MINING & TUNNELING CABLES TEBAOFLEX

CSA Type SHD-BGC, SHD-R and SHD-SP Shielded Mining Cable

Canadian shielded portable mining power cable engineered to CSA C22.2 No. 96 from 2 kV to 35 kV in Type SHD-BGC (braided ground-check over pilot), Type SHD-R (anti-torsion reeling construction) and Type SHD-SP / SHD-GC-SP (semi-conductive polymeric phase screen). Built for open-pit electric rope shovels, draglines, mobile stackers and cold-climate potash or hard-rock mines down to -40 C.

Product information
SKU
CSA-SHD-BGC-SHD-R
Brand
TEBAOFLEX
Product overview

Canadian open-pit oil-sands shovels, walking draglines, mobile crushers and underground hard-rock or potash mines specify CSA C22.2 No. 96 shielded portable power cables tailored to distinct ground-check and mechanical reeling duties. Whereas standard US ICEA Type SHD-GC uses an unshielded insulated ground-check core, the Canadian CSA C22.2 No. 96 family defines Type SHD-BGC, Type SHD-R and Type SHD-SP / Type SHD-GC-SP across 2 kV, 5 kV, 8 kV, 15 kV, 25 kV and 35 kV voltage ratings.

Type SHD-BGC incorporates a braided tinned-copper ground-check conductor (BGC) concentrically applied over an insulated pilot core so rock-crush impact immediately triggers the ground-fault monitor before phase-to-ground contact occurs. Type SHD-R adds an open-weave high-tenacity synthetic anti-torsion braid locked between dual thermoset CPE jackets for high-tension monospiral and level-wind cable reels on stacker-reclaimers and electric shovels.

Type SHD-SP and Type SHD-GC-SP replace metallic phase braid shields with a heavy-duty semi-conductive polymeric phase screen over the 90 C EPR insulation, eliminating broken metallic shield strands that can puncture insulation during severe flexing and simplifying field splicing. All variants are engineered for -40 C cold-bend/cold-impact performance and FT1/FT4 flame retardance.

Explore the mining and tunneling cable range for related configurations.

Construction

CSA Type SHD-BGC, SHD-R and SHD-SP Shielded Mining Cable Construction & Layer Breakdown

The representative horizontal sample illustrates the CSA C22.2 No. 96 Type SHD-BGC 5 kV construction, showing three flexible rope-lay tinned copper power cores with triple-extruded EPR dielectric and tinned-copper/textile composite phase shields, two uninsulated interstitial grounding conductors, one yellow EPR pilot core with a concentric braided tinned-copper ground-check shield (BGC) and a reinforced two-layer -40 C thermoset CPE jacket.

Flat 2D cross-section diagram of CSA Type SHD-BGC and SHD-R mining cable showing 3 screened power cores, 2 uninsulated interstitial grounds and 1 braided ground-check pilot core
Cross-section of CSA Type SHD-BGC / SHD-R / SHD-SP mining cable showing 3 EPR-insulated phase cores with phase shields, 2 tinned copper grounding conductors and 1 braided ground-check pilot.
CSA Type SHD-BGC, SHD-R and SHD-SP Shielded Mining Cable construction
ComponentMaterial and construction
Power Conductors (3 x Rope-Lay Tinned Copper)Annealed tinned copper rope-lay stranded conductors (6 AWG to 500 kcmil) engineered to CSA C22.2 No. 96 and ASTM B33 for high flex life.
Conductor Screen & 90 C EPR InsulationExtruded semi-conducting thermoset conductor screen and ozone-/discharge-resistant 90 C EPR insulation sized to 2 kV, 5 kV, 8 kV, 15 kV, 25 kV or 35 kV wall schedules.
Phase Shielding (Metallic Braid or SP Polymeric)Tinned-copper and nylon composite braid over semi-conducting insulation screen on SHD-BGC and SHD-R; heavy semi-conductive elastomeric screen on SHD-SP / SHD-GC-SP.
Symmetrical Grounding ConductorsTwo flexible stranded tinned copper grounding conductors laid in two outer interstices in intimate contact with the phase screens.
Braided Ground-Check / Pilot Assembly (BGC / GC)SHD-BGC uses a concentric tinned-copper braid shield over an insulated pilot core; SHD-R and SHD-GC-SP use a high-strength yellow EPR-insulated ground-check core.
Inner Bedding & Anti-Torsion BraidExtruded black thermoset elastomeric inner jacket with open-weave synthetic reinforcing braid (heavy anti-torsion weave on Type SHD-R).
Arctic -40 C FT1/FT4 Outer JacketExtra-heavy-duty thermoset chlorinated polyethylene (CPE) or polychloroprene (PCP) outer jacket rated for -40 C cold impact, oil, UV and FT1/FT4 flame tests.

CSA Type SHD-BGC, SHD-R and SHD-SP Designation Breakdown (CSA C22.2 No. 96)

  • CSA C22.2 No. 96: Canadian Standards Association standard for portable power cables including arctic -40 °C cold-impact and FT1/FT4 flame compliance
  • SHD: Shielded heavy-duty portable trailing cable with individual metallic phase shields over 90 °C EPR power conductors
  • BGC (SHD-BGC): Braided Ground-Check — concentric tinned-copper braid shield applied directly over the insulated yellow ground-check pilot conductor (2 kV to 15 kV)
  • R (SHD-R): Reeling service — anti-torsion synthetic reinforcing braid between dual CPE jackets plus flexible metallic braid phase shields for monospiral/cylindrical drums (5 kV to 35 kV)
  • SP / GC-SP (SHD-SP): Semi-Conductive Polymeric phase screen — non-metallic flexible stress-control screen eliminating metallic braid strand fatigue on tight-bend equipment (5 kV to 15 kV)
Applications

CSA Type SHD-BGC, SHD-R and SHD-SP Trailing & Reeling Mining Applications

Select CSA Type SHD-BGC, Type SHD-R or Type SHD-SP / SHD-GC-SP according to provincial Canadian mine code requirements, reeling drum tension and field-splicing practices.

CSA Type SHD-BGC medium-voltage shielded trailing cable feeding an electric rope shovel on a snow-dusted Canadian open-pit mine bench
CSA Type SHD-BGC and SHD-R medium-voltage shielded trailing and reeling cables operating in sub-zero Canadian open-pit electric shovel and underground potash mining service.
  • Electric rope shovels, hydraulic face shovels and walking draglines in Canadian oil sands, open-pit coal, iron-ore and copper mines operating from 5 kV to 35 kV (Type SHD-BGC).
  • Motorized cable-reel shovels, mobile hopper cars, bucket-wheel reclaimers and shiploaders requiring torsion-free drum reeling under CSA C22.2 No. 96 (Type SHD-R).
  • High-flexibility trailing feeders and mobile substations where semi-conductive polymeric phase screens eliminate metallic braid fatigue and speed up field vulcanized splices (Type SHD-SP / SHD-GC-SP).
  • Sub-zero Arctic and boreal open-pit or underground mining distributions requiring -40 C cold-bend and FT1/FT4 flame compliance.

CSA Type SHD-BGC, SHD-R and SHD-SP vs SHD-GC & SHD-CGC Selection Matrix

CSA Type SHD-BGC, SHD-R & SHD-SP vs Standard ICEA Type SHD-GC & SHD-CGC Comparison
Cable TypeStandard & Voltage ClassPilot / Phase Screen ArchitecturePrimary Mining Duty
CSA Type SHD-BGCCSA C22.2 No. 96 (2 kV to 15 kV)Tinned copper braid phase shields + concentric braided copper screen over yellow GC pilotCanadian electric shovels, draglines and mobile substations requiring braided pilot fault detection and -40 °C cold impact
CSA Type SHD-RCSA C22.2 No. 96 (5 kV to 35 kV)Flexible metallic braid phase shields + anti-torsion synthetic braid between dual CPE jacketsVertical/horizontal reeling drums on continuous miners, electric LHDs and mobile stacker-reclaimers
CSA Type SHD-SP / SHD-GC-SPCSA C22.2 No. 96 (5 kV to 15 kV)Flexible semi-conductive polymeric phase screen (no metallic phase braid strand breakage)Tight-bend underground potash miners, shuttle cars and high-flex trailing loops
ICEA Type SHD-GCICEA S-75-381 / NEMA WC 58 (2 kV to 25 kV)Copper tape + braid phase shield with unshielded insulated PP/EPR ground-check pilotGeneral North American open-pit and underground MV trailing feeders without CSA braided-pilot mandate

Specify CSA Type SHD-BGC when Canadian provincial mine codes require a concentrically screened ground-check pilot, SHD-R for tensioned cable reels, or SHD-SP where tight flexing causes metallic braid fatigue.

Related selection resources

CSA Type SHD-BGC, SHD-R and SHD-SP Shielded Mining Cable Engineering FAQ

What is the difference between CSA Type SHD-BGC, SHD-R and SHD-SP?

All three are manufactured to CSA C22.2 No. 96 with 90 °C EPR insulation and -40 °C cold-impact CPE jackets. Type SHD-BGC (2 kV to 15 kV) features a concentric tinned-copper braid shield over the yellow ground-check pilot conductor for fail-safe pilot fault detection. Type SHD-R (5 kV to 35 kV) adds an anti-torsion synthetic reinforcing braid between dual CPE jackets for motorized reeling drums. Type SHD-SP / SHD-GC-SP (5 kV to 15 kV) replaces the metallic phase braid with a flexible semi-conductive polymeric phase screen to eliminate wire-strand fatigue in tight-radius underground flexing.

Why do Canadian mines specify a braided ground-check (BGC) pilot conductor?

In CSA Type SHD-BGC cables, the concentric copper braid over the insulated 8 AWG or 6 AWG pilot core is tied to ground. If rock crushing or mechanical pinch penetrates the pilot insulation before reaching a phase shield, the pilot conductor immediately contacts its concentric ground braid and trips the ground-check monitor relay at the feeder breaker.

Are CSA Type SHD-BGC and SHD-R cables tested for -40 °C arctic operation?

Yes. Every CSA C22.2 No. 96 Type SHD-BGC, SHD-R and SHD-SP cable is compounded and tested for -40 °C cold-bend and -40 °C cold-impact endurance alongside FT1 / FT4 and MSHA flame-retardant performance for year-round Canadian open-pit and underground operations.

What are the minimum order quantity (MOQ) and manufacturing lead time for CSA Type SHD-BGC, SHD-R and SHD-SP?

TEBAOFLEX supplies CSA C22.2 No. 96 Type SHD-BGC, SHD-R and SHD-SP cables from a 50 m minimum order quantity (MOQ) with a manufacturing lead time of 7 to 45 working days, complete with factory AC hi-pot and partial-discharge test reports.

Specifications

CSA Type SHD-BGC, SHD-R and SHD-SP Technical Specifications & Size Schedule (2 kV to 35 kV)

CSA Type SHD-BGC, SHD-R and SHD-SP Key Electrical, Cold-Impact & Mechanical Ratings

  • Standard & Models: CSA C22.2 No. 96 Type SHD-BGC (2–15 kV), Type SHD-R reeling (5–35 kV) and Type SHD-SP / SHD-GC-SP (5–15 kV)
  • Phase & Pilot Screening: 90 °C EPR insulation with tinned copper braid (SHD-BGC/SHD-R), semi-conductive screen (SHD-SP) or braided pilot (BGC)
  • Conductor Range: 3 Class I/K flexible tinned copper phase cores (6 AWG to 500 kcmil; 4 AWG to 2/0 AWG tabulated) + 2 grounds + 1 pilot
  • Arctic & Flame Rating: -40 °C cold-impact / cold-bend tested per CSA C22.2 No. 96 with FT1 / FT4 and MSHA flame-retardant dual CPE jacket
  • Commercial Terms: MOQ 50 m; manufacturing lead time 7 to 45 working days with factory partial-discharge and AC hi-pot test reports
CSA Type SHD-BGC, SHD-R and SHD-SP Shielded Mining Cable technical data
ParameterValue
Design standard referenceEngineered to CSA C22.2 No. 96, ICEA S-75-381 / NEMA WC 58 and CSA FT1 / FT4 flame test schedules
Rated voltage classes2000 V (2 kV), 5000 V (5 kV), 8000 V (8 kV), 15000 V (15 kV), 25000 V (25 kV) and 35000 V (35 kV)
SHD-BGC vs SHD-R vs SHD-SPSHD-BGC: braided ground-check over pilot; SHD-R: anti-torsion reeling jacket; SHD-SP: semi-conductive polymeric phase screen
Operating temperature range-40 C cold-bend/impact to +90 C continuous conductor temperature (250 C short-circuit rating)
Minimum dynamic bend radius6 x O.D. for 2 kV to 5 kV trailing; 8 x O.D. for 8 kV to 35 kV trailing; 10 x O.D. for dynamic drum reeling (SHD-R)
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7 to 45 working days with factory HV and partial-discharge test reports
Selection boundary vs Type G-BGC & US SHD-GCSelect CSA Type SHD-BGC/SHD-R/SHD-SP for 2 kV to 35 kV Canadian phase-shielded service; select CSA Type G-BGC for unshielded 2 kV duty.

CSA C22.2 No. 96 Type SHD-BGC (2 kV to 15 kV) Braided Ground-Check Shielded Mining Cable Schedule

CSA C22.2 No. 96 Type SHD-BGC (2 kV to 15 kV) Braided Ground-Check Shielded Mining Cable — Nominal Dimensions & Ampacity
Cable Designation & Core LayoutVoltage RatingPower Core SizeGrounding CoresGround-Check (BGC)Nominal EPR Wall (mm)Nominal Overall O.D. (mm)Approx. Net Mass (kg/km)Ampacity at 40 °C Ambient (A)Next step
SHD-BGC 2kV 3x4 AWG + 2x8 + 1x8 BGC2 kV4 AWG2x8 AWG8 AWG BGC2.838.42240122Request this size
SHD-BGC 2kV 3x2 AWG + 2x6 + 1x8 BGC2 kV2 AWG2x6 AWG8 AWG BGC2.842.22890159Request this size
SHD-BGC 5kV 3x2 AWG + 2x6 + 1x8 BGC5 kV2 AWG2x6 AWG8 AWG BGC3.849.33560164Request this size
SHD-BGC 5kV 3x1/0 AWG + 2x4 + 1x8 BGC5 kV1/0 AWG2x4 AWG8 AWG BGC3.854.64680211Request this size
SHD-BGC 5kV 3x2/0 AWG + 2x3 + 1x8 BGC5 kV2/0 AWG2x3 AWG8 AWG BGC3.858.25420243Request this size
SHD-BGC 5kV 3x4/0 AWG + 2x1 + 1x8 BGC5 kV4/0 AWG2x1 AWG8 AWG BGC3.865.07290321Request this size
SHD-BGC 8kV 3x1/0 AWG + 2x4 + 1x8 BGC8 kV1/0 AWG2x4 AWG8 AWG BGC4.458.45120215Request this size
SHD-BGC 8kV 3x2/0 AWG + 2x3 + 1x8 BGC8 kV2/0 AWG2x3 AWG8 AWG BGC4.461.75890248Request this size
SHD-BGC 15kV 3x1/0 AWG + 2x4 + 1x8 BGC15 kV1/0 AWG2x4 AWG8 AWG BGC5.365.56140218Request this size
SHD-BGC 15kV 3x2/0 AWG + 2x3 + 1x8 BGC15 kV2/0 AWG2x3 AWG8 AWG BGC5.368.86950251Request this size

CSA C22.2 No. 96 Type SHD-R (Reeling) & SHD-GC-SP (Semi-Conductive Screen) 5 kV to 35 kV Schedule

CSA C22.2 No. 96 Type SHD-R (Reeling, 5–35 kV) & Type SHD-SP / SHD-GC-SP (Semi-Conductive Screen) — Nominal Dimensions & Ampacity
Cable Designation & Core LayoutVoltage RatingPower Core SizePhase Shield & Jacket ArchitectureNominal EPR Wall (mm)Nominal Overall O.D. (mm)Approx. Net Mass (kg/km)Ampacity at 40 °C Ambient (A)Next step
SHD-R 5kV 3x2 AWG + 2x6 + 1x8 GC5 kV2 AWGMetallic Braid + Anti-Torsion3.850.83740164Request this size
SHD-R 8kV 3x1/0 AWG + 2x4 + 1x8 GC8 kV1/0 AWGMetallic Braid + Anti-Torsion4.459.85320215Request this size
SHD-R 15kV 3x2/0 AWG + 2x3 + 1x8 GC15 kV2/0 AWGMetallic Braid + Anti-Torsion5.370.47210251Request this size
SHD-R 25kV 3x1/0 AWG + 2x4 + 1x8 GC25 kV1/0 AWGMetallic Braid + Anti-Torsion7.578.28180224Request this size
SHD-R 35kV 3x1/0 AWG + 2x4 + 1x8 GC35 kV1/0 AWGMetallic Braid + Anti-Torsion9.889.610450228Request this size
SHD-SP 5kV 3x2/0 AWG + 2x3 + 1x8 GC5 kV2/0 AWGSemi-Conductive Polymeric Screen3.856.45120243Request this size
SHD-GC-SP 8kV 3x2/0 AWG + 2x3 + 1x8 GC8 kV2/0 AWGSemi-Conductive Polymeric Screen4.460.25580248Request this size
SHD-GC-SP 15kV 3x2/0 AWG + 2x3 + 1x8 GC15 kV2/0 AWGSemi-Conductive Polymeric Screen5.367.16610251Request this size

Ampacities are based on a single cable in free air at 40 C ambient and 90 C conductor temperature; apply reeling-drum layer derating factors for Type SHD-R.

Specify exact CSA designation (SHD-BGC, SHD-R, SHD-SP or SHD-GC-SP), voltage class (2 kV to 35 kV) and outer sheath colour (black, yellow or orange) on tender inquiries.

ASCII part references for BOM and ERP entry: SHD-BGC 2kV 3x4 AWG + 2x8 + 1x8 BGC, SHD-BGC 2kV 3x2 AWG + 2x6 + 1x8 BGC, SHD-BGC 5kV 3x2 AWG + 2x6 + 1x8 BGC, SHD-BGC 5kV 3x1/0 AWG + 2x4 + 1x8 BGC, SHD-BGC 5kV 3x2/0 AWG + 2x3 + 1x8 BGC, SHD-BGC 5kV 3x4/0 AWG + 2x1 + 1x8 BGC, SHD-BGC 8kV 3x1/0 AWG + 2x4 + 1x8 BGC, SHD-BGC 8kV 3x2/0 AWG + 2x3 + 1x8 BGC, SHD-BGC 15kV 3x1/0 AWG + 2x4 + 1x8 BGC, SHD-BGC 15kV 3x2/0 AWG + 2x3 + 1x8 BGC, SHD-R 5kV 3x2 AWG + 2x6 + 1x8 GC, SHD-R 8kV 3x1/0 AWG + 2x4 + 1x8 GC, SHD-R 15kV 3x2/0 AWG + 2x3 + 1x8 GC, SHD-R 25kV 3x1/0 AWG + 2x4 + 1x8 GC, SHD-R 35kV 3x1/0 AWG + 2x4 + 1x8 GC, SHD-SP 5kV 3x2/0 AWG + 2x3 + 1x8 GC, SHD-GC-SP 8kV 3x2/0 AWG + 2x3 + 1x8 GC, SHD-GC-SP 15kV 3x2/0 AWG + 2x3 + 1x8 GC.

Standards

CSA Type SHD-BGC, SHD-R and SHD-SP Applicable Standards & Related Mining Cables

CSA Type SHD-BGC, SHD-R and SHD-SP Shielded Mining Cable standards and test references
Standard or specificationApplication
CSA C22.2 No. 96Portable power cables — Canadian construction, voltage endurance, -40 C cold impact and FT1/FT4 flame test standard for SHD-BGC, SHD-R and SHD-SP.
ICEA S-75-381 / NEMA WC 58Portable and power feeder cables for use in mines and similar applications (dimensional and electrical cross-reference).
ASTM B33 & ASTM B172Tinned soft or annealed copper wire and rope-lay stranded copper conductors for portable power cables.
CSA C22.2 No. 0.3Test methods for electrical wires and cables including -40 C cold bend, cold impact and vertical flame tests.

Certifications and document support

TEBAOFLEX company certificates and quality system documentation

NEMA — WC 58 / ICEA S-75-381 Portable and Feeder Mining Cable Standard

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.