RG316, RG142, RG178, RG179, RG188 & RG400 Solid-PTFE High-Temp RF Coaxial Cable
RG316, RG142, RG178, RG179, RG188 and RG400 high-temperature solid-PTFE dielectric RF coaxial cables plus M17/176-00002 77 Ohm PFA twinax bus cable (TF-RG316-RG142-RG400) are engineered to MIL-DTL-17 physical and VSWR/attenuation parameters (-55/-90 °C to +200/+250 °C, DC to 12.4 GHz). Supplied with silver-plated copper-clad steel (SCCS) or 19-strand SPC center conductors, single/double silver braids and FEP, PFA or PTFE jackets on 305 m / 300 m reels (non-QPL commercial supply).
RG316, RG142, RG178, RG179, RG188 and RG400 solid-PTFE fluoropolymer RF coaxial cables and M17/176-00002 77 Ohm twinax cables transmit high-power RF and high-frequency telemetry from -55 °C (-90 °C static) up to +250 °C, spanning 1.80 mm subminiature RG178 B/U PCB jumpers up to 4.95 mm double-braided 1,900 V RMS RG142 B/U and RG400 /U transmitter lines up to 12.4 GHz.
Standard polyethylene (RG58 / RG174) coaxial dielectrics soften above +80 °C, deform when bent near hot RF power amplifiers and melt instantly during SMA or TNC solder assembly. Replacing PE/PVC with solid paste-extruded virgin PTFE (69.5 % velocity of propagation, 96.5 pF/m on 50 Ohm models) plus silver-plated copper braids and translucent FEP, PFA or sintered PTFE outer jackets enables 3x–4x higher CW RF power handling in half the cross-sectional diameter.
Choose RG178 (1.8 mm) or RG316 (2.5 mm) for compact internal RF racks, upgrade to double-braided M17/152 (RG316-DS), RG142 (solid SCCS) or non-magnetic 19-strand SPC RG400 for > 90 dB shielding up to 12.4 GHz, or select 75 Ohm RG179 and 77 Ohm M17/176-00002 PFA twinax (commercial non-QPL supply, MOQ 305 m / 300 m reels, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
RG316, RG142, RG178 & RG400 Solid-PTFE Coax Construction
Extruded on tight-concentricity solid-PTFE lines with inline laser capacitance/diameter control to eliminate impedance spikes and VSWR suck-outs across swept RF bands.

| Component | Material and construction |
|---|---|
| 1. Silver-Plated Center Conductor (SCCS or Stranded SPC) | High-tensile silver-plated copper-clad steel (SCCS on RG178, RG179, RG188, RG316, RG142) or low-PIM non-magnetic 19-strand silver-plated copper (CuAg on RG400 /U; twin silver-plated alloy twisted pair on M17/176-00002). |
| 2. Precision Solid-PTFE Fluoropolymer Dielectric | High-density extruded solid virgin polytetrafluoroethylene core (dielectric constant 2.05, 69.5 % VoP) immune to solder-iron heat and high CW RF electric fields. |
| 3. Single or Double Silver-Plated Copper RF Braid Shield | High-coverage >= 90–95 % single SPC braid (RG178, RG179, RG188, RG316) or dual counter-woven SPC braids (M17/152 RG316-DS, RG142 B/U, RG400 /U) for > 90 dB RF isolation. |
| 4. Extruded FEP (+200 °C), PFA (+250 °C) or PTFE (+250 °C) Jacket | Smooth translucent tan/brown FEP jacket, extended-temperature PFA jacket (M17/93-00001 / M17/176-00002) or flexible white fused PTFE tape jacket (RG188 A/U). |
MIL-DTL-17 & RG Coaxial Designation Breakdown
- RG178 / RG316 / RG188: Subminiature 50 Ohm single-braid solid-PTFE coax: 1.80 mm FEP (RG178), 2.49 mm FEP (RG316) or 2.54 mm +250 °C PTFE (RG188)
- RG316-DS (M17/152): 2.90 mm double-silver-braided 50 Ohm solid-PTFE coax swept to 12.4 GHz
- RG142 B/U vs RG400 /U: 4.95 mm double-braided 50 Ohm coax: solid SCCS center (RG142) vs non-magnetic 19-strand CuAg center (RG400)
- RG179 B/U / RG180 B/U: 75 Ohm (RG179, 2.54 mm) and 95 Ohm (RG180, 3.58 mm) high-temperature solid-PTFE coax
- M17/176-00002: 77 Ohm +200 °C PFA-insulated/jacketed shielded twisted-pair twinax data-bus cable
RG316 & RG400 RF Plasma, MRI, Telecom & 1553B Bus Duty
Engineered for industrial RF plasma generators, medical imaging, telecommunications, downhole telemetry and commercial avionics/test systems.

- Semiconductor 13.56 MHz / 27.12 MHz / 60 MHz RF plasma etch & PECVD matching-network jumpers and industrial dielectric/induction heating exciters.
- MRI non-magnetic RF receive/transmit coil interconnects (non-magnetic 19-strand CuAg RG400 /U) and surgical RF ablation / laser power cabinets.
- Cellular base-station combiners, radar/SATCOM indoor/outdoor IF/RF jumpers, GPS/GNSS antenna feeds and automated ATE rack interconnects.
- 75 Ohm high-temp video/clock distribution (RG179 B/U) and 77 Ohm MIL-STD-1553B style redundant serial data buses (M17/176-00002 PFA twinax).
RG316 vs RG316-DS vs RG142 B/U vs RG400 /U Matrix
| Coaxial Model | OD & Shielding | Center Conductor Physics | Best RF Engineering Use |
|---|---|---|---|
| RG316 /U (2.49 mm) | Single SPC braid (~55 dB) | 7-strand SCCS (high tensile) | Compact PCB-to-panel SMA/MCX jumpers up to 3 GHz |
| RG316-DS / M17/152 (2.90 mm) | Double SPC braid (> 85 dB) | 7-strand SCCS | Dense multi-channel racks & swept jumpers up to 12.4 GHz |
| RG142 B/U (4.95 mm) | Double SPC braid (> 90 dB) | Solid 0.94 mm SCCS | Fixed high-power CW RF cabinet runs up to 12.4 GHz |
| RG400 /U (4.95 mm) | Double SPC braid (> 90 dB) | 19-strand non-magnetic CuAg | MRI coils, flexing jumpers, low-PIM & vibration racks |
Notice: RG316 and RG316-DS have different braid ODs (2.49 mm vs 2.90 mm) and require distinct SMA/BNC crimp ferrule sizes!
RG316, RG142 & MIL-DTL-17 Coaxial Cable RFQ Checklist
- Exact RG or M17 reference (RG178, M17/93-00001 PFA, RG188, RG316, RG316-DS M17/152, RG142, RG400, RG393, RG179 75 Ohm or M17/176-00002 77 Ohm twinax).
- Operating frequency band, CW RF power (if > 100 W) and whether non-magnetic CuAg (RG400) is required instead of SCCS (RG142).
- Jacket material (+200 °C FEP, +230 °C PFA or +250 °C PTFE tape) and confirmation of commercial non-QPL supply.
- Continuous reel quantity (MOQ 305 m / 1,000 ft or 300 m per model, 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Fluoropolymer, Data & RF Coaxial Cables
- Compare 50/75/100/120 Ohm Controlled-Impedance FEP/PFA Twisted-Pair Cable
- Pair with AS22759 / M22759 PTFE & XL-ETFE Chassis Wire
- Pair with MIL-W-16878 Type ET, E & EE Sintered PTFE Hook-Up Wire
- Engineering guide: PTFE vs FEP vs PFA dielectric & thermal properties
RG316, RG142, RG178 & RG400 Solid-PTFE Coaxial FAQ
What is the difference between RG142 B/U and RG400 /U solid-PTFE coaxial cable?
Center conductor metallurgy and flexibility: both are 50 Ohm, 4.95 mm OD double-silver-braided FEP-jacketed cables, but RG142 uses a rigid magnetic solid silver-plated copper-clad steel (SCCS) center wire whereas RG400 uses a flexible, non-magnetic 19-strand silver-plated copper (CuAg) conductor with lower passive intermodulation (PIM) and MRI compatibility.
When should I upgrade from standard RG316 to double-shielded RG316-DS (M17/152-00001)?
Upgrade to RG316-DS whenever RF isolation above 60 dB or operating frequencies between 3 GHz and 12.4 GHz are required; the second silver-plated copper braid raises shielding effectiveness above 85–90 dB with only a 0.41 mm OD increase.
Why do solid-PTFE RG316 and RG400 cables handle 3x–4x more RF power than RG174 or RG58?
2 thermal factors: solid PTFE withstands +200 °C (+250 °C on RG188) dielectric core temperatures vs +80 °C on polyethylene (RG58/RG174), and PTFE's ultra-low < 0.0002 loss tangent generates minimal dielectric heating at VHF/UHF/microwave frequencies.
Are TEBAOFLEX RG316, RG142, RG178 and RG400 cables U.S. DoD MIL-DTL-17 QPL listed?
No — TEBAOFLEX manufactures commercial/industrial solid-PTFE RF coaxial and M17/176 twinax cables engineered to MIL-DTL-17 physical, capacitance, dielectric withstand and attenuation specifications (U.S. DoD QPL listing is not claimed).
What is the minimum order quantity and delivery time for RG316, RG142 and RG400 bulk reels?
305 m (1,000 ft) or 300 m continuous reels per coaxial type, manufactured with inline capacitance/VSWR quality control in 7 to 45 working days.
MIL-DTL-17 50 Ω, 75 Ω & 77 Ω Coaxial & Twinax Schedule
RG316 & RG400 Impedance, Voltage, Attenuation & Reel Summary
- Complete 50 Ω, 75 Ω & 77 Ω lineup: Covers 50 Ω RG178, RG188, RG316, double-shield RG316-DS (M17/152), RG142 and RG400, 75 Ω RG179, and 77 Ω M17/176-00002 MIL-STD-1553B twinax
- Precision solid-PTFE dielectric: Extruded solid virgin PTFE core (epsilon_r = 2.05, velocity 69.5 %) will not melt during SMA/BNC/TNC/N connector center-pin soldering or +200 °C RF power heating
- Single & double silver-plated shields: Single SPC braid on miniature RG178/RG316 or >= 95 dB double silver-plated copper braids on RG316-DS, RG142 B/U and low-intermodulation RG400 /U
- FEP (+200 °C), PFA & PTFE (+250 °C): Translucent amber-tan FEP jacket (+200 °C), chemical/radiation-upgraded PFA jacket (M17/93-00001, +230/+250 °C) or lapped white PTFE jacket (RG188 A/U, +250 °C)
- Non-QPL OEM 305 m / 300 m reels: Engineered to MIL-DTL-17 swept VSWR & attenuation tables (U.S. DoD QPL listing not claimed); 305 m (1,000 ft) / 300 m reels in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 1000 V RMS on RG178 and M17/176 twinax, 1200 V RMS on RG316 / RG188 / RG179, and 1900 V RMS max operating voltage on RG142 and RG400 |
| Impedance and capacitance | 50 +/- 2 Ohm (96.5 pF/m, 69.5% VoP) on RG178/188/316/142/400; 75 +/- 3 Ohm (63.6 pF/m) on RG179; 77 +/- 7 Ohm (62.3 pF/m) on M17/176-00002 twinax |
| Frequency and temperature span | DC to 3 GHz (RG178/316/188) and DC to 12.4 GHz (double-shield M17/152, RG142, RG400); -55 C (-90 C static) to +200 C (FEP) or +250 C (PFA/PTFE) |
| Shielding and connector fit | Single or dual silver-plated copper braids matching standard industry crimp/solder SMA, SMB, MCX, MMCX, BNC, TNC and Type N RF connectors |
| Standard put-up and lead time | 305 m (1000 ft) or 300 m minimum order continuous factory reels delivered in 7 to 45 working days |
| Specification scope note | Commercial/industrial solid-PTFE coaxial and twinax cables engineered to MIL-DTL-17 parameters; U.S. DoD QPL listing is not claimed |
| Flame and fluid immunity | Fluoropolymer FEP/PFA/PTFE jackets pass UL VW-1 / IEC 60332-1-2 flame tests and resist fluxes, solvents, fuels, hydraulic oils and UV |
RG316, RG142, RG178, RG179, RG188, RG400 & M17/176 Coaxial Schedule
| Model & M17 Reference | Impedance / Max. Freq. | Center Conductor | Dielectric Ø / Shield | Jacket & Max. Temp. | Nom. OD (mm / in) | Atten. @ 400 MHz / 1 GHz (dB/100 m) | Standard Reel MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| MIL-DTL-17 RG178 B/U (M17/93) | 50 Ω / 3.0 GHz | 7x0.10 mm SCCS | 0.84 mm / 1x SPC | FEP (+200 °C) | 1.80 / 0.071 | 108 / 171 | 305 m / 300 m | Request this size |
| MIL-DTL-17 M17/93-00001 (RG178 PFA) | 50 Ω / 3.0 GHz | 7x0.10 mm SCCS | 0.84 mm / 1x SPC | PFA (+230 °C) | 1.80 / 0.071 | 108 / 171 | 305 m / 300 m | Request this size |
| MIL-DTL-17 RG188 A/U | 50 Ω / 3.0 GHz | 7x0.17 mm SCCS | 1.52 mm / 1x SPC | PTFE Tape (+250 °C) | 2.54 / 0.100 | 69 / 125 | 305 m / 300 m | Request this size |
| MIL-DTL-17 RG316 /U (M17/113) | 50 Ω / 3.0 GHz | 7x0.17 mm SCCS | 1.52 mm / 1x SPC | FEP (+200 °C) | 2.49 / 0.098 | 69 / 125 | 305 m / 300 m | Request this size |
| MIL-DTL-17 RG316-DS (M17/152-00001) | 50 Ω / 12.4 GHz | 7x0.17 mm SCCS | 1.52 mm / 2x SPC | FEP (+200 °C) | 2.90 / 0.114 | 78 / 131 | 305 m / 300 m | Request this size |
| MIL-DTL-17 RG303 /U (M17/111) | 50 Ω / 3.0 GHz | Solid 0.94 mm SCCS | 2.95 mm / 1x SPC | FEP (+200 °C) | 4.32 / 0.170 | 26 / 49 | 305 m / 300 m | Request this size |
| MIL-DTL-17 RG142 B/U (M17/60) | 50 Ω / 12.4 GHz | Solid 0.94 mm SCCS | 2.95 mm / 2x SPC | FEP (+200 °C) | 4.95 / 0.195 | 38 / 62 | 305 m / 300 m | Request this size |
| MIL-DTL-17 RG400 /U (M17/128) | 50 Ω / 12.4 GHz | 19x0.20 mm CuAg | 2.95 mm / 2x SPC | FEP (+200 °C) | 4.95 / 0.195 | 34 / 56 | 305 m / 300 m | Request this size |
| MIL-DTL-17 RG393 /U (M17/127) | 50 Ω / 11.0 GHz | 7x0.79 mm CuAg | 7.24 mm / 2x SPC | FEP (+200 °C) | 9.91 / 0.390 | 16 / 29 | 300 m reel | Request this size |
| MIL-DTL-17 RG179 B/U (M17/94) | 75 Ω / 1.0 GHz | 7x0.10 mm SCCS | 1.60 mm / 1x SPC | FEP (+200 °C) | 2.54 / 0.100 | 69 / — | 305 m / 300 m | Request this size |
| MIL-DTL-17 RG180 B/U (M17/95) | 95 Ω / 1.0 GHz | 7x0.10 mm SCCS | 2.59 mm / 1x SPC | FEP (+200 °C) | 3.58 / 0.141 | 56 / — | 305 m / 300 m | Request this size |
| MIL-DTL-17 M17/176-00002 Twinax | 77 Ω / Data Bus | 2x (19/37 Alloy) | Pair PFA / 1x Braid | Blue PFA (+200 °C) | 3.28 / 0.129 | 46 @ 10 MHz | 305 m / 300 m | Request this size |
ASCII part references for BOM entry: TF-RG178-FEP, TF-M17-93-00001-PFA, TF-RG188-PTFE, TF-RG316-FEP, TF-RG316DS-M17-152, TF-RG142B-FEP, TF-RG400-FEP, TF-RG179B-75OHM, TF-M17-176-00002.
Engineering note: RG142 B/U and RG400 /U share identical 4.95 mm (0.195 in) outer dimensions and double SPC shields, but RG400 replaces RG142's magnetic solid copper-clad steel center wire with non-magnetic 19-strand silver-plated copper for flexing, MRI and low-PIM RF service.
MIL-DTL-17, MIL-STD-1553B & Flame Reference Standards
| Standard or specification | Application |
|---|---|
| MIL-DTL-17 (Superseding MIL-C-17 Slash Reference Parameters) | Dimensional tolerances, 50/75/77/95 Ohm impedance, capacitance, dielectric withstand (2,000–5,000 V RMS) and swept VSWR/attenuation benchmarks (commercial non-QPL manufacture). |
| MIL-STD-1553B (M17/176-00002 Twinax Bus) | 77 Ohm +/- 7 Ohm differential impedance and 1 MHz Manchester-coded data-bus physical layer geometry. |
| IEC 60332-1-2 / UL VW-1 | Vertical single-cable flame-retardant fluoropolymer jacket performance. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and RF impedance/attenuation test reports
IEC 60332-1-2 — Vertical flame propagation test for single insulated wires and cables
ASTM B298 — Standard Specification for Silver-Coated Soft Copper Wire
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
UL 21618 Screened FEP Data Cable & 260 °C FEP/PFA Controlled-Impedance Cable
A related cable option for a different application or duty profile.
View productAS22759 / M22759 Extruded PTFE, ETFE & XL-ETFE High-Temp OEM Equipment Wire
A related cable option for a different application or duty profile.
View productMIL-W-16878 / NEMA HP3 Type ET, E & EE Extruded PTFE Equipment Wire (250–1000 V)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.