MINING & TUNNELING CABLES TEBAOFLEX

MVFP and MYPTJ-JS Metallic-Shielded Mine VFD Inverter and Feeder Cable

Chinese MT-system mine cables for converter and feeder duty: MVFP shielded inverter cable at 0.38/0.66, 0.66/1.14 and 1.9/3.3 kV for fixed connections between mine frequency converters and motors, with a symmetrical 3+3 earth layout, and MYPTJ-JS 3.6/6 to 8.7/10 kV metallic-screened, monitored rubber feeder cable for underground pumps and equipment. Tinned Class 5 copper and EPR insulation.

Product information
SKU
MVFP-MYPTJ-JS
Brand
TEBAOFLEX
Product overview

Underground coal mines now drive belt conveyors, hoists, winches, fans and main pumps through frequency converters, and the cable between converter and motor sees steep voltage fronts, common-mode currents and electromagnetic interference that ordinary mining power cable is not designed to handle. Chinese MT-system mines specify this link as MVFP, a shielded mine inverter cable, while medium-voltage pump and equipment feeds can be specified as MYPTJ-JS, an enterprise variant of the monitored MYPTJ family. This page covers both designations from 0.38/0.66 kV to 8.7/10 kV.

MVFP is built for fixed connection of mine frequency converter installations at 0.38/0.66 kV, 0.66/1.14 kV and 1.9/3.3 kV. Three tinned Class 5 copper power cores with EPR insulation are laid up with three symmetrical earth cores, for example 3×16+3×4 mm2, so the earth return is balanced, and a metallic screen under a chloroprene-type sheath contains interference. It is not intended for reeling or continuous trailing; mobile 2000 V VFD duty belongs to a different construction. MYPTJ-JS covers 3.6/6, 6/10 and 8.7/10 kV with metallic phase screens, split earth cores, an additional core and a chloroprene-type sheath, in layouts such as 3×16+3×16/3+1×10 mm2, for underground dewatering pumps and equipment feeds.

The JS suffix is an enterprise designation; TEBAOFLEX confirms its construction, the function of the additional core and any immersion conditions on the factory drawing, and no water-depth rating is claimed here. The China MA safety-mark certificates listed for standard MYPTJ on our MYPTJ page do not extend to MYPTJ-JS or MVFP.

Explore the mining and tunneling cable range for related configurations.

Construction

MVFP and MYPTJ-JS Shielded Mine VFD & Feeder Cable Construction

The representative horizontal sample shows an MVFP 0.66/1.14 kV 3x50+3x10 mm2 mine inverter cable: three tinned Class 5 copper power cores with EPR insulation, three symmetrical earth cores in the interstices, a tinned copper wire metallic screen over the core assembly and a flame-retardant chloroprene-type outer sheath; the exact screen arrangement is fixed on the order drawing.

Flat 2D cross-section diagram of MVFP mine inverter cable showing three EPR-insulated power cores, three symmetrical earth cores, overall metallic screen and outer sheath
MVFP cross-section: three EPR-insulated power cores, three symmetrical earth cores, overall metallic screen and flame-retardant chloroprene-type outer sheath.
MVFP and MYPTJ-JS Metallic-Shielded Mine VFD Inverter and Feeder Cable construction
ComponentMaterial and construction
Tinned Class 5 Copper ConductorsTinned annealed copper Class 5 conductors to GB/T 3956 / IEC 60228; MVFP 16 mm2 to 95 mm2 and MYPTJ-JS 16 mm2 to 70 mm2 power cores in the standard layouts shown.
EPR InsulationEthylene propylene rubber insulation rated 90 C continuous; semi-conductive conductor and insulation screens on MYPTJ-JS medium-voltage cores.
Symmetrical or Split Earth CoresMVFP: three symmetrical earth cores in the interstices for a balanced earth return; MYPTJ-JS: three split earth cores, for example 3x16/3 mm2.
Metallic ScreensMVFP: tinned copper wire metallic screen over the core assembly; MYPTJ-JS: tinned copper wire and fibre composite metallic screen on each power core.
Additional Core (MYPTJ-JS)One additional core, for example 1x10 mm2, whose monitoring or earth-check function is fixed on the factory drawing.
Flame-Retardant Chloroprene-Type SheathOil- and abrasion-resistant chloroprene-type rubber sheath designed to the MT/T 386 flame test.

MVFP and MYPTJ-JS Type Designation Breakdown

  • M: coal-mine cable series referencing the MT 818 / KA 818 framework
  • VF (in MVFP): variable-frequency converter (变频) output to motor fixed-installation feeder duty (0.38/0.66 to 1.9/3.3 kV)
  • P (in MVFP): tinned copper wire metallic screen over the laid-up 3+3 core assembly
  • 3+3 earth layout (MVFP): three EPR-insulated power cores laid up with three symmetrical earth cores in the interstices
  • MYPTJ: coal-mine medium-voltage cable with metallic phase screens, split earth cores and monitoring core (MT/T 818.6 family)
  • -JS (in MYPTJ-JS): enterprise-standard 3.6/6 to 8.7/10 kV feeder variant for underground dewatering pumps and equipment feeds
Applications

MVFP and MYPTJ-JS Mine Inverter & Monitored Feeder Applications

Use MVFP for fixed converter-to-motor links and MYPTJ-JS for medium-voltage pump and equipment feeders.

MVFP shielded inverter cables connecting a mine frequency converter cabinet to a belt conveyor drive motor in an underground coal mine
MVFP shielded inverter cables connecting an underground mine frequency converter cabinet to a belt-conveyor drive motor.
  • Fixed connections between mine frequency converters and motors on belt conveyors, hoists, winches and main fans at 0.38/0.66 kV to 1.9/3.3 kV (MVFP).
  • Converter-fed underground pump stations and auxiliary drives where a symmetrical 3+3 earth layout and metallic screen limit interference with mine monitoring systems (MVFP).
  • Underground dewatering pumps and medium-voltage equipment feeds at 3.6/6 kV to 8.7/10 kV (MYPTJ-JS), with any immersion conditions confirmed on the drawing.
  • Chinese coal machinery packages exported to overseas coal mines that call for MVFP or MYPTJ-JS by designation.

MVFP and MYPTJ-JS vs MYPTJ, 2000 V Mining VFD and 3GSEGCH Selection Boundary

MVFP and MYPTJ-JS compared with related mine VFD and monitored MV feeder cables
ModelRated VoltageCore & Screen ArchitectureBest Fit
MVFP (this page)0.38/0.66, 0.66/1.14 & 1.9/3.3 kV3 power + 3 symmetrical earth + tinned Cu wire screenFixed converter-to-motor VFD links on conveyors, hoists, fans and pumps
MYPTJ-JS (this page)3.6/6, 6/10 & 8.7/10 kV3 metallic-screened power + 3 split earths + 1x10 mm² coreUnderground dewatering pumps and MV equipment feeds (-JS specification)
Standard MYPTJ (MT/T 818.6)3.6/6, 6/10 & 8.7/10 kV3 metallic-screened power + earth + ground-checkStandard MT/T 818.6 mobile medium-voltage mining feeders
2000 V Mining VFD / 3GSEGCH2 kV (ICEA) / 6–10 kV (VDE)Symmetrical grounds + overall copper shieldMobile 2000 V trailing VFD duty or German VDE MV VFD motor feeds

MVFP is engineered for fixed converter-to-motor installations (not reeling or trailing); MYPTJ-JS serves 3.6/6 to 8.7/10 kV pump and equipment feeders where the -JS enterprise designation is specified.

Related selection resources

MVFP and MYPTJ-JS Frequently Asked Questions

Why does MVFP use a 3+3 symmetrical earth layout and metallic screen?

Mine frequency converters generate steep dv/dt voltage fronts and common-mode currents. Laying three symmetrical earth cores in the interstices between the three EPR-insulated power cores balances the earth return, while the tinned copper wire metallic screen contains electromagnetic interference so nearby mine monitoring and communication circuits are not disturbed.

Can MVFP be used on mobile reeling drums or continuous trailing chains?

No. MVFP (0.38/0.66, 0.66/1.14 and 1.9/3.3 kV) is designed for fixed installation between frequency converter cabinets and motors on conveyors, hoists, winches, fans and pump stations, with a minimum bending radius of 8 x D. For mobile trailing or reeling VFD duty, select our 2000 V Mining VFD Cable or 3GSEGCH / 3GSEGCY medium-voltage VFD motor cable.

What is MYPTJ-JS and how is it used?

MYPTJ-JS is an enterprise-standard 3.6/6 kV, 6/10 kV and 8.7/10 kV rubber feeder cable based on the MT/T 818.6 MYPTJ family, combining three metallic-screened EPR power cores, three split earth cores (such as 3x16/3 to 3x35/3 mm²) and one 1x10 mm² additional core for underground dewatering pumps and medium-voltage equipment feeds.

What are the minimum order quantity and manufacturing lead time?

The minimum order quantity (MOQ) is 50 m and the manufacturing lead time is 7 to 45 working days, with screen arrangement, additional-core function and any immersion conditions confirmed on the factory drawing.

Specifications

MVFP and MYPTJ-JS Dimensions, Current Rating & Technical Specifications

MVFP and MYPTJ-JS Key Specifications

  • Models covered: MVFP (0.38/0.66, 0.66/1.14 & 1.9/3.3 kV VFD cable) and MYPTJ-JS (3.6/6, 6/10 & 8.7/10 kV feeder)
  • Conductor & insulation: Tinned Class 5 flexible copper (MVFP 16–95 mm²; MYPTJ-JS 16–70 mm²) with 90 °C EPR insulation
  • Earth & screen layout: MVFP: 3+3 symmetrical earth cores + overall tinned Cu wire screen; MYPTJ-JS: metallic phase screens + 3 split earths + 1x10 mm² core
  • Outer sheath: Oil- and abrasion-resistant flame-retardant chloroprene-type rubber sheath tested to MT/T 386-2011
  • Design references: Enterprise specs referencing MT/T 818.6-2009 (KA/T 818.6-2009), MT 818.1-2009, MT/T 386-2011, GB/T 3956
MVFP and MYPTJ-JS Metallic-Shielded Mine VFD Inverter and Feeder Cable technical data
ParameterValue
Design standard referenceEnterprise standards applying the MT 818-2009 flame clauses; MYPTJ-JS follows the MYPTJ construction family of MT/T 818.6-2009 (now KA/T 818.6-2009)
Rated voltagesMVFP 0.38/0.66, 0.66/1.14 and 1.9/3.3 kV; MYPTJ-JS 3.6/6, 6/10 and 8.7/10 kV
Installation boundaryMVFP for fixed installation between converter and motor; not for reeling, festoon or continuous trailing service
Conductor temperature90 C continuous; 250 C short-circuit for max 5 s
Minimum bending radiusAt least 8 x overall diameter for fixed MVFP runs and for MYPTJ-JS
Commercial supply termsMinimum order quantity 50 m; manufacturing lead time 7 to 45 working days; screen arrangement and additional-core function confirmed on the order drawing
Selection boundary vs MYPTJ and 2000 V Mining VFD CableChoose MYPTJ for standard MT/T 818.6 monitored trailing cable and 2000 V Mining VFD Cable for mobile 2000 V VFD duty; choose MVFP or MYPTJ-JS only where these designations are specified.

MVFP 0.38/0.66 kV to 1.9/3.3 kV Symmetrical-Earth Mine VFD Cable Schedule

MVFP 0.38/0.66 kV to 1.9/3.3 kV Shielded Mine Inverter Cable (Fixed Installation, 3+3 Symmetrical Earth) — Nominal Dimensions and Current Rating
Model & Core Layout (mm²)Rated VoltagePower Cores (mm²)Symmetrical Earth Cores (mm²)Nom. EPR Insulation Wall (mm)Nom. Overall O.D. (mm)Approx. Mass (kg/km)Current Rating at 25 °C (A)Next step
MVFP 3x16+3x40.38/0.66 kV3x163x41.231.01650100Request this size
MVFP 3x25+3x60.38/0.66 kV3x253x61.435.22250130Request this size
MVFP 3x35+3x60.38/0.66 kV3x353x61.438.42800150Request this size
MVFP 3x50+3x100.38/0.66 kV3x503x101.643.03700185Request this size
MVFP 3x70+3x160.38/0.66 kV3x703x161.648.24950230Request this size
MVFP 3x95+3x160.38/0.66 kV3x953x161.853.06250280Request this size
MVFP 3x50+3x100.66/1.14 kV3x503x101.845.43950185Request this size
MVFP 3x95+3x160.66/1.14 kV3x953x162.055.66550280Request this size
MVFP 3x50+3x101.9/3.3 kV3x503x103.052.05050185Request this size
MVFP 3x95+3x161.9/3.3 kV3x953x163.061.87900280Request this size

MYPTJ-JS 3.6/6 kV to 8.7/10 kV Metallic-Screened Monitored Feeder Cable Schedule

MYPTJ-JS 3.6/6 kV to 8.7/10 kV Metallic-Screened Monitored Feeder Cable — Nominal Dimensions and Current Rating
Model & Core Layout (mm²)Rated VoltagePower Cores (mm²)Split Earth Cores (mm²)Additional Core (mm²)Nom. Overall O.D. (mm)Approx. Mass (kg/km)Current Rating at 25 °C (A)Next step
MYPTJ-JS 3x16+3x16/3+1x103.6/6 kV3x163x16/31x1050.54100100Request this size
MYPTJ-JS 3x25+3x16/3+1x103.6/6 kV3x253x16/31x1053.04750130Request this size
MYPTJ-JS 3x35+3x16/3+1x103.6/6 kV3x353x16/31x1055.65400150Request this size
MYPTJ-JS 3x50+3x25/3+1x103.6/6 kV3x503x25/31x1059.46500185Request this size
MYPTJ-JS 3x25+3x16/3+1x106/10 kV3x253x16/31x1059.85650130Request this size
MYPTJ-JS 3x50+3x25/3+1x106/10 kV3x503x25/31x1065.07350185Request this size
MYPTJ-JS 3x70+3x35/3+1x106/10 kV3x703x35/31x1069.28800230Request this size
MYPTJ-JS 3x35+3x16/3+1x108.7/10 kV3x353x16/31x1065.66750150Request this size
MYPTJ-JS 3x70+3x35/3+1x108.7/10 kV3x703x35/31x1072.49450230Request this size

Current ratings are nominal values for a single cable in air at 25 C and 90 C conductor temperature; for converter output circuits, also check cable length against the converter dv/dt limits and motor insulation class.

No China MA safety-mark coverage is claimed for MVFP or MYPTJ-JS on this page; the MA certificates for standard MYPTJ apply only to the models and sizes printed on those certificates.

ASCII part references for BOM and ERP entry: MVFP 3x16+3x4, MVFP 3x25+3x6, MVFP 3x35+3x6, MVFP 3x50+3x10, MVFP 3x70+3x16, MVFP 3x95+3x16, MYPTJ-JS 3x16+3x16/3+1x10, MYPTJ-JS 3x25+3x16/3+1x10, MYPTJ-JS 3x35+3x16/3+1x10, MYPTJ-JS 3x50+3x25/3+1x10, MYPTJ-JS 3x70+3x35/3+1x10.

Standards

MVFP and MYPTJ-JS Standards & Test References (MT/T 818.6-2009, MT/T 386-2011)

MVFP and MYPTJ-JS Metallic-Shielded Mine VFD Inverter and Feeder Cable standards and test references
Standard or specificationApplication
MT/T 818.6-2009 (KA/T 818.6-2009)Cables for coal mines, Part 6: metallic-screened monitored mobile flexible cables rated up to 8.7/10 kV (MYPTJ family on which MYPTJ-JS is based).
MT 818.1-2009 (KA 818.1-2009)Cables for coal mines, Part 1: general requirements for mobile flexible cables.
MT/T 386-2011 (KA/T 386-2011)Flame-retardant performance test methods and assessment rules for coal mine cables.
GB/T 3956 / IEC 60228Conductors of insulated cables: Class 5 flexible copper conductor construction and maximum DC resistance.

Certifications and document support

TEBAOFLEX company certificates and quality system documentation

National Public Service Platform for Standards Information (SAMR, China) — GB/T and coal-industry standard records

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    * Required fields. Please include the key cable or application details for review.