Get a Quote
Port & Festoon Cables TEBAOFLEX

(N)TSCGEW11Y 6/10 kV Shore Power Reeling Cable

(N)TSCGEW11Y is a 6/10 kV halogen-free shore-power reeling cable with power, pilot and optical-fibre elements.

Product information
Brand
TEBAOFLEX
Product overview

(N)TSCGEW11Y 6/10 kV shore power reeling cable

TEBAOFLEX (N)TSCGEW11Y is a halogen-free high-voltage shore-power reeling cable for connecting a vessel to the main grid when berthed at a harbour quay. The supplied application covers high-voltage shore connection (HVSC) systems for ships at berth, including container vessels, and cable-crane or mobile-carrier systems for cruise-liner operation.

The supplied design combines three EPR-insulated main power cores, a ground conductor, screened pilot cores and a 12-fibre multimode optical-fibre element around a central support element. A double-layer thermoplastic inner sheath and TPU outer sheath support the stated reeling duty. Confirm voltage system, crane/reeling geometry, termination, tensile loading, vessel interface, fibre requirement and site approval before final selection.

  • Rated voltage: 6/10 kV.
  • Ambient temperature: fixed −40°C to +90°C; reeling −30°C to +90°C.
  • Maximum conductor temperature: +90°C; short-circuit conductor temperature +200°C.
  • Bending radius: fixed 6× cable diameter; free movement 10×; reeling 12×.

Send the required (N)TSCGEW11Y configuration, shore-power interface, length and documentation requirement for a technical quotation.

Construction

Construction

Main coresFinely stranded tinned copper, IEC 60228 Class 5; triple extruded insulation with inner semi-conductive stress-control layer, EPR insulation and outer semi-conductive layer
Ground conductorFinely stranded tinned copper, IEC 60228 Class 5, semi-conductive layer
Pilot coresFinely stranded tinned copper, IEC 60228 Class 5; twisted around filler, screened EPR compound, white cores with black numerals 1–8
Optical fibre12 fibres in G62.5/125 multimode arrangement
Core arrangementMain cores around central support element with ground conductor and screened pilot/optical-fibre cores in interstices
Double-layer sheathThermoplastic inner sheath and thermoplastic polyurethane TPU outer sheath to EN 50363-10-2; black or other requested colour
(N)TSCGEW11Y 6/10 kV shore power reeling cable construction
(N)TSCGEW11Y cable construction.
(N)TSCGEW11Y power, ground, pilot and fibre conductor arrangement
(N)TSCGEW11Y conductor arrangement.
Applications

Applications

(N)TSCGEW11Y is supplied for vessel-to-grid connection at harbour quays in high-voltage shore connection systems. The stated applications include ships at berth, container-vessel on-board systems and single-operator cable-crane or mobile-carrier systems for cruise liners.

Use the application-specific reeling and tensile-load data only after confirming the actual crane, cable route and shore-power system design.

(N)TSCGEW11Y shore power cable connecting vessel and grid at harbour quay
High-voltage shore-power connection application.
Specifications

Specifications

ConfigurationOuter diameter min.–max.Approx. weight
3×70 + 2×35/2 + 1×(8×2.5)C + FO66–69 mm6,505 kg/km
3×95 + 2×50/2 + 1×(8×2.5)C + FO68–71 mm7,440 kg/km
3×120 + 2×70/2 + 1×(8×2.5)C + FO71–74 mm8,465 kg/km
3×185 + 2×95/2 + 1×(8×2.5)C + FO74–77 mm10,000 kg/km
AC test voltage21 kV
Maximum permissible AC voltage6.9/12 kV
Maximum permissible DC voltage9/18 kV
Optical-fibre attenuationMaximum 3.5 dB/km at 850 nm; 1.5 dB/km at 1300 nm
Standards

Standards

Shore-power referenceIEC/ISO/IEEE 80005-1
Current-carrying-capacity referenceDIN VDE 0298-4
Oil resistanceDIN EN / IEC 60811-404
Fire behaviourDIN EN / IEC 60332-1-2
Fibre standardITU-T G.651; colour code according to ANSI/TIA/EIA 598-A
Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    Optional: attach a cable specification, drawing, data sheet or product image (PDF, DOC, DOCX, XLS, XLSX, CSV, JPG or PNG; maximum 10 MB).

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.