NSGAFCMOEU 3.6/6kV Screened Heating Circuit Cable
NSGAFCMOEU 3.6/6 kV screened single-core cable to DIN VDE 0250 Parts 602 and 606, for heating circuit connections under higher mechanical stressing, with the halogen-free NSHXAFCMOE option.
- Conductor: flexible tinned copper, class 5.
- Insulation: EPR compound type 3GI3 with inner semi-conducting layer.
- Screen: helix of tinned copper wires (CMOE).
- Sheath: 5GM3 chlorinated rubber, or HM3 halogen-free.
- Cross-section: 185 mm².
Send vehicle type, heating circuit rating and termination details for RFQ review.
NSGAFCMOEU Screened Heating Circuit Cable
NSGAFCMOEU is a 3.6/6 kV screened single-core cable to DIN VDE 0250 Parts 602 and 606, designed for higher mechanical stressing, typically as the connection element for heating circuits in trucks, buses and track-bound vehicles. The screen, denoted by the CMOE letters, is a helix of tinned copper wires laid over the insulation; it is what separates this cable from the unscreened NSGAFÖU base build.
The page also covers NSHXAFCMOE, the halogen-free equivalent. The two share the screened construction and differ in sheath compound, and that difference changes the bending radius: 4 × D for the chlorinated-rubber NSGAFCMOEU against 6 × D for the halogen-free NSHXAFCMOE. Both are supplied in 185 mm², which is the maximum cross-section that DIN VDE 0250 Part 602 sets for this voltage class.
- Rated voltage: 3.6/6 kV.
- Screen: helix of tinned copper wires (CMOE).
- Cross-section: 185 mm², the Part 602 ceiling for this class.
- Bending radius: 4 × D screened chlorinated rubber; 6 × D screened halogen-free.
For the unscreened base builds use NSGAFÖU and NSHXAFÖ, which cover 1.5 mm² to 300 mm² and are a different specification entirely.
NSGAFCMOEU Cable Construction
Four-layer screened single-core construction. The inner semi-conducting layer is present on the 6 kV build, and the CMOE screen sits between the insulation and the sheath.

| No. | Layer | Construction |
|---|---|---|
| 1 | Conductor | Flexible tinned copper conductor, class 5 |
| 2 | Semi-conducting layer | Inner semi-conducting layer, present on the 6 kV type |
| 3 | Insulation | Rubber compound type 3GI3, EPR based |
| 4 | Screen (CMOE) | Helix of tinned copper wires |
| 5 | Sheath | 5GM3 chlorinated rubber, or HM3 halogen-free polymer compound |
Screened family members
| Designation | Screen | Sheath compound | Minimum bending radius | Covered here |
|---|---|---|---|---|
| NSGAFCMOEU | CMOE tinned copper helix | 5GM3 chlorinated rubber, oil resistant, self-extinguishing | 4 × D | Yes |
| NSHXAFCMOE | CMOE tinned copper helix | HM3 halogen-free, oil resistant, self-extinguishing, low smoke | 6 × D | Yes |
| NSGAFÖU | None | 5GM3 chlorinated rubber | 4 × D | No, see the NSGAFÖU page |
| NSHXAFÖ | None | HM3 halogen-free | 6 × D | No, see the NSHXAFÖ page |
NSGAFCMOEU Applications
The screened CMOE builds are designed for higher mechanical stressing, for instance as the connection element for heating circuits in trucks, buses and track-bound vehicles. The unscreened builds of the same family are used for fixed installation in vehicles, in conduits and closed installation systems, and in low-voltage switchboards; those applications stay on their own pages.

- Heating circuit connections in trucks, buses and track-bound vehicles.
- Routes with higher mechanical stressing than the unscreened build is rated for.
- Installations requiring a metallic screen over a single-core medium-voltage connection.
- Halogen-free variants where low smoke emission is specified, using NSHXAFCMOE.
Application boundaries
The screened builds are supplied in 185 mm² only. Do not read the 1.5 mm² to 300 mm² range of the unscreened NSGAFÖU and NSHXAFÖ tables across to this page; those are different cables with a different construction and different current ratings. State the screen termination and earthing method, the heating circuit rating and the vehicle interface with the enquiry.
Related single-core references
Compare NSGAFÖU and NSHXAFÖ for the unscreened base builds, and NTMCGCWÖU for the screened medium-voltage single-core range from 3.6/6 kV to 18/30 kV.
Reference note: enquiries arriving marked NSGAFCMÖU or NSGAFCMOU are handled on this page; umlaut and OE spellings refer to the same designation.
NSGAFCMOEU Specifications
| Rated voltage U₀/U | 3.6/6 kV |
|---|---|
| Standard | DIN VDE 0250 Parts 602 and 606 |
| Conductor | Flexible tinned copper, class 5 |
| Screen | CMOE, helix of tinned copper wires |
| Minimum bending radius, NSGAFCMOEU | 4 × D |
| Minimum bending radius, NSHXAFCMOE | 6 × D |
| Temperature range, fixed installation | -40 °C to +80 °C |
| Temperature range, flexing | -25 °C to +80 °C |
| Sheath colour | Black |
| Diameter notation | D = cable diameter |
NSGAFCMOEU and NSHXAFCMOE 3.6/6 kV size table
| Code and cross-section | Outer diameter approx. | Weight approx. | Sustained current loading | Nominal fire load, halogen-free build |
|---|---|---|---|---|
| NSGAFCMOEU / NSHXAFCMOE 3.6/6 kV 185 mm² | 38.5 mm | 3060 kg/km | 622 A | 4.58 kWh/m |
185 mm² is the maximum cross-section that DIN VDE 0250 Part 602 specifies for this voltage class, so the single-row table is the complete screened range rather than an extract. Sustained current loading is stated at 30 °C ambient, free in air, as in DIN VDE 0298 Part 4 Table 11, and must be corrected for the installed condition. The nominal fire load figure applies to the halogen-free NSHXAFCMOE build.
NSGAFCMOEU Standards, Approvals and Order Documentation
| Reference | Scope | Order confirmation |
|---|---|---|
| DIN VDE 0250 Part 602 | Special single-core cables; also sets the 185 mm² ceiling for this voltage class | State the designation and screen requirement. |
| DIN VDE 0250 Part 606 | Halogen-free single-core cables | Applies to the NSHXAFCMOE build. |
| DIN VDE 0298 Part 4 | Current rating, Table 11 free in air at 30 °C | Derate for the installed condition. |
Approvals
| Approval | Status |
|---|---|
| Manufacturing conformity, DIN VDE 0250 Parts 602 and 606 | Held |
| EN 45545-2 rail vehicle fire performance, halogen-free build | Held |
| Routine electrical test package for the screened 3.6/6 kV build | Held |
Order package
State whether the chlorinated-rubber or halogen-free sheath is required, the heating circuit rating, screen termination and earthing method, vehicle type and interface, installation route and bending condition, required lengths, and any project fire, marking or documentation scope.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
NSGAFÖU 1.8/3kV Single-Core Rubber Cable
A related cable option for a different application or duty profile.
View productNSHXAFÖ 1.8/3kV Halogen-Free Rubber Cable
A related cable option for a different application or duty profile.
View productNTMCGCWÖU Single-Core MV Cable 3.6/6kV to 18/30kV
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.