Submersible Pump Cables TEBAOFLEX

S07BB-F / S1BB-F Round Drinking Water Pump Cable

S07BB-F and S1BB-F are round flexible drinking-water pump cables with Class 5 plain copper conductors, EPR core insulation and a blue EM6-type EPR sheath.

  • S07BB-F: 450/750 V; S1BB-F: 0.6/1 kV
  • EPR core insulation and a blue EM6-type EPR sheath
  • Class 5 plain copper conductors
  • 90 °C maximum conductor temperature
  • Round geometry; separate 450/750 V and 0.6/1 kV tables
Product information
Brand
TEBAOFLEX
Product overview

S07BB-F and S1BB-F are round flexible drinking-water pump cables with Class 5 plain copper conductors, EPR core insulation and a blue EM6-type EPR sheath. S07BB-F is rated 450/750 V; S1BB-F is rated 0.6/1 kV. This page keeps the two model ranges in separate configuration tables.

Round geometry suits circular pump entries, glands and supported routes through a well or plant. The listed range includes single-core, phase-only and protective-earth configurations. G identifies a green/yellow protective conductor; × identifies a configuration without that conductor. Match the selected arrangement to the motor wiring diagram, including any separate control or monitoring circuits.

Use both outside-diameter limits when selecting an entry seal. Fixed and moving bend radii, mass and current data appear beside each configuration. Air and fully immersed current ratings retain their separate 30 °C reference conditions, helping the designer identify the route section that controls conductor sizing.

Water-supply installations require coordinated selection of the cable, submerged joints and all wetted accessories. Provide the drinking-water contact requirements, water composition, motor duty, installed length and sealing drawings with the enquiry. Water depth and water-temperature limits are confirmed for the project after enquiry. For a narrow flat entry, compare the corresponding S07BBH2-F or S1BBH2-F construction; choose the geometry around the actual available space and support arrangement.

Construction

Construction

Cable layers are listed from the conductor to the outer sheath.

S1BB-F round four-core cross-section with fine copper strands and blue EPR sheath
Representative S1BB-F 4G25 construction; other configurations are listed in the specification tables.
Cable layers
LayerConstruction
ConductorPlain fine-stranded copper, Class 5 to IEC 60228.
InsulationEPR rubber.
Core arrangementRound single-core, power or multicore assembly according to the configuration table. G identifies a green/yellow protective conductor; x identifies no protective conductor.
Outer sheathBlue water-resistant EM6-type EPR rubber. No metallic braid or armour.
Applications

Applications

Use this construction for drinking-water submersible pumps, borehole motors and booster plants. Match the cable to the actual equipment, route and water medium before selecting the final configuration.

Blue pump cable supported on a fixed post between a closed control cabinet and a sealed water-supply wellhead
Application illustration: supported motor-cable route between a closed control cabinet and a sealed water-supply wellhead.
  • Select the model and voltage first; S07BB-F and S1BB-F have separate dimensions and test conditions.
  • Match single-core, phase-only and G configurations to the motor wiring diagram.
  • Check the whole water-contact route, joints and entry seals against the project drinking-water requirements.

Use a supported route under medium mechanical stress. Exclude explosion-hazard locations and water containing more than 0.5 mg/l chlorine for this construction. Review other aggressive water compositions individually.

Round cable selection

Round cable selection
Selection pointDesign input
Voltage familySelect S07BB-F or S1BB-F before matching the dimensions and voltage-test condition.
Motor connectionCheck phase, neutral and PE requirements against the G or × designation.
Circular entryUse both finished OD limits and the seal supplier’s permissible compression range.
Contact systemSpecify the drinking-water requirements for all wetted cable sections, joints and accessories.

Related selection resources

Specifications

Specifications

Electrical and operating parameters
ParameterValue
Rated voltage U₀/US07BB-F: 450/750 V; S1BB-F: 0.6/1 kV
ConductorPlain flexible copper, Class 5
Insulation and sheathEPR core insulation and a blue EM6-type EPR sheath
Maximum conductor temperature90 °C
Ambient / handling conditions−50 °C fixed and flexible reference
Water depth and water temperatureProject operating conditions reviewed with the enquiry.
Short-circuit conductor temperature250 °C
Maximum permissible operating voltage ACS07 series: 0.476/0.825 kV; S1 series: 0.7/1.2 kV
Maximum permissible operating voltage DCS07 series: 0.619/1.238 kV; S1 series: 0.9/1.8 kV

Air ratings assume continuous DC or 50–60 Hz AC at 30 °C with the stated loaded-core arrangement. Water ratings assume complete immersion at 30 °C. Keep these installation conditions with the current values.

S07BB-F dimensions and electrical data

S07BB-F configuration table
Configuration (mm²)OD minimum (mm)OD maximum (mm)Minimum fixed bend radius (mm)Minimum moving bend radius (mm)Approximate mass (kg/km)Maximum tensile force (N)Current in air at 30 °C (A)Current fully immersed at 30 °C (A)Conductor short-circuit current, 1 s (kA)
S07BB-F 1 × 1.55.76.41919502333400.21
S07BB-F 1 × 68.28.927361169076910.86
S07BB-F 1 × 109.81133441731501061271.43
S07BB-F 1 × 1611.512.751642652401421702.29
S07BB-F 1 × 2513.214.458723753751882253.56
S07BB-F 1 × 3514.916.466824855252322785
S07BB-F 1 × 501718.574936707502893477.15
S07BB-F 1 × 7018.620.180101859105035842910
S07BB-F 1 × 9521.923.4941171141142543151713.59
S07BB-F 1 × 12024.125.61021281436180050460517.16
S07BB-F 1 × 15026.428.61141431777225057869421.45
S07BB-F 1 × 24031.5341361702900360078394034.32
S07BB-F 1 × 30034.537.515018835004500906108742.9
S07BB-F 1 × 40038.541.9168210455060001045125457.2
S07BB-F 1G5017.518.574937007502893477.15
S07BB-F 1G70192080100950105035842910
S07BB-F 1G9521.923.4941171200142543151713.59
S07BB-F 1G12024.3261041301500180050460517.16
S07BB-F 3 × 1.59.410.431421306824290.21
S07BB-F 3 × 2.510.912.5506318711332380.36
S07BB-F 3 × 412.514.1567125218043520.57
S07BB-F 3 × 61415.6627833427056670.86
S07BB-F 3 × 1019.821.88710966545078931.43
S07BB-F 3 × 1623.625.61021289687201041252.29
S07BB-F 3 × 252730120150135211251381653.56
S07BB-F 3 × 3530.533.5134168170715751712055
S07BB-F 3 × 5035.638.6154193242122502132557.15
S07BB-F 3 × 7039.742.71712143289315026331610
S07BB-F 3 × 9545.648.61942434300427531738013.59
S07BB-F 3 × 12048.251.22052565300540037144517.16
S07BB-F 3G1.59.410.431421376824290.21
S07BB-F 3G2.510.912.5506319711332380.36
S07BB-F 3G412.514.1567126918043520.57
S07BB-F 4G1.510.111.735471579024290.21
S07BB-F 4G2.51213.6546823515032380.36
S07BB-F 4G414.215.8637933524043520.57
S07BB-F 4G615.517.5708842836056670.86
S07BB-F 4G1020.922.99211574660078931.43
S07BB-F 4G1624.527.511013811249601041252.29
S07BB-F 4G2529.932.9132165166815001381653.56
S07BB-F 4G3533.636.6146183218421001712055
S07BB-F 4G5039.542.5170213303430002132557.15
S07BB-F 4G7043.546.51862333975420026331610
S07BB-F 4G9550.654.62182735529570031738013.59
S07BB-F 4G12055.159.12362966771720037144517.16
S07BB-F 4G15059.663.62543188250900042551021.45
S07BB-F 5 × 2.513.414.4587231018832380.36
S07BB-F 7G1.515.216.7678435315824290.21
S07BB-F 7G2.517.218.9769549426332380.36
S07BB-F 7G420.722.79111471442043520.57

S1BB-F dimensions and electrical data

S1BB-F configuration table
Configuration (mm²)OD minimum (mm)OD maximum (mm)Minimum fixed bend radius (mm)Minimum moving bend radius (mm)Approximate mass (kg/km)Maximum tensile force (N)Current in air at 30 °C (A)Current fully immersed at 30 °C (A)Conductor short-circuit current, 1 s (kA)
S1BB-F 1 × 1.55.86.62020532333400.21
S1BB-F 1 × 2.56.372121653843520.36
S1BB-F 1 × 46.77.52323826059700.57
S1BB-F 1 × 67.2824321039076910.86
S1BB-F 1 × 108.39.127361521501061271.43
S1BB-F 1 × 169.110.130402122401421702.29
S1BB-F 1 × 2510.812.450623163751882253.58
S1BB-F 1 × 3512.313.956704225252322785.01
S1BB-F 1 × 5014.115.763795797502893477.15
S1BB-F 1 × 7016.318.37392808105035842910.01
S1BB-F 1 × 9518.820.3811021026142543151713.59
S1BB-F 1 × 12020.922.9921151317180050460517.16
S1BB-F 1 × 15023.225.21011261629225057869421.45
S1BB-F 1 × 1852628.31131421986277566079226.46
S1BB-F 1 × 24028.931.21251562553360078394034.32
S1BB-F 1 × 30032.134.413817231574500906108742.9
S1BB-F 1 × 40036.338.6154193409460001045125457.2
S1BB-F 1 × 50040.442.7171214516875001203144371.5
S1BB-F 2 × 1892736903019230.14
S1BB-F 2 × 1.58.69.629381064524290.21
S1BB-F 2 × 2.59.410.431421357532380.36
S1BB-F 2 × 410.211.8354717512043520.57
S1BB-F 2 × 611.212.8516423018056670.86
S1BB-F 2 × 101517688539930078931.43
S1BB-F 2 × 1617.619.678985704801041252.29
S1BB-F 2 × 2521.623.6941188507501381653.58
S1BB-F 3G1.59.110.130401256824290.21
S1BB-F 3G2.59.611.2344516211332380.36
S1BB-F 3G410.612.2496121618043520.57
S1BB-F 3 × 18.49.529381044519230.14
S1BB-F 3 × 1.59.110.130401256824290.21
S1BB-F 3 × 2.59.611.2344516211332380.36
S1BB-F 3 × 410.612.2496121618043520.57
S1BB-F 3 × 612.113.7556929227056670.86
S1BB-F 3 × 1016.318.3739251445078931.43
S1BB-F 3 × 1619.121.1841067407201041252.29
S1BB-F 3 × 2523.125.1100126109411251381653.58
S1BB-F 3 × 3525.628.6114143145915751712055.01
S1BB-F 3 × 5029.932.9132165201822502132557.15
S1BB-F 3 × 7035.438.41541922808315026331610.01
S1BB-F 3 × 9539421682103547427531738013.59
S1BB-F 3 × 12044.447.41902374542540037144517.16
S1BB-F 3 × 15049532122655627675042551021.45
S1BB-F 3 × 18554.258.22332916819832548558226.46
S1BB-F 3 × 24061.465.426232786451080057669134.32
S1BB-F 3 × 30068.472.9292365110811350066680042.9
S1BB-F 4G19.110.130401236019230.14
S1BB-F 4G1.59.511.133441489024290.21
S1BB-F 4G2.510.512.1486120115032380.36
S1BB-F 4G411.813.4546727624043520.57
S1BB-F 4G613.615.2617637836056670.86
S1BB-F 4G1017.819.8799964660078931.43
S1BB-F 4G1620.922.9921159349601041252.29
S1BB-F 4G2525.328.3113142141815001381653.58
S1BB-F 4G3528.331.3125157187721001712055.01
S1BB-F 4G5033.236.2145181261330002132557.15
S1BB-F 4G7038.741.71672093638420026331610.01
S1BB-F 4G9543.747.71912394643570031738013.59
S1BB-F 4G12048.752.72112645833720037144517.16
S1BB-F 4G15054.558.52342937222900042551021.45
S1BB-F 4G18560.664.625832388301110048558226.46
S1BB-F 4G24068.272.2289361114571440057669134.32
S1BB-F 4G3007781324405143681800066680042.9
Standards

Standards

Technical references and test conditions for the specified construction.

Standards and test references
ItemReference
ConductorIEC 60228, Class 5
AC voltage testS07BB-F: 2.5 kV AC / 15 minutes; S1BB-F: 3 kV AC / 15 minutes
Construction / use referenceEN 50525-2-21 and the specified construction.
Core identificationDIN VDE 0293-308; numbered control cores where applicable.

For conductor classes and nominal metric cross-sections, see the IEC 60228 standard scope.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.