Welding Cables TEBAOFLEX

TF-WCRW Unipolar Water-Cooled Resistance Welding & Robotic Jumper Cable — DIN EN ISO 8205-2 (120–630 mm² & 350–1,000 MCM)

TF-WCRW (TF-WCRW-ISO8205) is a unipolar single-conductor water-cooled secondary resistance-welding and robotic jumper cable spanning 120 mm² to 630 mm² (DIN EN ISO 8205-2 Types B, C & D) and North American 350 MCM to 1,000 MCM. Constructed with Ø 0.15–0.20 mm tinned or bare Cu-ETP copper ropes, solderless cold-swaged copper palms and PWIS-free 6 bar EPDM or PUR coolant hoses.

Product information
SKU
TF-WCRW-ISO8205
Brand
TEBAOFLEX
Product overview

TF-WCRW unipolar water-cooled secondary resistance-welding cables carry 4,000 A to 28,000 A single-polarity welding current on robotic servo C-guns and X-guns, stationary pedestal spot/projection welders, seam-welding wheels and manual welding clamps where duty cycles exceed the thermal dissipation limit of air-cooled jumpers, spanning metric 120–630 mm² and North American 350–1,000 MCM.

On modern 1,000 Hz MFDC trans-gun welding robots and multi-gun weld fixtures, compact secondary space often prohibits bulky dual-polarity kickless heads, yet high weld-nugget rates overheat dry air-cooled copper ropes within minutes. TF-WCRW routes 4–6 L/min of cooling water directly around an ultra-flexible Ø 0.15–0.20 mm tinned Cu-ETP rope cold-swaged without solder into forged Cu-HCP rectangular contact palms (DIN EN ISO 8205-2 Design 1, Design 2 and Design 3).

Specify Type C (both ends ISO 8205-2 Design 2) or Type D (ISO Design 2 to Design 3) for standardized European welding guns and platens; specify Type B or TF-WCRW-MCM (350–1,000 MCM with W-series flat/angled lugs) for North American robotic trans-gun jumpers and seam welders; for dry maintenance-free short C-gun shunts at moderate duty cycles, compare TF-ACC air-cooled jumper cable, or for long twin-pole transformer-to-gun runs, switch to TF-KICKLESS bipolar cable. MOQ 5 pcs per specification, 7 to 45 working days.

Explore the welding cable range for related configurations.

Construction

TF-WCRW ISO 8205-2 Unipolar Water-Cooled Construction

Manufactured to DIN EN ISO 8205-2 dimensional and hydraulic criteria using solderless circumferential swaging and PWIS-free 5 kV insulating hoses.

Clean 2D circular engineering cross-section of TF-WCRW ISO 8205-2 single-conductor water-cooled welding cable showing black rubber coolant hose, annular water passage, perforated inner liner and 7-rope tinned copper bundle
Unipolar water-cooled cross-section: concentric annular coolant channel around a 1+6 rope-lay tinned copper core inside a 6 bar / 18 bar burst hose.
TF-WCRW Unipolar Water-Cooled Resistance Welding & Robotic Jumper Cable — DIN EN ISO 8205-2 (120–630 mm² & 350–1,000 MCM) construction
ComponentMaterial and construction
1. Extra-Flexible Tinned or Bare Cu-ETP Rope (Ø 0.15–0.20 mm)Multi-rope concentric lay of Ø 0.15 mm or Ø 0.20 mm tin-plated electrolytic copper wires resisting aqueous corrosion and repetitive robotic flex fatigue.
2. Optional Perforated Inner Protective Liner (-FC)Perforated polymer inner sleeve separating copper strands from the outer hose wall while allowing unrestricted 360-degree water circulation.
3. Solderless Cold-Swaged Cu-HCP Contact Palms (ISO 8205-2)High-pressure hex/circumferential cold-crimped copper heads (optional silver-plated contact faces) with precision G 1/4" or 1/4" NPT water ports and stainless hose rings.
4. Non-Conductive 4.5 mm Wall PWIS-Free Rubber or PUR Coolant HoseElectrically insulating (5 kV withstand) EPDM/CR rubber hose (standard 4.5 mm wall, or reduced-wall extra-flex) or weld-spatter-resistant polyurethane (PUR) outer hose.

TF-WCRW Type B, Type C & Type D Code Breakdown

  • TF-WCRW-<mm²>B: Unipolar water-cooled welding cable with symmetric compact Design 1 pressed copper palms on both ends
  • TF-WCRW-<mm²>C: Both ends fitted with standardized DIN EN ISO 8205-2 Design 2 contact palms and G 1/4" water ports
  • TF-WCRW-<mm²>D: Asymmetric combination: one end ISO 8205-2 Design 2 palm and opposite end ISO Design 3 palm
  • TF-WCRW-<mm²>R / -MCM: Articulated welding-robot jumper build (160–630 mm² or 350–1,000 MCM) in rubber or PUR outer hose
  • -FC Suffix: Internal perforated anti-wear sleeve trapping fatigued copper wires before gun cooling passages
Applications

TF-WCRW Robotic Servo Guns, Projection & Seam Welders

Designed for high-duty-cycle single-pole secondary connections on robotic welding guns, pedestal projection welders, seam welders and flash-butt welders.

Unipolar black TF-WCRW water-cooled secondary welding jumper cables with cold-swaged silver-plated flat copper contact palms, stainless clamp rings and brass coolant fittings bolted to a resistance projection welder platen
High-duty-cycle resistance welding platen and robotic servo-gun secondary circuit connected via TF-WCRW ISO 8205-2 water-cooled jumpers.
  • Articulated 6-axis robot MFDC servo spot-welding guns (integrated transformer output pad to moving electrode arm).
  • Stationary pedestal projection welders, nut/stud welders, fuel-tank / radiator roller seam-welding heads and wire-mesh cross-wire welders.
  • Manual water-cooled spot-welding pincers, portable C-clamps, brazing tongs and heavy copper ground-return water-cooled jumpers.
  • High-current single-pole water-cooled links in electroplating rectifiers, battery formation racks and resistance-heating fixtures.

TF-WCRW Unipolar vs Air-Cooled Jumper vs Kickless vs H01N2

TF-WCRW (Unipolar Water-Cooled ISO 8205-2) vs TF-ACC (Air-Cooled Jumper) vs TF-KICKLESS (Bipolar) vs H01N2-D/E
Secondary Cable FamilyCooling & StructureCurrent Density & SizePrimary Welding Application
TF-WCRW Unipolar (this page)4–6 L/min water; 1-pole tinned Cu8–12 A/mm² continuous (compact OD)High-cycle servo C/X-guns, projection & roller seam welders
TF-ACC Air-Cooled JumperAmbient air; 1-pole bare/wrapped Cu2–3.5 A/mm² continuous (larger MCM)Short trans-gun robot jumpers eliminating water hose plumbing
TF-KICKLESS Bipolar (ISO 8205-1)7 L/min water; 6-rope 2-pole star coreGo + return in one low-reactance hose1.5–4.5 m runs from external transformer to manual/robot gun
H01N2-D / H01N2-E & WCTAmbient air; 100 V dry rubber reel cable16–185 mm² bulk reel leadMMA / MIG / TIG arc-welder electrode & earth return leads

Upgrading a high-speed robotic gun from air-cooled jumper to TF-WCRW unipolar water-cooled cable cuts required copper cross-section by ~50 % (for example 200 mm² water-cooled replaces 500–630 mm² air-cooled), reducing gun-arm inertia.

TF-WCRW ISO 8205-2 Welding Cable Drawing & RFQ Checklist

  • Cross-section (120–630 mm² or 350–1,000 MCM) and exact hole-center to hole-center assembly length (mm or inches).
  • Terminal type on End 1 and End 2 (ISO 8205-2 Type B, Type C, Type D, or custom angled/offset lug drawing + rotational orientation).
  • Conductor finish (tin-plated Ø 0.20 mm standard vs bare copper) and outer hose (PWIS-free EPDM rubber vs spatter-proof PUR).
  • Coolant port thread (G 1/4", G 3/8" or 1/4" NPT) and whether pre-bent hose geometry or double stainless banding (-DB) is required.
  • Order quantity per part number (MOQ 5 pcs per specification, 7 to 45 working days).

Related selection resources

TF-WCRW Unipolar Water-Cooled Resistance Welding FAQ

What is the difference between Type B, Type C and Type D in DIN EN ISO 8205-2 water-cooled welding cables?

The letter code defines the contact-palm combination on the two ends: Type B uses symmetric compact manufacturer-standard Design 1 palms on both ends; Type C uses DIN EN ISO 8205-2 standardized Design 2 palms on both ends; and Type D pairs an ISO Design 2 palm on one end with a longer/slotted ISO Design 3 palm on the opposite end.

Why does TF-WCRW use tin-plated Ø 0.20 mm copper strands inside a water-cooled hose?

0.20 mm tin-plated copper prevents aqueous corrosion: warm oxygenated cooling water rapidly forms black/green copper-oxide scale on bare fine strands, raising contact resistance and flaking debris into gun cooling passages.

When should I choose a TF-WCRW unipolar water-cooled jumper over a TF-ACC air-cooled jumper on a welding robot?

Choose TF-WCRW when high spot rates (> 30–40 welds/min), projection/seam welding duty cycles, or tight C-gun weight limits require cutting copper mass in half via active 4 L/min water cooling; choose air-cooled TF-ACC when plant policy prohibits water joints over weld tooling.

What working and test water pressures apply to TF-WCRW cooling hoses?

Every TF-WCRW assembly uses a 4.5 mm wall electrically non-conductive hose (5 kV withstand) rated for 6 bar maximum continuous operating pressure, 18 bar burst pressure, and 100 % factory testing at 10 bar before shipment.

What is the minimum order quantity and delivery lead time for TF-WCRW assemblies?

5 pcs per specification (cross-section, center-to-center length and terminal type), custom-swaged, hydro-tested and shipped in 7 to 45 working days.

Specifications

TF-WCRW (120–630 mm² ISO 8205-2 & 350–1,000 MCM) Schedule

TF-WCRW Pressure, Terminal Types, PWIS-Free Hose & 5-Pc MOQ

  • DIN EN ISO 8205-2 Types B, C & D: Standardized contact-palm widths, bolt drillings and G 1/4" coolant ports fit European and global resistance-welding transformers and servo weld guns directly
  • Oxidation-proof tinned 0.20 mm Cu: Electrolytic tinned Ø 0.15–0.20 mm copper wire ropes prevent green copper-oxide scale buildup in recirculating plant cooling water
  • Perforated strand-trap inner liner: Optional perforated inner sleeve (-FC) boosts flex life on articulated welding robots while trapping broken wire strands before gun water channels
  • 6 bar / 18 bar burst 5 kV hose: 4.5 mm wall non-conductive PWIS-free (silicone-free) EPDM rubber or spatter-proof PUR outer hose, 100 % factory pressure-tested at 10 bar
  • 5 pcs per specification MOQ: Manufactured in custom millimeter or inch center-to-center lengths (straight, 45°/90° or pre-bent hoses) from 5 pcs MOQ in 7 to 45 working days
TF-WCRW Unipolar Water-Cooled Resistance Welding & Robotic Jumper Cable — DIN EN ISO 8205-2 (120–630 mm² & 350–1,000 MCM) technical data
ParameterValue
Rated voltageSecondary resistance-welding circuit duty with 5000 V AC dielectric withstand coolant hose
Cross-section rangeMetric 120, 150, 160, 185, 200, 240, 250, 300, 400, 500 and 630 mm2; North American 350, 400, 500, 600, 750 and 1000 MCM
Standard terminal designsType B (both ends Design 1), Type C (both ends ISO 8205-2 Design 2), Type D (ISO Design 2 + Design 3) and custom angled/offset gun lugs
Coolant pressure and temp6 bar (87 PSI) max working pressure, 10 bar factory test, 18 bar burst pressure; coolant temperature up to +70 C at 4 L/min minimum flow
Minimum order and lead time5 pcs per specification (cross-section, hole-to-hole length and terminal code), delivered in 7 to 45 working days
Minimum bend radius5x outer hose diameter; pre-bent molded coolant hoses available for tight robotic servo-gun dress envelopes
Automotive PWIS compliance100% silicone-free (PWIS-free / LABS-frei) EPDM rubber and polyurethane hose compounds safe for BIW paint lines

TF-WCRW (120–630 mm²) DIN EN ISO 8205-2 Metric Schedule

TF-WCRW Metric Unipolar Water-Cooled Resistance Welding Cable (120–630 mm²) — DIN EN ISO 8205-2 Types B, C & D Schedule
Model & Cross-SectionTerminal Standard (B / C / D)Palm Width B × Thickness S (mm)Hose Nom. OD (mm)Permanent Current at 4 L/min (A)Water ThreadAssembly MOQNext step
TF-WCRW-120C (120 mm²)ISO 8205-2 Type C (or B / D)25 × 13311,450G 1/4"5 pcsRequest this size
TF-WCRW-150C (150 mm²)ISO 8205-2 Type C (or B / D)28 × 15321,750G 1/4"5 pcsRequest this size
TF-WCRW-160R (160 mm² Robot)Robotic Pair / Gun Jumper28 × 15341,850G 1/4"5 pcsRequest this size
TF-WCRW-185C (185 mm²)ISO 8205-2 Type C (or B / D)28 × 16352,050G 1/4"5 pcsRequest this size
TF-WCRW-200R (200 mm² Robot)Robotic Pair / Gun Jumper30 × 16362,200G 1/4"5 pcsRequest this size
TF-WCRW-240C (240 mm²)ISO 8205-2 Type C (or B / D)32 × 18382,500G 1/4"5 pcsRequest this size
TF-WCRW-250R (250 mm² Robot)Robotic Pair / Gun Jumper32 × 18392,600G 1/4"5 pcsRequest this size
TF-WCRW-300C (300 mm²)ISO 8205-2 Type C (or B / D)32 × 18422,950G 1/4"5 pcsRequest this size
TF-WCRW-315R (315 mm² Robot)Robotic Pair / Gun Jumper35 × 19433,050G 1/4"5 pcsRequest this size
TF-WCRW-400C (400 mm²)ISO 8205-2 Type C (or B)38 × 21463,550G 1/4"5 pcsRequest this size
TF-WCRW-500C (500 mm²)ISO 8205-2 Type C (or B)42 × 24514,100G 1/4" or 3/8"5 pcsRequest this size
TF-WCRW-630R (630 mm² Robot)Heavy Robotic / Seam Welder48 × 26564,700G 3/8"5 pcsRequest this size

TF-WCRW-MCM (350–1,000 MCM) North American Unipolar Schedule

TF-WCRW-MCM North American Single-Conductor Water-Cooled Welding & Robotic Jumper Leads (350–1,000 MCM)
Model & MCM SizeMetric Equiv. (mm²)Internal ConstructionOuter Hose OptionsRef. Weld Current at 20% Duty (kA)Water PortAssembly MOQNext step
TF-WCRW-350M (350 MCM)177 mm²Standard or Perforated Liner (-FC)PWIS-Free Rubber or PUR9–13 kA1/4" NPT5 pcsRequest this size
TF-WCRW-400M (400 MCM)203 mm²Standard or Perforated Liner (-FC)PWIS-Free Rubber or PUR11–15 kA1/4" NPT5 pcsRequest this size
TF-WCRW-500M (500 MCM)253 mm²Standard or Perforated Liner (-FC)PWIS-Free Rubber or PUR14–18 kA1/4" NPT5 pcsRequest this size
TF-WCRW-600M (600 MCM)304 mm²Standard or Perforated Liner (-FC)PWIS-Free Rubber or PUR16–21 kA1/4" or 3/8" NPT5 pcsRequest this size
TF-WCRW-750M (750 MCM)380 mm²Standard or Perforated Liner (-FC)PWIS-Free Rubber or PUR20–25 kA3/8" NPT5 pcsRequest this size
TF-WCRW-1000M (1,000 MCM)507 mm²Heavy Multi-Rope (-FC)PWIS-Free Rubber or PUR25–32 kA3/8" or 1/2" NPT5 pcsRequest this size

Permanent thermal current figures reflect 100 % continuous load at 4 L/min water flow and 40 °C water temperature rise on a 1.0–1.5 m jumper; short-pulse resistance spot-welding currents scale 4× to 6× higher per ISO 8205-2 duty-cycle curves. Final palm thickness, offset bend and hole centers follow the approved quotation drawing.

Replacement non-conductive 4.5 mm wall EPDM coolant hoses (inner Ø 25, 28, 32, 35, 38 and 42 mm) and stainless clamping bands can also be supplied alongside complete cable assemblies.

ASCII part references for BOM and ERP entry: TF-WCRW-150C, TF-WCRW-185C, TF-WCRW-240C, TF-WCRW-300C, TF-WCRW-400C, TF-WCRW-500C, TF-WCRW-315R, TF-WCRW-350M, TF-WCRW-500M, TF-WCRW-750M, TF-WCRW-1000M.

Standards

TF-WCRW Reference Standards (DIN EN ISO 8205-2 & EN 13602)

TF-WCRW Unipolar Water-Cooled Resistance Welding & Robotic Jumper Cable — DIN EN ISO 8205-2 (120–630 mm² & 350–1,000 MCM) standards and test references
Standard or specificationApplication
DIN EN ISO 8205-2 Single-Conductor Water-Cooled Welding Cable StandardContact-end geometry (Design 2 & Design 3), conductor cross-sections, 6 bar operating / 10 bar test hydraulic pressure and 5 kV hose insulation.
DIN EN 13602 & Automotive PWIS-Free / LABS-frei ComplianceElectrolytic Cu-ETP fine wire drawing/tinning and 100 % silicone-free rubber/polyurethane hose compounds.

Certifications and document support

TEBAOFLEX ISO 9001 quality management and 10 bar hydro-test / micro-ohm inspection

ISO 8205-2 — Water-cooled secondary connection cables for resistance welding (Part 2: Single-conductor cables)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.

    Email or WhatsApp is enough. Please include the key cable or application details for review.