ZW-(QG)GNOTKSdD (4–8 Fibres) Non-Metallic LSZH Aramid-Reinforced Underground Mine Fibre Optic Cable

ZW-(QG)GNOTKSdD (also written ZW-QGGNOTKSdD, built to TT1-2078/3/0) is a fully dielectric, non-metallic reinforced mine fibre optic cable in 4, 6 and 8 fibres combining 0.9 mm acryl/polyamide tight-buffered fibres inside aramid-reinforced 0.6 mm LSOH optical modules, 1.0 mm FRP dielectric armouring rods, a 1.0 mm thermoplastic rubber inner sheath, aramid cable reinforcement and a composite 3.0 mm thermoplastic rubber plus 1.5 mm polyurethane outer sheath rated for 6000 N dynamic tension.

Product information
SKU
PL-ZW-QGGNOTKSDD-4-8J
Brand
TEBAOFLEX
Product overview

Automated shearers, roadheaders, shuttle cars and shaft conveyances require an optical data link that combines the high tensile strength of an armoured shaft cable with the repeated-flexing endurance of a reeling cable—without any metallic armour that could conduct fault currents or spark in methane zones. ZW-(QG)GNOTKSdD (4–8 J), built to works specification TT1-2078/3/0, is the heavy-duty fully dielectric mine fibre optic cable designed for that dual role.

Instead of loose tubes, each optical fibre is protected by a 0.9 mm tight buffer (acryl inner layer and polyamide outer layer) and its own aramid-reinforced 0.6 mm LSOH optical module sheath, colour-coded by fibre family: yellow for ITU-T G.652D single-mode, green for ITU-T G.651 (62.5 um), orange for ITU-T G.651 (50 um) and brown for ITU-T G.655. The stranded optical modules are armoured with 1.0 mm fibre-reinforced plastic (FRP) dielectric rods, cushioned by a 1.0 mm thermoplastic rubber (TPR) inner sheath, reinforced with a second aramid yarn layer and finished with a thick two-layer outer jacket consisting of 3.0 mm nominal (2.5 mm min.) thermoplastic rubber under a 1.5 mm nominal (1.2 mm min.) polyurethane skin.

This heavy multi-stage elastomer and FRP-rod construction gives 4- and 6-fibre cables (max. 18.0 mm O.D., 340 kg/km) and 8-fibre cables (max. 19.0 mm O.D., 365 kg/km) a 6000 N dynamic and 4000 N static tensile rating at a compact 140 to 150 mm minimum bending radius (both static and dynamic). Use ZW-(QG)GNOTKSdD on moving machine parts and metal-free vertical/horizontal runs; choose lightweight PSKD for hand-carried tactical reels and YOTKGtsDFoyn for high-count (up to 144F) steel-wire-armoured fixed backbones.

Explore the mining and tunneling cable range for related configurations.

Construction

ZW-(QG)GNOTKSdD (4–8J) Dielectric Mine Fibre Optic Cable Construction

The representative horizontal sample shows ZW-(QG)GNOTKSdD 6J (6 fibres, max. 18.0 mm O.D.): six yellow 0.6 mm LSOH optical modules (each containing a 0.9 mm tight-buffered G.652D fibre and aramid yarn), a ring of 1.0 mm FRP dielectric armouring rods, a 1.0 mm thermoplastic rubber inner sheath, aramid yarn reinforcement and a thick dual-layer thermoplastic rubber (3.0 mm) plus polyurethane (1.5 mm) outer sheath.

Flat 2D cross-section diagram of ZW-(QG)GNOTKSdD mine fibre optic cable showing 0.9 mm tight-buffered fibres in 0.6 mm LSOH modules, 1.0 mm FRP dielectric armour rods, 1.0 mm TPR inner sheath, aramid yarn reinforcement and 3.0 mm TPR plus 1.5 mm polyurethane outer sheath
ZW-(QG)GNOTKSdD cross-section: 0.9 mm tight buffers in LSOH modules, FRP rod armour, TPR bedding and TPR/PU outer jacket.
ZW-(QG)GNOTKSdD (4–8 Fibres) Non-Metallic LSZH Aramid-Reinforced Underground Mine Fibre Optic Cable construction
ComponentMaterial and construction
0.9 mm Tight-Buffered Fibres4, 6 or 8 optical fibres (ITU-T G.652D, G.651 62.5/125, G.651 50/125 or G.655) with 0.9 mm acryl inner / polyamide outer tight buffer, coloured to IEC 60304.
Aramid-Reinforced LSOH Optical ModulesEach tight-buffered fibre is reinforced with dielectric aramid yarn and enclosed in a 0.6 mm LSOH module jacket (yellow G.652D, green G.651 62.5, orange G.651 50, brown G.655).
1.0 mm FRP Dielectric Rod ArmouringNon-metallic armouring of 1.0 mm diameter fibre-reinforced plastic (FRP) dielectric rods resisting crush, stretching and kinking.
TPR Inner Sheath & Aramid Reinforcement1.0 mm thermoplastic rubber (TPR) inner bedding surrounded by a cable-level dielectric aramid yarn tensile layer.
Dual-Layer TPR + Polyurethane Outer SheathHigh-oxygen-index composite outer jacket: 3.0 mm nominal (2.5 mm min.) thermoplastic rubber inner layer bonded under a 1.5 mm nominal (1.2 mm min.) abrasion-resistant polyurethane outer skin.

ZW-(QG)GNOTKSdD Type Designation Breakdown

  • ZW: high-tensile reinforced cable for repeated winding, unwinding and bending
  • (QG): mining (gorniczy) heavy-duty thermoplastic rubber and polyurethane jacket system
  • GN: fully dielectric (non-metallic) mining construction with 1.0 mm FRP armouring rods
  • OTK: optical telecommunication cable
  • Sd: 0.9 mm tight-buffered fibres inside 0.6 mm colour-coded LSOH optical modules
  • D: dielectric aramid yarn reinforcement inside optical modules and over the inner sheath
Applications

ZW-(QG)GNOTKSdD Moving Machine & Underground Mine Applications

Specify ZW-(QG)GNOTKSdD where high tensile load (6000 N), repeated dynamic winding and 100% metal-free safety are simultaneously required.

ZW-(QG)GNOTKSdD flexible non-metallic fibre optic cable routed through a dynamic guide chain on an underground mining machine
ZW-(QG)GNOTKSdD dielectric fibre optic cable flexing on a moving underground mining machine.
  • Moving booms, cable chains, reeling drums and articulated joints on underground mining and tunneling machinery requiring repeated winding, unwinding and bending.
  • Metal-free vertical shaft, incline and horizontal gallery optical links where metallic armour is prohibited due to stray earth currents or explosive-atmosphere bonding rules.
  • Full-bandwidth digital and analogue video, LiDAR and PLC telemetry alongside high-voltage trailing cables with complete immunity to electromagnetic interference.
  • Direct replacement of in-service TT1-2078/3/0 ZW-(QG)GNOTKSdD 4J, 6J and 8J mine optical cables.

ZW-(QG)GNOTKSdD vs PSKD and YOTKGtsDFoyn Selection Boundary

ZW-(QG)GNOTKSdD compared with related mine and dynamic fibre optic cables
ModelCore & module buildArmour & outer jacketBest fit
ZW-(QG)GNOTKSdD (this page)4, 6 or 8F in 0.9 mm buffer + 0.6 mm LSOH modules1.0 mm FRP rods + aramid; 1.0 mm TPR + 3.0 mm TPR + 1.5 mm PU (max. 18-19 mm)Moving parts of mining machines & metal-free vertical/horizontal runs (6000 N)
PSKD2 to 24F, 0.9 mm tight bufferDouble aramid yarns; dual 0.6 mm black PU sheaths (5.8-9.5 mm)Lightweight portable tactical reels and emergency mine links (2500 N)
YOTKGtsDFoyn4 to 144F, 2.4 mm gel-filled loose tubes1.54 mm galvanized steel wires + aramid + blue PVC-FR (17.9-21.9 mm)Fixed steel-wire-armoured vertical shafts and roadways (8000-12000 N)
Flexible Crane Fibre Optic Cable2 to 24F, festoon/reeling constructionPUR or rubber jacket for crane festoons and reelsSurface crane spreaders, festoons and cable chains

Unlike general crane fibre cables, ZW-(QG)GNOTKSdD combines 1.0 mm FRP rod dielectric armouring with a 4.5 mm composite TPR+PU outer sheath specifically for underground mining.

Related selection resources

ZW-(QG)GNOTKSdD (ZW-QGGNOTKSdD) Frequently Asked Questions

How does ZW-(QG)GNOTKSdD achieve 6000 N dynamic tensile strength without steel armour?

ZW-(QG)GNOTKSdD combines three non-metallic reinforcement stages: aramid yarn inside each 0.6 mm LSOH optical module, a ring of 1.0 mm diameter fibre-reinforced plastic (FRP) dielectric armouring rods, and an outer cable-level aramid yarn layer between the 1.0 mm TPR inner sheath and the 3.0 mm TPR + 1.5 mm PU outer sheath.

What do the LSOH optical module sheath colours indicate inside ZW-(QG)GNOTKSdD?

Under TT1-2078/3/0, the 0.6 mm LSOH sheath of each optical module identifies the installed optical fibre grade: yellow for ITU-T G.652D single-mode, green for ITU-T G.651 (62.5/125 um multimode), orange for ITU-T G.651 (50/125 um multimode) and brown for ITU-T G.655 non-zero dispersion-shifted single-mode.

Why is the minimum bending radius identical (140 or 150 mm) for both static and dynamic service?

Because the 1.0 mm FRP dielectric rods and thick composite thermoplastic rubber (1.0 mm inner + 3.0 mm outer inner-layer) plus 1.5 mm polyurethane jacket distribute bending strain uniformly and prevent local kinking, TT1-2078/3/0 specifies a single 140 mm minimum radius for 4J/6J and 150 mm for 8J across both static installation and dynamic reeling/bending.

What should be specified when ordering ZW-(QG)GNOTKSdD?

State the fibre count (4J, 6J or 8J), the optical fibre grade (ITU-T G.652D single-mode, G.651 50/125 or 62.5/125 multimode, or G.655), the operating mode (fixed vertical/horizontal or moving machine reeling/festoon) and the required drum length.

Specifications

ZW-(QG)GNOTKSdD Dimensions, Module Coding & Technical Specifications

ZW-(QG)GNOTKSdD Key Specifications

  • Fibre counts: 4J (4 fibres), 6J (6 fibres) and 8J (8 fibres), max. O.D. 18.0 mm (4/6F) and 19.0 mm (8F)
  • Optical modules: 0.9 mm acryl/polyamide tight buffer + aramid yarn + 0.6 mm colour-coded LSOH module sheath
  • Dielectric armour: 1.0 mm FRP dielectric rods + aramid yarn layers (100% metal-free, 6000 N dynamic / 4000 N static)
  • Heavy sheath system: 1.0 mm TPR inner sheath + dual outer sheath (3.0 mm nom. TPR inner + 1.5 mm nom. PU outer)
  • Duty scope: Horizontal, vertical shaft and moving mining machine parts with repeated winding and bending
ZW-(QG)GNOTKSdD (4–8 Fibres) Non-Metallic LSZH Aramid-Reinforced Underground Mine Fibre Optic Cable technical data
ParameterValue
Construction referenceTT1-2078/3/0
Fibre counts & module coding4, 6 or 8 fibres in 0.6 mm LSOH modules (yellow G.652D, green G.651 62.5, orange G.651 50, brown G.655)
Dielectric armour & sheaths1.0 mm FRP rods + aramid yarns; 1.0 mm TPR inner sheath; 3.0 mm TPR + 1.5 mm PU dual outer sheath
Tensile load & weight6000 N dynamic (installation) / 4000 N static (operation); 340 kg/km (4/6F) to 365 kg/km (8F)
Temperatures & bending radiusInstallation -5 °C to +60 °C; operating -20 °C to +60 °C; min. static and dynamic bending radius 140 mm (4/6F) and 150 mm (8F)
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7 to 45 working days; final values confirmed on the quotation drawing
Selection boundary vs PSKD, YOTKGtsDFoyn and Crane Fibre CableChoose ZW-(QG)GNOTKSdD for heavy-wall (18-19 mm, 6000 N) FRP-rod reinforced dynamic mine machine and vertical/horizontal duty; choose PSKD for lightweight 5.8-9.5 mm portable reels and YOTKGtsDFoyn for 4-144F steel-wire-armoured fixed shafts.

ZW-(QG)GNOTKSdD (TT1-2078/3/0) 4J, 6J & 8J Reference Schedule

ZW-(QG)GNOTKSdD (TT1-2078/3/0) Non-Metallic Reinforced Mine Fibre Optic Cable — Reference Schedule
Cable DesignationTight Buffer Diameter (mm)Elements in CableMax. Outer Diameter (mm)Approx. Weight (kg/km)Max. Dynamic Tensile Load (N)Max. Static Tensile Load (N)Min. Static & Dynamic Bend Radius (mm)Next step
ZW-(QG)GNOTKSdD 4J (4 fibres)0.9418.034060004000140Request this size
ZW-(QG)GNOTKSdD 6J (6 fibres)0.9618.034060004000140Request this size
ZW-(QG)GNOTKSdD 8J (8 fibres)0.9819.036560004000150Request this size

ZW-(QG)GNOTKSdD Layer Architecture & Module Colour Coding

ZW-(QG)GNOTKSdD — Layer Architecture, Module Coding & Rating Parameters
ParameterSpecification (TT1-2078/3/0)
Works construction referenceTT1-2078/3/0
Optical fibres & colours4, 6 or 8 fibres to ITU-T G.652D, G.651 (62.5 or 50 um) or G.655; IEC 60304 colours (red, green, blue, white, violet, orange, grey, yellow)
Secondary coating (tight buffer)0.9 mm diameter: acryl inner layer and polyamide outer layer
Optical module reinforcement & sheathDielectric aramid yarn under a 0.6 mm LSOH module sheath (yellow for G.652D, green for G.651 62.5, orange for G.651 50, brown for G.655)
Dielectric armouringFibre-reinforced plastic (FRP) dielectric rods, 1.0 mm diameter
Inner sheath & cable reinforcementThermoplastic rubber inner sheath (1.0 mm thickness) + dielectric aramid yarn reinforcement
Two-layer outer sheathInner layer: thermoplastic rubber (min. 2.5 mm, nominal 3.0 mm); outer layer: polyurethane (min. 1.2 mm, nominal 1.5 mm)
Max. attenuation (SMF G.652D)0.5 dB/km at 1310 nm; 0.35 dB/km at 1550 nm
TemperaturesInstallation -5 °C to +60 °C; operating -20 °C to +60 °C
Permitted installationHorizontal, vertical and on moving parts of mining machines requiring repeated winding, unwinding and bending

The TT1-2078/3/0 dimensional table groups 4 and 6 fibres on one row (0.9 mm buffer, 4 or 6 elements, max. O.D. 18.0 mm, 340 kg/km, 6000 N / 4000 N, 140 mm bending radius) and lists 8 fibres on the second row (max. O.D. 19.0 mm, 365 kg/km, 150 mm bending radius); all three discrete order sizes (4J, 6J and 8J) are listed above for direct BOM selection.

Polish and Central European designations and the TT1 / ZN works specifications are cited as construction references; TEBAOFLEX builds to the referenced construction and does not claim a Polish mining admission or third-party approval for it, so state the approval documents your mine requires when requesting a quotation.

ASCII part references for BOM and ERP entry: ZW-GNOTKSdD 4J, ZW-GNOTKSdD 6J, ZW-GNOTKSdD 8J.

Standards

ZW-(QG)GNOTKSdD Standards & Test References (TT1-2078/3/0)

ZW-(QG)GNOTKSdD (4–8 Fibres) Non-Metallic LSZH Aramid-Reinforced Underground Mine Fibre Optic Cable standards and test references
Standard or specificationApplication
TT1-2078/3/0Works construction specification for ZW-(QG)GNOTKSdD 4 to 8 fibre dielectric reinforced mine fibre optic cable.
ITU-T G.652D / G.651 / G.655International optical fibre standards supported by the colour-coded 0.6 mm LSOH optical modules.
IEC 60304Standard colour identification code for optical fibres (red, green, blue, white, violet, orange, grey, yellow).
IEC 60794Generic specification family for optical fibre cables and mechanical/environmental test procedures.

Certifications and document support

TEBAOFLEX company certificates and quality system documentation

IEC Webstore — IEC 60304 colour code and IEC 60794 optical fibre cable publications (international references)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.