TF-WCRW Unipolar Water-Cooled Resistance Welding & Robotic Jumper Cable — DIN EN ISO 8205-2 (120–630 mm² & 350–1,000 MCM)
TF-WCRW (TF-WCRW-ISO8205) is a unipolar single-conductor water-cooled secondary resistance-welding and robotic jumper cable spanning 120 mm² to 630 mm² (DIN EN ISO 8205-2 Types B, C & D) and North American 350 MCM to 1,000 MCM. Constructed with Ø 0.15–0.20 mm tinned or bare Cu-ETP copper ropes, solderless cold-swaged copper palms and PWIS-free 6 bar EPDM or PUR coolant hoses.
TF-WCRW unipolar water-cooled secondary resistance-welding cables carry 4,000 A to 28,000 A single-polarity welding current on robotic servo C-guns and X-guns, stationary pedestal spot/projection welders, seam-welding wheels and manual welding clamps where duty cycles exceed the thermal dissipation limit of air-cooled jumpers, spanning metric 120–630 mm² and North American 350–1,000 MCM.
On modern 1,000 Hz MFDC trans-gun welding robots and multi-gun weld fixtures, compact secondary space often prohibits bulky dual-polarity kickless heads, yet high weld-nugget rates overheat dry air-cooled copper ropes within minutes. TF-WCRW routes 4–6 L/min of cooling water directly around an ultra-flexible Ø 0.15–0.20 mm tinned Cu-ETP rope cold-swaged without solder into forged Cu-HCP rectangular contact palms (DIN EN ISO 8205-2 Design 1, Design 2 and Design 3).
Specify Type C (both ends ISO 8205-2 Design 2) or Type D (ISO Design 2 to Design 3) for standardized European welding guns and platens; specify Type B or TF-WCRW-MCM (350–1,000 MCM with W-series flat/angled lugs) for North American robotic trans-gun jumpers and seam welders; for dry maintenance-free short C-gun shunts at moderate duty cycles, compare TF-ACC air-cooled jumper cable, or for long twin-pole transformer-to-gun runs, switch to TF-KICKLESS bipolar cable. MOQ 5 pcs per specification, 7 to 45 working days.
Explore the welding cable range for related configurations.
TF-WCRW ISO 8205-2 Unipolar Water-Cooled Construction
Manufactured to DIN EN ISO 8205-2 dimensional and hydraulic criteria using solderless circumferential swaging and PWIS-free 5 kV insulating hoses.

| Component | Material and construction |
|---|---|
| 1. Extra-Flexible Tinned or Bare Cu-ETP Rope (Ø 0.15–0.20 mm) | Multi-rope concentric lay of Ø 0.15 mm or Ø 0.20 mm tin-plated electrolytic copper wires resisting aqueous corrosion and repetitive robotic flex fatigue. |
| 2. Optional Perforated Inner Protective Liner (-FC) | Perforated polymer inner sleeve separating copper strands from the outer hose wall while allowing unrestricted 360-degree water circulation. |
| 3. Solderless Cold-Swaged Cu-HCP Contact Palms (ISO 8205-2) | High-pressure hex/circumferential cold-crimped copper heads (optional silver-plated contact faces) with precision G 1/4" or 1/4" NPT water ports and stainless hose rings. |
| 4. Non-Conductive 4.5 mm Wall PWIS-Free Rubber or PUR Coolant Hose | Electrically insulating (5 kV withstand) EPDM/CR rubber hose (standard 4.5 mm wall, or reduced-wall extra-flex) or weld-spatter-resistant polyurethane (PUR) outer hose. |
TF-WCRW Type B, Type C & Type D Code Breakdown
- TF-WCRW-<mm²>B: Unipolar water-cooled welding cable with symmetric compact Design 1 pressed copper palms on both ends
- TF-WCRW-<mm²>C: Both ends fitted with standardized DIN EN ISO 8205-2 Design 2 contact palms and G 1/4" water ports
- TF-WCRW-<mm²>D: Asymmetric combination: one end ISO 8205-2 Design 2 palm and opposite end ISO Design 3 palm
- TF-WCRW-<mm²>R / -MCM: Articulated welding-robot jumper build (160–630 mm² or 350–1,000 MCM) in rubber or PUR outer hose
- -FC Suffix: Internal perforated anti-wear sleeve trapping fatigued copper wires before gun cooling passages
TF-WCRW Robotic Servo Guns, Projection & Seam Welders
Designed for high-duty-cycle single-pole secondary connections on robotic welding guns, pedestal projection welders, seam welders and flash-butt welders.

- Articulated 6-axis robot MFDC servo spot-welding guns (integrated transformer output pad to moving electrode arm).
- Stationary pedestal projection welders, nut/stud welders, fuel-tank / radiator roller seam-welding heads and wire-mesh cross-wire welders.
- Manual water-cooled spot-welding pincers, portable C-clamps, brazing tongs and heavy copper ground-return water-cooled jumpers.
- High-current single-pole water-cooled links in electroplating rectifiers, battery formation racks and resistance-heating fixtures.
TF-WCRW Unipolar vs Air-Cooled Jumper vs Kickless vs H01N2
| Secondary Cable Family | Cooling & Structure | Current Density & Size | Primary Welding Application |
|---|---|---|---|
| TF-WCRW Unipolar (this page) | 4–6 L/min water; 1-pole tinned Cu | 8–12 A/mm² continuous (compact OD) | High-cycle servo C/X-guns, projection & roller seam welders |
| TF-ACC Air-Cooled Jumper | Ambient air; 1-pole bare/wrapped Cu | 2–3.5 A/mm² continuous (larger MCM) | Short trans-gun robot jumpers eliminating water hose plumbing |
| TF-KICKLESS Bipolar (ISO 8205-1) | 7 L/min water; 6-rope 2-pole star core | Go + return in one low-reactance hose | 1.5–4.5 m runs from external transformer to manual/robot gun |
| H01N2-D / H01N2-E & WCT | Ambient air; 100 V dry rubber reel cable | 16–185 mm² bulk reel lead | MMA / MIG / TIG arc-welder electrode & earth return leads |
Upgrading a high-speed robotic gun from air-cooled jumper to TF-WCRW unipolar water-cooled cable cuts required copper cross-section by ~50 % (for example 200 mm² water-cooled replaces 500–630 mm² air-cooled), reducing gun-arm inertia.
TF-WCRW ISO 8205-2 Welding Cable Drawing & RFQ Checklist
- Cross-section (120–630 mm² or 350–1,000 MCM) and exact hole-center to hole-center assembly length (mm or inches).
- Terminal type on End 1 and End 2 (ISO 8205-2 Type B, Type C, Type D, or custom angled/offset lug drawing + rotational orientation).
- Conductor finish (tin-plated Ø 0.20 mm standard vs bare copper) and outer hose (PWIS-free EPDM rubber vs spatter-proof PUR).
- Coolant port thread (G 1/4", G 3/8" or 1/4" NPT) and whether pre-bent hose geometry or double stainless banding (-DB) is required.
- Order quantity per part number (MOQ 5 pcs per specification, 7 to 45 working days).
Related selection resources
- Browse all Water-Cooled, Air-Cooled, Robotic & Arc Welding Cables
- Compare TF-KICKLESS 6-Rope Bipolar Water-Cooled Spot-Welding Cable
- Compare 600 V DC Class M Dry Robotic Trans-Gun Primary Cable
- Compare H01N2-D / H01N2-E 100 V European Arc-Welding Reel Cable
- Engineering guide: Welding cable sizing, duty cycle & voltage drop
- Custom resistance-welding & OEM cable assembly solutions
TF-WCRW Unipolar Water-Cooled Resistance Welding FAQ
What is the difference between Type B, Type C and Type D in DIN EN ISO 8205-2 water-cooled welding cables?
The letter code defines the contact-palm combination on the two ends: Type B uses symmetric compact manufacturer-standard Design 1 palms on both ends; Type C uses DIN EN ISO 8205-2 standardized Design 2 palms on both ends; and Type D pairs an ISO Design 2 palm on one end with a longer/slotted ISO Design 3 palm on the opposite end.
Why does TF-WCRW use tin-plated Ø 0.20 mm copper strands inside a water-cooled hose?
0.20 mm tin-plated copper prevents aqueous corrosion: warm oxygenated cooling water rapidly forms black/green copper-oxide scale on bare fine strands, raising contact resistance and flaking debris into gun cooling passages.
When should I choose a TF-WCRW unipolar water-cooled jumper over a TF-ACC air-cooled jumper on a welding robot?
Choose TF-WCRW when high spot rates (> 30–40 welds/min), projection/seam welding duty cycles, or tight C-gun weight limits require cutting copper mass in half via active 4 L/min water cooling; choose air-cooled TF-ACC when plant policy prohibits water joints over weld tooling.
What working and test water pressures apply to TF-WCRW cooling hoses?
Every TF-WCRW assembly uses a 4.5 mm wall electrically non-conductive hose (5 kV withstand) rated for 6 bar maximum continuous operating pressure, 18 bar burst pressure, and 100 % factory testing at 10 bar before shipment.
What is the minimum order quantity and delivery lead time for TF-WCRW assemblies?
5 pcs per specification (cross-section, center-to-center length and terminal type), custom-swaged, hydro-tested and shipped in 7 to 45 working days.
TF-WCRW (120–630 mm² ISO 8205-2 & 350–1,000 MCM) Schedule
TF-WCRW Pressure, Terminal Types, PWIS-Free Hose & 5-Pc MOQ
- DIN EN ISO 8205-2 Types B, C & D: Standardized contact-palm widths, bolt drillings and G 1/4" coolant ports fit European and global resistance-welding transformers and servo weld guns directly
- Oxidation-proof tinned 0.20 mm Cu: Electrolytic tinned Ø 0.15–0.20 mm copper wire ropes prevent green copper-oxide scale buildup in recirculating plant cooling water
- Perforated strand-trap inner liner: Optional perforated inner sleeve (-FC) boosts flex life on articulated welding robots while trapping broken wire strands before gun water channels
- 6 bar / 18 bar burst 5 kV hose: 4.5 mm wall non-conductive PWIS-free (silicone-free) EPDM rubber or spatter-proof PUR outer hose, 100 % factory pressure-tested at 10 bar
- 5 pcs per specification MOQ: Manufactured in custom millimeter or inch center-to-center lengths (straight, 45°/90° or pre-bent hoses) from 5 pcs MOQ in 7 to 45 working days
| Parameter | Value |
|---|---|
| Rated voltage | Secondary resistance-welding circuit duty with 5000 V AC dielectric withstand coolant hose |
| Cross-section range | Metric 120, 150, 160, 185, 200, 240, 250, 300, 400, 500 and 630 mm2; North American 350, 400, 500, 600, 750 and 1000 MCM |
| Standard terminal designs | Type B (both ends Design 1), Type C (both ends ISO 8205-2 Design 2), Type D (ISO Design 2 + Design 3) and custom angled/offset gun lugs |
| Coolant pressure and temp | 6 bar (87 PSI) max working pressure, 10 bar factory test, 18 bar burst pressure; coolant temperature up to +70 C at 4 L/min minimum flow |
| Minimum order and lead time | 5 pcs per specification (cross-section, hole-to-hole length and terminal code), delivered in 7 to 45 working days |
| Minimum bend radius | 5x outer hose diameter; pre-bent molded coolant hoses available for tight robotic servo-gun dress envelopes |
| Automotive PWIS compliance | 100% silicone-free (PWIS-free / LABS-frei) EPDM rubber and polyurethane hose compounds safe for BIW paint lines |
TF-WCRW (120–630 mm²) DIN EN ISO 8205-2 Metric Schedule
| Model & Cross-Section | Terminal Standard (B / C / D) | Palm Width B × Thickness S (mm) | Hose Nom. OD (mm) | Permanent Current at 4 L/min (A) | Water Thread | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|
| TF-WCRW-120C (120 mm²) | ISO 8205-2 Type C (or B / D) | 25 × 13 | 31 | 1,450 | G 1/4" | 5 pcs | Request this size |
| TF-WCRW-150C (150 mm²) | ISO 8205-2 Type C (or B / D) | 28 × 15 | 32 | 1,750 | G 1/4" | 5 pcs | Request this size |
| TF-WCRW-160R (160 mm² Robot) | Robotic Pair / Gun Jumper | 28 × 15 | 34 | 1,850 | G 1/4" | 5 pcs | Request this size |
| TF-WCRW-185C (185 mm²) | ISO 8205-2 Type C (or B / D) | 28 × 16 | 35 | 2,050 | G 1/4" | 5 pcs | Request this size |
| TF-WCRW-200R (200 mm² Robot) | Robotic Pair / Gun Jumper | 30 × 16 | 36 | 2,200 | G 1/4" | 5 pcs | Request this size |
| TF-WCRW-240C (240 mm²) | ISO 8205-2 Type C (or B / D) | 32 × 18 | 38 | 2,500 | G 1/4" | 5 pcs | Request this size |
| TF-WCRW-250R (250 mm² Robot) | Robotic Pair / Gun Jumper | 32 × 18 | 39 | 2,600 | G 1/4" | 5 pcs | Request this size |
| TF-WCRW-300C (300 mm²) | ISO 8205-2 Type C (or B / D) | 32 × 18 | 42 | 2,950 | G 1/4" | 5 pcs | Request this size |
| TF-WCRW-315R (315 mm² Robot) | Robotic Pair / Gun Jumper | 35 × 19 | 43 | 3,050 | G 1/4" | 5 pcs | Request this size |
| TF-WCRW-400C (400 mm²) | ISO 8205-2 Type C (or B) | 38 × 21 | 46 | 3,550 | G 1/4" | 5 pcs | Request this size |
| TF-WCRW-500C (500 mm²) | ISO 8205-2 Type C (or B) | 42 × 24 | 51 | 4,100 | G 1/4" or 3/8" | 5 pcs | Request this size |
| TF-WCRW-630R (630 mm² Robot) | Heavy Robotic / Seam Welder | 48 × 26 | 56 | 4,700 | G 3/8" | 5 pcs | Request this size |
TF-WCRW-MCM (350–1,000 MCM) North American Unipolar Schedule
| Model & MCM Size | Metric Equiv. (mm²) | Internal Construction | Outer Hose Options | Ref. Weld Current at 20% Duty (kA) | Water Port | Assembly MOQ | Next step |
|---|---|---|---|---|---|---|---|
| TF-WCRW-350M (350 MCM) | 177 mm² | Standard or Perforated Liner (-FC) | PWIS-Free Rubber or PUR | 9–13 kA | 1/4" NPT | 5 pcs | Request this size |
| TF-WCRW-400M (400 MCM) | 203 mm² | Standard or Perforated Liner (-FC) | PWIS-Free Rubber or PUR | 11–15 kA | 1/4" NPT | 5 pcs | Request this size |
| TF-WCRW-500M (500 MCM) | 253 mm² | Standard or Perforated Liner (-FC) | PWIS-Free Rubber or PUR | 14–18 kA | 1/4" NPT | 5 pcs | Request this size |
| TF-WCRW-600M (600 MCM) | 304 mm² | Standard or Perforated Liner (-FC) | PWIS-Free Rubber or PUR | 16–21 kA | 1/4" or 3/8" NPT | 5 pcs | Request this size |
| TF-WCRW-750M (750 MCM) | 380 mm² | Standard or Perforated Liner (-FC) | PWIS-Free Rubber or PUR | 20–25 kA | 3/8" NPT | 5 pcs | Request this size |
| TF-WCRW-1000M (1,000 MCM) | 507 mm² | Heavy Multi-Rope (-FC) | PWIS-Free Rubber or PUR | 25–32 kA | 3/8" or 1/2" NPT | 5 pcs | Request this size |
Permanent thermal current figures reflect 100 % continuous load at 4 L/min water flow and 40 °C water temperature rise on a 1.0–1.5 m jumper; short-pulse resistance spot-welding currents scale 4× to 6× higher per ISO 8205-2 duty-cycle curves. Final palm thickness, offset bend and hole centers follow the approved quotation drawing.
Replacement non-conductive 4.5 mm wall EPDM coolant hoses (inner Ø 25, 28, 32, 35, 38 and 42 mm) and stainless clamping bands can also be supplied alongside complete cable assemblies.
ASCII part references for BOM and ERP entry: TF-WCRW-150C, TF-WCRW-185C, TF-WCRW-240C, TF-WCRW-300C, TF-WCRW-400C, TF-WCRW-500C, TF-WCRW-315R, TF-WCRW-350M, TF-WCRW-500M, TF-WCRW-750M, TF-WCRW-1000M.
TF-WCRW Reference Standards (DIN EN ISO 8205-2 & EN 13602)
| Standard or specification | Application |
|---|---|
| DIN EN ISO 8205-2 Single-Conductor Water-Cooled Welding Cable Standard | Contact-end geometry (Design 2 & Design 3), conductor cross-sections, 6 bar operating / 10 bar test hydraulic pressure and 5 kV hose insulation. |
| DIN EN 13602 & Automotive PWIS-Free / LABS-frei Compliance | Electrolytic Cu-ETP fine wire drawing/tinning and 100 % silicone-free rubber/polyurethane hose compounds. |
Certifications and document support
TEBAOFLEX ISO 9001 quality management and 10 bar hydro-test / micro-ohm inspection
Related cable options
Compare these cable options by service combination, movement, load, voltage and transmission requirement.
TF-KICKLESS Water-Cooled Kickless Welding Cable — 6-Rope Alternate-Polarity Spot-Welding Leads (300–800 MCM & 2×150–2×450 mm²)
A related cable option for a different application or duty profile.
View productRobotic Welding Cable 600 V DC for Articulated Transgun Dress Packs (Class M 34 AWG, 4–4/0 AWG)
A related cable option for a different application or duty profile.
View productH01N2-D & H01N2-E (NSLFFÖU) 100/100 V Rubber Arc Welding Cable (EN 50525-2-81, 10–240 mm²)
A related cable option for a different application or duty profile.
View productRequest a cable recommendation and quotation
Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.
- Include the product name or SKU plus the required cable length and quantity.
- Attach a specification, drawing or data sheet when available.