High Temperature Cables TEBAOFLEX

PFA Hook-Up Wire — UL 1726, UL 1727 & UL 10362 Extruded Wire (250 °C, 300/600 V)

PFA single-core high-temperature hook-up wires engineered to UL 1726 (300 V, 13 mil), UL 1727 (600 V, 20 mil), UL 10362 (600 V, 10–12 mil thin-wall) and UL 1709 / UL 1710 specifications (TF-UL-PFA-1726-1727) deliver PTFE-equivalent -80 °C to +250 °C (+260 °C peak) thermal and chemical immunity in 100 % continuous, splice-free melt-extruded lengths (30 AWG to 2 AWG, 305 m / 500 m spools; third-party UL mark not claimed).

Product information
SKU
TF-UL-PFA-1726-1727
Brand
TEBAOFLEX
Product overview

PFA single-core equipment wires engineered to UL 758 AWM Styles 1726, 1727, 10362, 1709 and 1710 combine +250 °C continuous service (+260 °C peak) and universal chemical inertness with continuous melt-extrusion consistency, spanning 0.91 mm miniature 30 AWG sensor leads up to 10.3 mm 2 AWG (33.6 mm²) heavy furnace and rectifier feeders.

Conventional paste-extruded PTFE hook-up wires (UL 1180 / UL 1199) are ram-extruded from finite preformed billets, limiting continuous single-piece lengths on larger gauges and leaving microporous grain boundaries under pressurized acid vapour. Perfluoroalkoxy (PFA) incorporates perfluoroalkyl vinyl ether side chains that allow true high-temperature melt extrusion into pinhole-free, mirror-smooth walls with 2x higher flex-fatigue life and superior acid-vapour permeation resistance at +250 °C.

Specify thick-wall UL 1727 (600 V, 0.51–0.76 mm wall) for heavy industrial cabinets and power leads, thin-wall UL 10362 (600 V, 0.25–0.33 mm wall) for compact automated wire looms, or 300 V UL 1726 for instrumentation racks, routine 6,000 V spark-tested on continuous splice-free spools with full conductor resistance verification (third-party UL/CSA mark not claimed; MOQ 305 m / 500 m spools, 7 to 45 working days).

Explore the high-temperature wire and cable range for related configurations.

Construction

PFA UL 1726, UL 1727 & UL 10362 Wire Construction

Extruded on corrosion-proof hastelloy/nickel-alloy high-temperature melt lines with laser concentricity control and 100 % inline AC spark testing.

Clean 2D engineering cross-section of UL 1727 extruded PFA hook-up wire showing concentric ruby-red perfluoroalkoxy wall over 19 circular nickel-plated copper strands
PFA hook-up wire cross-section: pinhole-free melt-extruded perfluoroalkoxy insulation directly over ASTM B355 nickel-plated copper strands.
PFA Hook-Up Wire — UL 1726, UL 1727 & UL 10362 Extruded Wire (250 °C, 300/600 V) construction
ComponentMaterial and construction
1. Plated Stranded Copper Conductor (30 AWG to 2 AWG)Concentric or unidirectional stranded nickel-plated copper (ASTM B355, rated +250/+260 °C continuous) or silver-plated copper (ASTM B298, rated +200 °C); tinned copper available on +150 °C UL 1709/1710.
2. Melt-Extruded Virgin PFA Fluoropolymer WallTranslucent or solid-pigmented high-purity perfluoroalkoxy wall: 0.25–0.33 mm on UL 10362 / UL 1726, or 0.51–0.76 mm heavy wall on UL 1727.
3. Colour Coding & Optional Helical StripesNatural translucent amber-clear (for ultra-high-purity cleanroom/chemical inspection) or 10 solid colours (black, white, red, blue, yellow, green, brown, orange, violet, grey).

UL 1726, UL 1727 & UL 10362 Style Breakdown

  • UL 1727: 600 V AC, +250 °C standard thick-wall (0.51–0.76 mm / 20–30 mil) extruded PFA wire
  • UL 10362: 600 V AC, +250 °C thin-wall (0.25–0.33 mm / 10–13 mil) space-saving extruded PFA wire
  • UL 1726: 300 V AC, +250 °C medium-wall (0.33 mm / 13 mil) extruded PFA appliance wire
  • NPC (ASTM B355): Nickel-plated annealed copper conductor required for continuous +250/+260 °C duty
  • SPC (ASTM B298): Silver-plated copper conductor option for +200 °C low-resistance solderable harnesses
Applications

PFA Semiconductor Wet-Bench, Downhole & Oven Duty

Chosen whenever an application requires +250 °C thermal endurance PLUS continuous splice-free spool lengths or pressurized wet-chemical permeation immunity.

Ruby-red and natural translucent UL 1727 and UL 10362 PFA hook-up wires routed through fluoropolymer bulkheads inside a semiconductor wet-process cabinet
Chemical-impervious PFA equipment harnesses installed in a high-purity wet-etch process module.
  • Semiconductor wet-bench acid/solvent distribution cabinets, quartz heater leads, CVD/ALD gas-box harnesses and ultra-pure DI water heaters.
  • Downhole oil/gas logging tools, submersible chemical-injection pump leads and high-pressure autoclave feedthrough wiring.
  • Industrial UV curing lamps, commercial pizza/convection deck ovens, glass tempering equipment and plastics hot-runner heater zones.
  • Cryogenic liquid-nitrogen (-196 °C static) and pharma lyophilizer sensor/valve harnesses requiring zero plasticiser extractables.

PFA (UL 1727 / 10362) vs PTFE vs FEP vs ETFE

PFA (UL 1727 / 10362) vs PTFE (UL 1180 / 1199) vs FEP (UL 1330 / 1332) vs ETFE (UL 10086)
Fluoropolymer WireContinuous Temp.Extrusion & Length CapabilityBest Engineering Fit
PFA — UL 1726 / 1727 / 10362 (this page)-80 °C to +250 °CMelt-extruded 100 % splice-free continuous spools250 °C wet acid benches, long automated looms & heavy 8–2 AWG leads
PTFE — UL 1180 / 1199 / 1213-190 °C to +200/+260 °CPaste-extruded sintered billets (solder-iron proof)Hand-soldered electronics, UHV vacuum & cryogenic leads
FEP — UL 1330 / 1332-70 °C to +200 °CMelt-extruded continuous spools (most economical)General +200 °C ovens, appliances & sensor harnesses
ETFE — UL 10086 / 1516-70 °C to +150/+200 °CMelt-extruded high-stiffness engineering wallHigh-abrasion robotics, stator windings & radiation zones

Whenever automated Komax/Schleuniger cut-strip lines require zero billet splices at +250 °C, UL 10362 or UL 1727 PFA outperforms paste-extruded PTFE.

PFA Hook-Up Wire (UL 1726 / 1727 / 10362) RFQ Checklist

  • Target UL style reference: UL 1727 (600 V 20 mil), UL 10362 (600 V 10 mil thin-wall) or UL 1726 (300 V 13 mil).
  • AWG size (30 AWG to 2 AWG) and stranding (solid, 7-strand, 19-strand, 37-strand or 133/665-strand).
  • Conductor plating: nickel-plated copper (NPC, +250 °C) or silver-plated copper (SPC, +200 °C).
  • Insulation colour (natural translucent or solid colour) and spool quantity (MOQ 305 m / 1,000 ft or 500 m, 7 to 45 working days).

Related selection resources

PFA Hook-Up Wire Frequently Asked Questions

What is the difference between UL 1727, UL 10362 and UL 1726 PFA hook-up wire?

Wall thickness and voltage rating: UL 1727 uses a 20 mil (0.51 mm) heavy wall for 600 V rugged cabinet power, UL 10362 achieves the same 600 V and +250 °C rating in a compact 10–12 mil (0.25–0.30 mm) thin wall, and UL 1726 uses a 13 mil (0.33 mm) wall for 300 V internal harnesses.

Why specify PFA hook-up wire instead of PTFE hook-up wire when both handle +250 °C?

2 process advantages: melt-extruded PFA is delivered on 100 % splice-free continuous 305 m / 500 m spools (including heavy 8–2 AWG power sizes that PTFE paste extruders cannot run), and dense melt-formed PFA blocks hot acid-vapour permeation better than sintered PTFE.

Can PFA UL 1727 and UL 10362 wire withstand direct soldering-iron contact like PTFE?

No — unlike non-melting sintered PTFE (+327 °C gel point), thermoplastic PFA melts around +305 °C to +310 °C, so use controlled-temperature soldering irons or crimp terminals to avoid insulation nicking.

Do TEBAOFLEX UL 1726, UL 1727 and UL 10362 PFA wires carry a third-party UL Recognition mark?

No — TEBAOFLEX manufactures these PFA wires engineered to UL 758 Style 1726, 1727 and 10362 dimensional, spark-test and +250 °C aging specifications (third-party UL/CSA mark is not claimed).

What is the minimum order quantity and delivery lead time for PFA hook-up wire?

305 m (1,000 ft) or 500 m continuous spools per colour and gauge, manufactured and spark-tested in 7 to 45 working days.

Specifications

UL 1727 (600 V Thick) & UL 10362 / UL 1726 Schedules

PFA Voltage, Plating, Chemical Permeation & Spool Summary

  • Splice-free 250 °C perfluoropolymer: Melt-extrudable perfluoroalkoxy (PFA) matches PTFE's +250/+260 °C rating and 2.1 dielectric constant while eliminating billet paste-extrusion joints
  • Complete 300 V & 600 V style coverage: Covers UL 1727 (600 V standard 0.51 mm wall), UL 10362 (600 V space-saving 0.25–0.30 mm thin wall) and UL 1726 (300 V 0.33 mm wall)
  • NPC (+250 °C) & SPC (+200 °C) copper: Stranded 7-, 19-, 37-, 133- or 665-wire nickel-plated copper (ASTM B355, +250 °C) or silver-plated copper (ASTM B298, +200 °C) from 30 AWG to 2 AWG
  • Ultra-pure wet-chemical barrier: Near-zero extractables and < 0.01 % moisture absorption survive hot HF/HNO3 semiconductor etchants, sour downhole fluids and steam
  • Standard 305 m / 500 m spools: Supplied on continuous spark-tested 305 m (1,000 ft) or 500 m factory spools per colour in 7 to 45 working days
PFA Hook-Up Wire — UL 1726, UL 1727 & UL 10362 Extruded Wire (250 °C, 300/600 V) technical data
ParameterValue
Rated voltage600 V AC on Styles 1727 and 10362 (2500 V AC dielectric test, 6000 V spark test) and 300 V AC on Style 1726 (2000 V AC dielectric test)
Conductor and gauge range30 AWG to 2 AWG (0.05 mm2 to 33.6 mm2) in stranded (7, 19, 37, 133 or 665 wires) or solid nickel-plated or silver-plated copper
Fluoropolymer insulation system100% virgin melt-extruded perfluoroalkoxy (PFA) with 2.1 dielectric constant, under 0.01% water absorption and UL VW-1 / FT1 flame resistance
Operating temperature and bend radius-80 C (-190 C static) to +250 C continuous (+260 C short-term) with nickel-plated copper; 5x OD minimum fixed bend radius
Standard put-up and lead time305 m (1000 ft) or 500 m continuous splice-free factory spools per colour (MOQ 305 m) in 7 to 45 working days
Standards compliance noteEngineered and manufactured to UL 758 AWM Styles 1726, 1727, 10362, 1709 and 1710 dimensional and electrical criteria (third-party UL/CSA mark is not claimed)
Chemical and permeation resistanceLower gas/vapour permeability than sintered PTFE; completely inert to fuming acids, strong bases, halogens, ketones and synthetic oils

UL 1727 (600 V Thick-Wall, 250 °C) Extruded PFA Wire Schedule

UL 1727 (600 V Thick-Wall, 250 °C) Extruded PFA Hook-Up Wire — Dimensional, Resistance & Weight Schedule (26 AWG to 2 AWG)
Style & AWG GaugeStranding (Wires/AWG)Conductor Ø (mm)Nom. PFA Wall (mm / mil)Nom. OD (mm / in)Max. R at 20 °C (Ω/km NPC)Approx. Weight (kg/km)Standard Spool MOQNext step
UL 1727 26 AWG (NPC)19/380.480.51 / 201.50 / 0.059140.05.2305 m / 500 mRequest this size
UL 1727 24 AWG (NPC)19/360.610.51 / 201.63 / 0.06488.96.5305 m / 500 mRequest this size
UL 1727 22 AWG (NPC)19/340.750.51 / 201.85 / 0.07351.58.5305 m / 500 mRequest this size
UL 1727 20 AWG (NPC)19/320.960.51 / 202.06 / 0.08131.811.4305 m / 500 mRequest this size
UL 1727 18 AWG (NPC)19/301.190.51 / 202.31 / 0.09120.015.6305 m / 500 mRequest this size
UL 1727 16 AWG (NPC)19/291.350.51 / 202.46 / 0.09715.619.2305 m / 500 mRequest this size
UL 1727 14 AWG (NPC)19/271.690.51 / 202.82 / 0.1119.8426.6305 m spoolRequest this size
UL 1727 12 AWG (NPC)19/252.130.51 / 203.35 / 0.1326.2039.3305 m spoolRequest this size
UL 1727 10 AWG (NPC)37/262.740.51 / 203.96 / 0.1564.0357.9305 m spoolRequest this size
UL 1727 8 AWG (NPC)133/294.140.76 / 305.84 / 0.2302.28108.0305 m spoolRequest this size
UL 1727 6 AWG (NPC)133/275.180.76 / 306.91 / 0.2721.43161.0305 m spoolRequest this size
UL 1727 4 AWG (NPC)133/256.500.76 / 308.31 / 0.3270.90246.0305 m spoolRequest this size
UL 1727 2 AWG (NPC)665/308.380.76 / 3010.31 / 0.4060.56385.0305 m spoolRequest this size

UL 10362 (600 V Thin-Wall) & UL 1726 (300 V) PFA Wire Schedule

UL 10362 (600 V Thin-Wall, 250 °C) & UL 1726 (300 V, 250 °C) Space-Saving PFA Wire Schedule
Style & AWG GaugeVoltage / Temp.Stranding (Wires/AWG)Nom. PFA Wall (mm / mil)Nom. OD (mm / in)Approx. Weight (kg/km)Standard Spool MOQNext step
UL 10362 28 AWG (NPC)600 V / 250 °C7/360.25 / 100.89 / 0.0352.1305 m / 500 mRequest this size
UL 10362 26 AWG (NPC)600 V / 250 °C19/380.25 / 100.99 / 0.0392.8305 m / 500 mRequest this size
UL 10362 24 AWG (NPC)600 V / 250 °C19/360.25 / 101.12 / 0.0443.9305 m / 500 mRequest this size
UL 10362 22 AWG (NPC)600 V / 250 °C19/340.25 / 101.27 / 0.0505.5305 m / 500 mRequest this size
UL 10362 20 AWG (NPC)600 V / 250 °C19/320.25 / 101.47 / 0.0588.2305 m / 500 mRequest this size
UL 10362 18 AWG (NPC)600 V / 250 °C19/300.25 / 101.73 / 0.06812.1305 m / 500 mRequest this size
UL 10362 16 AWG (NPC)600 V / 250 °C19/290.30 / 122.03 / 0.08016.8305 m / 500 mRequest this size
UL 10362 14 AWG (NPC)600 V / 250 °C19/270.33 / 132.41 / 0.09525.4305 m spoolRequest this size
UL 1726 24 AWG (NPC)300 V / 250 °C19/360.33 / 131.27 / 0.0504.5305 m / 500 mRequest this size
UL 1726 20 AWG (NPC)300 V / 250 °C19/320.33 / 131.63 / 0.0649.1305 m / 500 mRequest this size
UL 1726 16 AWG (NPC)300 V / 250 °C19/290.33 / 132.06 / 0.08117.0305 m / 500 mRequest this size

ASCII part references for BOM entry: TF-UL1727-24-NPC, TF-UL1727-20-NPC, TF-UL1727-16-NPC, TF-UL1727-12-NPC, TF-UL1727-8-NPC, TF-UL10362-22-NPC, TF-UL10362-18-NPC, TF-UL1726-20-NPC.

Specify nickel-plated copper (NPC) for continuous +250 °C duty; choose silver-plated copper (SPC, +200 °C max) when rapid low-temperature rosin-free hand soldering is prioritized over +250 °C oxidation resistance.

Standards

UL 758 (1726/1727/10362), ASTM B355 & Flame Standards

PFA Hook-Up Wire — UL 1726, UL 1727 & UL 10362 Extruded Wire (250 °C, 300/600 V) standards and test references
Standard or specificationApplication
UL 758 (Engineered to AWM Styles 1726, 1727, 10362, 1709 & 1710)Wall thickness, 2,000–2,500 V AC dielectric withstand, 6,000 V spark test, +250 °C oven aging and VW-1 flame parameters (third-party UL/CSA mark not claimed).
ASTM B355 & ASTM B298Nickel-coated and silver-coated soft annealed copper conductor stranding and DC resistance limits.
IEC 60332-1-2Vertical single-wire flame self-extinguishing performance.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and 6,000 V inline spark test verification

UL 758 — Standard for Appliance Wiring Material (AWM)

ASTM B355 — Standard Specification for Nickel-Coated Soft or Annealed Copper Wire

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.