Port & Festoon Cables TEBAOFLEX

PROFIBUS L2 150Ω High-Flex Crane Festoon & Torsion Bus Cable (1×2×0.65 / 1×2×0.80 mm)

PROFIBUS L2 (PROFIBUS-L2-FESTOON 1x2x0.65 mm and PROFIBUS-L2-TORSION 1x2x0.80 mm) is a 150 Ω ± 10% high-flex crane fieldbus cable pair engineered to DIN 19245 T3 and EN 50170 with 19-wire stranded bare copper conductors (AWG 23/19 or AWG 22/19), red and green Cell-PE or Foam-Skin-PE core insulation, polyester separator foil, 100% aluminium foil plus tinned copper braided double shielding, and an 8.0 mm Petrol RAL 5018 PVC or Violet RAL 4001 PUR outer sheath.

Product information
SKU
CR-PROFIBUS-L2-FLEX
Brand
TEBAOFLEX
Product overview

Solid-conductor (1x2x0.64 mm) standard PROFIBUS DP installation cables work well in fixed control cabinets but suffer rapid conductor work-hardening and breakage when routed through overhead crane festoon loops, high-acceleration energy chains or twisting robot and spreader axes. At the same time, crane VFD drives require full 360-degree double shielding and exact 150 Ω ± 10% impedance to prevent RS-485 telegram reflections up to 12 Mbit/s.

This product page covers the two specialized 19-wire stranded PROFIBUS L2 crane and automation constructions compliant with DIN 19245 Part 3 and EN 50170: PROFIBUS-L2-FESTOON (1x2x0.65 mm, AWG 23/19 bare copper, Cell-PE red/green cores stranded with two fillers, 70 mm repeated bending radius, -40 °C to +60 °C, Petrol RAL 5018 PVC jacket) and PROFIBUS-L2-TORSION (1x2x0.80 mm, AWG 22/19 bare copper, Foam-Skin-PE red/green cores stranded with filler, 120 mm repeated bending radius, -30 °C to +70 °C, Violet RAL 4001 PUR jacket). Both maintain an 8.0 mm nominal outer diameter (±0.3 mm or ±0.4 mm) for direct compatibility with industrial PROFIBUS Sub-D and M12 connectors.

Choose PROFIBUS-L2-FESTOON (133 Ω/km max. loop resistance, 64 kg/km) for linear crane festoon loops and gantry drag chains, or PROFIBUS-L2-TORSION (115.2 Ω/km max. loop resistance, 66 kg/km, oil/abrasion-resistant PUR) where multi-axis torsional twist and lower loop resistance are required.

Explore the port and festoon cable range for related configurations.

Construction

PROFIBUS L2 150Ω Crane Festoon & Torsion Bus Cable Construction

The representative horizontal sample illustrates PROFIBUS-L2-TORSION (1x2x0.80 mm, Violet RAL 4001 PUR, 8.0 mm O.D.): red and green Foam-Skin-PE insulated 19-wire bare copper conductors (AWG 22/19) stranded with round fillers, polyester separator foil, 100% aluminium foil shield, tinned copper braided shield and a violet polyurethane outer sheath.

Flat 2D cross-section diagram of PROFIBUS L2 150 Ohm high-flex crane festoon and torsion bus cable showing 19-wire stranded bare copper conductors, red and green Foam-Skin-PE insulation, bedding fillers, polyester separator tape, aluminium foil shield, tinned copper braided shield and violet PUR outer sheath
PROFIBUS L2 cross-section: 19-wire copper pair, Foam-Skin-PE insulation, fillers, Al foil, tinned Cu braid and PUR outer sheath.
PROFIBUS L2 150Ω High-Flex Crane Festoon & Torsion Bus Cable (1×2×0.65 / 1×2×0.80 mm) construction
ComponentMaterial and construction
19-Wire Stranded Bare Copper ConductorsFestoon: 1x2x0.65 mm (AWG 23/19) bare copper (23.0 kg/km Cu weight). Torsion: 1x2x0.80 mm (AWG 22/19) bare copper (32.0 kg/km Cu weight).
Cellular / Foam-Skin PE Core InsulationRed (Line B) and Green (Line A) low-permittivity Cell-PE (Festoon, 81% velocity of propagation) or Foam-Skin-PE (Torsion) dielectric maintaining 150 Ω ± 10% impedance.
Symmetrical Stranding with Fillers & TapeTwo bus cores stranded with precision bedding fillers and wrapped in a non-hygroscopic polyester separator foil to preserve pair symmetry under bending and torsion.
Dual Al-Foil + Tinned Copper Braid Shield100% coverage aluminium foil inner shield (Shielding 1) under a high-coverage tinned copper braided overall shield for broadband VFD EMC immunity.
Petrol PVC or Violet PUR Outer Sheath8.0 mm nominal O.D. outer jacket: Petrol (similar to RAL 5018) PVC on Festoon (-40 °C to +60 °C, 1.09 MJ/m) or Violet (similar to RAL 4001) PUR on Torsion (-30 °C to +70 °C, 0.89 MJ/m).

PROFIBUS L2 1x2x0.65 and 1x2x0.80 Designation Breakdown

  • PROFIBUS L2: process fieldbus L2 / FIP 150 Ohm RS-485 differential shielded twisted-pair bus cable
  • 1x2x0.65 / 1x2x0.80: single twisted pair (Red + Green) with 0.65 mm (festoon/chain) or 0.80 mm (torsion) core conductor
  • Foam-Skin PE: low-capacitance (approx. 30 nF/km) cellular polyethylene insulation for 12 Mbit/s transmission
  • Al-Foil + Cu Braid + PUR/PVC: dual 100% foil and tinned copper braid shield under violet PVC or halogen-free PUR jacket
Applications

PROFIBUS L2 Crane Festoon, Drag Chain & Torsion Applications

Deploy PROFIBUS L2 150 Ω high-flex bus cables on automated cranes, stacker-reclaimers, AS/RS storage cranes and robotic handling cells.

Violet PROFIBUS L2 high-flex fieldbus cables routed through an automated crane trolley energy chain into a stainless-steel PLC control cabinet
PROFIBUS L2 150 Ω high-flex fieldbus cables operating in an automated crane energy chain and PLC cabinet.
  • Overhead bridge crane, RMG/RTG yard crane and stacker-reclaimer C-track festoon loops and linear energy chains (PROFIBUS-L2-FESTOON 1x2x0.65 mm).
  • Multi-axis torsional cable loops on crane spreaders, slewing rings, robotic palletizers and automated guided vehicles (PROFIBUS-L2-TORSION 1x2x0.80 mm).
  • 150 Ω RS-485 PROFIBUS DP and PROFIBUS FMS fieldbus links from 9.6 kbit/s up to 12 Mbit/s between crane PLCs, remote I/O drops, absolute encoders and VFD inverters.
  • Direct 8.0 mm O.D. replacement for DIN 19245 T3 / EN 50170 trailing and torsion bus cables in ports, steelworks, automotive plants and automated warehouses.

PROFIBUS L2 vs PROFINET Type C and Hybrid Reeling Selection Boundary

PROFIBUS L2 Festoon & Torsion Bus Cable compared with related industrial and mining data cables
ModelPair layout & impedanceConductor & outer jacketBest fit
PROFIBUS-L2-FESTOON (this page)1x2x0.65 mm, 150 Ω ± 10%AWG 23/19 bare Cu + Cell-PE + Al/Cu shield + Petrol PVCCrane C-track festoon loops & linear drag chains (70 mm bend, -40 to +60 °C)
PROFIBUS-L2-TORSION (this page)1x2x0.80 mm, 150 Ω ± 10%AWG 22/19 bare Cu + Foam-Skin-PE + Al/Cu shield + Violet PURMulti-axis torsion, crane spreaders & robotics (120 mm bend, 115.2 Ω/km loop)
MHSYV-5 Cat5 Mine Data Cable4x2x0.5 mm, 100 Ω ± 15%Solid/stranded Cu + PE + flame-retardant PVC sheathUnderground coal mine 100 Mbit/s Ethernet & RS-485 haulage trunks
Flexible Crane Fibre Optic Cable2 to 24 optical fibresTight-buffer or loose-tube + aramid + PUR/rubber jacketEMI-immune optical Ethernet & PROFIBUS OLM crane backbones

Specify PROFIBUS-L2-FESTOON (Petrol RAL 5018 PVC) for single-plane festoons and drag chains, or PROFIBUS-L2-TORSION (Violet RAL 4001 PUR) for twisting axes.

Related selection resources

PROFIBUS L2 Crane Bus Cable Frequently Asked Questions

When should engineers select PROFIBUS-L2-FESTOON (1x2x0.65 mm) versus PROFIBUS-L2-TORSION (1x2x0.80 mm)?

Select PROFIBUS-L2-FESTOON (Petrol RAL 5018 PVC, 70 mm repeated bending radius, -40 °C to +60 °C) for single-plane linear bending in crane C-track festoons and drag chains. Select PROFIBUS-L2-TORSION (Violet RAL 4001 PUR, 120 mm repeated bending radius, -30 °C to +70 °C) when the cable experiences axial torsion on crane spreaders, rotating turrets or robot arms, or when the larger 0.80 mm (AWG 22/19) conductor is needed to lower loop resistance from 133.0 Ω/km to 115.2 Ω/km.

Why do both dynamic PROFIBUS L2 variants use 19-wire stranded copper instead of solid 0.64 mm copper?

Standard fixed PROFIBUS cable uses a single solid 0.64 mm wire that fractures after a few thousand bending cycles. Replacing the solid wire with a 19-strand rope bundle (AWG 23/19 on Festoon and AWG 22/19 on Torsion) and recalibrating the Cell-PE / Foam-Skin-PE insulation diameter preserves the exact 150 Ω ± 10% impedance while achieving millions of flex or torsion cycles.

How does the double shield (Al-Foil + Tinned Copper Braid) protect 12 Mbit/s PROFIBUS telegrams on VFD cranes?

Variable-frequency hoist and trolley drives generate both low-frequency switching harmonics and high-frequency common-mode spikes. The tinned copper braid provides low transfer impedance below 1 MHz and mechanical termination strength in metallic connector glands, while the 100% coverage aluminium foil blocks high-frequency RF noise up to 16 MHz and beyond.

Are PROFIBUS-L2-FESTOON and PROFIBUS-L2-TORSION compatible with standard 8.0 mm PROFIBUS connectors?

Yes. Both variants are manufactured to an 8.0 mm nominal outer diameter (8.0 ± 0.3 mm on Festoon and 8.0 ± 0.4 mm on Torsion) with standard red (Line B) and green (Line A) core colours, fitting standard industrial PROFIBUS M12 and 9-pin Sub-D connectors.

Specifications

PROFIBUS L2 150Ω Electrical & Mechanical Schedules & Specifications

PROFIBUS L2 Key Specifications

  • Two dynamic variants: Festoon (1x2x0.65 mm, AWG 23/19, PVC) & Torsion (1x2x0.80 mm, AWG 22/19, PUR)
  • 150 Ω bus impedance: 150 Ω ± 10% characteristic impedance; 28 or 30 nF/km mutual capacitance to EN 50170
  • Loop resistance: Max. 133.0 Ω/km (1x2x0.65 mm Festoon) and 115.2 Ω/km (1x2x0.80 mm Torsion)
  • Double EMC shielding: Aluminium foil (Shield 1) + high-coverage tinned copper braid over polyester separator tape
  • Outer diameter & bend: 8.0 mm nominal O.D. (fits FastConnect M12 / Sub-D); 70 mm (Festoon) or 120 mm (Torsion) bend
PROFIBUS L2 150Ω High-Flex Crane Festoon & Torsion Bus Cable (1×2×0.65 / 1×2×0.80 mm) technical data
ParameterValue
Variants & conductor sizesFestoon: 1x2x0.65 mm (AWG 23/19); Torsion: 1x2x0.80 mm (AWG 22/19)
Impedance & capacitance150 Ω ± 10% characteristic impedance; 28 nF/km (Festoon) or 30 nF/km (Torsion) mutual capacitance
DC & loop resistance (20 °C)Festoon: 66.5 Ω/km core / 133.0 Ω/km loop; Torsion: 57.6 Ω/km core / 115.2 Ω/km loop
Attenuation (9.6 kHz to 16 MHz)9.6 kHz: up to 3.0 / 2.5 dB/km; 38.4 kHz: up to 3.0 / 4.0 dB/km; 4 MHz: up to 25.0 dB/km; 16 MHz: up to 49.0 dB/km
Diameter, bend radius & temp8.0 mm O.D. (±0.3 / ±0.4 mm); 70 mm (Festoon, -40 to +60 °C) or 120 mm (Torsion, -30 to +70 °C) repeated bend radius
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7 to 45 working days; final values confirmed on the quotation drawing
Selection boundary vs MHSYV-5 and Crane Fibre OpticChoose PROFIBUS L2 150 Ω for 1-pair RS-485 PROFIBUS DP/FMS crane festoon and torsion links; choose MHSYV-5 (4x2x0.5 mm, 100 Ω) for underground mine Cat5 Ethernet, or Flexible Crane Fibre Optic Cable for optical crane data backbones above 100 m.

PROFIBUS L2 150Ω Festoon & Torsion Bus Cable Variants

PROFIBUS L2 150 Ω High-Flex Festoon (1x2x0.65 mm) & Torsion (1x2x0.80 mm) — Construction & Mechanical Schedule
Part ReferenceDynamic Duty TypeConductor & StrandingCore Insulation & ColoursStranding & Shielding BuildOuter Sheath & ColourNominal O.D.Cable / Cu WeightRepeated Bend RadiusOperating Temp.Next step
PROFIBUS-L2-FESTOONFestoon & Drag-Chain Duty1x2x0.65 mm (AWG 23/19 bare Cu)Cell-PE (Red & Green)2 cores + 2 fillers + PES foil + Al-Foil + tinned Cu braidPetrol PVC (RAL 5018)8.0 ± 0.3 mm64 kg/km (23 kg/km Cu)70 mm repeated-40 °C to +60 °CRequest this size
PROFIBUS-L2-TORSIONTorsion & Spreader Duty1x2x0.80 mm (AWG 22/19 bare Cu)Foam-Skin-PE (Red & Green)2 cores + filler + PES foil + Al-Foil + tinned Cu braidViolet PUR (RAL 4001)8.0 ± 0.4 mm66 kg/km (32 kg/km Cu)120 mm repeated-30 °C to +70 °CRequest this size

PROFIBUS L2 150Ω Electrical & Dynamic Transmission Parameters

PROFIBUS L2 150 Ω Festoon vs Torsion — Electrical, Impedance & Attenuation Schedule (DIN 19245 T3 / EN 50170)
Electrical ParameterPROFIBUS-L2-FESTOON (1x2x0.65 mm)PROFIBUS-L2-TORSION (1x2x0.80 mm)Test / Standard Condition
Characteristic Impedance150 Ω ± 10%150 Ω ± 10%DIN 19245 T3 & EN 50170
Max. Single-Core DC Resistance66.5 Ω/km57.6 Ω/kmAt 20 °C
Max. Loop Resistance133.0 Ω/km115.2 Ω/kmAt 20 °C
Nominal Mutual Capacitance28 nF/km30 nF/kmAt 800 Hz / 1 kHz
Min. Insulation Resistance & Test Voltage1.6 GΩ·km / 2.0 kV test5.0 GΩ·km / 1.5 kV testCore-to-core & core-to-shield
Attenuation at 9.6 kHz / 38.4 kHzMax. 3.0 dB/km / 3.0 dB/kmMax. 2.5 dB/km / 4.0 dB/kmLow-baud-rate RS-485 bus
Attenuation at 4 MHz / 16 MHzMax. 25.0 dB/km / 49.0 dB/kmMax. 25.0 dB/km / 49.0 dB/kmHigh-speed 12 Mbit/s PROFIBUS DP

Both PROFIBUS-L2-FESTOON (8.0 ± 0.3 mm) and PROFIBUS-L2-TORSION (8.0 ± 0.4 mm) maintain the standard 8.0 mm PROFIBUS outer diameter so standard Sub-D and M12 fieldbus connectors clamp the outer sheath and 360-degree tinned copper braid without adapters.

UL 62, CSA C22.2 No. 49, ASTM B-3 / B-172 / B-174, NEC Table 400.5(A) and DIN 19245 T3 / EN 50170 are cited as governing design and performance references; TEBAOFLEX manufactures to the referenced construction parameters and confirms project-specific marking and test documentation on the quotation drawing.

ASCII part references for BOM and ERP entry: PROFIBUS-L2-FESTOON, PROFIBUS-L2-TORSION.

Standards

PROFIBUS L2 Standards & Test References (IEC 61158-2, UL 2570)

PROFIBUS L2 150Ω High-Flex Crane Festoon & Torsion Bus Cable (1×2×0.65 / 1×2×0.80 mm) standards and test references
Standard or specificationApplication
DIN 19245 Part 3 & EN 50170 (IEC 61158)Process Field Bus (PROFIBUS DP / FMS) physical-layer specification for 150 Ω ± 10% shielded twisted-pair data cables.
IEC 60228 / AWG 23/19 & AWG 22/1919-wire concentric stranded bare copper conductor construction for repeated flexing and torsional endurance.
EN 50288-2 / VDE 0819Multi-element metallic communication cable testing for impedance, mutual capacitance, loop resistance and attenuation up to 16 MHz.
RAL 5018 (Petrol PVC) & RAL 4001 (Violet PUR)Standard industrial sheath colour coding distinguishing PVC festoon duty from halogen-free PUR torsion duty.

Certifications and document support

TEBAOFLEX company certificates and quality system documentation

IEC Webstore — IEC 61158 / EN 50170 fieldbus and IEC 60228 conductor standards

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.