VSCCB 0.6/1 kV Screened Submersible Pump Cable

VSCCB is a 0.6/1 kV screened rubber cable for wastewater pumps and frequency-converter-controlled AC drives. It combines EPR insulation and sheath compounds with an overall tinned-copper braid.

  • Three-core 6, 10 and 16 mm² pump-connection reference dimensions.
  • Class 5 flexible copper; tinned up to 6 mm², plain above 6 mm².
  • 90 °C maximum conductor temperature.
  • Separate fixed-route, flexible-route and entry bend references.

Send the configuration, motor-drive details, installed length and entry drawing for a technical quotation.

Product information
Brand
TEBAOFLEX
Product overview

VSCCB for Screened Wastewater Pump Connections

VSCCB is a 0.6/1 kV screened rubber cable for wastewater pumps and frequency-converter-controlled AC drives. EPR-insulated flexible copper phase conductors, a tinned-copper braid and an EPR outer sheath provide a defined screening path around the power circuit.

The pump-connection dimension table covers three-core 6, 10 and 16 mm² configurations. Match the complete diameter range to the seal or gland, then allow room for screen preparation and strain relief. The illustrated three-core construction represents the family material arrangement; the finished cable and entry dimensions belong together in the connection design.

Effective EMC installation requires broad screen contact at both ends, coordinated with the drive, motor and enclosure. Specify the protective-earth path with the equipment design as well as the screen connection. Cable supports should carry the installed lead without transferring pump weight to the entry; use the pump’s designated lifting system for handling.

  • Choose the conductor section from motor current, drive output and route length.
  • Use the separate fixed and flexible bend factors for the intended route.
  • Coordinate the pump-entry bend reference with the seal and termination drawing.

Include wastewater composition, cleaning chemicals, installed length and the controller details with the enquiry. Immersion depth and the permitted maximum water temperature are confirmed for the specified project.

For VSCCB project selection, explore the submersible pump cable range; for VSCCB screen connections, consult the VFD cable guide.

Construction

Construction

The representative VSCCB three-core arrangement has three equal phase cores inside an EPR sheath system and an overall metallic braid. Select the phase section and connection details together.

VSCCB three-core cable cross-section with three equal phase cores in triangular arrangement, EPR sheath system and overall copper braid
Representative three-core EPR and braid construction. Pump-connection reference dimensions are listed in Specifications.
VSCCB screened pump cable construction
ElementConstruction
Phase conductorsFine-stranded copper, Class 5; tinned up to and including 6 mm², plain above 6 mm².
Core insulationEPR rubber compound.
Core identificationDIN EN 50525-1; the illustrated three-core phase arrangement uses brown, black and grey.
Inner sheathEPR rubber in the illustrated material arrangement.
ScreenOverall tinned-copper braid between the inner and outer sheath.
Outer sheathEPR rubber compound.
Protective connectionSpecify the protective-earth path and the screen termination with the equipment design.
Applications

Applications

Screened power connections for wastewater pumps and AC motors operated from frequency converters, with coordinated EMC bonding, sealing and mechanical support.

Screened pump cable on an independently supported route between a wastewater pump and the drive cabinet
Application illustration: independently supported cable route with a separate pump lifting system.
VSCCB installation selection checkpoints
Selection pointRequirement
Screen bondingProvide broad, effective braid contact to ground at both connection ends.
Protective-earth designSpecify the protective-earth path with the motor and drive connection; coordinate it with the screen termination.
Pump entryChoose the seal from the complete diameter range and allow room for braid preparation and strain relief.
Cable routeUse the fixed or flexible bending factor for the intended route and provide independent supports.
Entry bend referenceUse the pump-entry radius reference with the sealing and termination drawing; fully flexible routing uses the separate flexible factor.
Circuit selectionSupply motor current, drive output, installed length and installation conditions.
Water chemistry and dutyProvide wastewater composition, immersion depth and water-temperature conditions with the enquiry.
Specifications

Specifications

Keep the cable-family limits and the pump-entry reference dimensions with their stated installation conditions.

VSCCB 0.6/1 kV cable-family technical profile
ParameterValue or condition
Rated voltage U₀/U0.6/1 kV
Connection dimensionsThree-core 6, 10 and 16 mm² references
ScreenOverall tinned-copper braid
Insulation and sheathEPR core insulation and sheath system
ConductorClass 5 flexible copper; tinned ≤6 mm², plain >6 mm²
Maximum AC operating voltage0.7/1.2 kV
Maximum DC operating voltage0.9/1.8 kV
AC test voltage / duration3 kV / 15 minutes, main cores
Maximum conductor temperature90 °C
Short-circuit conductor temperature250 °C
Minimum ambient temperature, fixed−50 °C
Minimum ambient temperature, flexible−50 °C
Maximum conductor tensile stress15 N/mm²
Minimum bend radius, fixed4 × maximum overall diameter
Minimum bend radius, flexible6 × maximum overall diameter
Installation profileRound screened cable for medium mechanical stress
Family range1–12 cores; cross-sections up to 240 mm²

Three-Core Pump-Connection Dimensions

Use these entry references with the pump sealing and termination drawing. The entry radius describes the documented installation arrangement; fully flexible routing uses the separate 6 × maximum-OD requirement.

VSCCB three-core pump-connection reference dimensions
Reference configuration (mm²)Minimum OD (mm)Maximum OD (mm)Pump-entry bend reference (mm)
VSCCB 3×613.615.276
VSCCB 3×1017.819.899
VSCCB 3×1620.922.9115
Standards

Standards

VSCCB construction and test references
ReferenceApplication
EN 50525-2-21Construction reference: based on EN 50525-2-21.
DIN EN 60228Class 5 conductor construction.
DIN EN 50525-1Core identification reference.
DIN EN 60332-1-2Single-cable flame-performance reference.
DIN EN 60811-404Oil-resistance test reference.
DIN EN 50565-2General installation guidance.
AC voltage testMain cores: 3 kV for 15 minutes.

For conductor classes, see the IEC 60228 standard scope.

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.