PFA Hook-Up Wire — UL 1726, UL 1727 & UL 10362 Extruded Wire (250 °C, 300/600 V)
PFA single-core high-temperature hook-up wires engineered to UL 1726 (300 V, 13 mil), UL 1727 (600 V, 20 mil), UL 10362 (600 V, 10–12 mil thin-wall) and UL 1709 / UL 1710 specifications (TF-UL-PFA-1726-1727) deliver PTFE-equivalent -80 °C to +250 °C (+260 °C peak) thermal and chemical immunity in 100 % continuous, splice-free melt-extruded lengths (30 AWG to 2 AWG, 305 m / 500 m spools; third-party UL mark not claimed).
PFA single-core equipment wires engineered to UL 758 AWM Styles 1726, 1727, 10362, 1709 and 1710 combine +250 °C continuous service (+260 °C peak) and universal chemical inertness with continuous melt-extrusion consistency, spanning 0.91 mm miniature 30 AWG sensor leads up to 10.3 mm 2 AWG (33.6 mm²) heavy furnace and rectifier feeders.
Conventional paste-extruded PTFE hook-up wires (UL 1180 / UL 1199) are ram-extruded from finite preformed billets, limiting continuous single-piece lengths on larger gauges and leaving microporous grain boundaries under pressurized acid vapour. Perfluoroalkoxy (PFA) incorporates perfluoroalkyl vinyl ether side chains that allow true high-temperature melt extrusion into pinhole-free, mirror-smooth walls with 2x higher flex-fatigue life and superior acid-vapour permeation resistance at +250 °C.
Specify thick-wall UL 1727 (600 V, 0.51–0.76 mm wall) for heavy industrial cabinets and power leads, thin-wall UL 10362 (600 V, 0.25–0.33 mm wall) for compact automated wire looms, or 300 V UL 1726 for instrumentation racks, routine 6,000 V spark-tested on continuous splice-free spools with full conductor resistance verification (third-party UL/CSA mark not claimed; MOQ 305 m / 500 m spools, 7 to 45 working days).
Explore the high-temperature wire and cable range for related configurations.
PFA UL 1726, UL 1727 & UL 10362 Wire Construction
Extruded on corrosion-proof hastelloy/nickel-alloy high-temperature melt lines with laser concentricity control and 100 % inline AC spark testing.

| Component | Material and construction |
|---|---|
| 1. Plated Stranded Copper Conductor (30 AWG to 2 AWG) | Concentric or unidirectional stranded nickel-plated copper (ASTM B355, rated +250/+260 °C continuous) or silver-plated copper (ASTM B298, rated +200 °C); tinned copper available on +150 °C UL 1709/1710. |
| 2. Melt-Extruded Virgin PFA Fluoropolymer Wall | Translucent or solid-pigmented high-purity perfluoroalkoxy wall: 0.25–0.33 mm on UL 10362 / UL 1726, or 0.51–0.76 mm heavy wall on UL 1727. |
| 3. Colour Coding & Optional Helical Stripes | Natural translucent amber-clear (for ultra-high-purity cleanroom/chemical inspection) or 10 solid colours (black, white, red, blue, yellow, green, brown, orange, violet, grey). |
UL 1726, UL 1727 & UL 10362 Style Breakdown
- UL 1727: 600 V AC, +250 °C standard thick-wall (0.51–0.76 mm / 20–30 mil) extruded PFA wire
- UL 10362: 600 V AC, +250 °C thin-wall (0.25–0.33 mm / 10–13 mil) space-saving extruded PFA wire
- UL 1726: 300 V AC, +250 °C medium-wall (0.33 mm / 13 mil) extruded PFA appliance wire
- NPC (ASTM B355): Nickel-plated annealed copper conductor required for continuous +250/+260 °C duty
- SPC (ASTM B298): Silver-plated copper conductor option for +200 °C low-resistance solderable harnesses
PFA Semiconductor Wet-Bench, Downhole & Oven Duty
Chosen whenever an application requires +250 °C thermal endurance PLUS continuous splice-free spool lengths or pressurized wet-chemical permeation immunity.

- Semiconductor wet-bench acid/solvent distribution cabinets, quartz heater leads, CVD/ALD gas-box harnesses and ultra-pure DI water heaters.
- Downhole oil/gas logging tools, submersible chemical-injection pump leads and high-pressure autoclave feedthrough wiring.
- Industrial UV curing lamps, commercial pizza/convection deck ovens, glass tempering equipment and plastics hot-runner heater zones.
- Cryogenic liquid-nitrogen (-196 °C static) and pharma lyophilizer sensor/valve harnesses requiring zero plasticiser extractables.
PFA (UL 1727 / 10362) vs PTFE vs FEP vs ETFE
| Fluoropolymer Wire | Continuous Temp. | Extrusion & Length Capability | Best Engineering Fit |
|---|---|---|---|
| PFA — UL 1726 / 1727 / 10362 (this page) | -80 °C to +250 °C | Melt-extruded 100 % splice-free continuous spools | 250 °C wet acid benches, long automated looms & heavy 8–2 AWG leads |
| PTFE — UL 1180 / 1199 / 1213 | -190 °C to +200/+260 °C | Paste-extruded sintered billets (solder-iron proof) | Hand-soldered electronics, UHV vacuum & cryogenic leads |
| FEP — UL 1330 / 1332 | -70 °C to +200 °C | Melt-extruded continuous spools (most economical) | General +200 °C ovens, appliances & sensor harnesses |
| ETFE — UL 10086 / 1516 | -70 °C to +150/+200 °C | Melt-extruded high-stiffness engineering wall | High-abrasion robotics, stator windings & radiation zones |
Whenever automated Komax/Schleuniger cut-strip lines require zero billet splices at +250 °C, UL 10362 or UL 1727 PFA outperforms paste-extruded PTFE.
PFA Hook-Up Wire (UL 1726 / 1727 / 10362) RFQ Checklist
- Target UL style reference: UL 1727 (600 V 20 mil), UL 10362 (600 V 10 mil thin-wall) or UL 1726 (300 V 13 mil).
- AWG size (30 AWG to 2 AWG) and stranding (solid, 7-strand, 19-strand, 37-strand or 133/665-strand).
- Conductor plating: nickel-plated copper (NPC, +250 °C) or silver-plated copper (SPC, +200 °C).
- Insulation colour (natural translucent or solid colour) and spool quantity (MOQ 305 m / 1,000 ft or 500 m, 7 to 45 working days).
Related selection resources
- Browse all High-Temperature Fluoropolymer, Silicone & Mica Wires
- Compare 200 °C UL 1330, UL 1331, UL 1332 & UL 1333 FEP Hook-Up Wire
- Compare Sintered UL 1180, UL 1199, UL 1213 & UL 1815 PTFE Wire
- Compare Abrasion-Resistant UL 10086 & UL 1516 Extruded ETFE Wire
- Engineering guide: PFA vs PTFE vs FEP vs Silicone insulation limits
PFA Hook-Up Wire Frequently Asked Questions
What is the difference between UL 1727, UL 10362 and UL 1726 PFA hook-up wire?
Wall thickness and voltage rating: UL 1727 uses a 20 mil (0.51 mm) heavy wall for 600 V rugged cabinet power, UL 10362 achieves the same 600 V and +250 °C rating in a compact 10–12 mil (0.25–0.30 mm) thin wall, and UL 1726 uses a 13 mil (0.33 mm) wall for 300 V internal harnesses.
Why specify PFA hook-up wire instead of PTFE hook-up wire when both handle +250 °C?
2 process advantages: melt-extruded PFA is delivered on 100 % splice-free continuous 305 m / 500 m spools (including heavy 8–2 AWG power sizes that PTFE paste extruders cannot run), and dense melt-formed PFA blocks hot acid-vapour permeation better than sintered PTFE.
Can PFA UL 1727 and UL 10362 wire withstand direct soldering-iron contact like PTFE?
No — unlike non-melting sintered PTFE (+327 °C gel point), thermoplastic PFA melts around +305 °C to +310 °C, so use controlled-temperature soldering irons or crimp terminals to avoid insulation nicking.
Do TEBAOFLEX UL 1726, UL 1727 and UL 10362 PFA wires carry a third-party UL Recognition mark?
No — TEBAOFLEX manufactures these PFA wires engineered to UL 758 Style 1726, 1727 and 10362 dimensional, spark-test and +250 °C aging specifications (third-party UL/CSA mark is not claimed).
What is the minimum order quantity and delivery lead time for PFA hook-up wire?
305 m (1,000 ft) or 500 m continuous spools per colour and gauge, manufactured and spark-tested in 7 to 45 working days.
UL 1727 (600 V Thick) & UL 10362 / UL 1726 Schedules
PFA Voltage, Plating, Chemical Permeation & Spool Summary
- Splice-free 250 °C perfluoropolymer: Melt-extrudable perfluoroalkoxy (PFA) matches PTFE's +250/+260 °C rating and 2.1 dielectric constant while eliminating billet paste-extrusion joints
- Complete 300 V & 600 V style coverage: Covers UL 1727 (600 V standard 0.51 mm wall), UL 10362 (600 V space-saving 0.25–0.30 mm thin wall) and UL 1726 (300 V 0.33 mm wall)
- NPC (+250 °C) & SPC (+200 °C) copper: Stranded 7-, 19-, 37-, 133- or 665-wire nickel-plated copper (ASTM B355, +250 °C) or silver-plated copper (ASTM B298, +200 °C) from 30 AWG to 2 AWG
- Ultra-pure wet-chemical barrier: Near-zero extractables and < 0.01 % moisture absorption survive hot HF/HNO3 semiconductor etchants, sour downhole fluids and steam
- Standard 305 m / 500 m spools: Supplied on continuous spark-tested 305 m (1,000 ft) or 500 m factory spools per colour in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | 600 V AC on Styles 1727 and 10362 (2500 V AC dielectric test, 6000 V spark test) and 300 V AC on Style 1726 (2000 V AC dielectric test) |
| Conductor and gauge range | 30 AWG to 2 AWG (0.05 mm2 to 33.6 mm2) in stranded (7, 19, 37, 133 or 665 wires) or solid nickel-plated or silver-plated copper |
| Fluoropolymer insulation system | 100% virgin melt-extruded perfluoroalkoxy (PFA) with 2.1 dielectric constant, under 0.01% water absorption and UL VW-1 / FT1 flame resistance |
| Operating temperature and bend radius | -80 C (-190 C static) to +250 C continuous (+260 C short-term) with nickel-plated copper; 5x OD minimum fixed bend radius |
| Standard put-up and lead time | 305 m (1000 ft) or 500 m continuous splice-free factory spools per colour (MOQ 305 m) in 7 to 45 working days |
| Standards compliance note | Engineered and manufactured to UL 758 AWM Styles 1726, 1727, 10362, 1709 and 1710 dimensional and electrical criteria (third-party UL/CSA mark is not claimed) |
| Chemical and permeation resistance | Lower gas/vapour permeability than sintered PTFE; completely inert to fuming acids, strong bases, halogens, ketones and synthetic oils |
UL 1727 (600 V Thick-Wall, 250 °C) Extruded PFA Wire Schedule
| Style & AWG Gauge | Stranding (Wires/AWG) | Conductor Ø (mm) | Nom. PFA Wall (mm / mil) | Nom. OD (mm / in) | Max. R at 20 °C (Ω/km NPC) | Approx. Weight (kg/km) | Standard Spool MOQ | Next step |
|---|---|---|---|---|---|---|---|---|
| UL 1727 26 AWG (NPC) | 19/38 | 0.48 | 0.51 / 20 | 1.50 / 0.059 | 140.0 | 5.2 | 305 m / 500 m | Request this size |
| UL 1727 24 AWG (NPC) | 19/36 | 0.61 | 0.51 / 20 | 1.63 / 0.064 | 88.9 | 6.5 | 305 m / 500 m | Request this size |
| UL 1727 22 AWG (NPC) | 19/34 | 0.75 | 0.51 / 20 | 1.85 / 0.073 | 51.5 | 8.5 | 305 m / 500 m | Request this size |
| UL 1727 20 AWG (NPC) | 19/32 | 0.96 | 0.51 / 20 | 2.06 / 0.081 | 31.8 | 11.4 | 305 m / 500 m | Request this size |
| UL 1727 18 AWG (NPC) | 19/30 | 1.19 | 0.51 / 20 | 2.31 / 0.091 | 20.0 | 15.6 | 305 m / 500 m | Request this size |
| UL 1727 16 AWG (NPC) | 19/29 | 1.35 | 0.51 / 20 | 2.46 / 0.097 | 15.6 | 19.2 | 305 m / 500 m | Request this size |
| UL 1727 14 AWG (NPC) | 19/27 | 1.69 | 0.51 / 20 | 2.82 / 0.111 | 9.84 | 26.6 | 305 m spool | Request this size |
| UL 1727 12 AWG (NPC) | 19/25 | 2.13 | 0.51 / 20 | 3.35 / 0.132 | 6.20 | 39.3 | 305 m spool | Request this size |
| UL 1727 10 AWG (NPC) | 37/26 | 2.74 | 0.51 / 20 | 3.96 / 0.156 | 4.03 | 57.9 | 305 m spool | Request this size |
| UL 1727 8 AWG (NPC) | 133/29 | 4.14 | 0.76 / 30 | 5.84 / 0.230 | 2.28 | 108.0 | 305 m spool | Request this size |
| UL 1727 6 AWG (NPC) | 133/27 | 5.18 | 0.76 / 30 | 6.91 / 0.272 | 1.43 | 161.0 | 305 m spool | Request this size |
| UL 1727 4 AWG (NPC) | 133/25 | 6.50 | 0.76 / 30 | 8.31 / 0.327 | 0.90 | 246.0 | 305 m spool | Request this size |
| UL 1727 2 AWG (NPC) | 665/30 | 8.38 | 0.76 / 30 | 10.31 / 0.406 | 0.56 | 385.0 | 305 m spool | Request this size |
UL 10362 (600 V Thin-Wall) & UL 1726 (300 V) PFA Wire Schedule
| Style & AWG Gauge | Voltage / Temp. | Stranding (Wires/AWG) | Nom. PFA Wall (mm / mil) | Nom. OD (mm / in) | Approx. Weight (kg/km) | Standard Spool MOQ | Next step |
|---|---|---|---|---|---|---|---|
| UL 10362 28 AWG (NPC) | 600 V / 250 °C | 7/36 | 0.25 / 10 | 0.89 / 0.035 | 2.1 | 305 m / 500 m | Request this size |
| UL 10362 26 AWG (NPC) | 600 V / 250 °C | 19/38 | 0.25 / 10 | 0.99 / 0.039 | 2.8 | 305 m / 500 m | Request this size |
| UL 10362 24 AWG (NPC) | 600 V / 250 °C | 19/36 | 0.25 / 10 | 1.12 / 0.044 | 3.9 | 305 m / 500 m | Request this size |
| UL 10362 22 AWG (NPC) | 600 V / 250 °C | 19/34 | 0.25 / 10 | 1.27 / 0.050 | 5.5 | 305 m / 500 m | Request this size |
| UL 10362 20 AWG (NPC) | 600 V / 250 °C | 19/32 | 0.25 / 10 | 1.47 / 0.058 | 8.2 | 305 m / 500 m | Request this size |
| UL 10362 18 AWG (NPC) | 600 V / 250 °C | 19/30 | 0.25 / 10 | 1.73 / 0.068 | 12.1 | 305 m / 500 m | Request this size |
| UL 10362 16 AWG (NPC) | 600 V / 250 °C | 19/29 | 0.30 / 12 | 2.03 / 0.080 | 16.8 | 305 m / 500 m | Request this size |
| UL 10362 14 AWG (NPC) | 600 V / 250 °C | 19/27 | 0.33 / 13 | 2.41 / 0.095 | 25.4 | 305 m spool | Request this size |
| UL 1726 24 AWG (NPC) | 300 V / 250 °C | 19/36 | 0.33 / 13 | 1.27 / 0.050 | 4.5 | 305 m / 500 m | Request this size |
| UL 1726 20 AWG (NPC) | 300 V / 250 °C | 19/32 | 0.33 / 13 | 1.63 / 0.064 | 9.1 | 305 m / 500 m | Request this size |
| UL 1726 16 AWG (NPC) | 300 V / 250 °C | 19/29 | 0.33 / 13 | 2.06 / 0.081 | 17.0 | 305 m / 500 m | Request this size |
ASCII part references for BOM entry: TF-UL1727-24-NPC, TF-UL1727-20-NPC, TF-UL1727-16-NPC, TF-UL1727-12-NPC, TF-UL1727-8-NPC, TF-UL10362-22-NPC, TF-UL10362-18-NPC, TF-UL1726-20-NPC.
Specify nickel-plated copper (NPC) for continuous +250 °C duty; choose silver-plated copper (SPC, +200 °C max) when rapid low-temperature rosin-free hand soldering is prioritized over +250 °C oxidation resistance.
UL 758 (1726/1727/10362), ASTM B355 & Flame Standards
| Standard or specification | Application |
|---|---|
| UL 758 (Engineered to AWM Styles 1726, 1727, 10362, 1709 & 1710) | Wall thickness, 2,000–2,500 V AC dielectric withstand, 6,000 V spark test, +250 °C oven aging and VW-1 flame parameters (third-party UL/CSA mark not claimed). |
| ASTM B355 & ASTM B298 | Nickel-coated and silver-coated soft annealed copper conductor stranding and DC resistance limits. |
| IEC 60332-1-2 | Vertical single-wire flame self-extinguishing performance. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and 6,000 V inline spark test verification
UL 758 — Standard for Appliance Wiring Material (AWM)
ASTM B355 — Standard Specification for Nickel-Coated Soft or Annealed Copper Wire
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
FEP Hook-Up Wire — UL 1330, UL 1331, UL 1332 & UL 1333 Wire (150–200 °C, 300/600 V)
A related cable option for a different application or duty profile.
View productPTFE Hook-Up Wire — UL 1180, UL 1199, UL 1213, UL 1815 & UL 1584 (200–260 °C)
A related cable option for a different application or duty profile.
View productTGGT Wire — UL 5256, UL 5196 & UL 5257 PTFE-Glass Lead Wire (250 °C, 300/600 V)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.