TGFLSH / TGFLSH2G 450/750 V Flat Hot Water Pump Cable
TGFLSH / TGFLSH2G are 450/750 V flat halogen-free hot-water pump cables with Class 5 tinned copper and SIR insulation.
- TGFLSH: EVA outer sheath
- TGFLSH2G: SIR outer sheath
- Separate conductor-temperature and flexible-use limits
- Flat entry and bending-plane coordination
Send the full designation, core count, conductor section, cable height and width, installed length and pump-entry drawing for a technical quotation.
TGFLSH and TGFLSH2G Flat Hot-Water Pump Connections
TGFLSH and TGFLSH2G are 450/750 V flat, halogen-free cables for hot-water submersible pumps and immersed electrical equipment under medium mechanical stress. Both use Class 5 tinned copper conductors with SIR silicone rubber insulation. TGFLSH has an EVA outer sheath; TGFLSH2G has an SIR outer sheath.
Select the sheath version before coordinating the pump entry. The two constructions have different conductor-temperature and flexible-use ambient limits, so the full designation matters when replacing a lead. Match the selected variant to the motor circuit, installation conditions and sealing materials.
A flat cable needs both height and width to fit the entry. Check the slot, sealing sleeve, clamp orientation and available bending plane together. Reserve separate fixed and flexible bend space, and support the cable independently from the pump lifting system. The flat arrangement is a geometry choice; the protective-conductor requirement follows the equipment drawing.
For industrial or well installations, include the actual water composition and treatment chemicals with the enquiry. Coordinate wet-to-dry transitions and termination space before choosing the installed length. Immersion depth and the permitted water-temperature limit are confirmed for the specified project. Use these cables in non-hazardous locations.
For TGFLSH or TGFLSH2G selection, explore the submersible pump cable range; for TGFLSH and TGFLSH2G entry planning, read the minimum bending radius guide.
Construction
The flat family uses parallel insulated conductors. Select the complete sheath version and the required protective-conductor arrangement.


| Element | TGFLSH | TGFLSH2G |
|---|---|---|
| Conductor | Class 5 flexible tinned copper | Class 5 flexible tinned copper |
| Core insulation | SIR silicone rubber | SIR silicone rubber |
| Outer sheath | EVA rubber compound | SIR silicone rubber |
| Core identification | DIN EN 50525-1; G configurations include a green/yellow protective conductor. | DIN EN 50525-1; G configurations include a green/yellow protective conductor. |
| Arrangement | Parallel insulated cores in a flat cable. | Parallel insulated cores in a flat cable. |
| Metallic screen | Unscreened | Unscreened |
Applications
Power connections to hot-water pumps and immersed electrical equipment in industrial, agricultural, indoor and outdoor supported installations under medium mechanical stress.

| Selection point | Requirement |
|---|---|
| Sheath selection | Choose TGFLSH with EVA or TGFLSH2G with SIR and use that variant’s conductor and ambient limits. |
| Entry geometry | Specify finished height and width, slot profile and seal compression for the selected flat construction. |
| Bending and support | Plan the flat-cable bending plane and support the cable independently from pump lifting equipment. |
| Water chemistry | State the actual hot-water composition and treatment chemicals for material selection. |
| Water service conditions | Confirm immersion depth and the permitted water-temperature limit with the project enquiry. |
| Location restriction | Not for explosion-hazardous areas. |
Specifications
Select the sheath variant first, then coordinate the electrical conditions, conductor temperature and installed flat-cable geometry.
| Parameter | Value or condition |
|---|---|
| Rated voltage U₀/U | 450/750 V |
| Conductor | Class 5 flexible tinned copper |
| Core insulation | SIR silicone rubber |
| Sheath options | TGFLSH: EVA; TGFLSH2G: SIR |
| Shape | Flat, 3–4 cores |
| Metallic screen | Unscreened |
| Parameter | Value or condition |
|---|---|
| Model | TGFLSH 450/750 V |
| Outer sheath | EVA |
| Maximum conductor temperature | 130 °C |
| Short-circuit conductor temperature / duration | 350 °C / maximum 5 s |
| Minimum ambient temperature, fixed | −50 °C |
| Minimum ambient temperature, flexible | −25 °C |
| Maximum AC operating voltage | 0.476/0.825 kV |
| Maximum DC operating voltage | 0.619/1.238 kV |
| AC test voltage — main cores | 2.5 kV / 15 minutes |
| Maximum conductor tensile stress | 15 N/mm² |
| Minimum bend radius, fixed | 3 × Dmax |
| Minimum bend radius, flexible | 4 × Dmax |
| Family range | 3–4 cores; cross-sections up to 240 mm². Select core count and cross-section together. |
| Parameter | Value or condition |
|---|---|
| Model | TGFLSH2G 450/750 V |
| Outer sheath | SIR |
| Maximum conductor temperature | 150 °C |
| Short-circuit conductor temperature / duration | 350 °C / maximum 5 s |
| Minimum ambient temperature, fixed | −50 °C |
| Minimum ambient temperature, flexible | −50 °C |
| Maximum AC operating voltage | 0.476/0.825 kV |
| Maximum DC operating voltage | 0.619/1.238 kV |
| AC test voltage — main cores | 2.5 kV / 15 minutes |
| Maximum conductor tensile stress | 15 N/mm² |
| Minimum bend radius, fixed | 3 × Dmax |
| Minimum bend radius, flexible | 4 × Dmax |
| Family range | 3–4 cores; cross-sections up to 240 mm². Select core count and cross-section together. |
| Parameter | Value or condition |
|---|---|
| Protected fixed AC application allowance | Up to 1000 V in protected fixed conduits, equipment, well installations or motor rotor circuits. |
| Protected fixed DC application allowance | Up to 750 V to earth under the same protected fixed conditions. |
| Motor-system AC test condition | 3 kV for maximum 3 minutes; distinct from the main-core cable test. |
| Flat-cable bending reference | Apply Dmax to the selected cable drawing; coordinate finished height, width and the bending plane with the pump entry. |
| Location restriction | Not for explosion-hazardous areas. |
Standards
| Reference | Application |
|---|---|
| EN 50525-2-21 | Construction reference: based on EN 50525-2-21. |
| DIN EN 60228 | Class 5 conductor reference. |
| DIN EN 50525-1 | Core identification reference. |
| DIN EN 50525-2-21 | Water-resistance reference. |
| DIN EN 50565-2 | General cable-use and installation guidance. |
| Main-core AC cable test | 2.5 kV for 15 minutes. |
| Motor-system AC test | 3 kV for maximum 3 minutes in the stated motor-test application. |
For conductor classes, see the IEC 60228 standard scope.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TGSH / TGSH2G Hot-Water Submersible Pump Cable 450/750 V
A related cable option for a different application or duty profile.
View productS07BBH2-F / S1BBH2-F Flat Drinking Water Pump Cable
A related cable option for a different application or duty profile.
View productTML Type B Round and Flat Submersible Pump Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.