SIMH FE180 PH120 Fire-Resistant Silicone Power & Control Cable (300/500 V, 200 °C)
SIMH FE180 PH120 fire-resistant all-silicone power and control cables (300/500 V) combine IEC 60228 Class 5 copper conductors (2×0.75 mm² to 4×4 mm²) with ceramifying EI2 silicone core insulation and a safety-orange EM9 silicone outer sheath (-60 °C to +200 °C), maintaining 180-minute insulation integrity (IEC 60331-11 FE180) and 120-minute fire-with-shock circuit survival (EN 50200 PH120).
SIMH FE180 PH120 fire-resistant silicone cables solve a critical dual hazard that ordinary LSZH fire-survival cables cannot survive: continuous ambient heat up to +200 °C (down to -60 °C) combined with emergency circuit integrity during a hydrocarbon or electrical fire, covering 2×0.75 mm² to 4×4 mm² (6.2 mm to 12.6 mm nominal OD, 54.4 kg/km to 296.2 kg/km) at 300/500 V.
Conventional building fire-alarm cables such as LIHH FE180 or (N)HXH FE180 use thermoplastic polyolefin LSZH outer jackets limited to +70 °C or +90 °C ambient—meaning they soften, crack and fail prematurely beside steelmaking ladles, rotary cement kilns, glass tanks or marine boiler uptakes. SIMH FE180 PH120 replaces thermoplastic jacketing with cross-linked EM9 silicone compound over ceramifying EI2 silicone core insulation and flexible Class 5 copper strands, passing IEC 60331-11 (FE180 180-minute flame insulation integrity) and EN 50200 (PH120 120-minute flame plus mechanical shock).
Specify SIMH FE180 PH120 whenever emergency lighting, damper actuators, shut-off valves or furnace safety interlocks run through +90 °C to +200 °C hot industrial zones; select LIHH FE180 for normal-ambient (-30 to +90 °C) public-building fire alarms, or SiHF-P galvanized steel-braided silicone cable where heavy mechanical impact dominates without PH120 fire-circuit mandates (MOQ 50 m, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
SIMH FE180 PH120 All-Silicone Fire-Resistant Cable Construction
Every SIMH FE180 PH120 multicore cable uses all-elastomeric ceramifying silicone compounds inside and out so thermal cycling between -60 °C and +200 °C never embrittles the fire barrier.

| Component | Material and construction |
|---|---|
| 1. Flexible Copper Conductors (IEC 60228 / HD 383 Class 5) | Fine-stranded annealed bare copper conductors per HD 383 / IEC 60228 Class 5 (0.75 mm² to 4.0 mm²; tinned copper optional for corrosive furnace fumes). |
| 2. Ceramifying Silicone Compound Core Insulation (HD 22.1 EI2) | High-purity fire-resistant silicone elastomer Type EI2 forming a cohesive, non-conductive SiO2 ceramic ash shell around each conductor during 750–850 °C flame exposure. |
| 3. Core Identification & Concentric Lay-Up | Colour-coded or white number-printed cores per DIN VDE 0293-308 (optional green-yellow protective earth core in 3G/4G/5G layouts) laid in short pitch with halogen-free mineral/silicone bedding. |
| 4. Safety-Orange Silicone Compound Outer Sheath (HD 22.1 EM9) | Tear- and thermal-shock-resistant cross-linked silicone outer sheath Type EM9 in high-visibility orange, rated -60 °C to +200 °C and halogen-free per IEC 60754-1/2. |
SIMH FE180 PH120 Designation & Fire-Integrity Code Breakdown
- SI: All-silicone elastomer design: HD 22.1 Type EI2 ceramifying silicone core insulation plus Type EM9 silicone outer sheath
- MH: Halogen-free multicore industrial safety cable emitting zero corrosive acid gases (IEC 60754-1/2)
- FE180: 180-minute insulation integrity under direct >= 750 °C flame exposure per IEC 60331-11 / VDE 0472-814
- PH120: 120-minute emergency circuit integrity under 830 °C fire plus mechanical shock per EN 50200
- 2x0.75 – 4x4 (or G): Core count and conductor cross-section in mm² (G denotes inclusion of a green-yellow protective earth core)
SIMH FE180 PH120 Steelworks, Kiln & Marine Hot-Zone Applications
Install SIMH FE180 PH120 across extreme-temperature industrial plants, transport hubs and marine/aerospace test facilities where circuits must keep operating both at +200 °C service heat and under fire conditions.

- Iron and steel continuous-casting bays, blast-furnace stoves, rolling mills and ladle-car emergency stop, damper and evacuation lighting circuits.
- Float-glass melting furnaces, ceramic tunnel kilns, brickworks and rotary cement clinker coolers subject to radiant heat cycling.
- Shipbuilding engine/boiler room uptakes, aerospace propulsion test cells and power-station turbine hoods requiring halogen-free fire-integrity leads.
- High-wattage industrial tunnel/foundry emergency luminaires, smoke-extraction louver actuators and high-temperature safety interlock loops.
SIMH FE180 PH120 vs LIHH FE180 vs SiHF vs SiHF-P Armoured Cable
| Cable Type | Ambient Temp Envelope | Core / Outer Sheath | When to Specify |
|---|---|---|---|
| SIMH FE180 PH120 (this page) | -60 °C to +200 °C | Ceramifying EI2 silicone + orange EM9 silicone | Hot steel/glass/cement zones needing BOTH +200 °C service & FE180/PH120 survival |
| LIHH FE180 / LIHCH FE180 | -30 °C to +90 °C | Silicone FE180 cores + orange LSZH-HFFR polyolefin | Subways, hospitals, tunnels & commercial fire alarms at normal ambient |
| SiHF / H05SS-F Silicone Cable | -60 °C to +180 °C | Standard EI2 silicone + red-brown silicone sheath | General 180 °C furnace/oven power & control without PH120 shock mandate |
| SiHF-P / SiHF-GL-P Armoured | -60 °C to +180 °C | Silicone + glass tape + galvanized steel wire braid | Foundry & steelworks runs exposed to heavy mechanical impact or slag splash |
Choose SIMH FE180 PH120 whenever ambient heat exceeds +90 °C (where thermoplastic LSZH jackets fail) AND emergency circuits must survive fire.
SIMH FE180 PH120 Fire-Resistant Silicone Cable RFQ Checklist
- Core count and cross-section (for example 2x1.5 mm², 3G1.5 mm², 4G2.5 mm² or 4G4 mm²; state whether green-yellow PE core is required).
- Conductor finish: standard Class 5 bare copper or optional Class 5 tinned copper for high-humidity/acidic furnace atmospheres.
- Fire-circuit specification: IEC 60331-11 FE180, EN 50200 PH120, or optional metallic braid / foil screen if VFD/EMC shielding is needed.
- Maximum continuous ambient temperature (-60 °C to +200 °C) and stainless-steel fire-cleat spacing.
- Required drum cut lengths (MOQ 50 m) and target project delivery window (7 to 45 working days).
Related selection resources
- High-temperature and fire-resistant silicone cable catalog
- Custom steelworks, kiln and high-temperature cable engineering
- SiHF-J 180 °C Multicore Flexible Silicone Power & Control Cable
- SiHF-P / SiHF-GL-P Galvanized Steel-Braided Armoured Silicone Cable
- Multicore 450 °C Mica-Glass Ultra-High-Temperature Cable
- Engineering guide: High-temperature elastomer vs mica insulation limits
SIMH FE180 PH120 Fire-Resistant Cable Frequently Asked Questions
What do FE180 and PH120 mean on SIMH FE180 PH120 silicone cables?
FE180 indicates the ceramifying EI2 silicone core insulation maintains electrical insulation integrity for 180 minutes in a >= 750 °C flame (IEC 60331-11 / VDE 0472-814), while PH120 confirms the complete cable maintains continuity and insulation for 120 minutes under simultaneous 830 °C flame and mechanical shock impacts per EN 50200.
How does SIMH FE180 PH120 differ from LIHH FE180 fire alarm cable?
SIMH FE180 PH120 uses cross-linked silicone rubber for BOTH core insulation (EI2) and outer sheath (EM9), allowing continuous operation from -60 °C to +200 °C in steelworks and kilns; LIHH FE180 pairs silicone cores with a thermoplastic LSZH-HFFR outer sheath limited to -30 °C to +90 °C for public buildings and tunnels.
Does SIMH FE180 PH120 require special cable cleats to achieve circuit integrity in a fire?
Yes. Because standard nylon ties and plastic conduits melt well below 200 °C, SIMH FE180 PH120 runs must be supported on steel trays or walls using stainless-steel fire-rated cleats at 300 mm to 400 mm centres and terminated in porcelain/ceramic terminal blocks.
Can SIMH FE180 PH120 be manufactured with a green-yellow protective earth core or tinned copper?
Yes. Every 3-core, 4-core and custom 5-to-12-core SIMH FE180 PH120 configuration can be supplied as -J with a green-yellow earth core (DIN VDE 0293-308) and with IEC 60228 Class 5 tinned copper strands for corrosive chemical or marine atmospheres.
What is the minimum order quantity and delivery lead time for SIMH FE180 PH120?
Minimum order quantity is 50 m per cross-section with a manufacturing lead time of 7 to 45 working days, packed on export-fumigated reels or coils.
SIMH FE180 PH120 Dimensional, Copper Factor & Weight Schedule
SIMH FE180 PH120 Key Voltage, Fire Class, Thermal & MOQ Summary
- Dual +200 °C & fire survival: All-silicone EI2 core + orange EM9 outer jacket operates continuously from -60 °C to +200 °C while passing FE180 and PH120 fire-integrity tests
- Ceramifying SiO2 fire barrier: Under direct flame (>= 750–830 °C), silicone layers convert into a protective insulating silicon-dioxide carapace instead of melting or shorting
- 15 industrial power/control sizes: 2-, 3- and 4-core builds across 0.75, 1.0, 1.5, 2.5 and 4.0 mm² (6.2 mm to 12.6 mm OD; 54.4 to 296.2 kg/km), expandable to 5G–12G on request
- Zero halogen & low corrosivity: 100% halogen-free per IEC 60754-1 and IEC 60754-2 with DIN VDE 0293-308 colour or number-coded cores
- Project cut-length MOQ 50 m: Supplied from 50 m minimum order quantity on wooden drums or coils within 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 300/500 V AC (Uo/U) power and control rating with 2000 V AC 50 Hz routine dielectric test |
| Fire integrity performance | FE180 180-minute insulation integrity (IEC 60331-11) and PH120 120-minute circuit integrity under fire with mechanical shock (EN 50200) |
| Continuous temperature range | -60 C to +200 C ambient and conductor operating envelope across extreme thermal shock cycles |
| Insulation and sheath materials | Ceramifying silicone rubber core insulation (HD 22.1 EI2) under a safety-orange cross-linked silicone outer sheath (HD 22.1 EM9) |
| Core range, MOQ and lead time | 2x0.75 mm2 to 4x4 mm2 standard schedule (6.2 to 12.6 mm OD) with MOQ 50 m and 7 to 45 working days manufacturing lead time |
| Halogen-free and flame tests | Halogen-free and low-corrosivity gases per IEC 60754-1 and IEC 60754-2; flame-retardant per IEC 60332-1-2 |
| Minimum bending radius | 7.5x overall cable diameter for fixed fire-cleated tray/conduit routing and 12x OD during installation pulling |
SIMH FE180 PH120 Multicore Fire-Resistant Silicone Dimensional & Weight Schedule
| Model & Core Configuration | Fire & Thermal Class | Approx. OD (mm) | Copper Factor (kg/km) | Approx. Cable Weight (kg/km) | Sheath Material & Colour | Next step |
|---|---|---|---|---|---|---|
| SIMH FE180 PH120 2x0.75 mm² | FE180 / PH120 (-60/+200 °C) | 6.2 | 14.4 | 54.4 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 3x0.75 mm² | FE180 / PH120 (-60/+200 °C) | 6.6 | 21.6 | 66.0 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 4x0.75 mm² | FE180 / PH120 (-60/+200 °C) | 7.6 | 29.0 | 86.2 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 2x1.0 mm² | FE180 / PH120 (-60/+200 °C) | 6.6 | 19.2 | 63.4 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 3x1.0 mm² | FE180 / PH120 (-60/+200 °C) | 7.4 | 29.0 | 84.2 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 4x1.0 mm² | FE180 / PH120 (-60/+200 °C) | 8.0 | 38.4 | 101.2 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 2x1.5 mm² | FE180 / PH120 (-60/+200 °C) | 7.4 | 29.0 | 82.7 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 3x1.5 mm² | FE180 / PH120 (-60/+200 °C) | 7.9 | 43.0 | 101.8 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 4x1.5 mm² | FE180 / PH120 (-60/+200 °C) | 8.5 | 58.0 | 123.5 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 2x2.5 mm² | FE180 / PH120 (-60/+200 °C) | 9.1 | 48.0 | 127.1 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 3x2.5 mm² | FE180 / PH120 (-60/+200 °C) | 9.7 | 72.0 | 157.0 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 4x2.5 mm² | FE180 / PH120 (-60/+200 °C) | 10.5 | 96.0 | 191.0 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 2x4 mm² | FE180 / PH120 (-60/+200 °C) | 10.6 | 77.0 | 181.3 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 3x4 mm² | FE180 / PH120 (-60/+200 °C) | 11.3 | 115.0 | 227.5 | EM9 Silicone (Orange) | Request this size |
| SIMH FE180 PH120 4x4 mm² | FE180 / PH120 (-60/+200 °C) | 12.6 | 154.0 | 296.2 | EM9 Silicone (Orange) | Request this size |
All 3-core and 4-core sizes are available either without green-yellow earth (3x / 4x) or with green-yellow protective earth conductor (3G / 4G per DIN VDE 0293-308), plus extended 5G1.5 to 12G2.5 and 6 to 16 mm² builds to order; final values are confirmed on the quotation drawing.
To preserve PH120 circuit survival during a structural fire, support SIMH FE180 PH120 cables with fire-rated stainless-steel cleats and ceramic terminal blocks rather than plastic cable ties that melt above +150 °C.
Minimum order quantity is 50 m with a production lead time of 7 to 45 working days, shipped on export wooden drums with factory dielectric and construction verification records.
ASCII part references for BOM and ERP entry: TF-SIMH-FE180-2X0.75; TF-SIMH-FE180-3G0.75; TF-SIMH-FE180-2X1.0; TF-SIMH-FE180-3G1.0; TF-SIMH-FE180-2X1.5; TF-SIMH-FE180-3G1.5; TF-SIMH-FE180-4G1.5; TF-SIMH-FE180-2X2.5; TF-SIMH-FE180-3G2.5; TF-SIMH-FE180-4G2.5; TF-SIMH-FE180-3G4; TF-SIMH-FE180-4G4.
SIMH FE180 PH120 IEC 60331-11, EN 50200 & HD 22.1 Standards
| Standard or specification | Application |
|---|---|
| IEC 60331-11 (FE180 Insulation Integrity) | Circuit-integrity verification under direct flame exposure at >= 750 °C for 180 minutes without conductor-to-conductor breakdown. |
| EN 50200 (PH120 Fire + Mechanical Shock) | 120-minute emergency circuit survival test combining 830 °C flame exposure with periodic mechanical impact on the mounting board. |
| CENELEC HD 22.1 S4 / EN 50363-1 & EN 50363-2-1 | Material requirements for EI2 silicone core insulation and EM9 tear-resistant silicone outer sheath compounds. |
| IEC 60332-1-2 & IEC 60754-1 / IEC 60754-2 | Vertical flame retardance and halogen-free non-corrosive smoke gas verification. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and routine HV dielectric test documentation
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
SiHF & SiHF-J Multi-Core Flexible Silicone Cable (300/500 V, 180 °C)
A related cable option for a different application or duty profile.
View productSiHF-P & SiHF/GLS-P GSWB Armoured Silicone Cable (300/500 V, 180 °C)
A related cable option for a different application or duty profile.
View productSiHFC & SiHF-C-Si EMC Screened Silicone Cable (300/500 V, 180 °C)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.