XLPE / PE-X High Voltage Wire, 3–50 kV DC
Unshielded XLPE / PE-X high voltage wire for internal equipment wiring. HXW reference configurations use 24 AWG conductors at 3, 6 or 10 kV DC; jacketed HTV configurations use 22 AWG conductors at 20, 30 or 50 kV DC.
XLPE high voltage wire provides a compact, unshielded connection inside high voltage equipment. This family covers two distinct constructions: single-insulated HXW reference configurations at 3, 6 and 10 kV DC, and PE-X-insulated, PVC-jacketed HTV reference configurations at 20, 30 and 50 kV DC. Select the voltage and construction together before choosing the termination.
HXW uses a flexible, tinned copper 24 AWG conductor and irradiation-cross-linked polyethylene insulation. Its 1.60–1.90 mm outside diameters suit equipment layouts where lead size and routing space are important. The insulation is the external surface of the wire; this construction has no separate jacket or metallic screen.
HTV adds a red PVC jacket around the PE-X dielectric and a tinned copper 22 AWG conductor. Its dielectric and outside diameters increase with the selected DC voltage. Separate moving and fixed bend-radius values are provided for each configuration, so the lead can be matched to the available entry, support and service-loop space.
The AC figures in the HTV table describe production spark-test conditions. They are separate from the DC operating ratings. For continuous operation, specify the operating voltage, duty duration and equipment environment so the appropriate operating-voltage derating can be set. Use the construction tables to match insulation diameter, overall diameter, colour and terminal preparation to the equipment drawing.
Explore the high voltage DC and test cable range for related configurations.
For related flexible silicone-insulated DC wires and chemically inert fluoropolymer HV hook-up leads, compare: High Voltage Silicone Wire, 3–60 kV DC (for extra-flexible -60 °C to +200 °C silicone-insulated 3–60 kV DC leads); FEP High Voltage Wire, 18–30 kV DC (for thin-wall 18–30 kV DC FEP fluoropolymer wires resistant to transformer oils, solvents, and vacuum outgassing). Confirm continuous operating temperature, minimum static bend radius, and rated DC voltage before ordering.
Construction
The illustration represents the HTV-50-22-2 reference configuration: one small tinned copper conductor, a concentric PE-X dielectric and a red PVC jacket. HXW is a separate single-insulated construction with no outer jacket.

| Component | Material and construction |
|---|---|
| HXW conductor | 24 AWG stranded tinned annealed copper, 19/36 AWG stranding, nominal conductor diameter 0.64 mm. |
| HXW insulation | Irradiation-cross-linked polyethylene (XLPE); one insulation layer with no separate jacket or metallic screen. |
| HTV conductor | 22 AWG tinned copper, 7 × AWG30, bunched and re-tinned; 0.36 mm², nominal conductor diameter 0.76 mm. |
| HTV dielectric | Concentric PE-X insulation; dielectric diameter is 2.8, 3.2 or 4.6 mm for the 20, 30 or 50 kV DC configurations respectively. |
| HTV jacket | Red PVC, approximately RAL 3000. Overall diameter is 4.7, 5.0 or 6.6 mm respectively. |
| Shielding | Unshielded construction. No metallic braid, foil screen or armour. |
Applications
Use these single-conductor designs for internal high voltage equipment wiring, with the insulation system and routing selected for the equipment and operating duty.

- Internal DC high voltage connections in power supplies, test equipment and electronic equipment.
- Compact internal leads where the 24 AWG HXW construction and small outside diameter suit the available routing space.
- Jacketed internal leads where HTV PE-X dielectric dimensions and the additional PVC jacket match the equipment entry and support arrangement.
- Observe the configuration-specific bend radius and provide strain relief at terminations. Moving bend-radius data do not specify a continuous-flex service life.
- Coordinate DC voltage, continuous-operation duty, temperature and termination clearances with the equipment design.
For custom high-voltage silicone cable assemblies and braided-shield PE-X coaxial leads, review these engineering pages: High Voltage Silicone Cable Manufacturer (for custom elastomer HV leads when tight routing radii or extreme ambient temperatures exceed XLPE limits); High Voltage Coaxial Cable — PE-X, FEP and PE Configurations (for screened PE-X, FEP, and PE coaxial cables where grounded outer shielding and controlled impedance are required). Verify potting-compound adhesion, creepage distance, and flame rating (UL 3239 / UL 3173 style) during layout.
Specifications
| Parameter | Value |
|---|---|
| Rated voltage reference classes, DC | HXW: 3, 6 and 10 kV DC; HTV: 20, 30 and 50 kV DC. |
| Conductor size | HXW: 24 AWG; HTV: 22 AWG / 0.36 mm². |
| Insulation system | HXW: single XLPE insulation; HTV: PE-X dielectric with a separate PVC jacket. |
| Temperature | HXW: maximum +105°C; HTV: −15°C to +105°C. |
| Screen construction | Unshielded single conductor. |
| HXW insulation resistance | Minimum 1 GΩ·km at 20°C. |
| Conductor resistance at 20°C | HXW: ≤83.3 Ω/km; HTV: ≤58 Ω/km. |
| Model reference and conductor size | DC rating (kV) | Stranding (No./AWG) | Conductor diameter (mm) | Max. resistance at 20°C (Ω/km) | Outside diameter (mm) |
|---|---|---|---|---|---|
| HXW-03-24-* 24 AWG | 3 | 19/36 | 0.64 | 83.3 | 1.60 |
| HXW-06-24-* 24 AWG | 6 | 19/36 | 0.64 | 83.3 | 1.74 |
| HXW-10-24-* 24 AWG | 10 | 19/36 | 0.64 | 83.3 | 1.90 |
| Model reference and conductor size | DC rating (kV) | PE-X diameter (mm) | Overall diameter (mm) | AC spark test (kV) | Min. moving bend radius (mm) | Min. fixed bend radius (mm) | Approx. mass (kg/m) |
|---|---|---|---|---|---|---|---|
| HTV-20-22-2 22 AWG / 0.36 mm² | 20 | 2.8 ±0.1 | 4.7 ±0.2 | 15 | 48 | 24 | 0.027 |
| HTV-30-22-2 22 AWG / 0.36 mm² | 30 | 3.2 ±0.15 | 5.0 ±0.2 | 20 | 50 | 25 | 0.028 |
| HTV-50-22-2 22 AWG / 0.36 mm² | 50 | 4.6 ±0.2 | 6.6 ±0.2 | 30 | 66 | 33 | 0.043 |
| Suffix replacing * | Insulation colour |
|---|---|
| 6 | Blue |
| 8 | Grey |
| 9 | White |
| 12 | Pink |
| Reference configuration | Oil-test reference and condition | Flame-test reference |
|---|---|---|
| HTV-20-22-2 | DIN EN 60811-2-1, 168 h at ≤80°C | UL 2556 horizontal flame test |
| HTV-30-22-2 | UL 1581 Table 50.182 at ≤60°C | UL 2556 horizontal flame test |
| HTV-50-22-2 | UL 1581 Table 50.182 at ≤60°C | UL 2556 horizontal flame test |
Model references identify the compared constructions. Include the required DC rating, conductor size, colour and length with the enquiry.
XLPE and PE-X both denote cross-linked polyethylene. The HXW and HTV insulation systems remain separate configurations, with their own dimensions and test references.
The HTV AC spark-test values are production-test conditions, not AC working-voltage ratings. Set the continuous-duty operating voltage with the equipment design and the required derating.
The * in an HXW model reference is the insulation colour suffix. HTV references listed here use a red jacket, approximately RAL 3000.
Standards
| Standard or specification | Application |
|---|---|
| UL 758 — Appliance Wiring Material | Internal equipment-wiring reference for the HXW and HTV constructions. Select the exact configuration and equipment application together. |
| UL VW-1 flame-test reference | HXW XLPE insulation construction. |
| UL 2556 horizontal flame-test reference | HTV PE-X/PVC construction, as listed by model. |
| DIN EN 60811-2-1 / UL 1581 Table 50.182 | HTV oil-test references; the method and exposure condition differ between the 20 kV and 30/50 kV configurations. |
| HTV production spark-test reference | 15, 20 or 30 kV AC for the 20, 30 or 50 kV DC configurations respectively. |
| RoHS material specification | Material-compliance reference for the listed HXW and HTV constructions. |
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
High Voltage Silicone Wire, 3–60 kV DC
A related cable option for a different application or duty profile.
View productFEP High Voltage Wire, 18–30 kV DC
A related cable option for a different application or duty profile.
View productHigh Voltage Coaxial Cable — PE-X, FEP and PE Configurations
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.