NTSCGERLWOEU 3.6/6 kV Flexible Submersible Cable
NTSCGERLWOEU cable is a 3.6/6 kV flexible submersible cable for permanent water operation where additional mechanical protection is required. The supplied 3 × 120 + 3 × 70/3E configuration combines class 5 flexible copper conductors, 3GI3 rubber insulation, a galvanised steel-strand braid and a 5GM5 rubber outer sheath.
- Voltage: 3.6/6 kV
- Reference configuration: 3 × 120 + 3 × 70/3E mm²
- Conductor: flexible stranded copper, class 5
- Mechanical protection: galvanised steel-strand braid
- Inner sheath: waterproof synthetic butyl rubber
- Outer sheath: 5GM5 rubber; red shown in the supplied cross-section
- Standard reference: VDE 0250 Part 813
Send the cable marking, route, quantity, water-duty conditions, termination details and documentation requirements for a technical quotation.
NTSCGERLWOEU 3.6/6 kV flexible submersible cable
TEBAOFLEX NTSCGERLWOEU cable is a flexible medium-voltage power cable for permanent operation in water where the route also requires added mechanical protection. The supplied 3 × 120 + 3 × 70/3E reference configuration has a galvanised steel-strand braid and rubber sheathing, helping procurement teams identify it as a protected water-duty construction rather than an ordinary flexible power cable.
This page is deliberately specific to the supplied 3.6/6 kV configuration. It records the available diameter range and approximate weight, while leaving unsupplied project limits—such as water depth, bending radius, current capacity and tensile load—to the approved cable drawing. That distinction matters: a cable can look suitably armoured on a reel yet still be wrong for the route, termination or earth-core arrangement.
- Suitable for: permanent water-operation duties requiring a flexible, mechanically protected medium-voltage cable.
- Reference size: 3 × 120 + 3 × 70/3E mm², with a 75–80 mm overall-diameter range.
- Confirm before ordering: installation route, water conditions, cable support, earth and pilot-core requirement, length and test documents.
- Choose another construction when: the project needs a proven depth rating, a stated movement/reeling rating or electrical values not supplied for this configuration.
Explore the submersible pump cable range for other water-duty power-cable options. The technical details for this model are in the Construction, Applications, Specifications and Standards tabs.
NTSCGERLWOEU cable construction
The supplied NTSCGERLWOEU construction uses flexible class 5 stranded copper conductors, conductive rubber layers around 3GI3 rubber insulation, and a galvanised steel-strand braid. This layer sequence combines electrical field-control materials with added mechanical protection for the stated water-operation duty.

| Construction element | Supplied material or arrangement |
|---|---|
| Phase conductors | Flexible stranded copper, class 5 according to DIN VDE 0295 |
| Inner conductor layer | Special conductive rubber compound |
| Insulation | Rubber type 3GI3 |
| Outer conductor layer | Special conductive rubber, easy strippable |
| Pilot cores | Optional copper conductor with EPR insulation |
| Earth conductor | Spiral of tinned annealed copper wires |
| Inner sheath | Waterproof synthetic butyl rubber |
| Armouring | Braid of galvanised steel strands |
| Outer sheath | Rubber type 5GM5; red on the supplied cross-section image |
Applications
NTSCGERLWOEU is specified for permanent operation in water where the cable also needs additional mechanical protection. The supplied construction is relevant to submerged fixed-service power connections for equipment such as pumps, dredging equipment and similar water-duty installations where the final project design calls for a braided flexible medium-voltage cable.
Selection checks before ordering
- Confirm the required voltage, route length, termination system and whether optional pilot cores are needed.
- Confirm the 3 × 120 + 3 × 70/3E conductor arrangement against the connected equipment and earthing design.
- Define the installation path, support points and strain-relief arrangement; the steel braid provides mechanical protection but does not replace project-specific suspension or termination design.
- State water conditions, immersion depth, movement and any inspection or test-document requirement. These limits are not supplied for this specific configuration and must be reviewed for the quotation.
TEBAOFLEX can review the existing cable marking, conductor arrangement and installation duty before issuing a technical quotation, helping the buyer avoid ordering a similar-looking construction with a different earth or pilot-core layout.
Specifications
The following values are the supplied reference data for the NTSCGERLWOEU 3.6/6 kV configuration. Confirm the final cable drawing and dimensions before release to production.
| Model | NTSCGERLWOEU |
|---|---|
| Rated voltage | 3.6/6 kV |
| Reference core configuration | 3 × 120 + 3 × 70/3E mm² |
| Minimum overall diameter | 75 mm |
| Maximum overall diameter | 80 mm |
| Approximate weight | 9,980 kg/km |
| Installation duty stated in supplied material | Permanent operation in water with additional mechanical protection |
Ordering boundary
Only the 3 × 120 + 3 × 70/3E reference size, diameter range and approximate weight were supplied. Temperature limits, bending radius, tensile load, water depth, current capacity, resistance, test voltage and reeling speed were not supplied for this configuration, so they are not stated as product claims.
Standards
The supplied technical information identifies the following standard references for NTSCGERLWOEU. Include the required standard edition and any project-specific inspection or test documentation in the RFQ.
| Cable standard reference | VDE 0250 Part 813 |
|---|---|
| Conductor class reference | DIN VDE 0295, class 5 |
Confirm the required edition, final documentation and test requirements for the ordered cable configuration in the RFQ.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
3.6/6kV to 18/30kV NTSCGEWOEU-W Cable
A related cable option for a different application or duty profile.
View product(N)TSCGECEWÖU Submersible Cable 3.6/20kV | 300m Mining Pump Cable
A related cable option for a different application or duty profile.
View productSubmersible Pump Motor Cable 450/750V 0.6/1kV with Control Cores
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.