Flat Type G 2C Mining Cable with Ground, 2 kV
Flat Type G 2C cable is a 2 kV mining trailing cable with two power conductors and one shaped grounding conductor.
- Flexible tinned-copper conductors.
- EPR insulation with black and white power-core identification.
- One grounding conductor between the power cores.
- Textile reinforcement and a black CPE jacket.
- Sizes: 6, 4, 2, 1, 1/0 and 2/0 AWG.
- Maximum continuous conductor temperature: 90 °C.
Flat Type G 2C cable for DC mining equipment
Flat Type G 2C cable is a 2 kV trailing cable with two power cores and one shaped grounding conductor. Its flat assembly combines flexible tinned-copper conductors, EPR insulation, synthetic-yarn reinforcement and a black CPE jacket.
This arrangement serves two-conductor DC circuits on off-track mining equipment, including shuttle cars, drills, cutters and loading machines. The grounding conductor lies between the two insulated power cores. The separate power and protective-ground functions are visible in the construction diagram and in the size-specific conductor schedule.
- Circuit selection: match the two power conductors and grounding-conductor size to the equipment drawing.
- Size selection: compare six AWG options together, from 6 AWG to 2/0 AWG.
- Route clearance: use both cable height and width when checking guides, equipment entries and termination space.
- Thermal selection: the ampacity table states continuous-duty values at 90 °C conductor temperature and 40 °C ambient.
This Type G construction has one grounding conductor and no separate ground-check core. Browse the mining cable range for other conductor arrangements, or read the grounding and ground-check cable comparison when selecting the protection-circuit configuration.
Two power conductors and one shaped ground
The flat assembly places one flexible grounding conductor between two EPR-insulated power cores. Synthetic yarn reinforces the assembly beneath the CPE outer jacket.

| Element | Construction |
|---|---|
| Power conductors | Two flexible tinned-copper conductors |
| Insulation | EPR |
| Power-core identification | Black and white |
| Grounding conductor | One shaped flexible tinned-copper conductor between the power cores |
| Reinforcement | Synthetic textile yarn |
| Outer jacket | Black heavy-duty CPE |
| Ground-check core | None |
DC mining-equipment trailing connections
Flat Type G 2C serves two-conductor DC power circuits on off-track mining machinery.

- Shuttle cars: flat trailing leads with a separate protective-ground conductor.
- Drilling and cutting equipment: two-power-conductor DC connections matched to the machine circuit.
- Loading equipment: flexible cable connections between the supply and mobile machine.
Grounding and monitoring
This construction contains one grounding conductor and no separate ground-check core. For a monitored circuit, compare the Type G-GC cable with ground-check conductor.
Flat-cable routing
Use the finished height and width to check guide clearance and cable orientation. Maintain the intended bending plane and avoid twisting the flat assembly. Current-rating selection uses the installation method and the thermal conditions stated in Specifications.
Flat Type G 2C sizes and specifications
| Parameter | Value |
|---|---|
| Rated voltage | 2 kV |
| Power / ground arrangement | 2 power conductors + 1 grounding conductor |
| Maximum continuous conductor temperature | 90 °C |
| Ampacity ambient temperature | 40 °C |
| Nominal sizes shown | 6, 4, 2, 1, 1/0 and 2/0 AWG |
| Configuration | Wires per power conductor | Ground size (AWG) | Ground wires | EPR thickness (mil / mm) |
|---|---|---|---|---|
| Flat Type G 2C × 6 AWG | 133 (7 × 19) | 8 | 270 (6 × 45) | 60 / 1.524 |
| Flat Type G 2C × 4 AWG | 259 (7 × 37) | 7 | 180 (6 × 30) | 60 / 1.524 |
| Flat Type G 2C × 2 AWG | 259 (7 × 37) | 5 | 168 (6 × 28) | 60 / 1.524 |
| Flat Type G 2C × 1 AWG | 259 (7 × 37) | 4 | 168 (6 × 28) | 80 / 2.032 |
| Flat Type G 2C × 1/0 AWG | 259 (7 × 37) | 3 | 204 (6 × 34) | 80 / 2.032 |
| Flat Type G 2C × 2/0 AWG | 329 (7 × 47) | 2 | 246 (6 × 41) | 80 / 2.032 |
| Configuration | Height × width (in) | Height × width (mm) | Mass (lb/1000 ft) | Mass (kg/km) | Ampacity (A) |
|---|---|---|---|---|---|
| Flat Type G 2C × 6 AWG | 0.56 × 1.02 | 14.22 × 25.91 | 500 | 744 | 95 |
| Flat Type G 2C × 4 AWG | 0.61 × 1.15 | 15.49 × 29.21 | 660 | 982 | 127 |
| Flat Type G 2C × 2 AWG | 0.73 × 1.35 | 18.54 × 34.29 | 990 | 1473 | 167 |
| Flat Type G 2C × 1 AWG | 0.81 × 1.55 | 20.57 × 39.37 | 1230 | 1830 | 191 |
| Flat Type G 2C × 1/0 AWG | 0.93 × 1.67 | 23.62 × 42.42 | 1540 | 2292 | 217 |
| Flat Type G 2C × 2/0 AWG | 0.99 × 1.85 | 25.15 × 46.99 | 1870 | 2783 | 250 |
Ampacity is based on continuous duty at 90 °C conductor temperature and 40 °C ambient. Apply installation and grouping correction factors for the circuit. Dimensions and mass are nominal; metric figures are rounded conversions of the inch and lb/1000 ft values.
Flat Type G construction standards
The mining-cable design reference is ICEA S-75-381 / NEMA WC 58 — portable and mining power-feeder cables.
- ASTM B172: rope-lay-stranded copper conductors.
- ASTM B33: tinned soft or annealed copper wire.
- Rated voltage: 2 kV.
- Core arrangement: two power conductors and one grounding conductor.
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
Type G Cable 2 kV Portable Mining Power Cable
A related cable option for a different application or duty profile.
View productType G-GC Cable 2000V Portable Mining Power Cable
A related cable option for a different application or duty profile.
View productFour Conductor Flat Type W Cable 600/2000V for Mining Equipment
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.