Marine & Offshore Cables TEBAOFLEX

MVCECH 3.6/6 kV to 12/20 kV Medium-Voltage Halogen-Free Marine Power Cable (IEC 60092-354)

MVCECH is a 3.6/6 (7.2) kV, 6/10 (12) kV, 8.7/15 (17.5) kV and 12/20 (24) kV medium-voltage halogen-free shipboard power cable engineered to IEC 60092-354. Built with single-core or three-core compacted Class 2/5 stranded copper, triple-extruded semiconductive screens over 90 °C XLPE/EPR insulation, individual copper wire/tape metallic screens, optional overall copper braid and a red SHF1 halogen-free outer sheath rated -40 °C to +90 °C.

Product information
SKU
TF-MVCECH-20KV
Brand
TEBAOFLEX
Product overview

MVCECH is a medium-voltage halogen-free shipboard power cable family covering 3.6/6 (7.2) kV, 6/10 (12) kV, 8.7/15 (17.5) kV and 12/20 (24) kV AC per IEC 60092-354 and IEC 60092-350/360. High-tonnage cruise liners, LNG/LPG carriers, container vessels with cold-ironing shore-power systems, cable-laying ships and electric-propulsion icebreakers rely on medium-voltage distribution to move megawatt-scale power without unmanageable low-voltage copper cross-sections.

Every MVCECH core is triple-extruded in a single pass—bonding an inner extruded semiconductive conductor screen, high-purity 90 °C XLPE (or HEPR) insulation and a clean-stripping outer semiconductive layer for void-free electric-field grading and straightforward MV termination preparation. Each screened core carries an individual copper wire/tape earth-fault screen; three-core constructions add halogen-free fillers, an inner covering, a heavy bare copper wire braid (or galvanized steel braid on request) and a red SHF1 flame-retardant, low-smoke, zero-halogen outer jacket rated from -40 °C to +90 °C with a tight 9 × D minimum fixed bending radius.

Specify MVCECH for fixed shipboard 6.6 kV, 11 kV, 15 kV and 20 kV switchboard feeders, main generators, propulsion transformers and shore-connection bus ducts; choose IEC 62613 AMP shore-to-ship reeling cables for dynamic dockside reels, or NEK 606 RFOU MV where offshore mud-resistant SHF2 jackets are required. Minimum order 50 m; lead time 7 to 45 working days.

Explore the marine, offshore and shipboard cable range for related configurations.

Construction

MVCECH Triple-Extruded Medium-Voltage Shipboard Construction

Triple-extruded medium-voltage shipboard insulation core with individual metallic earth-fault screens, halogen-free bedding, overall copper braid and red SHF1 jacket.

Clean 2D technical cross-section of 3-core MVCECH 6/10–12/20 kV medium-voltage shipboard cable showing red SHF1 sheath, copper braid screen, black filler bedding and three triple-extruded XLPE cores with inner and outer black semiconductive layers
3-core MVCECH cross-section showing void-free triple-extruded conductor screen, XLPE dielectric, outer semicon layer and metallic earth-fault screens.
MVCECH 3.6/6 kV to 12/20 kV Medium-Voltage Halogen-Free Marine Power Cable (IEC 60092-354) construction
ComponentMaterial and construction
1. Compacted Class 2 or Flexible Class 5 Copper ConductorAnnealed plain or tinned stranded electrolytic copper per IEC 60228 from 16 mm² to 300 mm² (1-core and 3-core configurations).
2. Triple-Extruded Semiconductive Screens + 90 °C XLPE / EPR InsulationBonded inner conductor screen, void-free cross-linked insulation sized for 3.6/6 kV through 12/20 kV, and easily strippable outer semiconductive layer.
3. Individual Copper Wire / Copper Tape Phase ScreenConcentric copper wires with counter-helix copper tape binder (or copper tape screen) providing symmetrical fault-current return around every phase.
4. Halogen-Free Inner Bedding & Overall Copper Braid (MVCECH)Non-hygroscopic halogen-free bedding under an overall copper wire braid (or optional galvanized steel wire braid for mechanical armouring).
5. Red SHF1 Halogen-Free Flame-Retardant Outer SheathHigh-visibility red (or black) SHF1 low-smoke zero-halogen jacket meeting IEC 60332-3-22 Cat. A, IEC 60754 and IEC 61034 from -40 °C to +90 °C.

MVCECH Medium-Voltage Marine Designation Breakdown

  • MV: Medium-voltage shipboard power cable family designed to IEC 60092-354 (6 kV to 24 kV Um)
  • CE: Triple-extruded semiconductive-screened XLPE / EPR dielectric with individual copper phase screens
  • C: Overall bare copper wire braid screen / fault-current metallic covering
  • H: Halogen-free, low-smoke, flame-retardant SHF1 thermoplastic outer sheath (red standard)
  • 3.6/6 – 12/20 kV: Rated phase-to-earth / phase-to-phase AC voltage class across 1-core and 3-core layouts
Applications

MVCECH Shipboard HV Switchboard, Propulsion & Cold-Ironing Applications

Designed for fixed medium-voltage generation, main switchboard interconnection and electric-propulsion distribution aboard ocean-going vessels.

Modern LNG carrier medium-voltage propulsion switchboard corridor with heavy red MVCECH marine cables sweeping cleanly on curved stainless steel ladder trays
Shipboard medium-voltage main propulsion switchboard distribution corridor fitted with red SHF1 halogen-free MVCECH feeders.
  • 6.6 kV and 11 kV main diesel-generator and gas-turbine feeders connecting engine rooms to HV main switchboards.
  • Medium-voltage electric propulsion transformers, podded/azimuth thruster converters and shaft-generator tie feeders.
  • Fixed onboard shore-to-ship (AMP / cold-ironing) 6.6 kV and 11 kV distribution runs from the shore connection box to the main bus.
  • High-capacity cargo pumps, reefer distribution transformers and offshore support vessel MV ring mains.

MVCECH vs Offshore RFOU MV vs IEC 62613 Shore Reeling

MVCECH (IEC 60092-354) vs Offshore NEK 606 RFOU MV vs Shore-to-Ship IEC 62613 Reeling Cable
Cable SeriesVoltage SpanOuter Jacket & FlexPrimary Marine Deployment
MVCECH (this page)3.6/6 to 12/20 kVRed SHF1 LSZH (fixed 9 × D)Fixed onboard HV switchboards, generators & propulsion trays
NEK 606 RFOU / BS 6883 MVA3.6/6 to 12/20 kVSHF2 Mud-Resistant LSZHOffshore platforms, FPSO decks & drilling-mud zones
IEC 62613 AMP Reeling6/10 to 6.6/11 kVHeavy PCP / PUR dynamic reelingMotorized dockside shore-power reels & dynamic shore cords
M2XCH-VFD 1.8/3 kV0.6/1 & 1.8/3 kVBlack SHF1 LSZH (3+3 EMC)Low-voltage 690 V thruster & winch VFD motor feeders

Always confirm single-core vs three-core fault-current screen cross-section and non-magnetic cleat spacing before finalizing MV marine switchboard layouts.

MVCECH 6/10–12/20 kV Medium-Voltage Marine RFQ Checklist

  • Nominal system voltage (3.6/6 kV, 6/10 kV, 8.7/15 kV or 12/20 kV) and 1-core vs 3-core configuration.
  • Conductor cross-section (16–300 mm²), stranding class (Class 2 compacted or Class 5 flexible) and required metallic screen fault rating.
  • Insulation preference (XLPE standard or HEPR on request) and overall metallic layer (copper wire braid standard or galvanized steel braid).
  • Required length per size (MOQ 50 m), cut-length drum plan and any third-party witnessed HV/PD inspection (lead time 7 to 45 working days).

Related selection resources

MVCECH Medium-Voltage Marine Power Cable FAQ

What voltage ratings are available in the MVCECH medium-voltage marine power cable series?

MVCECH covers all four mainstream shipboard medium-voltage classes per IEC 60092-354: 3.6/6 (7.2) kV, 6/10 (12) kV, 8.7/15 (17.5) kV and 12/20 (24) kV AC, in both single-core and three-core constructions.

Why does MVCECH require triple-extruded semiconductive screens over the XLPE insulation?

At 6 kV to 20 kV, microscopic air gaps between stranded copper wires and solid insulation create concentrated electric stress that triggers partial discharge and rapid treeing failure. Co-extruding inner and outer semiconductive layers with the XLPE dielectric creates smooth equipotential boundaries.

What is the minimum bending radius of MVCECH medium-voltage marine cables?

MVCECH is designed for a compact 9 × D minimum fixed bending radius across 3.6/6 kV through 12/20 kV—tighter than land-based armoured utility cables so installers can navigate shipboard switchboard rooms and bulkhead penetrations cleanly.

Why is MVCECH supplied with a red outer sheath?

Red SHF1 sheathing follows established marine electrical safety practice to visually warn shipboard personnel that a cable tray carries medium voltage (6 kV to 20 kV) rather than standard 0.6/1 kV black power feeders.

What is the MOQ and lead time for custom MVCECH marine cables?

50 m minimum order per size, custom-manufactured and routine HV/partial-discharge tested in 7 to 45 working days.

Specifications

MVCECH 3.6/6 kV to 12/20 kV Dimension & Test Schedule

MVCECH Electrical, Partial-Discharge & Thermal Ratings

  • Four MV marine voltage classes: 3.6/6 (7.2) kV, 6/10 (12) kV, 8.7/15 (17.5) kV and 12/20 (24) kV AC engineered to IEC 60092-354
  • Triple-extruded partial-discharge control: Dry-cured inner conductor screen, 90 °C XLPE/EPR dielectric and strippable outer semiconductive layer eliminate air voids
  • Individual copper metallic screens + overall braid: Individual copper wire/tape phase screens safely carry earth-fault currents beneath halogen-free bedding and optional overall braid
  • Compact 9 × D fixed bending radius: Class 2 or flexible Class 5 copper (16 mm² to 300 mm²) simplifies routing through congested cruise, LNG and OSV switchboard decks
  • 50 m MOQ with routine HV & PD testing: Red (or black) SHF1 zero-halogen sheath (IEC 60332-3-22 Cat. A), custom-manufactured in 7 to 45 working days
MVCECH 3.6/6 kV to 12/20 kV Medium-Voltage Halogen-Free Marine Power Cable (IEC 60092-354) technical data
ParameterValue
Rated voltage3.6/6 (7.2) kV, 6/10 (12) kV, 8.7/15 (17.5) kV and 12/20 (24) kV AC per IEC 60092-354
Routine AC test voltage12.5 kV (3.6/6 kV), 21 kV (6/10 kV), 30.5 kV (8.7/15 kV) and 42 kV (12/20 kV) AC
Operating temperature range-40 °C to +90 °C fixed service (-15 °C minimum installation; 250 °C short-circuit)
Minimum bending radius9 × D fixed installation (single-core and three-core compacted IEC 60092-354 build)
Conductor and sheath16 mm² to 300 mm² (1C or 3C) Class 2/5 copper with triple-extruded XLPE/EPR and red SHF1 halogen-free jacket
Minimum order and lead time50 m minimum order quantity per size; custom manufacturing lead time 7 to 45 working days

MVCECH 3.6/6 kV to 12/20 kV Medium-Voltage Marine Schedule

MVCECH 3.6/6 kV to 12/20 kV Medium-Voltage Halogen-Free Marine Power Cable Representative Schedule
Model & Size (mm²)Rated VoltageAC Test VoltageNominal OD (mm)Approx. Weight (kg/km)Min. Bend RadiusOrder MOQNext step
MVCECH 3×25 (3.6/6 kV)3.6/6 (7.2) kV12.5 kV39.52,4809 × D50 mRequest this size
MVCECH 3×50 (3.6/6 kV)3.6/6 (7.2) kV12.5 kV44.83,5409 × D50 mRequest this size
MVCECH 3×95 (3.6/6 kV)3.6/6 (7.2) kV12.5 kV53.25,4209 × D50 mRequest this size
MVCECH 1×150 (6/10 kV)6/10 (12) kV21.0 kV32.42,1809 × D50 mRequest this size
MVCECH 3×35 (6/10 kV)6/10 (12) kV21.0 kV47.23,3609 × D50 mRequest this size
MVCECH 3×70 (6/10 kV)6/10 (12) kV21.0 kV54.54,8909 × D50 mRequest this size
MVCECH 3×120 (6/10 kV)6/10 (12) kV21.0 kV62.86,9809 × D50 mRequest this size
MVCECH 3×185 (6/10 kV)6/10 (12) kV21.0 kV71.49,5209 × D50 mRequest this size
MVCECH 3×50 (8.7/15 kV)8.7/15 (17.5) kV30.5 kV57.84,6409 × D50 mRequest this size
MVCECH 3×95 (8.7/15 kV)8.7/15 (17.5) kV30.5 kV66.26,7909 × D50 mRequest this size
MVCECH 1×240 (12/20 kV)12/20 (24) kV42.0 kV44.63,4509 × D50 mRequest this size
MVCECH 3×70 (12/20 kV)12/20 (24) kV42.0 kV67.86,4809 × D50 mRequest this size

Routine high-voltage withstand and partial-discharge verification is performed on every manufactured length prior to dispatch. Both 1-core (for high-amp single-phase bus runs in non-magnetic trefoil cleats) and 3-core configurations are supplied up to 300 mm².

ASCII part references for BOM and ERP entry: MVCECH-6KV-3x25, MVCECH-6KV-3x50, MVCECH-6KV-3x95, MVCECH-10KV-1x150, MVCECH-10KV-3x35, MVCECH-10KV-3x70, MVCECH-10KV-3x120, MVCECH-10KV-3x185, MVCECH-15KV-3x50, MVCECH-15KV-3x95, MVCECH-20KV-1x240, MVCECH-20KV-3x70.

Standards

MVCECH IEC 60092-354 Medium-Voltage Marine Standards

MVCECH 3.6/6 kV to 12/20 kV Medium-Voltage Halogen-Free Marine Power Cable (IEC 60092-354) standards and test references
Standard or specificationApplication
IEC 60092-354Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (Um = 7.2 kV) up to 30 kV (Um = 36 kV).
IEC 60092-350 & IEC 60092-360General construction, test methods and SHF1 halogen-free sheathing requirements for shipboard cables.
IEC 60332-3-22 Cat. A, IEC 60754-1/-2 & IEC 61034-1/-2Bunched vertical flame spread, zero-halogen corrosivity and low-smoke density safety reference.

Certifications and document support

TEBAOFLEX ISO 9001:2015 production QA and routine HV/PD test records

IEC 60092-354 — Electrical Installations in Ships: Single- and Three-Core MV Power Cables 6 kV to 30 kV

IEC 60332-3-22 — Bunched Cable Vertical Flame Spread Test (Category A)

Compare by duty

Related cable options

Compare these cable options by service combination, movement, load, voltage and transmission requirement.

Engineering-led quotation

Request a cable recommendation and quotation

Send the required services, cable length, mechanical duty, environment, termination and quantity. Our team will review the application before quoting.

  • Include the product name or SKU plus the required cable length and quantity.
  • Attach a specification, drawing or data sheet when available.

    MOQ 50 m · Engineering reply within 24 hours

    By submitting this form, you agree that TEBAOFLEX may use the contact information and files provided to review and respond to your enquiry. Files are used for quotation and engineering communication related to your request. See our Privacy Policy for current data handling and retention information.