Type 245UF Ultra-Flexible Mining Cable 1.1–3.3 kV
Type 245UF cable is an ultra-flexible 1.1–3.3 kV mining cable for longwall shearer cable chains.
- Three screened power cores, three earth conductors and three central pilots.
- Flexible tinned copper with EPR R-EP-90 insulation.
- Open-weave textile reinforcement and an HD-85-PCP sheath.
- 50–150 mm² power-conductor schedule.
- Maximum continuous conductor temperature: 90 °C.
- AS/NZS 1802 underground mining cable construction.
Type 245UF cable for longwall shearer cable chains
Type 245UF cable is an ultra-flexible underground mining power cable for longwall shearer cable chains. The 1.1 kV and 3.3 kV versions contain three semiconductive-screened phase cores, three earth conductors and three central extensible pilots in a reinforced round construction.
Flexible tinned-copper conductors, EPR R-EP-90 insulation and an HD-85-PCP sheath form the power-cable assembly. The earth conductors sit between the phase cores, while the three pilots run together through the centre for machine monitoring and control connections. Open-weave textile reinforcement lies beneath the outer sheath.
The UF size schedule covers 50, 70, 95, 120 and 150 mm² phase conductors. Each voltage grade has its own insulation thickness, overall diameter and cable mass. The Specifications section also gives the earth-conductor area, AC resistance, reactance, three-phase voltage drop and capacitance for each size.
These dimensions support cable-chain compartment, gland and termination selection. The UF designation identifies the ultra-flexible longwall cable-chain construction; the complete model, voltage and phase area identify the replacement cable. Three separate pilot conductors accommodate the machine’s monitoring and control circuit arrangement.
Browse the mining and tunnelling cable range or use the mining cable selection guide to compare equipment duties and installation methods.
Type 245UF cable construction
The three power cores form a triangular assembly. Three semiconductive-covered earth conductors occupy the outer interstices, and three extensible pilot conductors run together at the centre.

| Element | Construction |
|---|---|
| Power conductors | Three ultra-flexible tinned-copper conductors |
| Conductor screen | Semiconductive conductor screen on the 3.3 kV version |
| Insulation | EPR compound, R-EP-90 |
| Insulation screen | Semiconductive elastomer over each phase core |
| Phase identification | Printed core numbers on the black semiconductive insulation screen |
| Earth conductors | Three flexible earth conductors with semiconductive elastomer covering, located in the interstices |
| Pilots | Three extensible pilot conductors at the cable centre |
| Reinforcement | Open-weave textile reinforcement beneath the sheath |
| Outer sheath | Heavy-duty HD-85-PCP elastomer |
Longwall shearer and cable-chain applications
The UF construction serves moving underground connections where a shearer cable chain repeatedly guides the cable through a confined route.

- Longwall shearers: flexible power delivery along the moving machine route.
- Cable-chain installations: a supported cable path with compartment space selected from the size-specific diameter.
- Machine monitoring: three separate central pilots for the equipment control and monitoring arrangement.
Cable-chain and circuit arrangement
The size-specific cable diameter defines the space needed in the chain compartments and entry glands. Three separate pilots connect the monitoring and control circuits, with three earth conductors providing the earthing paths.
Compare the conventional construction in the Type 245 mining cable family. The UF version has its own longwall cable-chain construction and size schedule.
Type 245UF specifications and size schedule
| Parameter | Value |
|---|---|
| Voltage variants | Type 245.1 UF: 1.1 kV; Type 245.3 UF: 3.3 kV |
| Core arrangement | 3 power + 3 earth + 3 central pilot conductors |
| Power-conductor sizes | 50, 70, 95, 120 and 150 mm² |
| Maximum continuous conductor temperature | +90 °C |
| Minimum installation temperature | −25 °C |
Type 245.1 UF — 1.1 kV
| Configuration | Conductor diameter (mm) | Insulation (mm) | Earth area, each (mm²) | Sheath (mm) | Overall diameter (mm) | Approx. mass (kg/100 m) |
|---|---|---|---|---|---|---|
| Type 245.1 UF 50 mm² | 9.8 | 1.7 | 8 | 4.8 | 49.7 | 425 |
| Type 245.1 UF 70 mm² | 12.0 | 1.8 | 12.5 | 5.1 | 54.9 | 555 |
| Type 245.1 UF 95 mm² | 13.8 | 2.0 | 12.5 | 5.6 | 60.3 | 675 |
| Type 245.1 UF 120 mm² | 15.9 | 2.1 | 13.75 | 6.0 | 65.7 | 845 |
| Type 245.1 UF 150 mm² | 17.9 | 2.3 | 17 | 6.3 | 70.8 | 1010 |
| Configuration | AC resistance, 90 °C / 50 Hz (Ω/km) | Reactance, 50 Hz (Ω/km) | 3-phase voltage drop, 90 °C / 50 Hz (mV/A·m) | Capacitance to earth (µF/phase/km) |
|---|---|---|---|---|
| Type 245.1 UF 50 mm² | 0.523 | 0.114 | 0.927 | 0.544 |
| Type 245.1 UF 70 mm² | 0.346 | 0.107 | 0.627 | 0.614 |
| Type 245.1 UF 95 mm² | 0.271 | 0.103 | 0.502 | 0.630 |
| Type 245.1 UF 120 mm² | 0.210 | 0.0988 | 0.402 | 0.684 |
| Type 245.1 UF 150 mm² | 0.166 | 0.0956 | 0.332 | 0.698 |
Type 245.3 UF — 3.3 kV
| Configuration | Conductor diameter (mm) | Insulation (mm) | Earth area, each (mm²) | Sheath (mm) | Overall diameter (mm) | Approx. mass (kg/100 m) |
|---|---|---|---|---|---|---|
| Type 245.3 UF 50 mm² | 9.8 | 3.0 | 8 | 5.7 | 57.4 | 525 |
| Type 245.3 UF 70 mm² | 12.0 | 3.0 | 12.5 | 6.0 | 62.3 | 660 |
| Type 245.3 UF 95 mm² | 13.8 | 3.0 | 16 | 6.4 | 66.5 | 780 |
| Type 245.3 UF 120 mm² | 15.9 | 3.0 | 20 | 6.7 | 71.2 | 950 |
| Type 245.3 UF 150 mm² | 17.9 | 3.0 | 27 | 7.0 | 75.6 | 1120 |
| Configuration | AC resistance, 90 °C / 50 Hz (Ω/km) | Reactance, 50 Hz (Ω/km) | 3-phase voltage drop, 90 °C / 50 Hz (mV/A·m) | Capacitance to earth (µF/phase/km) |
|---|---|---|---|---|
| Type 245.3 UF 50 mm² | 0.523 | 0.121 | 0.930 | 0.359 |
| Type 245.3 UF 70 mm² | 0.346 | 0.113 | 0.630 | 0.418 |
| Type 245.3 UF 95 mm² | 0.271 | 0.108 | 0.505 | 0.467 |
| Type 245.3 UF 120 mm² | 0.210 | 0.103 | 0.405 | 0.525 |
| Type 245.3 UF 150 mm² | 0.166 | 0.0986 | 0.334 | 0.578 |
Dimensions are nominal and mass is approximate. Earth area is the area of each of the three earth conductors. AC resistance and three-phase voltage drop are stated at 90 °C and 50 Hz; reactance is stated at 50 Hz. Capacitance is per phase to earth per kilometre.
Voltage-grade dimensions
The 1.1 kV and 3.3 kV versions have different insulation thicknesses and overall dimensions at the same phase area. Each table groups the matching conductor, insulation, earth area, sheath thickness, diameter and mass for that voltage grade.
Type 245UF standards
AS/NZS 1802 covers reeling and trailing cables for underground coal mines.
- Cable construction: Type 245UF, with three screened phase cores, three earth conductors and three central pilots.
- Power-core insulation: EPR R-EP-90.
- Outer sheath: heavy-duty HD-85-PCP elastomer.
- Phase screening: semiconductive elastomer.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type 245 Flexible Rubber Mining Cable 1.1–6.6 kV
A related cable option for a different application or duty profile.
View productType 241SF Flexible Mining Cable 1.1/1.1–11/11 kV
A related cable option for a different application or duty profile.
View productTYPE275 1.1 kV Flexible Shuttle Car Mining Cable
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.