MINING & TUNNELING CABLES TEBAOFLEX

Type MP-GC EPR/CPE Mine Power Feeder Cable, 5–35 kV

Type MP-GC EPR-insulated cable for fixed mine power distribution. Three individually copper-tape-screened power cores, two earth conductors and an insulated ground-check core; CPE jacket at 5–35 kV, with separately specified EPR/PVC options at 25 and 35 kV.

Product information
SKU
TF-MIN-P1-M003
Brand
TEBAOFLEX
Product overview

Type MP-GC EPR/CPE mine feeder cable supplies fixed mine distribution circuits at 5, 8, 15, 25 and 35 kV. Its construction combines three individually screened copper power cores with two grounding conductors and an insulated ground-check conductor. EPR insulation and a thermosetting CPE jacket support permanent feeder connections between mine distribution equipment, including ducts, conduit, open air and suitably designed direct-burial routes. For a different material system, compare 15 kV MP-GC with XLPE insulation and a PVC jacket.

The ground-check core provides a separate circuit for the selected continuity-monitoring system; it does not replace the protective-earth conductors. Specify the feeder voltage, insulation level, conductor size and protection arrangement together. The published configurations use a 100% insulation level for grounded systems. Their current values also have different ambient-temperature bases: the 5–15 kV tables use 40°C, while the 25–35 kV tables use 30°C. Route conditions and installation grouping must be included in cable sizing.

This Class B feeder construction serves stationary distribution. For a moving shovel, dragline or continuously reeled machine circuit, compare SHD-GC cable for mobile mining equipment and specify the required movement duty. EPR/PVC variants at 25 and 35 kV are shown separately so the jacket and weight remain tied to the ordered construction. TEBAOFLEX supplies this family from a 50 m minimum order quantity, with a manufacturing lead time of 7–45 working days. Include the selected configuration, route and termination details with the enquiry.

Explore the mining and tunneling cable range for related configurations.

Construction

Construction

The representative MP-GC build has three screened power cores, two grounding conductors and one yellow-insulated ground-check conductor inside a taped round core. The CPE and PVC jacket variants retain separate ordering tables. The main image is a representative construction illustration.

Type MP-GC EPR/CPE Mine Power Feeder Cable, 5–35 kV construction
ComponentMaterial and construction
Power conductorsThree stranded copper conductors in a Class B fixed-feeder construction.
Conductor screenExtruded semiconducting layer over each power conductor.
Insulation90°C ethylene-propylene rubber (EPR); thickness follows the selected voltage table.
Insulation screenSemiconducting layer beneath an individual copper-tape metallic screen on each power core.
Protective-earth conductorsTwo uninsulated tinned-copper grounding conductors; their sizes are paired with the power conductors in each table.
Ground-check conductorOne 8 AWG, seven-wire copper conductor insulated with yellow polypropylene in the listed configurations.
AssemblyThe three power cores, grounding conductors and ground-check core are assembled with fillers as required and a binder/taped core.
Outer jacketMould-cured thermosetting CPE for the 5–35 kV tables; PVC for the separate 25 and 35 kV EPR/PVC tables. Black is the standard reference colour.
Applications

Applications

Select this family for permanent medium-voltage mine feeder routes. Coordinate the protective-earth and ground-check circuits with the mine distribution and protection design.

  • Fixed connections between mine substations, distribution units and load centres.
  • Duct, conduit and open-air feeder installations within the selected voltage rating.
  • Direct-buried feeder circuits in wet or dry locations, with route-specific thermal and mechanical design.
  • Supported vertical routes using a messenger and suitable mechanical support hardware; support spacing and tensile loads are design inputs.
  • Replacement of an EPR-insulated MP-GC feeder where voltage, jacket material, ground-check wiring and termination dimensions match the equipment specification.

For route and construction selection, see the medium-voltage mining cable selection guide.

Specifications

Specifications

Type MP-GC EPR/CPE Mine Power Feeder Cable, 5–35 kV technical data
ParameterValue
CPE-jacket voltage classes5, 8, 15, 25 and 35 kV
PVC-jacket EPR options25 and 35 kV; separate dimensions and weights
Insulation level in the tables100%, grounded-system reference
Maximum continuous conductor temperature90°C
Circuit arrangement3 power + 2 protective earth + 1 insulated ground check
Ground-check size in the tables8 AWG
Conductor dutyClass B fixed feeder; select a dedicated trailing design for continuous movement
Nominal outside-diameter tolerance+8% / −5% for the tabulated reference constructions
Minimum order quantity50 m
Manufacturing lead time7–45 working days
Type MP-GC EPR/CPE 5 kV — 100% insulation level; ampacity at 90°C conductor / 40°C ambient
Model and configuration: power + G + GCEPR insulation (mils)CPE jacket (mils)Nominal OD (in.)Approx. mass (lb/1,000 ft)Ampacity (A)
Type MP-GC EPR/CPE 3 × 4 AWG + 2 × 8 AWG G + 1 × 8 AWG GC901101.421441122
Type MP-GC EPR/CPE 3 × 2 AWG + 2 × 6 AWG G + 1 × 8 AWG GC901101.561827159
Type MP-GC EPR/CPE 3 × 1 AWG + 2 × 5 AWG G + 1 × 8 AWG GC901101.652168184
Type MP-GC EPR/CPE 3 × 1/0 AWG + 2 × 4 AWG G + 1 × 8 AWG GC901101.762602211
Type MP-GC EPR/CPE 3 × 2/0 AWG + 2 × 3 AWG G + 1 × 8 AWG GC901101.883010243
Type MP-GC EPR/CPE 3 × 4/0 AWG + 2 × 1 AWG G + 1 × 8 AWG GC901402.144190321
Type MP-GC EPR/CPE 3 × 250 kcmil + 2 × 1/0 AWG G + 1 × 8 AWG GC901402.234825355
Type MP-GC EPR/CPE 3 × 350 kcmil + 2 × 2/0 AWG G + 1 × 8 AWG GC901402.476062435
Type MP-GC EPR/CPE 3 × 500 kcmil + 2 × 4/0 AWG G + 1 × 8 AWG GC901402.708427536
Type MP-GC EPR/CPE 8 kV — 100% insulation level; ampacity at 90°C conductor / 40°C ambient
Model and configuration: power + G + GCEPR insulation (mils)CPE jacket (mils)Nominal OD (in.)Approx. mass (lb/1,000 ft)Ampacity (A)
Type MP-GC EPR/CPE 3 × 4 AWG + 2 × 8 AWG G + 1 × 8 AWG GC1151101.541608122
Type MP-GC EPR/CPE 3 × 2 AWG + 2 × 6 AWG G + 1 × 8 AWG GC1151101.661919159
Type MP-GC EPR/CPE 3 × 1 AWG + 2 × 5 AWG G + 1 × 8 AWG GC1151101.782507184
Type MP-GC EPR/CPE 3 × 1/0 AWG + 2 × 4 AWG G + 1 × 8 AWG GC1151101.892660211
Type MP-GC EPR/CPE 3 × 2/0 AWG + 2 × 3 AWG G + 1 × 8 AWG GC1151102.033257243
Type MP-GC EPR/CPE 3 × 4/0 AWG + 2 × 1 AWG G + 1 × 8 AWG GC1151402.284382321
Type MP-GC EPR/CPE 3 × 250 kcmil + 2 × 1/0 AWG G + 1 × 8 AWG GC1151402.314965355
Type MP-GC EPR/CPE 3 × 350 kcmil + 2 × 2/0 AWG G + 1 × 8 AWG GC1151402.586484435
Type MP-GC EPR/CPE 3 × 500 kcmil + 2 × 4/0 AWG G + 1 × 8 AWG GC1151402.888857536
Type MP-GC EPR/CPE 15 kV — 100% insulation level; ampacity at 90°C conductor / 40°C ambient
Model and configuration: power + G + GCEPR insulation (mils)CPE jacket (mils)Nominal OD (in.)Approx. mass (lb/1,000 ft)Ampacity (A)
Type MP-GC EPR/CPE 3 × 2 AWG + 2 × 6 AWG G + 1 × 8 AWG GC1751101.982517164
Type MP-GC EPR/CPE 3 × 1 AWG + 2 × 5 AWG G + 1 × 8 AWG GC1751102.113023187
Type MP-GC EPR/CPE 3 × 1/0 AWG + 2 × 4 AWG G + 1 × 8 AWG GC1751102.183296215
Type MP-GC EPR/CPE 3 × 2/0 AWG + 2 × 3 AWG G + 1 × 8 AWG GC1751102.303679246
Type MP-GC EPR/CPE 3 × 4/0 AWG + 2 × 1 AWG G + 1 × 8 AWG GC1751402.545146325
Type MP-GC EPR/CPE 3 × 250 kcmil + 2 × 1/0 AWG G + 1 × 8 AWG GC1751402.615618359
Type MP-GC EPR/CPE 3 × 350 kcmil + 2 × 2/0 AWG G + 1 × 8 AWG GC1751402.807055438
Type MP-GC EPR/CPE 3 × 500 kcmil + 2 × 4/0 AWG G + 1 × 8 AWG GC1751703.159405536
Type MP-GC EPR/CPE 25 kV — 100% insulation level; ampacity at 90°C conductor / 30°C ambient
Model and configuration: power + G + GCEPR insulation (mm)CPE jacket (mm)Nominal OD (mm)Approx. mass (kg/km)Ampacity (A)
Type MP-GC EPR/CPE 3 × 1 AWG + 2 × 5 AWG G + 1 × 8 AWG GC6.603.661.55302210
Type MP-GC EPR/CPE 3 × 1/0 AWG + 2 × 4 AWG G + 1 × 8 AWG GC6.603.663.75918240
Type MP-GC EPR/CPE 3 × 2/0 AWG + 2 × 3 AWG G + 1 × 8 AWG GC6.604.366.16688274
Type MP-GC EPR/CPE 3 × 3/0 AWG + 2 × 2 AWG G + 1 × 8 AWG GC6.604.368.97704315
Type MP-GC EPR/CPE 3 × 4/0 AWG + 2 × 1 AWG G + 1 × 8 AWG GC6.604.373.58881360
Type MP-GC EPR/CPE 3 × 250 kcmil + 2 × 1/0 AWG G + 1 × 8 AWG GC6.604.376.09814396
Type MP-GC EPR/CPE 3 × 350 kcmil + 2 × 2/0 AWG G + 1 × 8 AWG GC6.604.381.712262482
Type MP-GC EPR/CPE 3 × 500 kcmil + 2 × 3/0 AWG G + 1 × 8 AWG GC6.604.388.815369590
Type MP-GC EPR/CPE 35 kV — 100% insulation level; ampacity at 90°C conductor / 30°C ambient
Model and configuration: power + G + GCEPR insulation (mm)CPE jacket (mm)Nominal OD (mm)Approx. mass (kg/km)Ampacity (A)
Type MP-GC EPR/CPE 3 × 1/0 AWG + 2 × 4 AWG G + 1 × 8 AWG GC8.764.373.47452240
Type MP-GC EPR/CPE 3 × 2/0 AWG + 2 × 3 AWG G + 1 × 8 AWG GC8.764.376.38256274
Type MP-GC EPR/CPE 3 × 3/0 AWG + 2 × 2 AWG G + 1 × 8 AWG GC8.764.378.99223315
Type MP-GC EPR/CPE 3 × 4/0 AWG + 2 × 1 AWG G + 1 × 8 AWG GC8.764.381.910312360
Type MP-GC EPR/CPE 3 × 250 kcmil + 2 × 1/0 AWG G + 1 × 8 AWG GC8.764.384.711289396
Type MP-GC EPR/CPE 3 × 350 kcmil + 2 × 2/0 AWG G + 1 × 8 AWG GC8.765.191.814173482
Type MP-GC EPR/CPE 3 × 500 kcmil + 2 × 3/0 AWG G + 1 × 8 AWG GC8.765.198.917818590
Type MP-GC EPR/PVC 25 kV — 100% insulation level; ampacity at 90°C conductor / 30°C ambient
Model and configuration: power + G + GCEPR insulation (mm)PVC jacket (mm)Nominal OD (mm)Approx. mass (kg/km)Ampacity (A)
Type MP-GC EPR/PVC 3 × 1 AWG + 2 × 5 AWG G + 1 × 8 AWG GC6.603.661.54673210
Type MP-GC EPR/PVC 3 × 1/0 AWG + 2 × 4 AWG G + 1 × 8 AWG GC6.603.663.75256240
Type MP-GC EPR/PVC 3 × 2/0 AWG + 2 × 3 AWG G + 1 × 8 AWG GC6.604.366.16025274
Type MP-GC EPR/PVC 3 × 3/0 AWG + 2 × 2 AWG G + 1 × 8 AWG GC6.604.368.96894315
Type MP-GC EPR/PVC 3 × 4/0 AWG + 2 × 1 AWG G + 1 × 8 AWG GC6.604.373.58026360
Type MP-GC EPR/PVC 3 × 250 kcmil + 2 × 1/0 AWG G + 1 × 8 AWG GC6.604.376.08925396
Type MP-GC EPR/PVC 3 × 350 kcmil + 2 × 2/0 AWG G + 1 × 8 AWG GC6.604.381.711315482
Type MP-GC EPR/PVC 3 × 500 kcmil + 2 × 3/0 AWG G + 1 × 8 AWG GC6.604.388.814055590
Type MP-GC EPR/PVC 35 kV — 100% insulation level; ampacity at 90°C conductor / 30°C ambient
Model and configuration: power + G + GCEPR insulation (mm)PVC jacket (mm)Nominal OD (mm)Approx. mass (kg/km)Ampacity (A)
Type MP-GC EPR/PVC 3 × 1/0 AWG + 2 × 4 AWG G + 1 × 8 AWG GC8.764.373.46486240
Type MP-GC EPR/PVC 3 × 2/0 AWG + 2 × 3 AWG G + 1 × 8 AWG GC8.764.376.37221274
Type MP-GC EPR/PVC 3 × 3/0 AWG + 2 × 2 AWG G + 1 × 8 AWG GC8.764.378.98077315
Type MP-GC EPR/PVC 3 × 4/0 AWG + 2 × 1 AWG G + 1 × 8 AWG GC8.764.381.99196360
Type MP-GC EPR/PVC 3 × 250 kcmil + 2 × 1/0 AWG G + 1 × 8 AWG GC8.764.384.710107396
Type MP-GC EPR/PVC 3 × 350 kcmil + 2 × 2/0 AWG G + 1 × 8 AWG GC8.765.191.812785482
Type MP-GC EPR/PVC 3 × 500 kcmil + 2 × 3/0 AWG G + 1 × 8 AWG GC8.765.198.915976590

G identifies each protective-earth conductor; GC identifies the insulated ground-check conductor. The first three equal conductors are the power cores.

Select dimensions from the table for the ordered voltage and jacket material; dimensions for one voltage class must not be used for another.

The 5, 8 and 15 kV tables retain inch/mil and lb/1,000 ft units. The 25 and 35 kV tables use millimetres and kg/km. One mil is 0.001 inch.

Ampacities use a 90°C conductor temperature: 40°C ambient for the 5–15 kV tables and 30°C ambient for the 25–35 kV tables. Apply the installation, grouping and ambient conditions when calculating the circuit rating.

Dimensions and masses are nominal reference values. Use the quoted configuration and outside-diameter tolerance when selecting glands, supports and terminations.

The EPR/PVC tables are distinct from XLPE/PVC MP-GC constructions. Insulation material, jacket material and voltage must all appear on the order specification.

A vertical installation requires its own support arrangement and allowable-load check; the cable is not specified here for unrestricted unsupported shaft suspension.

Where a different insulation level or a three-earth-conductor arrangement is required, identify it separately in the enquiry; the listed two-earth-plus-ground-check tables do not define those configurations.

Standards

Standards

Type MP-GC EPR/CPE Mine Power Feeder Cable, 5–35 kV standards and test references
Standard or specificationApplication
ICEA S-75-381 / NEMA WC-58Mine power-feeder design reference for the 5–25 kV constructions.
ASTM B8Concentric-lay stranded copper-conductor construction reference.
ASTM B33Tin-coated copper-wire reference for the grounding-conductor construction.
CSA C22.2 No. 96.1Mine power-feeder cable design and test reference; the selected voltage and construction identify the applicable requirements.

Official standards and approval references

The current NEMA/ICEA publication uses NEMA WC 23058 in place of the historical WC 58 designation. The CSA record identifies C22.2 No. 96.1-16 (R2026). Keep the voltage, insulation level and jacket selection tied to the separate configuration tables on this page.

Certifications and document support

Review our company certificates and document scopes when identifying the documentation required for the quoted construction.

For certificate or acceptance-document review, identify the voltage class, insulation level, EPR insulation, CPE or PVC jacket, conductor sizes and ground-check arrangement. A record for one voltage or material system must be matched to its stated scope before it is used for another construction. Include the specified approval body and marking requirements with the order enquiry.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.