Submersible Pump Cables TEBAOFLEX

PVC Insulated PE Sheathed Drinking Water Pump Cable 0.6/1 kV

This 0.6/1 kV drinking-water pump cable combines flexible Class 5 plain copper conductors, PVC core insulation and a bright blue polyethylene outer sheath.

  • 0.6/1 kV
  • PVC core insulation and a bright blue polyethylene outer sheath
  • Class 5 plain copper conductors
  • 70 °C maximum conductor temperature
  • 3G and 4G versions in 1.5 and 2.5 mm²
Product information
Brand
TEBAOFLEX
Product overview

This 0.6/1 kV drinking-water pump cable combines flexible Class 5 plain copper conductors, PVC core insulation and a bright blue polyethylene outer sheath. The four listed configurations cover 3G and 4G constructions in 1.5 mm² and 2.5 mm² for small submersible pump connections and outdoor water-supply equipment.

Choose the conductor arrangement from the pump wiring diagram. The three-core version contains green/yellow, blue and brown cores. The four-core version contains green/yellow, brown, black and grey cores. Each configuration has its own nominal insulation diameter, finished cable diameter, mass and maximum tensile-force value in the specification table.

The PE outer sheath provides the water-facing surface, while PVC remains the electrical insulation around each conductor. This material combination has a maximum conductor temperature of 70 °C and an installation minimum of 0 °C. Coordinate handling, cable entries and support positions around those conditions when planning the route.

Use the finished nominal diameter to select the pump entry seal and allow the accessory supplier to confirm its compression range. Provide motor current, starting method, route length and the required 3G or 4G arrangement for sizing. Include the water composition and the applicable drinking-water contact requirements for the cable, joints and accessories. Water depth and water-temperature limits are confirmed for the project after enquiry. For installations requiring an EPR-insulated construction, compare the round drinking-water pump cable family in the related selection links.

Construction

Construction

Cable layers are listed from the conductor to the outer sheath.

PVC insulated PE sheathed 4G2.5 pump cable cross-section with four fine-stranded copper conductors in square packing
Representative PVC/PE 4G2.5 construction; other configurations are listed in the specification tables.
Cable layers
LayerConstruction
ConductorPlain stranded copper, Class 5.
InsulationPVC around each conductor.
Core arrangement3G or 4G round assembly with a green/yellow protective conductor.
Outer sheathBright blue PE. The PVC insulation remains part of the complete cable construction.
Applications

Applications

Use this construction for small drinking-water submersible pumps and outdoor pump connections. Match the cable to the actual equipment, route and water medium before selecting the final configuration.

Blue pump cable supported on a fixed post between a closed control cabinet and a sealed water-supply wellhead
Application illustration: supported motor-cable route between a closed control cabinet and a sealed water-supply wellhead.
  • Choose 3G or 4G from the pump wiring diagram and check the listed nominal diameter.
  • Distinguish a PE sheath from a completely halogen-free cable; this construction contains PVC insulation.
  • Plan installation at 0 °C or above and confirm the pump-entry sealing system.

PVC insulation and PE sheath selection

PVC insulation and PE sheath selection
Selection pointDesign input
3G or 4GMatch the motor connection to the listed core colours and protective conductor.
Circular entryCheck the nominal cable diameter and the seal’s applicable compression range.
InstallationHandle and install at 0 °C or above; observe the 70 °C conductor rating.
Material selectionPE is the outer sheath; the complete cable contains PVC insulation. Select a separate LSZH construction where required.

Related selection resources

Specifications

Specifications

Electrical and operating parameters
ParameterValue
Rated voltage U₀/U0.6/1 kV
ConductorPlain flexible copper, Class 5
Insulation and sheathPVC core insulation and a bright blue polyethylene outer sheath
Maximum conductor temperature70 °C
Ambient / handling conditions−40 to +50 °C ambient; installation minimum 0 °C
Water depth and water temperatureProject operating conditions reviewed with the enquiry.

The dimensions are nominal values for the four listed constructions. Provide motor current, route length and installation method for conductor sizing.

PVC/PE drinking-water pump cable dimensions and electrical data

PVC/PE drinking-water pump cable configuration table
Configuration (mm²)Nominal insulation diameter (mm)Nominal OD (mm)Approximate mass (kg/km)Maximum tensile force (N)
PVC/PE pump cable 3G1.53.110.111367
PVC/PE pump cable 4G1.53.111.114190
PVC/PE pump cable 3G2.53.611.5157110
PVC/PE pump cable 4G2.53.612.6196150
Standards

Standards

Technical references and test conditions for the specified construction.

Standards and test references
ItemReference
ConductorIEC 60228, Class 5
Voltage test3.5 kV

Specify the project’s drinking-water contact requirements for the complete cable and wetted accessories with the enquiry.

For conductor classes and nominal metric cross-sections, see the IEC 60228 standard scope.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.