MINING & TUNNELING CABLES TEBAOFLEX

NSSHKCGERLOEU 0.6/1kV Armoured Coal Cutter Cable

NSSHKCGERLOEU 0.6/1 kV armoured coal cutter cable for mobile mining machines exposed to extreme bending, tensile, torsional, impact and squeezing loads.

  • Conductor: particularly fine stranded tinned copper.
  • Insulation: heat-resistant 3GI3 EPR rubber compound.
  • Auxiliary units: flexible copper/steel pilot conductors with distributed earth conductors.
  • Armour: tensile- and torsion-resistant steel-wire braid.
  • Outer sheath: yellow 5GM5 chlorinated rubber compound.
  • Standard reference: DIN VDE 0250 Part 812.

Send the cable marking, conductor size, machine, pulley or reel data, length and documentation requirements for RFQ review.

Product information
Brand
TEBAOFLEX
Product overview

NSSHKCGERLOEU Armoured Coal Cutter Cable for Mobile Mining Machines

NSSHKCGERLOEU is a 0.6/1 kV armoured coal cutter cable for mobile mining machines operating under very high mechanical loads. The documented construction combines particularly fine stranded tinned-copper power conductors, heat-resistant 3GI3 EPR insulation, pilot/earth units, a conducting rubber cradle and inner sheath, taping, steel-wire braid armour and a yellow 5GM5 outer sheath.

The cable is intended for coal-cutting machines and comparable mobile equipment exposed to extreme bending, high mechanical tension, impact and squeezing. Its torsion- and tensile-stress-resistant armour, together with the flexible cable construction, also supports operation over guide pulleys or use as an LHD reeling cable. Selection must still match the machine route, cable diameter, reel or pulley geometry, bending mode, pull, terminations and pilot/earth arrangement.

  • Voltage: 0.6/1 kV.
  • Movement: static, flexing, guide-pulley or drum operation within the documented limits.
  • Mechanical focus: bending, tensile, torsional, impact and squeezing loads.

Do not substitute NSSHKCGERLOEU with a similarly named coal cutter cable without comparing the complete construction and machine duty. Review the mining and tunneling cable range and mining cable selection guide, then send the existing marking and application data for quotation review.

Construction

NSSHKCGERLOEU Armoured Coal Cutter Cable Construction

The construction below is transcribed from the supplied NSSHKCGERLOEU reference. Final conductor layout, pilot/earth notation, layer dimensions and cable marking must be confirmed on the quotation drawing.

NSSHKCGERLOEU armoured coal cutter cable cross section showing power cores, pilot earth units, inner sheath and steel wire braid
NSSHKCGERLOEU cross-section showing the armoured coal cutter cable layer arrangement.
NSSHKCGERLOEU cable construction
LayerSource-listed constructionSelection relevance
Power conductorParticularly fine stranded tinned-copper wires in a special flexible designFlexible power cores for mobile mining equipment.
Power-core insulationColoured heat-resistant 3GI3 rubber compound on an EPR basis, with high mechanical strengthInsulation system for the documented 0.6/1 kV construction.
Core wrappingRubberized textile tapePart of the documented core assembly.
Pilot coresExpansion- and compression-capable copper/steel conductors with 3GI3 EPR-based insulationAuxiliary conductors designed to accommodate cable movement.
Earth conductorFine copper-wire strands around the pilot-core insulation plus fine stranded tinned copper in the cradle separatorDistributed earth-conductor arrangement that must match the termination design.
Lay-upCores laid over a central cradle separator of conducting rubber, with pilot/earth units in the intersticesDefines the model-specific internal arrangement.
Inner sheathConducting rubber compound with tapingBedding beneath the armour.
ArmourSteel-wire braidDocumented tensile- and torsion-resistant reinforcement.
Outer sheathYellow 5GM5 chlorinated rubber compound; abrasion-, tear-, oil- and flame-resistantExternal protection listed for the supplied construction.

Where the braid sits, and why that changes the earth path

Three coal cutter designations in this family are routinely read as interchangeable because two of them are described as braided and armoured. They are not interchangeable, and the difference is not the braid itself but what the braid is for.

Saddle-separator and braided coal cutter designations compared
DesignationCentral separatorEarth conductorBraidMinimum bending radius
NSSHKCGERLOEU, this pageCentral cradle separator of conducting rubberDistributed: fine copper strands around the signalling-core insulation, plus fine stranded tinned copper in the separatorBraiding of steel wires, over the taping above the conducting-rubber inner sheath. Armour only2 × D static; 3 × D flexing; 4.5 × D in guide pulleys and on drums
NSSHKCGEOEUCentral cradle separator of conducting rubberDistributed, as aboveNone1.5 × D fixed; 2.5 × D flexing
NSSHCGEOEU, high-tensile buildNoneThe concentric earth conductor is the braidBraided armour of combined copper-steel wires, serving as both earth conductor and tensile member2 × D static; 3 × D flexing; 4.5 × D in guide pulleys and on drums

The consequence is practical. On this cable the earth path is independent of the armour, so the armour can be sized for the mechanical duty without changing the earth arrangement. On the copper-steel build the braid is the earth conductor, so damage to the braid is damage to the earth path and the termination has to pick up the earth from the braid itself. Substituting one for the other changes the earth continuity behaviour and the termination design even where the conductor sizes match.

Compare NSSHKCGEOEU for the same saddle construction without the armour, and NSSHCGEOEU high-tensile coal cutter cable for the copper-steel braid that doubles as the earth conductor. For the low-tensile spiral-earth build see NSSHCGEOEU low-tensile coal cutter cable.

Reading the braid tensile strength

The tabulated braid tensile strength is not the permitted working pull. It is the strength of the braid itself, published as 57 kN for the 3 × 16 to 3 × 35 mm² builds and 85 kN from 3 × 50 mm² upward. Deriving an allowable operating load from it requires a safety factor, the termination design and the movement data for the route, so state the machine, the reel or pulley arrangement and the expected pull with the enquiry rather than sizing from the kN figure alone.

Why this designation is specified where the cable can be trapped

Like the unarmoured saddle build, this cable meets the requirements of draft DIN VDE 0472 Part 818, "Behaviour under Squeezing Stress": squeezing damage is detected as an earth fault with the highest achievable reliability. That detection behaviour, combined with the torsion- and tensile-resistant armour, is why the designation is chosen for routes where the cable is both pulled and at risk of being run over or crushed.

Reference note: enquiries arriving marked TENAX-ZE or SCHRÄM-TENAX-ZE are handled on this page; TEBAOFLEX manufactures to the NSSHKCGERLOEU designation and the construction shown, and is not affiliated with the trademark holder.

Applications

NSSHKCGERLOEU Coal Cutter Cable Applications

NSSHKCGERLOEU is intended to connect mobile machines under very high mechanical loads, predominantly in mining applications. The supplied reference specifically identifies coal-cutting machines and routes involving extreme bending, high mechanical tension, impact and squeezing.

NSSHKCGERLOEU armoured coal cutter cable on underground mobile mining equipment
NSSHKCGERLOEU application reference for underground coal-cutting and mobile mining equipment.
  • Coal-cutting machines and comparable mobile underground mining equipment.
  • Guide-pulley or cable-car routes after pulley geometry and bending conditions are verified.
  • LHD reeling cable duty after reel dimensions, winding layers and tensile path are checked.
  • Routes where steel-wire braid reinforcement is required for the documented tensile and torsional duty.
  • Applications exposed to bending, impact or squeezing within the confirmed cable and installation limits.

Application boundaries

The model name does not establish automatic compatibility with every coal cutter, reel or monitoring system. Confirm the existing marking, voltage, load, core and pilot/earth arrangement, cable length, static or moving route, pulley or drum dimensions, speed, pull, reverse bending, terminations and required project documents.

Related coal cutter cable references

Compare NSSHCGEOEU high-tensile coal cutter cable, NSSHKCGEOEU trailing cable and NTSKCGECWOEU medium-voltage chain cable by voltage, internal construction and movement duty. None is an automatic substitute for NSSHKCGERLOEU.

Reference designation cross-reference

This armoured coal cutter cable is catalogued under two reference names for the same build.

Reference designation cross-reference
Reference designationTEBAOFLEX designation and buildRated voltageWhat the reference name marks
TENAX-ZE / NSSHKCGERLOEUNSSHKCGERLOEU armoured coal cutter cable0.6/1 kVPlain steel armour with a distributed earth, not a copper-steel braid earth
SCHRÄM-TENAX-ZE / NSSHKCGERLOEUNSSHKCGERLOEU armoured coal cutter cable0.6/1 kVThe same build listed for coal cutting machines and LHDs

For the full list of reference designations and the TEBAOFLEX build each one maps to, see the mining cable designation cross-reference.

Trademark note: TENAX®, TROMMELFLEX®, FELTOFLEX® and SCHRÄM® are trademarks of their respective owners, and TEBAOFLEX is neither affiliated with those companies nor reselling their cable. What we supply is the equivalent construction: we manufacture to the same VDE type designation and published construction, and every designation listed here can be quoted and supplied as a TEBAOFLEX build. The names appear so that an enquiry written in those terms reaches the matching construction, which is made to the standards and construction confirmed for the order.

Specifications

NSSHKCGERLOEU 0.6/1 kV Cable Specifications

Operating data for the NSSHKCGERLOEU armoured coal cutter cable
Rated voltage U₀/U0.6/1 kV
Cable-surface temperature, static-40 °C to +80 °C
Cable-surface temperature, flexing-25 °C to +80 °C
Minimum bending radius, static2 × D
Minimum bending radius, flexing3 × D
Minimum bending radius, guide pulleys and drums4.5 × D
Diameter notationD = cable diameter

NSSHKCGERLOEU size, electrical and armour data

Values are approximate source data. Confirm the final diameter, weight, electrical values, braid tensile strength and core notation before manufacture.

Core configurationOuter diameterWeightInductive resistance at 50 HzPhase-monitor capacitanceBraid tensile strength
NSSHKCGERLOEU 3 × 16 + 3 × (ST + 16/3)37-40.5 mm2130 kg/km0.118 Ω/km0.38 µF/km57 kN
NSSHKCGERLOEU 3 × 25 + 3 × (ST + 16/3)41.5-45 mm2730 kg/km0.108 Ω/km0.42 µF/km57 kN
NSSHKCGERLOEU 3 × 35 + 3 × (ST + 16/3)44.5-48 mm3240 kg/km0.102 Ω/km0.49 µF/km57 kN
NSSHKCGERLOEU 3 × 50 + 3 × (ST + 25/3)51-55 mm4420 kg/km0.101 Ω/km0.52 µF/km85 kN
NSSHKCGERLOEU 3 × 70 + 3 × (ST + 35/3)55-59 mm5470 kg/km0.095 Ω/km0.61 µF/km85 kN
NSSHKCGERLOEU 3 × 95 + 3 × (ST + 50/3)62-66 mm6890 kg/km0.092 Ω/km0.61 µF/km85 kN
NSSHKCGERLOEU 3 × 150 + 3 × (ST + 70/3)71.5-75.5 mm9750 kg/km0.087 Ω/km0.70 µF/km85 kN
Standards

NSSHKCGERLOEU Standards and Order Documentation

Standards referenced in the supplied NSSHKCGERLOEU data
ReferenceSource-listed relationshipOrder confirmation
DIN VDE 0250 Part 812Cable standard referenceState the required edition and full cable designation.
Draft DIN VDE 0472 Part 818, Behaviour under Squeezing StressThe supplied reference states that the cable meets the requirements of this draft test standardConfirm the required test method, edition and documentation scope.

The source explains that squeezing damage is intended to be detected as an earth fault through the documented pilot/earth arrangement. The order package should identify the machine, monitoring interface, cable marking, core arrangement, nominal size, drum schedule, routine electrical tests and any project inspection or documentation requirements.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.