does the Individually Wrapped (-IW) isolated-conductor TF-ACC jumper solve?

100 % polymer wrapping around each internal copper rope eliminates bare copper-on-copper rubbing during millions of robotic flex cycles, stopping internal strand galling and rear-of-terminal wire breakage without needing a stiff outer rubber hose.

Why are cold-swaged silver-plated terminals preferred over soldered lugs on TF-ACC jumpers?

200-ton+ cold swaging compresses the copper palm and fine strands into a monolithic gas-tight joint with lower micro-ohm resistance than tin-lead solder, which wicks up strands, creates a brittle fracture point and can soften during heavy weld-current surges.

How do I measure the length of a TF-ACC air-cooled jumper cable with 90-degree bent or offset terminals?

Measure straight-line bolt-hole center to bolt-hole center (or state developed center-line length on a dimensioned sketch) and specify whether the two 90-degree flags face the same direction (0° twist) or opposite/perpendicular directions (90° / 180°).

What is the minimum order quantity and delivery lead time for TF-ACC air-cooled jumper cables?

5 pcs per specification (cross-section, center-to-center length and terminal geometry), custom-swaged and delivered in 7 to 45 working days.

Specifications

TF-ACC (150–850 mm² & 400–2,000 MCM) Jumper Schedule

TF-ACC Swaged Palms, PWIS-Free Sleeves & 5-Pc MOQ

  • Metric 150–850 mm² & 400–2,000 MCM: Covers both European robotic ACC 300 / 315 / 500 / 800 mm² jumpers and North American 400 / 600 / 1,000 / 1,500 / 2,000 MCM spot-welding shunts
  • Solid, perforated or IW-rope builds: Available with non-perforated rubber hose, breathable perforated extra-flex hose (-P), or individually polymer-wrapped anti-fretting copper ropes (-IW)
  • Cold-swaged silver/tin Cu palms: Seamless forged Cu-ETP/Cu-HCP terminals swaged without solder in straight (0°), 45°, 90° bent or offset geometries to minimize micro-ohm contact loss
  • 100 % PWIS-free for BIW paint lines: Silicone-free (LABS-frei / PWIS-free) neoprene/EPDM rubber and textile-reinforced sleeves eliminate automotive paint-shop crater contamination
  • 5 pcs per specification MOQ: Manufactured in exact 25 mm or 0.5-inch hole-center increments (150 mm to 5,000 mm) from 5 pcs MOQ in 7 to 45 working days
TF-ACC Air-Cooled Resistance Welding Jumper Cable — 150–850 mm² (ACC Series) & 400–2,000 MCM Secondary Leads technical data
ParameterValue
Rated voltageLow-voltage secondary resistance-welding and busbar duty (typically below 50 V AC / MFDC)
Cross-section rangeEuropean metric 150, 200, 250, 300, 315, 400, 500, 600, 630, 750, 800 and 850 mm2; North American 400, 500, 600, 750, 1000, 1200, 1500 and 2000 MCM
Conductor and sleeve variantsStandard bare Cu-ETP rope, Extra-Flexible robotic pitch (-X), Perforated cooling sleeve (-P) and Individually Wrapped isolated ropes (-IW)
Terminal palm and platingCold-swaged silver-plated or tin-plated copper palms; straight, 45 deg, 90 deg or offset; 13 mm (M12), 17/32 in (13.5 mm) or 21/32 in (16.7 mm) holes
Minimum order and lead time5 pcs per specification (cross-section, center-to-center length and palm style), delivered in 7 to 45 working days
Standard length increments150 mm to 5000 mm (6 in to 196 in) measured bolt-hole center to bolt-hole center in 25 mm or 0.5 in steps
Automotive paint-shop safety100% PWIS-free / LABS-frei (silicone-free) elastomer sleeves approved for automotive body-in-white welding cells

TF-ACC (150–850 mm²) European Metric Air-Cooled Jumper Schedule

TF-ACC European Metric Air-Cooled Resistance Welding Jumper Cable (150 mm² to 850 mm²) — Dimensional & Thermal Current Schedule
Model & Cross-SectionPalm Width W × Thickness t (mm)Standard Hole Ød (mm)Sleeve Nom. OD (mm)Continuous Current ΔT 50–60 °C (A)Terminal OptionsAssembly MOQNext step
TF-ACC 150 mm² (ACC 150)32 × 8.013 (M12)28520Straight D / 90° C5 pcsRequest this size
TF-ACC 200 mm² (ACC 200)32 × 10.513 (M12)34620Straight D / 90° C5 pcsRequest this size
TF-ACC 250 mm² (ACC 250)32 × 13.013 (M12)36700Straight D / 90° C5 pcsRequest this size
TF-ACC 300 mm² (ACC 300)32 × 14.013 (M12)38780Straight D / 90° C5 pcsRequest this size
TF-ACC 315 mm² (Robotic)32 × 15.013 (M12)39820 (1,614 at <0.5m)Straight D / 90° C5 pcsRequest this size
TF-ACC 400 mm² (ACC 400)32 × 18.013 (M12)40920 (1,804 at <0.5m)Straight D / 90° C5 pcsRequest this size
TF-ACC 500 mm² (ACC 500)32 × 22.013 (M12)431,060 (2,034 at <0.5m)Straight D / 90° C5 pcsRequest this size
TF-ACC 600 mm² (ACC 600)32–40 × 25.013 (M12)471,200Straight D / 90° C5 pcsRequest this size
TF-ACC 630 mm² (Robotic)38 × 24.013 / 17491,260 (2,302 at <0.5m)Straight D / 90° C5 pcsRequest this size
TF-ACC 750 mm² (ACC 750)40 × 25.013 / 17541,390Straight D / 90° C5 pcsRequest this size
TF-ACC 800 mm² (ACC 800)38–40 × 29.013 / 17571,470 (2,609 at <0.5m)Straight D / 90° C5 pcsRequest this size
TF-ACC 850 mm² (ACC 850)40 × 27.017 (M16)621,540Straight D / 90° C5 pcsRequest this size

TF-ACC (400–2,000 MCM) North American Air-Cooled Jumper Schedule

TF-ACC North American MCM Air-Cooled Jumper Cable (400 MCM to 2,000 MCM) — Swaged Silver-Plated Terminal Schedule
Model & MCM SizeMetric Equiv. (mm²)Sleeve OD (in / mm)Palm Width B × Thickness C (in)Standard Bolt HolesCover / Rope BuildAssembly MOQNext step
TF-ACC 400 MCM203 mm²1.38" / 35.01.25" or 1.38" × 0.38"17/32" (13.5 mm)Solid / Perforated / IW5 pcsRequest this size
TF-ACC 500 MCM253 mm²1.50" / 38.11.25" or 1.38" × 0.44"17/32" (13.5 mm)Solid / Perforated / IW5 pcsRequest this size
TF-ACC 600 MCM304 mm²1.63" / 41.31.38" × 0.50"17/32" or 21/32"Solid / Perforated / IW5 pcsRequest this size
TF-ACC 750 MCM380 mm²1.75" / 44.51.38" × 0.60"17/32" or 21/32"Solid / Perforated / IW5 pcsRequest this size
TF-ACC 1000 MCM507 mm²2.00" / 50.81.50" × 0.70"17/32" or 21/32"Solid / Perforated / IW5 pcsRequest this size
TF-ACC 1200 MCM608 mm²2.12" / 54.01.50" × 0.82"17/32" or 21/32"Solid / Perforated / IW5 pcsRequest this size
TF-ACC 1500 MCM760 mm²2.25" / 57.21.50" × 0.99"21/32" (16.7 mm)Solid / Perforated / IW5 pcsRequest this size
TF-ACC 2000 MCM1,013 mm²2.56" / 65.01.75" × 1.15"21/32" or 2-HoleSolid / Perforated / IW5 pcsRequest this size

Note on short jumper heat conduction: on short robotic gun jumpers (< 500 mm), massive water-cooled copper gun arms and transformer pads conduct heat out through both swaged copper palms, allowing higher permanent currents (shown in parentheses for 315–800 mm²) than long free-air runs. Final palm bends and hole centers are confirmed on the quotation drawing.

ASCII part references for BOM and ERP entry: TF-ACC-300, TF-ACC-315, TF-ACC-400, TF-ACC-500, TF-ACC-630, TF-ACC-800, TF-ACC-600MCM, TF-ACC-750MCM, TF-ACC-1000MCM, TF-ACC-1200MCM, TF-ACC-1500MCM, TF-ACC-2000MCM.

Standards

TF-ACC Reference Standards (DIN EN 13602 & ASTM B172)

TF-ACC Air-Cooled Resistance Welding Jumper Cable — 150–850 mm² (ACC Series) & 400–2,000 MCM Secondary Leads standards and test references
Standard or specificationApplication
DIN EN 13602 / ASTM B172 Rope-Lay Electrolytic Copper100 % IACS soft-annealed Cu-ETP fine wire stranding (Ø 0.15–0.25 mm / 30 AWG) and solderless swaged Cu-HCP terminals.
IEC 61439 / IEC 439 Thermal Rise & Automotive BIW PWIS-FreeΔT 50–60 K busbar/jumper thermal rating basis and 100 % silicone-free (LABS-frei) protective elastomer sleeves.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and micro-ohm terminal crimp verification

ASTM B172 — Standard Specification for Rope-Lay-Stranded Copper Conductors

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.