FD 300/500 V PUR Servo Control Cable
FD 300/500 V PUR servo cable family covering FD05855 P, FD30810 CP and FD95810 P. Select by exact model, screen, insulation, sheath and movement duty.
FD 300/500 V PUR Servo Cable Family
The FD 300/500 V family groups flexible P and CP constructions for power chains, moving machine parts, measuring, control and automation circuits. FD05855 P is unscreened with TPE core insulation and a PUR sheath. FD30810 CP is screened, with PVC TI2 core insulation, a PVC inner sheath and a tinned-copper braid beneath a PUR outer sheath. FD95810 P is also unscreened and uses special PVC TI2 insulation, non-woven wrapping and a gray PUR sheath.
The shared purchasing intent is the FD 300/500 V servo and control cable family; the model rows are deliberately separate because their screens, materials, temperature ranges and bend radii differ. Use the exact marking, size table and movement conditions for the selected cable rather than choosing from the family name alone.
- Choose P or CP: screened FD30810 CP serves a different EMC and grounding decision from the unscreened P models.
- Compare the sheath: FD05855 P, FD95810 P and FD30810 CP do not share one layer sequence.
- Provide for RFQ: model marking, core schedule, size, route, bend duty, length and required documents.
For higher-voltage options, compare the FD 600/1000 V shielded servo cable family.
Construction
The FD family contains distinct 300/500 V constructions. The model table keeps screening and layer sequence separate so a P model is not presented as a CP model.
| Model | Screening | Layer and material description |
|---|---|---|
| FD05855 P | Unscreened | TPE core insulation, non-woven layer and PUR sheath |
| FD30810 CP | Screened | PVC TI2 core insulation, PVC inner sheath, tinned-copper braid and PUR outer sheath |
| FD95810 P | Unscreened | Special PVC TI2 core insulation, non-woven wrapping and gray PUR outer sheath, RAL 7001 |
Applications
- Power chains and moving machine parts where the selected 300/500 V construction matches the route.
- Measuring, control and regulating circuits.
- Automation equipment and OEM replacement enquiries using an existing FD marking.
Specify the model, installation movement, bend radius, temperature, cable length, control-core function and EMC requirement. For higher-voltage screened options, review the separate FD 600/1000 V family.
Specifications
| Model | Voltage | Screen | Temperature | Minimum bend radius |
|---|---|---|---|---|
| FD05855 P | U0/U 300/500 V | Unscreened | Flexible -40 to +70 deg C; fixed -50 to +70 deg C | 5 x D flexible; 3 x D fixed |
| FD30810 CP | U0/U 300/500 V | Screened | Flexible -5 to +70 deg C; fixed -30 to +70 deg C | 7.5 x D flexible; 4 x D fixed |
| FD95810 P | U0/U 300/500 V | Unscreened | Flexible -5 to +70 deg C; fixed -30 to +70 deg C | 7.5 x D flexible; 4 x D fixed |
| Test references | FD05855 P: 4000 V; FD30810 CP: supply C/C 4000 V and C/S 2000 V; FD95810 P: 4000 V | |||
| Insulation resistance, dimensions, weight and conductor size | Minimum insulation resistance is 20 GOhm x cm; use the selected model table for ordering | |||
Standards
- FD05855 P: adapted DIN VDE 0250/0281/0282, EN 60228 class 6, DIN VDE 0293 and EN 60332-1-2 references.
- FD30810 CP: adapted DIN VDE 0245/0281, PVC TI2 EN 50363-3 and EN 60332-1-2 references.
- FD95810 P: adapted DIN VDE 0245/0281, EN 60228 class 6, PVC TI2 EN 50363-3 and EN 60332-1-2 references; ASTM G154 UV reference.
The quotation record identifies the selected model, size and applicable inspection documentation.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Festoonflex PUR-HF Cable 0.6/1 kV for Cranes and Moving Equipment
A related cable option for a different application or duty profile.
View productGPM / GPM-RF PUR Reeling Cable 0.6/1 kV
A related cable option for a different application or duty profile.
View productRP / RP-D Compact PUR Reeling Cable 0.6/1 kV
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.